• 제목/요약/키워드: Steel fiber-reinforced mortar

검색결과 44건 처리시간 0.023초

전기역학적 임피던스 기법을 이용한 강섬유 보강 모르타르의 응결시간 평가 (Measurement of Setting Times of Steel Fiber Reinforced Mortar using Electric-mechanical Impedance Sensing Technique)

  • 이준철;김화중
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.183-184
    • /
    • 2016
  • This study investigated the evolution of electro-mechanical impedance (EMI) of piezoelectricity (PZT) sensor embedded in hydrating steel fiber reinforced mortar to determine the setting times of that. Penetration resistance test was also conducted in order to justify the valid of EMI sensing technique. As a result, the setting times of steel fiber reinforced mortar can be effectively monitored through the EMI sensing technique using PZT sensor.

  • PDF

섬유를 혼입한 프리플레이스 모르타르의 내충격 성능 평가 (Evaluation of Impact Resistance Performance of Fiber Reinforced Preplace Grout Mortar)

  • 이상규;김규용;최경철;김홍섭;이영욱;황의철
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2015년도 춘계 학술논문 발표대회
    • /
    • pp.65-66
    • /
    • 2015
  • In this study, it evaluate mecahnical performance and impact resistance performance of fiber reinforced concrete, fiber reinforced mortar and preplace grout mortar. steel fiber, nylon fiber and polypropylene fiber are reinforced 1vol.% 2vol.% 10vol.% by each fiber type. It evaluate impact resistance performance to use projectile 10mm of 400m/s velocity. As a result, mechnical performance and impact resistance performance of fiber reinforced preplace grout mortar are improved a lot by 10% fiber reinforced ratio.

  • PDF

AE를 이용한 탄소섬유시트 강화 모르타르의 파괴거동에 관한 연구 (A Study on the Failure Behavior of Carbon Fiber Sheet Reinforced Mortar Using Acoustic Emission Technique)

  • 이진경;이준현;장일영
    • 콘크리트학회논문집
    • /
    • 제12권3호
    • /
    • pp.67-75
    • /
    • 2000
  • It was well recognized that the damages associated mainly with the aging of civil infrastructures were one of very serious problems for assurance of safety and reliability. Recently carbon fiber sheet(CFS) has been widely used for reinforcement and rehabilitation of damaged concrete beam. However, the fundamental mechanism of load transfer and its load-resistant for carbon fiber sheet reinforced concrete are not fully understood. In this study, three point bending test has been carried out to understand the damage progress and the micro-failure mechanism of CFS reinforced mortars. For this purpose, four different types of specimens are used, that is, mortar, steel bar reinforced mortar, CFS reinforced mortar, and steel bar and CFS reinforced morter. Acoustic Emission(AE) technique was used to evaluate the characteristics of damage progress and the failure mechanism of specimens. in addition, two-dimensional AE source location was also performed to monitor crack initiation and propagation processes for these specimens.

고유동 강섬유보강 모르타르의 유동에 따른 섬유의 방향성 분포특성 변화의 예측 (Numerical Simulation for the Variation of the Fiber Orientation Distribution according to the Flow of High-Flow Steel-Fiber Reinforced Mortar)

  • 강수태;김진근
    • 한국전산구조공학회논문집
    • /
    • 제22권6호
    • /
    • pp.639-646
    • /
    • 2009
  • 고유동 강섬유보강 모르타르는 타설과정에서 특정한 섬유 방향성 분포를 가질 수 있으며, 이에 따라 재료의 인장거동 특성에 영향을 미칠 수 있다. 본 연구에서는 고유동 강섬유보강 모르타르의 타설단계에서의 유동에 따른 강섬유의 섬유 방향성 분포의 변화를 해석적으로 구하였다. 해석결과에 따르면 180mm 간격으로 나란히 놓여진 두 평판 사이에 흐르는 모르 타르의 전단흐름에 의한 섬유의 방향성 변화는 초기 150mm이내에서 크게 발생하는 것을 확인할 수 있었으며, 이후에서는 방향성 분포의 경향은 크게 변하지 않으며, 다만 흐름방향에 나란한 섬유의 밀도가 집중적으로 커지는 것을 볼 수 있었다. 섬유의 방향성과 섬유보강 복합체의 인장거동과 밀접한 관련성을 고려할 때, 이와 같은 방향성의 예측을 바탕으로 유동에 따른 고유동 강섬유보강 모르타르의 인장거동 변화의 예측이 가능할 것이다.

