• 제목/요약/키워드: Step-Deterioration

검색결과 75건 처리시간 0.025초

YBCO/STO/YBCO 다층박막 제작 (Fabrication of YBCO/STO/YBCO Multilayer)

  • 하동한;황태종;임해용;김진철;김동호;박종철;박용기
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 1999년도 High Temperature Superconductivity Vol.IX
    • /
    • pp.34-37
    • /
    • 1999
  • We have fabricated YBCO/STO/YBCO multilayer by the pulsed laser deposition method varing the deposition condition of insulating STO layer. Superconducting properties of both YBCO layers are sensitively affected by the deposition condition of STO layer. We obtained the upper YBCO layer of T$_{c(zero)}\;{\sim}\;$90 K with a good reproducibility, however, T$_{c(zero)}$ of lower YBCO layer was decreased to about 80 K maybe due to the oxygen loss during the deposition of STO layer. Superconducting properties of both YBCO layers at every fabrication step were measured in order to study the reason for the deterioration of superconducting properties.

  • PDF

Pt/Ti 발열체가 내장된 TMA 가스 측정용 ZnO 박막 가스 센서 (ZnO thin film Gas sensors for detection of TMA gas with Pt/Ti thin film heater)

  • 류지열;박성현;최혁환;권태하
    • 전자공학회논문지A
    • /
    • 제33A권6호
    • /
    • pp.127-135
    • /
    • 1996
  • To increase the sensitivity and the selectivity of the sensors to TMA gas, the composition ratio and the growth conditions of the ZnO films are studied. Annealing of the ZnO films in the various time ranges and temperatures in the oxygen is carried out to enhance the stbility of the electrical resistance. Pt/Ti heater deposited on backside of the substrates in used to control the operating temperature of th esensor. The ZnO thin film sensors doped to 4.0 wt% $Al_{2}$O$_{3}$ 1.0wt.% TiO$_{2}$ and 0.2wt.% V$_{2}$O$_{5}$ exhibited a high sensitivity and an excellent selectivity for TMA gas. The sensors made with the thin films annealed at 700$^{\circ}$C for 60 minutes in the oxygen atmosphere had a good stability and linearity. The heater deposited in the ratio of 1 to 1 (Pt:Ti) had a good heating properties. The sensors fabricated using above conditions showed a good response to the actual gases of a mackerel at a step of deterioration after death.

  • PDF

복합재료 교량 시스템의 정적거동 분석 및 파괴모드에 관한 연구 (Study of Failure Mode and Static Behavio of Lightweight FRP Bridge Deck System)

  • 정우영;이형길;안병윤;백상훈
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2006년도 정기 학술대회 논문집
    • /
    • pp.922-927
    • /
    • 2006
  • There is a concern with worldwide deterioration of highway bridges, particularly reinforced concrete. The advantages of fibre reinforced plastic(FRP) composites over conventional materials motivate their use in highway bridges for replacement of structures. Recently, an FRP deck has been installed on a state highway, located in New York State, as an experimental project. In this paper, a systematic approach for analysis of this FRP deck bridge is presented. Multi-step linear numerical analyses have been performed using the finite element method to study the structural behavior and the possible failure mechanism of the FRP deck-superstructure system Deck's self-weight and ply orientations at the interface between steel girders and FRP deck are considered in this study. From this research, the results of the numerical analyses were corroborated with field test results. Analytical results reveal several potential failure mechanism for the FRP deck and truss bridge system The results presented in this study may be used to propose engineering design guideline for new and replacement FRP bridge deck structure.

  • PDF

Evaluating stability of dam foundations by borehole and surface survey using Step Frequency Radar

  • Jha Prakash C.;Balasubramaniam V. R.;Nelliat Sandeep;Sivaram Y. V.;Gupta R. N.
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 한국지구물리탐사학회 2003년도 Proceedings of the international symposium on the fusion technology
    • /
    • pp.328-334
    • /
    • 2003
  • Evaluating stability of dam foundations is one of the prime areas of any rock engineering investigations. Despite best engineering efforts in the design and construction of dam foundations, the foundation regime of a constructed dam suffers deterioration due to continuous erosion from backwater current of dam discharge and dynamic effects of loading and unloading process. Even during construction, development of frequent cracks due to sudden thermal cooling of concrete blocks is not uncommon. This paper presents two case studies from India and Bhutan. In the first case, the back current of water discharge from the Srisailam dam in India had continuously eroded the apron and has eaten into the dam foundation. In the second case with dam construction at Tala Hydroelectric Project in Bhutan, sudden overflow of river during the construction stage of dam had led to development of three major cracks across the dam blocks. This was ascribed to adiabatic cooling effect of concrete blocks overlain by chilled water flow. Non-destructive evaluation of rock mass condition in the defect regime by the borehole GPR survey helped in arriving at the crux so as to formulate appropriate restoration plan.

