• 제목/요약/키워드: Stent retriever

검색결과 13건 처리시간 0.018초

Effectiveness and Technical Considerations of Solitaire Platinum 4×40 mm Stent Retriever in Mechanical Thrombectomy with Solumbra Technique

  • Yi, Ho Jun;Sung, Jae Hoon;Lee, Dong Hoon;Song, Seung Yoon
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권1호
    • /
    • pp.30-38
    • /
    • 2021
  • Objective : The Solitaire Platinum 4×40 mm stent retriever contains radiopaque markers with a long length. We evaluated the effect of Solitaire Platinum 4×40 mm stent retriever in Solumbra technique thrombectomy, and compared it with shorter Solitaire stent retrievers. Methods : A total of 70 patients who underwent Solumbra technique thrombectomy with equal diameter (4 mm) and different length (40 vs. 20 mm) Solitaire stent retrievers were divided into two groups : the Solitaire Platinum 4×40 mm stent (4×40) group and the Solitaire FR 4×20 mm stent or Solitaire Platinum 4×20 mm stent (4×20) group. The clinical outcomes, Thrombolysis in Cerebral Infarction score, the first pass reperfusion status, and complications were evaluated and compared between the two groups. Multivariate analysis was performed to evaluate the predictive factors for reperfusion and complete reperfusion from the first pass. Results : Higher first-pass reperfusion and complete reperfusion were achieved in the 4×40 group (68.0% and 48.0%) than in the 4×20 group (46.7% and 33.3%; p=0.004 and 0.007, respectively). In multivariate analysis, radiopaque device and longer stent retriever were correlated with first-pass reperfusion (p=0.014 and 0.008, respectively) and first-pass complete reperfusion (p=0.022 and 0.012, respectively). Conclusion : Our study demonstrated the usefulness of the Solitaire Platinum 4×40 mm stent retriever, which led to higher first-pass reperfusion and complete reperfusion rates than the Solitaire FR 4×20 mm stent or the Solitaire Platinum 4×20 mm stent, especially in Solumbra technique thrombectomy.

Effectiveness of Anchoring with Balloon Guide Catheter and Stent Retriever in Difficult Mechanical Thrombectomy for Large Vessel Occlusion

  • Yi, Ho Jun;Kim, Bum-Tae;Shin, Dong-Sung
    • Journal of Korean Neurosurgical Society
    • /
    • 제65권4호
    • /
    • pp.514-522
    • /
    • 2022
  • Objective : A distal navigation of a large bore aspiration catheter during mechanical thrombectomy (MT) is important. However, delivering a large bore aspiration catheter is difficult to a tortuous or atherosclerotic artery. We report the experience of anchoring with balloon guide catheter (BGC) and stent retriever to facilitate the passage of an aspiration catheter in MT. Methods : When navigating an aspiration catheter failed with a conventional co-axial microcatheter delivery, an anchoring technique was used. Two types of anchoring technique were applied to facilitate distal navigation of a large bore aspiration catheter during MT. First, a passage of aspiration catheter was attempted with a proximal BGC anchoring technique. If this technique also failed, another anchoring technique with distal stent retriever was tried. Consecutive patients who underwent MT with an anchoring technique were identified. Details of procedure, radiologic outcomes, and safety variables were evaluated. Results : A total of 67 patients underwent MT with an anchoring technique. Initial trial of aspiration catheter passage with proximal BGC anchoring technique was successful for 35 patients (52.2%) and the second trial with distal stent retriever anchoring was successful for 32 patients (47.8%). Overall, navigation of a large bore aspiration catheter was successful for all patients (100%) without any procedure related complications. Conclusion : Our study showed the usefulness of anchoring technique with proximal BGC and distal stent retriever during MT, especially in those with an unfavorable anatomical structure. This technique could be an alternative option for delivering an of aspiration catheter to a distal location.

