• Title/Summary/Keyword: Step

Search Result 23,508, Processing Time 0.044 seconds

Implementation on SVM based Step Detection Analyzer (SVM 기반의 걸음 검출 분석기의 구현)

  • An, Kyung Ho;Kim, En Tae;Ryu, Uk Jae;Chang, Yun Seok
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.10
    • /
    • pp.1147-1155
    • /
    • 2013
  • In this study, we designed and implemented a step detection analyzer that can compare and analyze the step detection rates and results among the step detection algorithms. The step detection analyzer converts 3-axes accelerometer data into continuous energy stream through SVM operation, shows the horizontal comparison among the step detection results for each step detection algorithms, and can make elemental detection analyses. For these processes, the step detection analyzer presents the continuous energy stream as energy waveform, checks the peak values and time location of the detected steps with step detection algorithms, and gives visual interface to get some possible causes in cases of step detection miss. It can also give the threshold graph for each algorithm to check the threshold value on missed cases directly and can help to get more appropriate threshold values or other adjustable parameters in step detection algorithm. This step detection analyzer can be applied efficiently on performance enhancement of step detection algorithm, on deciding an appropriate algorithm for a specific step counter system in the various step counter filed operations.

Evaluation of the Prediction Performance of FDS Combustion Models for the CO Concentration of Gas Fires in a Compartment (구획실 내 가스연료 화재의 CO 농도에 대한 FDS 연소모델의 예측성능 평가)

  • Baek, Bitna;Oh, Chang Bo;Hwang, Chel-Hong;Yun, Hong-Seok
    • Fire Science and Engineering
    • /
    • v.32 no.1
    • /
    • pp.7-15
    • /
    • 2018
  • The prediction performance of combustion models in the Fire Dynamics Simulator (FDS) were evaluated by comparing with experiment for compartment propane gas fires. The mixture fraction model in the FDS v5.5.3 and Eddy Dissipation Concept (EDC) model in the FDS v6.6.3 were adopted in the simulations. Four chemical reaction mechanisms, such as 1-step Mixing Controlled, 2-step Mixing Controlled, 3-step Mixing Controlled and 3-step Mixed (Mixing Controlled + finite chemical reactions) reactions, were implemented in the EDC model. The simulation results with each combustion model showed similar level for the temperature inside the compartment. The prediction performance of FDS with each combustion model showed significant differences for the CO concentration while no distinguished differences were identified for the $O_2$ and $CO_2$ concentrations. The EDC 3-step Mixing Controlled largely over-predicted the CO concentration obtained by experiment and the mixture fraction model under-predicted the experiment slightly. The EDC 3-step Mixed showed the best prediction performance for the CO concentration and the EDC 2-step Mixing Controlled also predicted the CO concentration reasonably. The EDC 1-step Mixing Controlled significantly under-predict the experimental CO concentration when the previously suggested CO yield was adopted. The FDS simulation with the EDC 1-step Mixing Controlled showed difficulties in predicting the $CO_2$ concentration when the CO yield was modified to predict the CO concentration reasonably.

Multi-step growth of a-plane GaN epitaxial layer on r-plane sapphire substrate by HVPE method (HVPE를 이용하여 r-plane 사파이어 위에 multi-step으로 성장시킨 a-plane GaN 에피층의 특성 연구)

  • Lee, Won-Jun;Park, Mi-Seon;Jang, Yeon-Suk;Lee, Won-Jae;Ha, Ju-Hyung;Choi, Young-Jun;Lee, Hae-Yong;Kim, Hong-Seung
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.26 no.3
    • /
    • pp.89-94
    • /
    • 2016
  • In this study, the crystalline property of a-plane GaN epitaxial layer grown on r-plane sapphire by a HVPE method has been investigated according to the V/III ratio and the growth time of multi-step growth. Furthermore, these results were compared with the previous result obtained from the single-step growth of a-plane GaN on r-plane sapphire substrate. In the multi-step growth for a-plane GaN epitaxial layer on r-plane sapphire, the FWHM values of rocking curve in GaN epitaxial layer were decreased as the HCl source flow rate and the growth time were increased. The void formed in epitaxial layer was continuously decreased as the growth time in first step and second step using a higher HCl flow rate was increased. As a result, the GaN layer obtained with the longest growth time on the first step and second step exhibited the lowest FWHM values of 584 arcsec and the smallest dependence of azimuth angle.

