• Title/Summary/Keyword: Stimulus artifact

Search Result 6, Processing Time 0.019 seconds

Evaluation of the Device Failure Using Stimulus Artifact in the Cochlear Implantee (인공와우 이식자에서 자극 잡파를 이용한 고장 평가)

  • Heo, Seung-Deok;Kim, Sang-Ryeol;Ahn, Joong-Ki;Jung, Dong-Keun;Kang, Myung-Koo
    • Speech Sciences
    • /
    • v.14 no.2
    • /
    • pp.35-42
    • /
    • 2007
  • The aim of this study is to analyze the correlation between current intensity and amplitude of stimulus artifact on the cochlear implantee, and to find out basic information to check the device failure. Subjects were a prelingual child and 3 postlingual adults with more than severe hearing losses. The charge-balanced biphasic pulses were presented at stimulus rates of 11 pulses per second, each pulse width of $25{\mu}s$ with monopolar mode(MP1+2). Current intensities were delivered at 27.5, 33.7, 41.3, 50.5, 61.9, $75.8{\mu}A$. Stimulus artifacts were recorded by evoked potential system. This procedure was performed just before the initial stimulation, and then, the amplitude of stimulus artifacts were compared with each current intensity. The amplitude of stimulus artifacts was increased significantly according to the current intensity (p<0.01). The results suggest that the change of the amplitude of stimulus artifact can be used as a good cue to check the device failure in the cochlear implantee.

  • PDF

Stimulus Artifact Suppression on the type of Nerve Stimulator (신경자극기 형태에 따른 자극 Artifact 제거 방법에 대한 연구)

  • 유세근;민병관
    • Journal of Biomedical Engineering Research
    • /
    • v.14 no.3
    • /
    • pp.251-256
    • /
    • 1993
  • The conduction velocity of the nerve is of importance to the diagnosis of various negromuscular disorders. A major technical problem encountered in nerve stimulation technique is the control of stimulus artifact and the convenience of nerve stimulator. The remained artifacts must be removed by processing the contaminated signal. This paper discusses about the artifact cancellation algorithms in constant voltage type nerve stimulator(CVS) and constant current type nerve stimulator(CCS).

  • PDF

The advantage of topographic prominence-adopted filter for the detection of short-latency spikes of retinal ganglion cells

  • Ahn, Jungryul;Choi, Myoung-Hwan;Kim, Kwangsoo;Senok, Solomon S.;Cho, Dong-il Dan;Koo, Kyo-in;Goo, Yongsook
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.21 no.5
    • /
    • pp.555-563
    • /
    • 2017
  • Electrical stimulation through retinal prosthesis elicits both short and long-latency retinal ganglion cell (RGC) spikes. Because the short-latency RGC spike is usually obscured by electrical stimulus artifact, it is very important to isolate spike from stimulus artifact. Previously, we showed that topographic prominence (TP) discriminator based algorithm is valid and useful for artifact subtraction. In this study, we compared the performance of forward backward (FB) filter only vs. TP-adopted FB filter for artifact subtraction. From the extracted retinae of rd1 mice, we recorded RGC spikes with $8{\times}8$ multielectrode array (MEA). The recorded signals were classified into four groups by distances between the stimulation and recording electrodes on MEA (200-400, 400-600, 600-800, $800-1000{\mu}m$). Fifty cathodic phase-$1^{st}$ biphasic current pulses (duration $500{\mu}s$, intensity 5, 10, 20, 30, 40, 50, $60{\mu}A$) were applied at every 1 sec. We compared false positive error and false negative error in FB filter and TP-adopted FB filter. By implementing TP-adopted FB filter, short-latency spike can be detected better regarding sensitivity and specificity for detecting spikes regardless of the strength of stimulus and the distance between stimulus and recording electrodes.

Stimulus artifact suppression on the type of Nerve Stimulator. (신경지극기 형태에 따른 자극 Artifact 제거 방법에 대한 연구)

  • Yoo, S.K.;Min, B.G.;Kim, J.W.;Kim, J.W.;Kim, S.H.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.209-212
    • /
    • 1992
  • A major technical problem in encountered in nerve stimulation technique is the control of stimulus artifact and the convenience of nerve stimulator. The artifacts remained must be removed by processing the contaminated signal. This paper discusses about the artifact cancellation algorithms in constant voltage type nerve stimulator(CVS) and constant current type nerve stimulator(CCS).