Endovascular Stroke Therapy Focused on Stent Retriever Thrombectomy and Direct Clot Aspiration : Historical Review and Modern Application

  • Kang, Dong-Hun;Park, Jaechan
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권3호
    • /
    • pp.335-347
    • /
    • 2017
  • Intravenous recombinant tissue plasminogen activator had been the only approved treatment for acute ischemic stroke since its approval in 1995. However, the restrictive time window, numerous contraindications, and its low recanalization rate were all limitations of this modality. Under those circumstances, endovascular stroke therapy went through a great evolution during the past two decades of intravenous thrombolysis. The results of the 2013 randomized trials for endovascular stroke therapy were neutral, although they were limited by insufficient imaging screening at enrollment, early-generation devices with less efficacy, and treatment delays. Huge progress was made in 2015, as there were five randomized clinical trials which all demonstrated the safety and efficacy of endovascular stroke treatment. Despite differences in detail patient enrollment criteria, all 5 trials employed key factors for good functional recovery; (1) screening with non-invasive imaging to identify the proximal occlusion and exclude a large infarct core, (2) using highly effective modern thrombectomy devices mainly with stent retriever, and (3) establishment of a fast workflow to achieve effective reperfusion. The results of those trials indicate that modern thrombectomy devices can allow for faster and more effective reperfusion, which can lead to improved clinical outcomes compared to intravenous thrombolysis alone. These advances in mechanical thrombectomy are promising in the global fight against ischemic stroke-related disability and mortality. Two current mainstreams among such mechanical thrombectomy techniques, "stent retriever thrombectomy" and "direct clot aspiration", are the topic of this review. Stent retriever thrombectomy using Solitaire and Trevo retriever will be firstly discussed. And, the commonalities and the differences between two major clot aspiration thrombectomy techniques; a direct aspiration first pass technique (ADAPT) and forced arterial suction thrombectomy (FAST), will be additionally explained. Finally, details regarding the combination of direct clot aspiration and stent retriever thrombectomy, the switching strategy and the Solumbra technique, will be described.

Comparative Analysis of Endovascular Stroke Therapy Using Urokinase, Penumbra System and Retrievable (Solitare) Stent

  • Choi, Jae-Hyung;Park, Hyun-Seok;Kim, Dae-Hyun;Cha, Jae-Kwan;Huh, Jae-Taeck;Kang, Myongjin
    • Journal of Korean Neurosurgical Society
    • /
    • 제57권5호
    • /
    • pp.342-349
    • /
    • 2015
  • Background : Higher reperfusion rates have been established with endovascular treatment for acute ischemic stroke patients. There are limited data on the comparative performance of mechanical thrombectomy devices. This study aimed to analyse the efficacy and safety of the stent retriever device (Solitaire stent) by comparing procedure time, angiographic outcome, complication rate and long term clinical outcome with previous chemical thrombolysis and mechanical thrombectomy using penumbra system. Method : A retrospective single-center analysis was undertaken of all consecutive patients who underwent chemical thrombolysis and mechanical thrombectomy using Penumbra or Solitaire stent retriever from March 2009 to March 2014. Baseline characteristics, rate of successful recanalization (modified Thrombolysis in Cerebral Infarction score 2b-3), symptomatic intracerebral hemorrhage, procedure time, mortality and independent functional outcomes ($mRS{\leq}2$) at 3 month were compared across the three method. Results : Our cohort included 164 patients, mechanical thrombectomy using stent retriever device had a significant impact on recanalization rate and functional independence at 3 months. In unadjusted analysis mechanical thrombectomy using Solitaire stent retriever showed higher recanalization rate than Penumbra system and chemical thrombolysis (75% vs. 64.2% vs. 49.4%, p=0.03) and higher rate of functional independence at 3 month (53.1% vs. 37.7% vs. 35.4%, p=0.213). In view of the interrelationships between all predictors of variables associated with a good clinical outcome, when the chemical thrombolysis was used as a reference, in multiple logistic regression analysis, the use of Solitaire stent retriever showed higher odds of independent functional outcome [odds ratio (OR) 2.62, 95% confidence interval (CI) 0.96-7.17; p=0.061] in comparison with penumbra system (OR 1.57, 95% CI 0.63-3.90; p=0.331). Conclusion : Our initial data suggest that mechanical thrombectomy using stent retriever is superior to the mechanical thrombectomy using penumbra system and conventional chemical thrombolysis in achieving higher rates of reperfusion and better outcomes. Randomized clinical trials are needed to establish the actual benefit to specific patient populations.

