코팅 용액의 조성 최적화 및 코발트-크롬 금속스텐트의 화학적 표면개질을 통한 친수성 천연 고분자 코팅층의 표면 거칠기 개선 (Improving Smoothness of Hydrophilic Natural Polymer Coating Layer by Optimizing Composition of Coating Solution and Modifying Chemical Properties of Cobalt-Chrome Stent Surface)

  • 김대환;금창헌
    • 한국키틴키토산학회지
    • /
    • 제23권4호
    • /
    • pp.256-261
    • /
    • 2018
  • Recently, the number of cardiovascular disease-related deaths worldwide has increased. Therefore, the importance of percutaneous cardiovascular intervention and drug-eluting stents (DES) has been highlighted. Despite the great clinical success of DES, the re-endothelialization at the site of stent implantation is retarded owing to the anti-proliferative effect from the coated drug, resulting in late thrombosis or very late restenosis. In order to solve this problem, studies have been actively carried out to excavate new drugs that promote rapid re-endothelialization. In this study, we introduced hydrophilic drug, tauroursodeoxycholate (TUDCA), that improves the proliferation of endothelial progenitor cells and promotes apoptosis of vascular smooth muscle cells. In addition, we utilized shellac, which is a natural resin from lac bug to coat TUDCA on the surface of the metal. When using conventional coating method including biodegradable polymers and organic solvents, phase separation between polymer and drug occurred in the coating layer that caused incomplete incorporation of drug into the polymer layer. However, when using shellac as a coating polymer, no phase separation was observed and drug was fully covered with the polymer matrix. In addition, by adjusting the composition of coating solution and modifying the hydrophilicity of the metal surface using oxygen plasma, the surface roughness decreased due to the increased affinity between coating solution and metal surface. This result provides a method of depositing a hydrophilic drug layer on the stent.

정상유동에서 자가팽창성 그래프트 스텐트의 수력학적 특성 (Hydrodynamic Characteristics of Self-expandable Graft Stents in Steady Flow)

  • 이홍철;김철생;박복춘;박복춘
    • 대한의용생체공학회:의공학회지
    • /
    • 제24권1호
    • /
    • pp.37-44
    • /
    • 2003
  • 본 실험연구에서는 정상유동상태에서 새롭게 설계된 자가팽창성 그래프트 스텐트의 수력학적 성능을 평가하고자 하였다. 코팅 재질이 다른 두 개의 그래프트 스텐트와 한 개의 타이티놀 금속스텐트가 실험에 사용되었으며, 유량이 가자 5, 10, 15 1/min에서 스텐트 전후에서의 압력변화 및 속도분포를 측정하였다. 스텐트 삽입에 의한 압력손실은 유량이 증가함에 지수적으로 증가하였다. 특히 15 1/min의 유량에서 다공성 PTFE 그래프트 스텐트와 TiNi 금속스텐트의 압력손실은 거의 동일하나 PU 그래프트 스텐트는 약 6배 이상의 현저한 증가를 보이고 있다. 스텐트 후류에서의 속도분포는 다공성 PTFE 그래프트 스텐트와 TiNi 금속스텐트는 유량에 관계없이 유사한 형태를 보여주고 있다. 그러나, PU 그래프트 스텐트에서는 특히 유량이 10 1/min 이상에서 속도분포가 비대칭적이고 관 중심에서의 상대적인 낮은 유속을 보여주고 있으며, 결과적으로 벽면전단응력 및 수직응력의 증가론 초래하고 있다. 이와같이 PU 그래프트 스텐트의 상대적으로 낮은 수력학적 성능은 스텐트가 보다 작은 관에 삽입되었을때 코팅재질의 낮은 유연성으로 인하여 스텐트의 표면에 주름이 발생하여 유동단면이 비대칭적으로 되고 벽면의 조도가 증가하며, 관벽과 스텐트와 틈새가 존재하여 제트류가 형성되기 때문으로 해석된다.

Co-Cr alloy의 전해연마에 따른 부식의 영향 (Effect of Electropolishing Process on Corrosion Resistance of Co-Cr Alloy)

  • 박제민;김완철
    • 한국표면공학회지
    • /
    • 제43권4호
    • /
    • pp.199-204
    • /
    • 2010
  • The Co-Cr alloys have clinical histories as dental and orthopaedic implants, and recently as cardiovascular stent applications because they exhibit a high elastic modulus and radiopacity. In order to improve their mechanical and corrosion resistance, electropolishing is employed as the final process. Electropolishing, an anodic dissolution process in the transpassive state, is sensitively affected by process conditions such as current density, machining time, and electrode gap. In this study, the effect of the electropolishing conditions on surface roughness and corrosion resistance is investigated for Co-Cr alloys (L605). The most smooth surface is obtained when electropolishing is performed at 15-20 V for 15-30 sec with a electrode gap of 3.5 mm. It is found out that electropolishing reduces corrosion rate about one-tenth as much.