Measurement of Molecular Weights of Melamine-Urea-Formaldehyde Resins and Their Influences to Properties of Medium Density Fiberboards

  • Jeong, Bora;Park, Byung-Dae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.44 no.6
    • /
    • pp.913-922
    • /
    • 2016
  • This study attempted to measure molecular weight (MW) of melamine-urea-formaldehyde (MUF) resins prepared by two different synthesis methods: the one-step MUF resins were synthesized in one batch procedure, while the two-step MUF resins were prepared by a physical mixing of urea-formaldehyde (UF) resin with melamine-formaldehyde (MF) resin that had been synthesized in a separate procedure. The properties of medium density fiberboard (MDF) panels bonded with two types of MUF resins were also investigated. MWs of these MUF resins were measured using gel permeation chromatography (GPC). In addition, this study measured the MWs of one-step MUF resin during its synthesis procedure. The performance of two types of MUF resins was evaluated by determining properties of MDF panels prepared in laboratory. As the synthesis procedure progressed, both number average MW ($M_n$) and weight average MW ($M_w$) of one-step MUF resin gradually increased, while the polydispersity index (PDI) decreased. And low Mw species of the resin predominantly decreased as the synthesis step progressed. The one-step MUF resin showed greater $M_n$ and $M_w$ than those of the two-step ones even though the PDI values of both resins were very similar each other. As expected, the one-step MUF resin resulted in better properties of MDF panels than those of two-step resins. In particular, the one-step MUF resin provided better internal bond (IB) strength and thickness swelling (TS) with MDF panels than those of two-step ones, indicating better water resistance of the one-step resin. These results suggest that the preparation method of MUF resins have a great impact on the MW and final panel properties.

A Study on the improvement of treatment efficiency in a conventional sewage treatment plant (기존 하수처리장에서의 처리 효율개선에 관한 연구)

  • 안철우;박진식;문추연
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.3
    • /
    • pp.50-56
    • /
    • 2000
  • In this study, sewage were treated with operating Two-step Aeration System and conventional activated sludge process together in a condition. At the same HRT 8hr of Two-step Aeration System and Activated Sludge Process, BOD treatment efficiency of 1st sedimentation basin effluent 36.9% by Two-step Aeration system was 12.3% higher than 24.65 by Activated Sludge Process and the COD treatment efficiency 39.8% by two-step Aeration System was 11.6.3% higher than 28.2% by Activated Sludge Process. BOD and COD treatment efficiencies of 2nd sedimentation basin effluent were 88.1% and 85.6% Two-step Aeration System and were 83.8% and 82.3% Activated Sludge Process. In the first treatment, as BOD was relatively removed a lot, F/M ratio 0.17, $0.21{\cdot}BOD/kg{\cdot}MLSS.d$ was maintained by Activated Sludge Process. Therefore it was proved that organic matter treatment efficiency by Two-step Aeration System os Higher than by Activated Sludge Process in a aeration time 8hr. $NH_4^{+}-N$ treatment efficiencies were 55.5% by Two-step Aeration System and 39.75 by Activated sludge Process. $NO_3^{-}-N$ concentration in 2nd. sedimentation basin effluent were 3.33% by Two-step Aeration System and 2.36% by Activated Sludge Process. From this result, Two-step Aeration System was proved more advantageous treatment process for nitrification than Activated Sludge Process. The fluctuation range of BOD, COD and SS concentration in 2nd sedimentation basin effluent $16~33mg/{\ell}$, $15~23mg/{\ell}$ and $14~22mg/{\ell}$ by Two-step Aeration System was smaller than $16~57mg/{\ell}$, $15~25mg/{\ell}$ by Activated sludge Process. Overall the fluctuation range in 2nd sediment basin effluent by was smaller than by Activated Sludge Process. As a result, it is possible for this Two-step Aeration with no facility investment and a little of operation condition change in a conventional sewage treatment plant to get stability and nitrification of treatment water quality.