Effectiveness and Safety of Mechanical Thrombectomy with Stent Retrievers in Basilar Artery Occlusion : Comparison with Anterior Circulation Occlusions

  • Hu, Soo Young;Yi, Ho Jun;Lee, Dong Hoon;Hong, Jae Taek;Sung, Jae Hoon;Lee, Sang Won
    • Journal of Korean Neurosurgical Society
    • /
    • 제60권6호
    • /
    • pp.635-643
    • /
    • 2017
  • Objective : Acute basilar artery occlusion (BAO) is associated with severe neurological dysfunction and high mortality rates. The benefits of mechanical thrombectomy in BAO have not been explored in recent clinical trials. Therefore, we analyzed outcomes of stent retriever mechanical thrombectomy for BAO, and compared with anterior circulation occlusions (ACO). Methods : In total, 161 consecutive patients (24 BAO, 137 ACO) who underwent mechanical thrombectomy with the stent retriever between January 2013 and August 2016 enrolled in our study. All patients underwent clinical assessment with the National Institutes of Health Stroke Scale (NIHSS) and modified Rankin scale (mRS). Radiological results were used to evaluate thrombolysis in cerebral infarction (TICI) scores and successful recanalization was defined by TICI 2b or 3. Results : Mean NIHSS scores at 24 hours and 30 days were significantly higher in the BAO group than the ACO group (p=0.021, p=0.001). mRS at 90 days was significantly higher in the BAO group (4.2) compared with the ACO group (3.0) (p=0.003). The BAO group (2.0) performed fewer stent retriever passages than the ACO group (2.7) (p=0.049). There were no significant differences between the two groups in terms of complications, but the BAO patients experienced a higher mortality (16.6%) rate than ACO patients (5.8%) (p=0.001). In subgroup analysis of BAO, patients with short procedure times achieved successful recanalization (p=0.001) and successfully recanalized patients exhibited more favorable mRS at 90 days (p=0.027). Conclusion : In our study, mechanical thrombectomy of BAO patients showed worse clinical outcome and higher mortality rate than ACO patients. However, mechanical thrombectomy with a stent retriever in BAO is an effective treatment, because successfully recanalized patients showed good clinical outcome in BAO patients.

Efficacy of Combining Proximal Balloon Guiding Catheter and Distal Access Catheter in Thrombectomy with Stent Retriever for Anterior Circulation Ischemic Stroke

  • Kim, Sang Hwa;Choi, Jae Hyung;Kang, Myung Jin;Cha, Jae Kwan;Kim, Dae Hyun;Nah, Hyun Wook;Park, Hyun Seok;Kim, Sang Hyun;Huh, Jae Taeck
    • Journal of Korean Neurosurgical Society
    • /
    • 제62권4호
    • /
    • pp.405-413
    • /
    • 2019
  • Objective : We evaluated efficacy of combining proximal balloon guiding catheter (antegrade flow arrest) and distal access catheter (aspiration at the site of occlusion) in thrombectomy for anterior circulation ischemic stroke. Methods : We retrospectively analyzed 116 patients who underwent mechanical thrombectomy with stent retriever. The patients were divided by the techniques adopted, the combined technique (proximal balloon guiding catheter and large bore distal access catheter) group (n=57, 49.1%) and the conventional (guiding catheter with stent retriever) technique group (n=59, 50.9%). We evaluated baseline characteristics (epidemiologic data, clinical and imaging characteristics) and procedure details (the number of retrieval attempts, procedure time), as well as angiographic (thrombolysis in cerebral infarction (TICI) score, distal thrombus migration) and clinical outcome (National Institutes of Health Stroke Scale at discharge, modified Rankin Scale [mRS] at 3 months) of them. Results : The number of retrieval attempts was lower (p=0.002) and the first-pass successful reperfusion rate was higher (56.1% vs. 28.8%; p=0.003) in the combined technique group. And the rate of final result of TICI score 3 was higher (68.4% vs. 28.8%; p<0.01) and distal thrombus migration rate was also lower (15.8% vs. 40.7%; p=0.021) in the combined technique group. Early strong neurologic improvement (improvement of National Institutes of Health Stroke Scale ${\geq}11$ or National Institutes of Health Stroke Scale ${\leq}1$ at discharge) rate (57.9% vs. 36.2%; p=0.02) and favorable clinical outcome (mRS at 3 months ${\leq}2$) rate (59.6% vs. 33.9%; p=0.005) were also better in the combined technique group. Conclusion : The combined technique needs lesser attempts, decreases distal migration, increases TICI 3 reperfusion and achieves better clinical outcomes.

