• Title/Summary/Keyword: Steel fiber-reinforced mortar

Search Result 44, Processing Time 0.027 seconds

The Properties of Durability and Strength of Fiber-Reinforced Polymer-Modified Mortars Using Eco-Friendly UM Resin (친환경 UM수지를 사용한 섬유보강 폴리머 시멘트 모르타르의 내구성 및 강도 특성)

  • Kwon, Min-Ho;Seo, Hyun-Su;Lim, Jeong-Hee;Kim, Jin-Sup
    • Journal of the Korea Concrete Institute
    • /
    • v.25 no.3
    • /
    • pp.313-320
    • /
    • 2013
  • In this study, performance of fiber-reinforced polymer-modified mortar was studied for the development of eco-friendly materials for high performance repair and reinforcement. The general cement mortar and eco-friendly UM resin was mixed with a certain percentage for increased durability. To increase the strength of the polymer-modified mortar, PVA fiber, steel fiber and hybrid fiber were added at a constant rate. Hybrid fiber is contains the same percentage of PVA fiber and steel fiber. In order to determine the strength properties of fiber-reinforced polymer-modified mortar, the compressive strength test, the splitting tensile strength test and the flexural strength test were performed. And, in order to determine the durability properties of fiber-reinforced polymer-modified mortar, water absorption test and chemical resistance test were performed. From the experimental results, polymer-modified mortar using UM resin was improved durability. And the tensile strength and flexural strength increased, which were the vulnerability of fiber reinforced polymer-modified mortar. From this study, fiber-reinforced polymer-modified mortar using eco-friendly UM resin can be used to repair and reinforcement for the external exposure of concrete structures to improve the durability.

Evaluation of fracture reduction performance of fiber reinforced mortar according to fiber type (섬유종류에 따른 섬유보강 모르타르의 파괴저감성능 평가)

  • Roh, Jong-Chan;Kim, Gyu-Yong;Kim, Hong-Seop;Koo, Kyung-Mo;Yoon, Min-Ho;Yoo, Jae-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.11a
    • /
    • pp.38-39
    • /
    • 2013
  • In this study, in regard to fiber reinforced mortar mixing steel fiber and 4types of organic fiber, impact test was carried out. Because to predict fracture reduction performance with flexural, tensile strength when types of fiber were different as impact reduction performance of concrete is closely related with toughness such as flexural strength, tensile strength and fracture energy etc. As a result, enhancement of toughness by fiber reinforcement controls the spall of rear. On the other hand in case of steel fiber relatively turned up high toughness in appropriate load compared with organic fiber but in same mixing rate, impact reduction performance by projectile showed low performance due to few number of an individual of mixing.

  • PDF

Analysis of the Flowability for Organic·Inorganic Fiber with the Variation of Length (유·무기 섬유 길이조합변화에 따른 섬유 보강 모르타르의 유동성 분석)

  • Park, Yong-Jun;Kang, Byung-Hoi;Lee, Hong-Kyu;Jo, Man-Ki;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2014.05a
    • /
    • pp.128-129
    • /
    • 2014
  • In this study, flowability of the mortar added with length change and combination of steel and inorganic fiber has been tested to evaluate the performance of fiber-reinforced mortar. The following results could be made as the conclusion. Early age flow of the mortar has been decreased when fibers added. Slump also decreased with the adding of fibers. For the air content, comparing with Plain, all the specimens with fibers showed higher air content than Plain., Addition of every kinds fibers showed the similar EIS test results.

  • PDF

Material Model for Tensile Behavior of Lathe Scrap Reinforced Mortar (선반 스크랩 보강 모르타르의 인장거동에 대한 재료모델)

  • Hyun-Jin, Lee;Su-Ho, Bae;Soon-Oh, Kwon
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.4
    • /
    • pp.443-449
    • /
    • 2022
  • When fiber reinforced concrete is manufactured, it is useful to utilize lathe scrap as an aiternative material of steel fiber, because it is not only economical as an by-product of steel manufactures, but also has a very similar composition to that of steel fiber. The purpose of this experimental research is to evaluate the compressive strength and tensile behavior and then propose a material model of lathe scrap reinforced mortar. For this purpose, the lathe scrap reinforced mortars were ma de a ccording to their tota l volume fra ction of 1.5 % for wa ter-binder ra tio of 30 % a nd 40 %, respectively, a nd then the mechanical properties such as compressive strength, direct tensile strength, and stress-strain curve of those were evaluated. Also, based on the experimental results of lathe scrap reinforced mortar the material model for tensile behavior was suggested. It was revealed that the experimental results and the proposed material model corresponded relatively well.

