• 제목/요약/키워드: Stirring Rate

검색결과 190건 처리시간 0.027초

지속성 제제의 개발에 관한 연구 (I) 아스코르빈산 나트륨의 CAP 마이크로캅셀의 제조 및 평가 (Studies on the Development of Sustained Release Preparation (I) Preparation and Evaluation of CAP Microcapsules of Sodium Ascorbate)

  • 신상철;고익배
    • Journal of Pharmaceutical Investigation
    • /
    • 제21권4호
    • /
    • pp.253-262
    • /
    • 1991
  • Microencapsulation of sodium ascorbate with cellulose acetate phthalate(CAP) by coacervation/ phase separation method were carried out. Various factors affecting microencapsulation, i.e., surfactant concentration. CAP concentration, stirring speed and treatment of spermaceti as a sealing agent were studied. Dissolution rate. particle size distribution, surface feature and stability test were investigated. CAP microcapsules prepared using 0.5% span 80 as a surfactant showed smooth and round surfaces. The release of sodium ascorbate was retarded by microencapsulation with CAP and by sealant treatment with spermaceti. When triturated with sodium bicarbonate, CAP microcapsules were more stable than unencapsulated sodium ascorbate under various RH conditions at $37^{\circ}C$.

  • PDF

Plating of Permalloy Using Flow Cell

  • Jeon, S.H.;Ahn, J.H.;Kang, T.
    • 한국표면공학회지
    • /
    • 제32권3호
    • /
    • pp.423-427
    • /
    • 1999
  • Electroplating of 80%Ni permalloy thin plate for magnetic core materials. was studied The convected flow of electrolyte was used for stirring methode. The current density could be increased up to 250mA/$\textrm{cm}^2$ by flow cell. The composition of electroplated layer with vespect to current density and flow rate was investigated and experimental equation to predict the composition was made. How cell yielded more uniform thickness distribution than paddle cell did. The composition distribution was also studied. The thickness was the most important factor to the permeability. The permeability of 5$\mu\textrm{m}$plated permalloy was over 2000 at 1 MHz.

  • PDF

고정화 효소전극을 이용한 포도당분석 (Glucose Analysis Using Free and Immobilized Glucose Oxidase Electrode)

  • 장호남;주대권;김영성
    • 대한의용생체공학회:의공학회지
    • /
    • 제3권2호
    • /
    • pp.95-100
    • /
    • 1982
  • Glucose oxidase from A. niger was entrapped in polyacrylamide gel which was used in the enzyme electrode for glucose analysis. The electrode was assembled by placing the gel between the membranes on the surface of a Clark type electrode. In order to make it possible to analyze the experimental results later, the stagnation flow was adopted wheree the governing fluid mechanics were well known. The current increased with the increase concentration in the bulk below a certain level of glucose concentration beyond which no more current increase was observed. This is probably due to the diffusion limitation of oxygen from the bulk solution. Also the current increased witll the enzyme loading in the gel, but the linearity between the current and the glucose concentration was rather limited to a narrow range. Flow rate was found to be very important, which means that film diffusion is very important under the flow rate of 5cm/sec. As a conclusion, enzyme loading, gel layer thickness, stirring speed and bulk concentration of glucose were found to be most improtant parameters in yielding a linar current reponse with respect to the bulk glucose concentration.

  • PDF

Lipase-catalyzed Esterification of (S)-Naproxen Ethyl Ester in Supercritical Carbon Dioxide

