• Title/Summary/Keyword: Step wedges

Search Result 9, Processing Time 0.019 seconds

The Effects of Toe Wedges on the Spatiotemporal Gait Parameters of Adolescents with Spastic Diplegic Cerebral Palsy (발가락 벌림 교정기가 청소년기 경직형 양하지 뇌성마비의 보행에 미치는 영향)

  • Jang, Jung-Jae;Jung, Sun-Hye;Kim, Myung-Jong;Song, Sun-Hae;Lee, Dong-Geon;Lee, Seung-Hoo;Jang, Na-Young;Choi, Ji-Won;Ha, Sun-Young;Ha, Shin-Ho;Hong, Soung-Kyun;Lee, Gyu-Chang
    • PNF and Movement
    • /
    • v.17 no.2
    • /
    • pp.237-243
    • /
    • 2019
  • Purpose: The purpose of the present study was to investigate the effects of toe wedges on the gait ability of adolescents with spastic diplegic cerebral palsy. Methods: Six adolescents with spastic diplegic cerebral palsy participated in this study. During the participants walked with- and without toe wedges, the gait ability was analyzed using the electronic walkway system. Gait parameters, including velocity, cadence, step length, stride length, single support time, and double support time, were collected and analyzed. Results: When the participants walked with toe wedges, there were significant improvements in gait velocity, cadence, and double support time compared to those without toe wedges (p<0.05). However, there were no significant differences in step length, stride length, and single support time. Conclusion: Toe wedges may have a positive effect on the gait ability of adolescents with spastic diplegic cerebral palsy. However, it is necessary to conduct high-quality studies to identify the effects of toe wedges.

EXPERIMENTAL STUDY OF INFLUENCE ON RADIOGRAPHIC DENSITY AND CONTRAST BY THE CHANGE OF KILOVOLTAGE AND EXPOSURE TIME (관전압과 X선노출시간의 변화가 X선사진의 흑화도와 대조도에 미치는 영향에 관한 실험적 연구)

  • Lee Byeong Do;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.20 no.1
    • /
    • pp.113-124
    • /
    • 1990
  • For the study of the influence of kilovoltage and exposure time on radiographic density and contrast, we measured radiographic density of aluminum step wedge which composed of contiguous 8 steps wedges of 2-16㎜ thickness with densitometer. Aluminum step wedge was radiographed on Kodak ultraspeed DF-58 and Ektaspeed EP-21 film with range of 60-90 kVp and 5-60 impulse and subject contrast of aluminum step wedge with constant radiographic density and image contrast percentage without radiographic density was evaluated. Then we evaluated the film quality of teeth and their surrounding structure according to the change of kVp and exposure time by score rating method. The obtained results were as follows: 1. Radiographic density was related to the change of kilovoltage, especially in increased exposure time. 2. With constant radiographic density, subject contrast of thin aluminum step wedges was greater in low kilovolt age than high kilovoltage, but kilovolt age had not great influence on subject contrast of thick aluminum step wedge. On the other hand, radiographic density difference between 2mm and 16mm aluminum step wedge was decreased according to in- creasing kilovoltage. 3. Without constant radiographic density, image contrast percentage was decreased with increasing kilovoltage, but was not related with the change of exposure time. 4. Radiographic contrast of teeth and their surrounding structure which was taken with the range of 60-90 kVp and 6-30 impulse had not great influence on film quality.

  • PDF

X-ray Sensitometry by Bootstrap Method Using New Step Wedge (새로운 step wedge의 Bootstrap법에 의한 X선 sensitometry)

  • Ahn, Bong-Seon;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.14 no.1
    • /
    • pp.45-48
    • /
    • 1991
  • Recently developed new step wedge has a small size as $10{\times}10\;cm^2$. It can use central beam, and is affected little by scattered rays emmitted from the neighboring step wedges. It's characteristics are same as the intensity scale method, and are excellent compared with conventional boot strap methods. Moreover, the method using new step wedge is simple in operation, and the characteristics are excellent. Now, the above method using new step wedge can supercede the distance method.

  • PDF

Water impact of three dimensional wedges using CFD

  • Nair, Vinod V.;Bhattacharyya, S.K.
    • Ocean Systems Engineering
    • /
    • v.8 no.2
    • /
    • pp.223-246
    • /
    • 2018
  • In this paper the results of CFD simulations, that were carried out to study the impact pressures acting on a symmetric wedge during water entry under the influence of gravity, are presented. The simulations were done using a solver implementing finite volume discretization and using the VOF scheme to keep track of the free surface during water entry. The parameters such as pressure on impact, displacement, velocity, acceleration and net hydrodynamic forces, etc., which govern the water entry process are monitored during the initial stage of water entry. In addition, the results of the complete water entry process of wedges covering the initial stage where the impact pressure reaches its maximum as well as the late stage that covers the rebound process of the buoyant wedge are presented. The study was conducted for a few touchdown velocities to understand its influence on the water entry phenomenon. The simulation results are compared with the experimental measurements available in the literature with good accuracy. The various computational parameters (e.g., mesh size, time step, solver, etc.) that are necessary for accurate prediction of impact pressures, as well as the entry-exit trajectory, are discussed.