  • PDF

비정렬 격자계에서 LU Implicit Scheme의 수렴성 및 안정성 해석 : Part I-오일러 방정식 (Convergence and Stability Analysis of LU Scheme on Unstructured Meshes: Part I - Euler Equations)

  • 김주성;권오준
    • 한국항공우주학회지
    • /
    • 제32권9호
    • /
    • pp.1-11
    • /
    • 2004
  • 본 연구에서는 비정렬 격자계에서 가장 많이 쓰이는 근사 해법 중의 하나인 LU 기법의 오일러 방정식에 대한 수렴성 및 안정성에 관한 연구를 수행하였다. 적절한 스칼라 모델 방정식을 사용하여 LU기법이 갖는 고유한 특성에 관해서 해석적으로 논의하였으며, 이를 system of equations 형태인 오일러 방정식으로 확장 해석하였다. 해석 결과 LU 기법의 수렴성 및 안정성은 격자 종횡비와 연관된 특별한 독립변수의 조합으로 표현되며, 이러한 독립 변수의 조합을 사용하여 어떠한 종횡비의 격자에 대해시도 수렴성 및 안정성의 저하 현상이 발생되지 않음을 보였다.

국내 역사계박물관의 소장자료 분류체계와 수장고 분류방안 (Classification System of Collections and Distribution of Storages in Domestic Museum of Historic Relics)

  • 정성욱
    • 한국실내디자인학회논문집
    • /
    • 제15권2호
    • /
    • pp.138-149
    • /
    • 2006
  • A museum's collections is fundamental factors to construct important activity of museum performing a role as cultural facility for learning, education and research. Therefore, conservation of collections through appropriate environments is previously established in step of planing a museum. Hereby, the purpose of this study is to set up the classification of collections and suggest a useful guidance of the storage division in a domestic museum. The results of this study are as follows. First, the main factors of deterioration are temperature and relative humidity in a museum storage, so classification of collections should be set up according to the objective standards of these factors. Second, the classification of collections can be performed as follow: the group for nonorganic materials subdivide metal, chinaware, earthenware, and jade stone, the group for organic materials subdivide leather hair paper fabric, bone horn shell mound and wood herbage and the group for composed materials. Third, for storage division of a domestic museum, basically has to consider that it is reasonable to plan $4{\sim}5$ storages in metal, jade stone, chinaware earthenware, and organic materials of $1{\sim}2$ units in case of a serial of history like archaeological, antique museum. And in case of folk relics of modern and contemporary arts are collected, it is reasonable to plan over 5 storages add composed materials to foregoing classification.

병렬 연결된 리튬이온전지 셀의 비파괴 전기화학적 열화상태 진단 (Degradation diagnosis of parallel-connected lithium-ion battery cells via non-constructive electrochemical approach)

  • 이가람;정지윤;김용태;최진섭
    • 한국표면공학회지
    • /
    • 제55권4호
    • /
    • pp.231-235
    • /
    • 2022
  • As environmental pollution becomes more serious, the demand for electric vehicles (EVs) and lithium-ion batteries for electric vehicles is rapidly increasing worldwide. Accordingly, the amount of waste batteries is also increasing, and a technology for recycling and reusing them is required. In order to reuse a used battery, it is necessary to non-destructively diagnose the deterioration condition of the battery. Therefore, in this study, we investigate the diagnosis of degradation for parallel-connected lithium-ion battery cells through non-constructive electrochemical approach. As the number of parallel-connected cells increased, in addition to linear degradation, abrupt step-like degradation occurred, which is attributed to the predominant degradation of specific cells. In addition, it is confirmed that deteriorated cells among multiple cells can be distinguished through a simple measurement of open circuit voltage (OCV).

Fungal Load of Groundwater Systems in Geographically Segregated Islands: A Step Forward in Fungal Control

  • Joong Hee Cho;Nam Soo Jun;Jong Myong Park;Ki In Bang;Ji Won Hong
    • Mycobiology
    • /
    • 제50권5호
    • /
    • pp.345-356
    • /
    • 2022
  • The fungal distribution, diversity, and load were analyzed in the geographically segregated island groundwater systems in Korea. A total of 79 fungal isolates were secured from seven islands and identified based on the internal transcribed spacer (ITS) sequences. They belonged to three phyla (Ascomycota, Basidiomycota, and Chlorophyta), five classes, sixteen orders, twenty-two families, and thirty-one genera. The dominant phylum was Ascomycota (91.1%), with most fungi belonging to the Cladosporium (21.5%), Aspergillus (15.2%), and Stachybotrys (8.9%) genera. Cladosporium showed higher dominance and diversity, being widely distributed throughout the geographically segregated groundwater systems. Based on the diversity indices, the genera richness (4.821) and diversity (2.550) were the highest in the groundwater system of the largest scale. As turbidity (0.064-0.462) increased, the overall fungal count increased and the residual chlorine (0.089-0.308) had low relevance compared with the total count and fungal diversity. Cladosporium showed normal mycelial growth in de-chlorinated sterilized samples. Overall, if turbidity increases under higher fungal diversity, bio-deterioration in groundwater-supplying facilities and public health problems could be intensified, regardless of chlorine treatment. In addition to fungal indicators and analyzing methods, physical hydrostatic treatment is necessary for monitoring and controlling fungal contamination.