  • Kwon, Cheong-Hoon;Lee, Jong-Ho;Kim, Seung-Wook;Kang, Jeong-Won
    • Journal of Microbiology and Biotechnology
    • /
    • 제19권12호
    • /
    • pp.1596-1602
    • /
    • 2009
  • A lipase-catalyzed esterification reaction of (S)-naproxen ethyl ester by CALB (Candida antarctica lipase B) enzyme was performed in supercritical carbon dioxide. Experiments were performed in a high-pressure cell for 10 h at a stirring rate of 150 rpm over a temperature range of 313.15 to 333.15 K and a pressure range of 50 to 175 bar. The productivity of (S)-naproxen ethyl ester was compared with the result in ambient condition. The total reaction time and conversion yields of the catalyzed reaction in supercritical carbon dioxide were compared with those at ambient temperature and pressure. The experimental results show that the conversion and reaction rate were significantly improved at critical condition. The maximum conversion yield was 9.9% (216 h) at ambient condition and 68.9% (3 h) in supercritical state. The effects of varying amounts of enzyme and water were also examined and the optimum condition was found (7 g of enzyme and 2% water content).

액중건조법으로 제조한 Retinol 함유 마이크로캡슐의 방출 거동 (Controlled Release of Retinol Containing Microcapsules Prepared by Solvent Evaporation Method)

  • 김세라;신영재;이천일;표형배;신재섭
    • 접착 및 계면
    • /
    • 제9권2호
    • /
    • pp.1-7
    • /
    • 2008
  • 생분해성이 있는 polycaprolactone을 사용하여 용액 상태에서 건조시키는 방법으로 마이크로 캡슐을 제조하였다. 심물질로는 화장품 분야에서 중요한 성분으로 쓰이는 retinol을 선택하였으며 안정제로는 poly(vinyl alcohol)을 사용하였다. 제조 조건에 따른 마이크로캡슐의 형태 변화와 물성 변화를 scanning electron microscope와 differential scanning calorimeter를 이용하여 측정하였으며 심물질의 방출 속도에 미치는 영향들을 UV를 이용하여 측정하였다. 사용한 벽재 물질 용액의 농도, 교반속도, 안정제의 농도 등을 변화 시켜 가면서 마이크로캡슐을 제조하여 보았으며, 최적 조건에서 지름이 5~6 um인 구형 모양의 균일한 크기를 갖는 마이크로캡슐들이 형성되었음을 확인하였다.

  • PDF

진공상태에서의 전열현상에 대한 실험적 연구 (Experimental Study of Heat Transfer in Vacuum Furnace)

  • 양제복;김원배;동상근
    • 한국연소학회:학술대회논문집
    • /
    • 대한연소학회 2003년도 제27회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.109-113
    • /
    • 2003
  • Low pressure or vacuum carburizing(LPC) has undergone major further developments since 1980 and now it has achieved industrial maturity. The advantage of low pressure vacuum carburizing over gas carburizing is not only the creation of surface entirely free of oxide and environmentally friendly but also a reduction in batch times, lower gas and energy consumption and the prevention of soot. In this study the experiment was carried out to investigate the effects of vacuum atmosphere in the heating furnace. Heat transfer rate and uniformity of temperatures of test samples in the pressure range of a few 0.1torr was examined on a test charge of 100kg. It is found that the fuel saving rate due to decreasing heating time reach to 20% in the vacuum heating mode as compared with atmospheric heating mode. Also the uniformity of temperatures in the samples was improved significantly in the vacuum heating mode. Also the effects of the RC fan for stirring atmosphere inside furnace was examined. Results shows RC fan appears to provide a reasonable tool for improving uniformity of temperature in the atmospheric heating mode.

  • PDF

Flocculation Characteristics of Kaoline Suspensions in Water by Cationic Polyelectrolytes

  • Kam, Sang-Kyu;Kim, Dae-kyoung;Ko, Byung-Churl;Moon, Chang-Seong;Lee, Min-Gyu
    • 한국환경과학회지
    • /
    • 제11권2호
    • /
    • pp.93-102
    • /
    • 2002
  • Using a simple continuous optical technique, coupled with measurements of zeta potential, the flocculation characteristics of kaoline suspensions of different content(15, 35 and 55 NTU) by several cationic polyelectrolytes, has been examined. The optimum mixing is obtained under a constant stirring of 200 rpm, differently from a general flocculation test. The charge density of a polyelectrolyte is important in determining the optimum dosage and in the removal of kaoline particles. The optimum dosage is less for the polyelectrolyte of higher charge density and is the same regardless of kaoline content. At the dosage, the removal of kaoline particles is higher for the polyelectrolyte of higher charge density and zeta potential of kaoline particles reaches to near zero. The rate of adsorption and flocculation rate have been found to be affected by charge density and molecular weight of a polyelelctrolyte and the content of kaoline particles.