소성힌지부 강섬유 혼입 모르타르 적용 철근콘크리트 기둥의 내진성능평가 (Seismic Performance Evaluation of Reinforced Concrete Columns by Applying Steel Fiber-Reinforced Mortar at Plastic Hinge Region)

  • 조창근;한성진;권민호;임청권
    • 콘크리트학회논문집
    • /
    • 제24권3호
    • /
    • pp.241-248
    • /
    • 2012
  • 이 연구에서는, 철근콘크리트 기둥 실험체를 대상으로 기둥의 휨 위험 단면부에 국부적으로 강섬유 시멘트모르타르를 적용함으로서 기존 철근콘크리트 기둥에 비해 내진성능이 우수한 강섬유 모르타르 적용 철근콘크리트 복합기둥공법에 관해 제시하였다. 제시된 적용공법의 성능검증을 위하여 기존 철근콘크리트 기둥 1개 및 소성힌지구간에 국부적으로 강섬유 모르타르를 적용한 복합기둥 실험체 2개를 제작하여 일정 축하중 하에서 횡방향 반복하중을 받는 재하시험을 수행하였다. 콘크리트 및 강섬유 모르타르는 모두 현장타설되었다. 재하시험 결과 기존 철근콘크리트 기둥 실험체와 비교하여 강섬유 모르타르 적용 철근콘크리트 복합기둥 실험체의 경우 휨 및 전단 균열의 제어에 우수할 뿐만 아니라 기둥의 횡하중 내력 및 횡방향 변형 능력 향상에서도 우수한 것으로 평가되었다.

Flexural Behavior of Polymer Mortar Permanent Forms Using Methyl Methacrylate Solution of Waste Expanded Polystyrene

  • Bhutta, M. Aamer Rafique;Tsuruta, Ken;Ohama, Yoshihiko
    • International Journal of Concrete Structures and Materials
    • /
    • 제2권1호
    • /
    • pp.35-39
    • /
    • 2008
  • This experimental study examines the applicability of polymer mortar permanent forms using a methyl methacrylate (MMA) solution of waste expanded polystyrene (EPS) to develop effective recycling processes for the EPS, referring to the flexural behavior of a polymer-impregnated mortar permanent form with almost the same performance as commercial products. An MMA solution of EPS is prepared by dissolving EPS in MMA, and unreinforced and steel fiber-reinforced polymer mortars are mixed using the EPS-MMA-based solution as a liquid resin or binder. Polymer mortar permanent forms (PMPFs) using the EPS-MMA-based polymer mortars without and with steel fiber and crimped wire cloth reinforcements and steel fiber-reinforced polymer-impregnated mortar permanent form (PIMPF) are prepared on trial, and tested for flexural behavior under four-point (third-point) loading. The EPS-MMAbased PMPFs are more ductile than the PIMPF, and have a high load-bearing capacity. Consequently, they can replace PIMPF in practical applications.

강 및 탄소 섬유를 사용한 하이브리드 섬유보강 모르타르의 압축·휨성능 향상 (Improved Compressive·Flexural Performance of Hybrid Fiber-Reinforced Mortar Using Steel and Carbon Fibers)