An Experimental Study on the Performance of Bond-Type Anchorage Systems with Various Dimensions of Steel Mold (CFRP 긴장재용 부착형 정착 장치의 강관 몰드 제원에 따른 정착 성능 실험 연구)

  • Jung, Woo-Tai;Park, Young-Hwan;Park, Jong-Sup
    • Journal of the Korea Concrete Institute
    • /
    • v.23 no.3
    • /
    • pp.257-264
    • /
    • 2011
  • This paper contains the experimental performance evaluation results of bond-type anchorage systems with the CFRP(carbon fiber reinforced polymer) tendon. The preliminary tests were performed to find the appropriate filling materials in the steel molds. A total of five materials including epoxy or cement mortar have been used as fillers in the steel molds. Results of the preliminary tests showed that specimen filled with non-shrinkage mortar showed maximum tensile strength. Based on the finding, the non-shrinkage mortar was selected as filler for anchoring CFRP tendons. Additional tests were performed as a parametric study to select proper size of steel molds such as external diameter, thickness, and length. The proper size of steel molds with non-shrinkage mortar was selected based on the test results, which gave stable tensile performance.

Study on Microstructure and Electrical Properties of Cement Mortar Containing Conductive Fibers (전도성 섬유가 함유된 시멘트 모르타르의 미세구조 및 전기적 특성 연구)

  • Park, Jong-Gun;Seo, Dong-Ju;Lim, Doo-Yeol;Lee, Yu-Jae;Heo, Gwang-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.3
    • /
    • pp.72-83
    • /
    • 2022
  • This paper studied the effect on the microstructure, electrical properties, and compressive strength of cement mortar containing carbon fiber (CF) and steel fiber (SF), which are conductive materials. The resistivity of conductive fiber-reinforced cement mortar (FRCM) was measured using the 4-probe method, and the compressive strength was measured based on the compression test. Their performance was compared and reviewed with plain mortar (PM). Furthermore, the surface shape and composition of the fracture surface of the conductive FRCM were analyzed using a scanning electron microscope (SEM) and an energy disperse X-ray spectrometer (EDS). The results showed that the resistivity gradually increased as the curing time increased in all specimens, whereas the resistivity decreased significantly as the fiber volume fraction increased. Adding steel fibers up to 1.25% did not affect the resistivity of cement mortar considerably. On the contrast, the resistivity of carbon fiber was somewhat decreased even at low contents (ie, 0.1 to 0.3%), and thereafter, it was significantly decreased. The percolation threshold of the conductive CFRCM containing CF used in this experiment was 0.4%, and it is judged to be the optimum carbon fiber dosage to maximize the conductive effect while maintaining the compressive strength performance as much as possible. For the surface shape and composition analysis of conductive FRCM, the fracture surface was observed through SEM-EDS. These results are considered to be very useful in establishing the microstructure mechanism of reinforcing fibers in cement mortars.

The influence of magnetic field on the alignment of steel fiber in fresh cementitious composites

  • Li, Hui;Li, Lu;Li, Lin;Zhou, Jian;Mu, Ru;Xu, Mingfeng
    • Computers and Concrete
    • /
    • v.30 no.5
    • /
    • pp.323-337
    • /
    • 2022
  • This paper proposes a numerical model to simulate the rotational behavior of steel fiber in fresh cement-based materials in the presence of a magnetic field. The results indicate that as the aspect ratio of fiber increases, the required minimum magnetic field intensity to make fiber rotate in viscous fluid increases. The optimal magnetic field intensity is 0.03 T for aligning steel fiber in fresh cement-based materials to ensure that the applying time of the magnetic field can be conducted concurrently with the vibrating process to increase the aligning efficiency. The orientation factor of steel fiber in cement mortar can exceed 0.85 after aligning by 0.03 T of the uniform magnetic field. When the initial angle of the fiber to the magnetic field direction is less than 10°, the magnetic field less than 0.03 T cannot make the fiber overcome the yield stress of fluid to rotate. The coarse aggregate in steel fiber-reinforced concrete is detrimental to the rotation and alignment of the steel fiber. But the orientation factor of ASFRC under the 0.03T of the magnetic field can also exceed 0.8, while the orientation factor of SFRC without magnetic field application is around 0.6.