Co-Cr alloy의 열처리에 따른 표면개질의 영향 (Effect of Surface Modification by Heat Treatment of Co-Cr Alloy)

  • 박제민;김완철
    • 열처리공학회지
    • /
    • 제23권3호
    • /
    • pp.137-141
    • /
    • 2010
  • The Co-Cr alloys have clinical histories in dental and orthopaedic implants, and recently in cardiovascular stent applications because the alloys exhibit a high elastic modulus and radiopacity. In order to improve mechanical property of the Co-Cr alloys, electropolishing is employed as the final process. Electropolishing, an anodic dissolution process in the transpassive state, is sensitively affected by process conditions such as current density, machining time, electrode gap. In this study, the effect of heat treatment conditions on surface roughness and inclusion analysis is investigated in Co-Cr alloy (L605). The most smooth surface of Co-Cr alloy is obtained when electropolishing is performed at 15-20 V for 15-30 sec with a electrode gap of 3.5 mm.

나이티놀 스텐트 와이어의 기계적 특성 향상을 위한 초음파 나노표면 개질 처리에 대한 연구 (Application of Ultrasonic Nano Crystal Surface Modification into Nitinol Stent Wire to Improve Mechanical Characteristics)

  • 김상호;서태석;이창순;박인규;조인식;편영식;김성현
    • 한국의학물리학회지:의학물리
    • /
    • 제20권2호
    • /
    • pp.80-87
    • /
    • 2009
  • 비혈관 스텐트(식도용, 담도용, 대장용, 십이지장용, 기관지용) 재질로 가장 널리 사용되고 있는 Nitinol wire 형상기억합금의 기계적 특성 향상을 위해 초음파 나노표면 개질(UNSM) 기술을 적용하여 Nitinol wire의 상변화와 초탄성 특성 및 표면 잔류응력 등의 변화를 연구하였으며, 탄력에너지와 부식내구성을 통한 스텐트의 수명 연장방법을 연구하고자 하였다. 본 연구에 사용된 Nitinol wire는 ${\phi}1.778$ mm로 UNSM 처리 전후의 표면거칠기 값은 Ra=0.092${\mu}m$와 Ra=0.093${\mu}m$로 비슷 하였지만, 초기시편에서는 미세결함과 인발가공 흔적이 확연히 관찰되었으나, UNSM 후에는 인발가공 흔적과 미세 표면 결함은 사라진 것이 발견되었다. 또한 잔류응력 측정 결과, 초기 시험편에는 +3.65 MPa였으나 UNSM 처리 후에는 -4.09 MPa로 확인되었으며, XRD를 통한 결정구조 분석 결과 $42.28^{\circ}$에서 초기보다 약한 (110) 오스테나이트 피크가 관찰되었으며, 대신 (020), ($1{\overline{1}}1$), 그리고 (021) 피크가 명확히 Martensite (B19' Monoclinic lattices) 구조로 확인되었고, (300)의 R상 (Rhombohedral lattices)에 대한 추가 피크가 미비하게 관찰되었다. 탄성변형에 따른 에너지 흡수력과 하중 제거에 따른 에너지의 회복력인 탄력계수(modulus of resilience) $U_r$은 단위체적당 변형률 에너지로 4.31 $MJ/m^3$에서 5.85 $MJ/m^3$로 증가하였다. 이와 같이 표면결함 제거와 인장응력을 압축응력으로 재편성하는 것만으로도 피로내구성을 크게 향상시킬 수 있다고 사료되며, 생체적합성과 더불어 내부식성, 내마모성 및 내구수명 향상을 실용화할 수 있는 표면개질 장치가 개발된다면, 현재 한국인 사망원인 1위인 순환계 질환(심근경색, 뇌졸중 등)에 사용되는 혈관계통의 스텐트 개발에도 응용개발연구가 가능할 것으로 예상된다.

  • PDF

생분해성 고분자의 전기분사를 이용한 약물방출 스텐트용 금속표면 코팅 및 ALA방출 거동 (Metal Surface Coating Using Electrospray of Biodegradable Polymers and $\alpha$-Lipoic Acid Release Behavior for Drug-Eluting Stents)

  • 김동민;이봉수;박철호;박귀덕;손태일;정명호;한동근
    • 폴리머
    • /
    • 제34권2호
    • /
    • pp.178-183
    • /
    • 2010
  • 의료용 금속스텐트는 관상동맥계 심장질환을 앓고 있는 환자에 시술되어 상대적으로 생존율을 높여 준다. 그러나, 재협착 및 후기 혈전증으로 인하여 새로운 스텐트의 개발이 시급하게 되었다. 이러한 문제점을 해결하기 위해서 신생내막 과대증식을 막을 수 있는 것으로 알려진 alpha lipoic acid(ALA)를 생분해성 고분자인 poly(lactide-coglycolide)(PLGA), poly(L-lactide)(PLLA) 및 poly($\varepsilon$-caprolactone)(PCL)과 혼합하여 전기분사 방식으로 스테인레스 스틸 표면 위에 코팅하였다. 코팅된 고분자로부터 약물방출 거동은 고분자의 종류와 농도, 용출속도 및 용매의 종류에 따라서 조사하였다. 약물방출 속도는 유리전이온도($T_g$)가 낮은 PCL에서 가장 빨랐으며 PLGA, PLLA 순서를 보였다. 고분자 표면의 거친정도는 용출속도가 증가함에 따라서 증가하였고, 용매의 비등점의 차이에 의해서 약물방출속도가 변화됨을 알 수 있었다. 이러한 약물방출 거동을 조절함으로써 ALA가 담지된 생분해성 고분자로 코팅된 약물방출 스텐트를 실제 임상적용이 가능할 것으로 기대된다.