  • PDF

Stimulus Artifact Suppression Using the Stimulation Synchronous Adaptive Impulse Correlated Filter for Surface EMG Application

  • Yeom, Ho-Jun;Park, Ho-Dong;Chang, Young-Hui;Park, Young-Chol;Lee, Kyoung-Joung
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.3
    • /
    • pp.451-458
    • /
    • 2012
  • The voluntary EMG (vEMG) signal from electrically stimulated muscle is very useful for feedback control in functional electrical stimulation. However, the recorded EMG signal from surface electrodes has unwanted stimulation artifact and M-wave as well as vEMG. Here, we propose an event-synchronous adaptive digital filter for the suppression of stimulation artifact and M-wave in this application. The proposed method requires a simple experimental setup that does not require extra hardware connections to obtain the reference signals of adaptive digital filter. For evaluating the efficiency of this proposed method, the filter was tested and compared with a least square (LS) algorithm using previously measured data. We conclude that the cancellation of both primary and residual stimulation artifacts is enhanced with an event-synchronous adaptive digital filter and shows promise for clinical application to rehabilitate paretic limbs. Moreover because this algorithm is far simpler than the LS algorithm, it is portable and ready for real-time application.

Physiologic state and behavioral response to sponge bathing in premature infants (스폰지 목욕에 대한 미숙아의 생리적상태 및 행동반응)

  • Lee Hae Kyung;Hong Kyung Ja;Nam Eun Sook;Lee Young Hee;Jung Eun Ja
    • Child Health Nursing Research
    • /
    • v.6 no.1
    • /
    • pp.32-50
    • /
    • 2000
  • A descriptive exploratory design was used in this study to evaluate the effects of sponge bathing on physiological(heart rate, heart period, vagal tone, oxygen saturation, respiration) and behavioral responses in newly born 40 preterm infants from intensive care unit of S University Hospital in Seoul. Data has been collected from October, 1997 to March, 1999. The infants were between 27-33 weeks gestational age at birth, and were free of congenital defects. The subjects entered the protocol when they were medically stable (determined by initiation of feeding and discontinuation of all respiratory support) but still receiving neonatal intensive care. The infants' physiologic parameters were recorded a 10 - minute before, during, and after bathing. Continuous heart rate data were recorded on a notebook computer from the infant's EKG monitor. The data were digitized off-line on software(developed by Lee and Chang in Wavelet program) which detected the peak of the R wave for each heart beat and quantified sequential R-R intervals in msec(i.e. heart periods). Heart period data were edited to remove movement artifact. Heart period data were quantified as : 1) mean heart period; 2) vagal tone. Vagal tone was quantitfied with a noninvasive measure developed by Porges(1985) in Mxedit software. To determine behavioral status, tools were developed by Scafidi et al(1990) were used. Collected data were analyzed with the SPSS program using paried t-test, ANOVA, and Pearson correlation. The result were as follow. 1. The results of the ANOVAs indicated that vagal tone were signifcantly lower during bathing than baseline and post-bathing. There were significant differences in heart period and heart rate levels across the bathing. But the mean oxygen saturations and respirations were no differences. Also, there were no significant differences on behavioral sign, motor activity, behavioral distress, weight changes, morbidity, and hospitalization period. 2. To evaluate the relation between vagal tone and subsequent parameters, the two groups (the high group had 19 subjects and low group had 21subjects) were divided by the mean baseline vagal tone. Vagal tone measured prior to bathing were significantly associated with respiration before bathing, vagal tone during bathing, and the magnitude of change in both vagal tone. But, other subsequent reactivities were no differences in two groups. 3. Correlations were also calculated between vagal tone and the subsequent physiological reactivities from baseline through after- bathing. Correlations were significant between baseline vagal tone and baseline heart rate, between baseline vagal tone and baseline heart period, between baseline vagal tone and oxygen saturation after bathing. In summary, the bathing in this study showed a stressful stimulus on premature infants through there was significance in the physiological parameters. In addition, our study represents the documentation that vagal tone reactivity in response to clearly defined external stimulation provides an index of infant's status.

  • PDF