Impact resistant properties of Kagome truss reinforced composite panels

  • Choi, Jeong-Il;Park, Se-Eon;Lee, Sang-Kyu;Kim, Gyu-Yong;Hwang, Jae-Seung;Lee, Bang Yeon
    • Advances in concrete construction
    • /
    • v.12 no.5
    • /
    • pp.391-398
    • /
    • 2021
  • This paper presents an experimental study exploring impact resistant properties of Kagome truss reinforced composite panels. Three types of panels with different materials and reinforcements, i.e., ultra-high-performance mortar, steel fiber, and Kagome truss, were designed and manufactured. High-velocity projectile impact tests were performed to investigate the impact response of panels with dimensions of 200 mm×200 mm×40 mm. The projectile used in the testing was a steel slug with a hemispherical front; the impact energy was 1 557 J. Test results showed that the Kagome truss reinforcement was effective at improving the impact resistance of panels in terms of failure patterns, damaged area, and mass loss. Synergy effects of a combination of Kagome truss and fiber reinforcements for the improvement of impact resistance capacity of ultra-high-performance mortar were also observed.

Bending Property of Composited Ductile Fiber Reinforced Cementitious Composite, DFRCC (고인성 섬유보강 시멘트 복합재료의 복합구성에 의한 휨 특성)

  • 김규용;손유신;양일승;후쿠야마히로시;윤현도;김무한
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.367-372
    • /
    • 2003
  • Fiber Reinforced Cementitious Composite, DFRCC has strain hardening property with multiple crack in failed of compressive, tensile, bending force, concrete is not so that. But DFRCC could not use to the building element for which has not structural stiffness only has ductile property. DFRCC is used for repair only in recently. In that reason, we considered the concrete of light weight concrete, porous concrete, mortar complex with DFRCC. and DFRCC reinforced by fiber net, steel bar. In this study, results of experiment on complex method of concrete and DFRC were shown as follows; The complex methods of concrete lay on DFRCC, sandwich layer composition were effective for bending force depending on section size each layer, and reinforce DFRCC by fiber net, steel bar was effective method also.

  • PDF

Evaluation of Impact Resistance of Steel Fiber and Organic Fiber Reinforced Concrete and Mortar

  • Kim, Gyu-Yong;Hwang, Heon-Kyu;Nam, Jeong-Soo;Kim, Hong-Seop;Park, Jong-Ho;Kim, Jeong-Jin
    • Journal of the Korea Institute of Building Construction
    • /
    • v.12 no.4
    • /
    • pp.377-385
    • /
    • 2012
  • In this study, the Impact resistance of steel fiber and organic fiber reinforced concrete and mortar was evaluated and the improvement in toughness resulting from an increase in compressive strength and mixing fiber for impact resistance on performance was examined. The types of fiber were steel fiber, PP and PVA, and these were mixed in at 0.1, 0.5 and 1.0 vol.%, respectively. Impact resistance is evaluated with an apparatus for testing impact resistance performance by high-speed projectile crash by gas-pressure. For the experimental conditions, Specimen size was $100{\times}100{\times}20$, 30mm ($width{\times}height{\times}thickness$). Projectile diameter was 7 and 10 mm and impact speed is 350m/s. After impact test, destruction grade, penetration depth, spalling thickness and crater area were evaluated. Through this evaluation, it was found that as compressive strength is increased, penetration is suppressed. In addition, as the mixing ratio of fiber is increased, the spalling thickness and crater area are suppressed. Organic fibers have lower density than the steel fiber, and population number per unit area is bigger. As a result, the improvement of impact resistance is more significant thanks to dispersion and degraded attachment performance.