  • 허광희;박종건;서동주;고성곤
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권5호
    • /
    • pp.48-59
    • /
    • 2021
  • 본 연구에서는 다른 재료특성을 갖는 강섬유 또는 탄소섬유만을 사용한 단일 섬유보강 모르타르(fiber-reinforced mortar, FRM)와 강 및 탄소 섬유를 혼합사용한 하이브리드 FRM의 압축·휨성능을 조사하기 위해 실험을 수행하였다. 모르타르 시편은 총 섬유혼입률 1.0%에서 부피에 의한 1+0%, 0.75+0.25%, 0.5+0.5%, 0.25+0.75% 및 0+1%의 혼합비율로 강섬유와 탄소섬유를 혼입하였다. 이들의 역학적 성능을 재령 28일에서 섬유가 없는 플레인 모르타르와 비교, 검토하였다. 모르타르의 실험결과는 강섬유 0.75% + 탄소섬유 0.25%를 혼합사용한 하이브리드 FRM가 가장 높은 압축강도와 휨강도를 나타내, 하이브리드 FRM의 시너지 보강효과를 확인할 수 있었다. 반면, 강섬유 0.5% + 탄소섬유 0.5%를 혼합사용한 하이브리드 FRM의 경우 가장 높은 휨인성을 얻었으며, 본 실험결과를 토대로 강도와 휨인성을 동시에 개선하기 위한 하이브리드 FRM의 최적의 섬유 혼합비율을 제시하였다. 게다가, FRM 시편의 이미지 분석을 위해 주사전자현미경(scanning electron microscope, SEM)을 통해 파단면을 관찰하였다. 이들 결과는 시멘트 매트릭스 내에서 하이브리드 보강섬유의 이미지 분석을 하는 데 큰 도움이 되었다.

강섬유보강 초고강도 시멘트 모르터의 수축저감에 관한 연구 (A Study on the Shrinkage Reducing Properties of Steel Fiber Reinforced Ultra High Strength Cement Mortar)

  • 한동엽;허영선;배장춘;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 추계 학술논문 발표대회
    • /
    • pp.67-70
    • /
    • 2005
  • Ultra high strength concrete, nowadays, has been widely applied to construction of high-rise building. To improve ductility and mechanical properties, steel fiber is employed in UHSC. This study investigates practical application of expansive additives(EA) and shrinkage reducing agent(SRA), in order to secure volumetric stability and improved mechanical properties, such as autogenous shrinkage and dry shrinkage of steel-fiber-reinforced-ultra-high-strength-comet-mortar(FHSM). According to the test, individual addition of steel fiber does not affect shrinkage reduction, as expected. However FHSM, with combined addition of 5$\%$ of EA and 1$\%$ of SRA decreased 60$\%$ of autogenous shrinkage. It is considered that Proper combination of EA and SRA can secure the shrinkage resistance of FHSM.

  • PDF

강섬유보강 모르타르 바름에 의한 콘크리트 조적 프리즘의 압축 및 사인장 강도 증진 효과 (Enhancement of Compressive and Shear Strength for Concrete Masonry Prisms with Steel Fiber-Reinforced Mortar Overlay)

  • 유지훈;명성진;박지훈
    • 한국지진공학회논문집
    • /
    • 제25권1호
    • /
    • pp.21-32
    • /
    • 2021
  • Concrete masonry prisms are strengthened with steel fiber-reinforced mortar (SFRM) overlay and tested for compressive and diagonal tension strength. Masonry prisms are produced in poor condition considering standard workmanship for masonry buildings in Korea. Amorphous steel fibers are adopted for SFRM, and appropriate mixing ratios of SFRM are derived considering constructability and strength. Masonry prisms are strengthened with different fiber volume ratios, while numerous strengthened faces and additional reinforcing meshes are produced for compression and diagonal tension tests. Compression and diagonal tension strength are increased by up to 122% and 856%, respectively, and the enhancement effect for diagonal tension strength was superior compared to compression strength. Finally, the test results and strength prediction equations based on existing literature and regression analysis are compared.

시멘트 모르타르 내 비정질 강섬유와 일반 강섬유의 부착특성 비교 (Comparative Bond Characteristics of Amorphous Steel Fiber and Conventional Steel Fiber in Cement Mortar)

  • 최성규;김영준;김백중;이종구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2014년도 춘계 학술논문 발표대회
    • /
    • pp.238-239
    • /
    • 2014
  • It is well known that the bond characteristics of fiber govern the performance of fiber reinforced composite material. A preliminary study was carried out to investigate the pull-out behavior of amorphous and conventional single fiber in cement mortar in accordance with the JCI(Japan Concrete Institute) SF-8. The test was performed under displacement control, and results showed that the bond strength decreased with increasing fiber length. In addition, the amorphous steel fiber showed much higher pull-out load per unit weight compared to conventional steel fiber.

  • PDF