Preparation of biodegradable microspheres containing water-soluble drug, $\beta$-lactam$ antibiotic

  • Kim, Jin-Hee;Kwon, Ick-Chan;La, Sung-Bum;Jeong, Seo-Young;Young, Taek-Sohn;Seo, Young-Jeong
    • Archives of Pharmacal Research
    • /
    • 제19권1호
    • /
    • pp.30-35
    • /
    • 1996
  • Poly(l-lactic acid)(PLLA) microspheres loaded with ampicillin sodium (AMP-Na_, .betha.-lactam antibiotic, were prepared by a w/o/w multiple emulsion-solvent evaporation method. The amounts of each component in three phases (inner water phase, organic phase, and outer water phase) wre carefully examined in the preparation of PLLA microspheres. The stirring rate, another preparation parameter, was also investigated for study on the effect of mechanical stress on the drug loading and morphology of PLLA microspheres. Most of the preparation parameters had a great influence on the drug loading, surface morphology and size distribution of PLLA microspheres. PLLA microspheres with 15.89 w/w% drug loading were subjected to the in vitro release experimet. The release of ampicillin sodium was constant at a rate of 1.68 $mug/ml/day$ per 1 mg of microspheres for 18 days initial burst effect.

  • PDF

The Fabrication of Megasonic Agitated Module(MAM) for the Improved Characteristics of Wet Etching

  • Park, Tae-Gyu;Yang, Sang-Sik;Han, Dong-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • 제3권2호
    • /
    • pp.271-275
    • /
    • 2008
  • The MAM(Megasonic Agitated Module) has been fabricated for improving the characteristics of wet etching. The characteristics of the MAM are investigated during the wet etching with and without megasonic agitation in this paper. The adoption of the MAM has improved the characteristics of wet etching, such as the etch rate, etch uniformity, and surface roughness. Especially, the etching uniformity on the entire wafer was less than ${\pm}1%$ in both cases of Si and glass. Generally, the initial root-mean-square roughness($R_{rms}$) of the single crystal silicon was 0.23nm. Roughnesses of 566nm and 66nm have been achieved with magnetic stirring and ultrasonic agitation, respectively, by some researchers. In this paper, the roughness of the etched Si surface is less than 60 nm. Wet etching of silicon with megasonic agitation can maintain nearly the original surface roughness during etching. The results verified that megasonic agitation is an effective way to improve etching characteristics of the etch rate, etch uniformity, and surface roughness and that the developed micromachining system is suitable for the fabrication of devices with complex structures.

미소채널 내 회전교반기와 진동교반기에 의한 혼합향상의 연구 (A Study on Mixing Enhancement by Rotating and Oscillating Stirrers in the Micro Channel)

  • 김용대;맹주성;안상준
    • 대한기계학회논문집B
    • /
    • 제30권5호
    • /
    • pp.430-437
    • /
    • 2006
  • The mixing effect is studied by comparing rotating and oscillating stirrers in the micro channel. The cases of Re=10 to 80 with various stirring speeds are considered to analysis the effect of Re and stirrer speed for the mixing. Under Re=20, the oscillating stirrer represents better mixing rate than the rotating stirrer up to the critical stirrer speed which has a maximum efficiency. Over Re=30, the results of oscillating and rotating stirrer show that the faster the stirrer speed, the higher the mixing effect within the concerned stirrer speed range and the oscillating stirrer keeps the higher mixing rate. It was found that the mixing effect is a function which has an optimum of the Reynolds number and the stirrer speed. The D2Q9 Lattice Boltzmann Method is used due to the merits of calculation for the unsteady flow with moving boundary.