The Protective Effects of Statins towards Vessel Wall Injury Caused by a Stent Retrieving Mechanical Thrombectomy Device : A Histological Analysis of the Rabbit Carotid Artery Model

  • Lee, Seung Hwan;Shin, Hee Sup;Oh, Inho
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권5호
    • /
    • pp.693-704
    • /
    • 2021
  • Objective : Endovascular mechanical thrombectomy (MT) has been regarded as one of the standard treatments for acute ischemic stroke caused by large vessel occlusion. Despite the wide use of stent retrievers for MT, arterial intimal damage caused when deployed stent is pulled has been a certain disadvantage. We hypothesized that statin could protect and stabilize vessel damage after endovascular MT using a stent retriever. In this animal study, we observed the protective effects of the statins towards MT-induced vessel wall injury. Methods : Twenty-eight carotid arteries of fourteen rabbits were used in the experiments with MT using stent retriever. We divided the rabbits into four groups as follows : group 1, negative control; group 2, positive control; group 3, statin before MT; and group 4, statin after MT. After MT procedures, we harvested the carotid arteries and performed histomorphological and immunohistochemical analyses. Results : In histomorphological analysis with hematoxylin and eosin and Masson's trichrome stain, significant intimal thickening (p<0.05) was observed in the positive control (group 2), compared to in the negative control (group 1). Intimal thickening was improved in the statin-administered groups (groups 3 and 4 vs. group 2, p<0.05). We also observed that statin administration after MT (group 4) resulted in a more effective decrease in intimal thickness than statin administration before MT (group 3) (p<0.05). We performed immunohistochemical analysis with the antibodies for tumor necrosis factor-alpha (TNF-α), cluster of differentiation (CD)11b, and CD163. In contrast to the negative control (group 1), the stained percentage areas of all immunological markers were markedly increased in the positive control (group 2) (p<0.05). Based on statin administration, the percentage area of TNF-α staining was significantly reduced (p<0.05) in group 3, compared to the positive control group (group 2). However, significant differences were not observed for CD11b and CD163 staining. In group 4, no significant differences were observed for TNF-α, CD11b, and CD163 staining (p≥0.05). The differences in the percentage areas of the different markers between the statin-administered groups (groups 3 and 4) were also not revealed. Conclusion : We presented that statin administration before and after MT exerted protective effects towards vessel wall injury. The efficacy of statins was greater post-administration than pre-administration. Thus, statin administration in routine prescriptions in the peri-procedural period is strongly advised.

Current Opinion on Endovascular Therapy for Emergent Large Vessel Occlusion Due to Underlying Intracranial Atherosclerotic Stenosis

  • Dong-Hun Kang;Woong Yoon
    • Korean Journal of Radiology
    • /
    • 제20권5호
    • /
    • pp.739-748
    • /
    • 2019
  • For recanalization of emergent large vessel occlusions (ELVOs), endovascular therapy (EVT) using newer devices, such as a stent retriever and large-bore catheter, has shown better patient outcomes compared with intravenous recombinant tissue plasminogen activator only. Intracranial atherosclerotic stenosis (ICAS) is a major cause of acute ischemic stroke, the incidence of which is rising worldwide. Thus, it is not rare to encounter underlying ICAS during EVT procedures, particularly in Asian countries. ELVO due to underlying ICAS is often related to EVT procedure failure or complications, which can lead to poor functional recovery. However, information regarding EVT for this type of stroke is lacking because large clinical trials have been largely based on Western populations. In this review, we discuss the unique pathologic basis of ELVO with underlying ICAS, which may complicate EVT procedures. Moreover, we review EVT data for patients with ELVO due to underlying ICAS and suggest an optimal endovascular recanalization strategy based on the existing literature. Finally, we present future perspectives on this subject.