  • PDF

A Study on the Out-of-Step Detection Algorithm using Time Variation of Complex Power-Part II : Out-of-Step Detection Algorithm using a trajectory of Complex power (복소전력의 변화율을 이용한 동기탈조 검출 알고리즘에 관한 연구-Part II: 복소전력의 궤적 변화를 이용한 동기탈조 검출 알고리즘)

  • Kwon, O.S.;Kim, C.H.;Park, N.O.;Chai, Y.M.
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.313-315
    • /
    • 2005
  • In a power system, an out-of-step condition causes a variety of risk such as serious damage to system elements, tripping of loads and generators, mal-operation of relays, etc. Therefore, it is very important to detect the out-of-step condition and take a proper measure. Several out-of-step detection methods have been employed in relays until now Mo,;t common method used for an out-of-step detection is based on the transition time through the blocking impedance area in R-X diagram. Also, the R-R dot out-of- step relay, the out-of-step prediction method and the adaptive out-of-step relay using the equal area criterion (EAC) and Global Positioning Satellite (GPS) technology have been developed. This paper presents the out-of-step detection algorithm using the time variation of the complex power. The complex power is calculated and the mechanical power of the generator is estimated by using the electrical power, and then the out-of-step detection algorithm, which is based on the complex Power and the estimated mechanical power, is presented. This algorithm, may detect the instant when the generator angle passes the Unstable Equilibrium Point (UEP). The proposed out-of-step algorithm is verified and tested by using Alternative Transient Program/Electromagnetic Transient Program (ATP/EMTP) MODELS.

  • PDF

PC Based STEP-NC Milling Machine Operated by STEP-NC in XML Format (XML형식의 STEP-NC파일로 구동되는 PC 기반의 STEP-NC milling machine)

  • 이원석;방영봉
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.12
    • /
    • pp.185-193
    • /
    • 2002
  • Most of NC machines are operated by Is06983 standard called G-code, which was developed in the early days of machine tools. This G-code limits hardware performance of the currently developed high-performance hardware & machine tools. By describing only movements of tool, almost all of information of previous production departments is lost, and the machining department cannot exchange information with other departments. For adjusting new hardware environment and direct communication of CNC machines with CAD/CAM software, ISO 14649, STEP -NC is researched. This new standard stores CAD/CAM information as well as operation commands of CNC machines. In this research, the new CNC machine operated by STEP-NC was built and tested. Unlike other STEP-NC milling machines, this system uses the STEP-NC file in form of XML as data input. It makes possible for STEP-NC machines to exchange information to other databases using XML. The mentioned system of this paper loads the XML file, analyzes it, makes tool paths of two5D features with information of STEP-NC, and machines automatically without making G-code. All of software is programmed with Visual C++, and the milling machine is made with table milling machine, step motors, and motion control board for PC that can be directly controlled by C++ commands. All modules of software and hardware were independent, it allows convenient for substitution and expansion of the milling machine. The example 1 in ISP14649-11 that had all information about geometry and machining and the example 2 that has only geometry and tool information were used to test automatic machining by the open-architecture milling machine.

Effects of Osmolality Step during Vitrification on Survival of Vitrified IVP Embryos in Korean Native Cattle (Hanwoo)

  • Yoo, Han-Jun;Choi, Hye-Won;Cheong, Ki-Soo;Kim, Ji-Tae;Lee, Chang-Woo;Park, Choon-Keun;Park, Joung-Jun
    • Journal of Embryo Transfer
    • /
    • v.27 no.4
    • /
    • pp.259-264
    • /
    • 2012
  • Solution of glycerol, ethylene glycol, sucrose, dextrose (GESD) and cryotop methods were carried out to investigate the survivability on vitrification of embryos. Embryos cultured in vitro were vitrified by GESD of 10 or 8 step and cryotop methods of 6 step, from cryopreservation step to frozen-thawed and culture step. Survival rate and ICM, TE cells of embryos were investigated after frozen-thawed 24 h. As a results, cryotop method was significantly (p<0.05) higher ($85.76{\pm}5.3$ vs. $66.71{\pm}2.4$, $44.80{\pm}2.1%$) than GESD 10 or 8 step methods on survivability. Also, In ICM cell number, cryotop method was significantly (p<0.05) higher to $45.67{\pm}4.7$ cells than GESD 8 step method. TE cell number was significantly (p<0.05) highest to $111.00{\pm}11.0$ cells in cryotop method. On the other hand, survival rate, TE and total cell number were all the significantly (p<0.05) high, except ICM in GESD 10 step method between GESD 10 step method and GESD 8 step method. In conclusion cryotop method was to be most effective, but it is considered necessary to study vitrification method for step-by-step freezing and thawing process.