The determination of reference material for bone density by using bone phantom (골판톰을 이용한 골밀도측정 참조체의 결정)

  • Kim Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.135-139
    • /
    • 2002
  • Purpose: To determine the proper reference step wedge for digital Cu-Equivalent Image analyzing systems for measurement of bone density. Meterials and Methods : Radiograms of lumbar vertebrae phantom (1g/㎠) with 3 test copper step wedges of 0.03, 0.05 and, 0.1 mm thickness unit were taken and analyzed using NIH image software on a Macintosh personal computer. Measured densities of the lumbar areas in the Cu-Equivalent images made by utilizing 3 different copper stepwedges were compared with a known bone density. Results: The values of r2 for all copper equivalent images were over 0.99. The mean Cu-Eq value of lumbar in copper equivalent image made by a 0.1 mm copper stepwedge was 0.22 ± 0.06 mm and converted to hydroxyapatite density of 1.03 g/㎠. The stepwedges of 0.03 and 0.05 mm produced results having higher values than the actual known bone density. They did not show the blue and green color level that appeared in lumbar on color enhanced image. Conclusion : A copper stepwedge of adequate thickness and range of steps which can express the range of density of bone being measured should be used.

  • PDF

A STUDY ON THE READABILITY OF PERIAPICAL RADIOGRAPH WITH THE DIGITAL RADIOGRAPHY (Digital radiography를 이용한 치근단 X선 사진의 판독능에 관한 실험적 연구)

  • Lee Kon;Lee Sang Rae
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.22 no.1
    • /
    • pp.117-127
    • /
    • 1992
  • This investigation was performed to test the readability of the video based digital radiography, that can be applied clinically, compared with the periapical radiograph. The experiments were performed with IBM-PC/AT compatible, video camera and ADC (analog-digital converter). And spatial resolution was 512 X 480 with 256 (8 bit) gray levels. The radiographs obtained by using variable steps of exposure time were digitized. and then the digital images were analyzed. The obtained results were as follows: 1. There was no remarkable difference in readability between the radiographs and their digital images. However, under over exposure the digital images were superior to the radiographs in readability and vice versa. 2. As the exposure time was increased, the gray level of the digital image was decreased proportionally. 3. The correlation beween the regions of interest and the aluminum step wedges were relatively close; R=0.9965 (p <0.001).

  • PDF

THIN-FILM-COATED DETECTORS FOR NEUTRON DETECTION

  • McGregor Douglas S.;Gersch Holly K.;Sanders Jeffrey D.;Klann Raymond T.;Lindsay John T.
    • Journal of Radiation Protection and Research
    • /
    • v.26 no.3
    • /
    • pp.167-175
    • /
    • 2001
  • Semiconductor diode detectors coated with neutron reactive material are presently under investigation for various uses, such as remote sensing of thermal neutrons, fast neutron counting, and thermal neutron radiography. Theory indicates that single-coated devices can yield thermal neutron efficiencies from 4% to 11 %, which is supported by experimental evidence. Radiation endurance measurements indicate that the devices function well up to a limiting thermal neutron fluence of $10^{13}/cm^2$, beyond which noticeable degradation occurs. Thermal neutron contrast images of step wedges and simple phantoms, taken with dual in-line pixel devices, show promise for thermal neutron imaging detectors.

  • PDF

Comparison of Heel Effect with Distance and Direction Change (거리와 방향 변화에 따른 힐이팩트 비교)

  • Kim, Hyung-Woo;Seok, Ji-Eun;Kang, Min-Yeong;Jo, Chan-Haeng;Jeon, Min-Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.4
    • /
    • pp.435-442
    • /
    • 2022
  • The heel effect creates a density difference in the X-ray images because the intensity of the anode and cathode side of the X-ray tube is not equal. The purpose of this study is to evaluate the density difference due to the heel effect by rotating the step wedge by 180 degrees and then changing the distance. After fixing the tube voltage and tube current to 72 kVp and 10 mAs, the forward and reverse directions were taken using a step wedge. At this time, the distance (80 cm ~ 130 cm) was taken at 10 cm intervals, and the density value was measured by setting the region of interest for each step of the step wedge through the M6 program. First, the difference in intensity between the anode and the cathode was confirmed through the radiation exposure test. In addition, when the distance (from 80 cm to 130 cm) was changed, the difference in density between the cathode and the anode decreased as the projection distance increased. As a result, images of uniform density can be obtained as the projection distance increases.

A COMPARATIVE STUDY ON RADIOPACITY OF ROOT CANAL SEALERS (근관 전색재의 방사선 불투과성에 관한 비교연구)

  • Kim, Tae-Min;Kim, Seo-Kyoung;Hwang, In-Nam;Hwang, Yun-Chan;Kang, Byung-Cheol;Yoon, Suk-Ja;Lee, Jae-Seo;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.34 no.1
    • /
    • pp.61-68
    • /
    • 2009
  • This study was performed to assess the radiopacity of a variety of root canal sealers according to the specification concerning root canal sealers. Ten materials including Tubli-$Seal^{TM}$. Kerr Pulp Canal $Sealer^{TM}$, AH $26^{(R)}$, AH $plus^{(R)}$, AH plus $jet^{TM}$, Ad sea $1^{TM}$. $Sealer^{TM}$, $NOGENOL^{TM}$, ZOB $seal^{TM}$, $Epiphany^{TM}$ and dentin were evaluated in this study. In the first part, densitometric reading of an each step of aluminum step wedge on occlusal film was performed at different voltage and exposure time. In the second part, ten specimens were radiographed simultaneously with an aluminum step wedges on the occlusal films under decided condition. The mean radiographic density values of the materials were transformed into radiopacity expressed equivalent thickness of aluminum (mm Al). The following results were obtained. 1. Among the various conditions, the appropriate voltage and exposure time that meet the requirement density was 60 kVp at 0.2 s 2. All of the materials had greater radiopacity than 3 mm Al requirement of ANSI/ADA specification No. 57 (2000) and ISO No. 6876 (2001) standards. 3. The radiopacity of materials increased as thickness of materials increased. 4. The mm Al value of each specimen at 1mm in thickness has a significant difference in the statistics. It suggests that root canal sealers have a sufficient radiopacity that meet the requirement.