Aspiration-Retriever Technique for Stroke with Large Bore Intermediate Catheter : A Single Center Experience

  • Nam, Ji Won;Jung, Na Young;Park, Eun Suk;Kwon, Soon Chan
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권5호
    • /
    • pp.732-739
    • /
    • 2021
  • Objective : Early successful reperfusion is associated with favorable outcomes in acute ischemic stroke (AIS). The purpose of this study was to achieve successful recanalization by a combined mechanical thrombectomy technique, the Aspiration-Retriever Technique for Stroke (ARTS), which is composed of a flexible large lumen distal access catheter and a retrievable stent as the first-line strategy of mechanical thrombectomy. Methods : We retrospectively reviewed 62 patients with AIS who underwent mechanical thrombectomy from 2018 to 2019 at our institute by a senior neurointerventionalist. Among them, patients who were treated using the ARTS technique with the soft torqueable catheter optimized for intracranial access (SOFIA®; MicroVention-Terumo, Tustin, CA, USA) as the first-line treatment were included. Patients who had tandem occlusions or underlying intracranial artery stenosis were excluded. The angiographic and clinical outcomes were evaluated. The angiographic outcome was analyzed by the rate of successful recanalization, defined as a Thrombolysis in Cerebral Infarction score of 2b or 3 at the end of all procedures and the rate of successfully achieving the first pass effect (FPE), defined as complete recanalization with a single pass of the device. The clinical outcomes included the National Institutes of Health Stroke Scale (NIHSS) score, modified Rankin Scale (mRS), and mortality. Results : A total of 27 patients (mean age, 59.3 years) fulfilled the inclusion criteria. The successful recanalization rate was 96% (n=26) while the FPE rate was 41% (n=11). The mean post-procedural NIHSS change was -3.0. Thirteen patients (48%) showed good clinical outcomes after thrombectomy with the ARTS technique (mRS at 90 days ≤2). Postoperative complications occurred in seven of 25 patients : hemorrhagic transformation in six patients (22%) and distal embolization in one patient (4%). Mortality was 15% (n=4). Conclusion : Although the clinical outcomes using the ARTS technique with a flexible large lumen distal access catheter performed as the frontline thrombectomy in patients with AIS were not significantly superior than those of other studies, this study showed a high rate of successful endovascular recanalization which was comparable to that of other studies. Therefore, ARTS using the SOFIA® catheter can be considered as the first choice of treatment for AIS due to large vessel occlusion.

Angiographic and Clinical Factors Related with Good Functional Outcome after Mechanical Thrombectomy in Acute Cerebral Artery Occlusion

  • Park, Jong Hyuk;Han, Young Min;Jang, Kyeong Sool;Yoon, Wan Soo;Jang, Dong Kyu;Park, Sang Kyu
    • Journal of Korean Neurosurgical Society
    • /
    • 제58권3호
    • /
    • pp.192-196
    • /
    • 2015
  • Objective : The aim of this study is to investigate good prognostic factors for an acute occlusion of a major cerebral artery using mechanical thrombectomy. Methods : Between January 2013 to December 2014, 37 consecutive patients with acute occlusion of a major cerebral artery treated by mechanical thrombectomy with stent retrievers were conducted. We analyzed clinical and angiographic factors retrospectively. The collateral flow and the result of recanalization were sorted by grading systems. Outcome was assessed by National Institutes of Health Stroke Scale (NIHSS) and modified Rankin Scale (mRS) at 90 days. We compared the various parameters between good and poor angiographic and clinical results. Results : Twenty seven patients demonstrated good recanalization [Thrombolysis in Cerebral Infarction (TICI) 2b or 3] after thrombectomy. At the 90-day follow up, 19 patients had good (mRS, 0-2), 14 had moderate (3-4) and four had poor outcomes (5-6). The mRS of older patients (${\geq}75years$) were poor than younger patients. Early recanalization, high Thrombolysis in Myocardial Infarction risk score, and low baseline NIHSS were closely related to 90-day mRS, whereas high TICI was related to both mRS and the decrease in the NIHSS. Conclusion : NIHSS decreased markedly only when recanalization was successful. A good mRS was related to low initial NIHSS, good collateral, and early successful recanalization.