포장두부의 가공공정에서 미생물 분석 및 안전성 평가 (Microbial Analysis and Safety Evaluation in the Process of Packaged Tofus)

  • 왕순남;최성원;허남윤;백무열;이한승;김창남
    • 생명과학회지
    • /
    • 제19권4호
    • /
    • pp.486-491
    • /
    • 2009
  • 본 연구는 생산 후 3일 이내인 시판두부의 가공공장별, 두부유형별 위생실태를 파악하여 두부에 대한 미생물 규격의 설정 가능성을 검토하며, 가공단계별 총생균수와 대장균군을 분석하여 오염 원인을 규명코자 실시되었다. 시판중인 두부의 위생성은 동일유형이더라도 가공공장마다 차이가 있었고 동일공장의 시료 간에도 차이를 보였다. 총생균수가 $1.0{\times}10^6CFU/g$ 이상을 보인 일부 포장두부에서는 관능적 부패 변질 현상이 관찰되었다. 총 148개 두부시료 중 총생균수와 대장균군이 각각 $1.0{\times}10^5CFU/g$ 이하와 음성에 적합한 시료는 단순포장두부가 32.0%와 12.0%, 포장가열두부가 86.9%와 83.7%인 것으로 조사되었다. 이러한 가공공장에 따른 위생성 차이는 가열과 열처리사이의 공정인 응고, 압착, 성형, 1차냉각, 내포장공정에서 2차오염 정도의 차이에서 기인하는 것으로 생각되었다. 포장두부의 가공공정 중 미생물이 증가하여 각별한 관리가 요구되는 공정으로는 원료대두의 세척 침지와 마쇄, 응고 후 압착 성형, 1차냉각공정이었다. 따라서 보다 위생적인 두부를 가공하기 위해서는 이들 가공공정에서 사용되는 각종 설비나 작업도구, 성형포 및 작업자 등에 대한 세척 및 소독 강화가 절실하게 요구되었다.

단순 작업성 심관류 모델에서의 신생돈 심장의 보존 후 백혈구-제거 혈액을 이용한 재관류가 심근 VCAM-1 발현 및 심기능에 미치는 영향 (Effect of reperfusion with leukocyte-depleted blood on the expression of myocardial vascular cell adhesion molecule-1 (VCAM-1) and myocardial function in isolated working heart perfusion model)

  • 이정렬;석철준;서정욱;한재진
    • Journal of Chest Surgery
    • /
    • 제33권3호
    • /
    • pp.213-220
    • /
    • 2000
  • Background: Adhesion of leukocytes to myocardium or vascular endothelium has been known as an importation initial step in the ischemia-reperfusion injury which may affect the cardiac function. Therefore, leukocyte-depleted reperfusion may inhibit ischemia-reperfusion induced functional and ultrastructural deterioration. In this study, we quantified the time-dependent expression of the vascular cell adhesion molecule-1(VCMA-1) on piglet myocardium and demonstrated its relation to functional recovery using isolated piglet heart perfusion model. Material and Method: Neonatal(1 to 3 day old) piglet heart was harvested with 4$^{\circ}C$ University of Wisconsin solution (UWS) and presrved in the same solution for 12 hours. Ex vivo model of an isolated working neonatal piglet heart perfusion consisting of membrane oxygenator and roller-pump was used (Fig. 1). Hearts were grouped into leukocyte-non-depleted (group A, n=8) and leukocyte-depleted group(group B, n=8). In group B, hearts were reperfused with leukocyte-depleted blood using a leukocyte filter (Sepacell R, Asahi Medical, Japan). Segments of right atrium were taken before and after 1, 2, 3, and 4 hours of reperfusion for the evaluation of expression of VCAM-1. The intensity of immunohistochyemical satining of the VCAM-1 on the myocardium were graded semiquantitatively (0 to 4). For the evaluation of myocardial stroke work indices were calculated as well at the same time-points. Result: Mean expressins of VCAM-1 on the myocardium at 0, 1, 2, 3, adn 4 hours of reperfusion were 0.63, 1.44, 1.64, 2.65, and 3.34 in group A, while 0.56, 1.40, 1.50, 1.88 and 2.14 in group B (Fig. 3). Mean stroke work indices at 0.5, 1, 2, 3, and 4 hours after reperfusion were 1.35$\times$104, 1.32$\times$104, 1.14$\times$104, 0.81$\times$104, 0.68$\times$104 erg/gm in group A, while 1.40$\times$104, 1.43$\times$104, 1.43$\times$104, 1.28$\times$104, and 1.12$\times$104 erg/em in group B(Fig. 4). Conclusion : In this study, we demonstrated that leukocyte-depletion attenuated the expression of VCAM-1 during reperfusion and the time-dependent functional deterioration of the myocardium was well correlated with the degree of VCAM-1 expression.

  • PDF