• 제목/요약/키워드: Steam leakage

검색결과 87건 처리시간 0.028초

카메라 흔들림 보정을 통한 증기 누설 탐지 (Detecting steam leakage by using correction of camera vibrating)

  • 최영철;윤찬훈;김진섭
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2014년도 추계학술대회 논문집
    • /
    • pp.394-398
    • /
    • 2014
  • Steam leakage is one of the major issues for the structural fracture of pipes of nuclear power plants. Therefore a method to inspect a large area of piping systems quickly and accurately is needed. Recently, the research detecting the steam leakage by using camera image is introduced. However, this method has a disadvantage. If a camera oscillates, it cannot detect a steam leakage exactly. In this paper, the technique that reduces the error due to a camera shaking is proposed. To verify the proposed method, we have performed the experiments for the oil leakage experiments. The results show that the technique can calibrate the error due to camera shaking.

  • PDF

영상을 이용한 누설탐지에서 카메라 진동 오차 보정 (Correction of Error due to Camera Vibrating During Detecting Steam Leakage by Using Image)

  • 최영철;전형섭;손기성;박종원
    • 한국소음진동공학회논문집
    • /
    • 제24권10호
    • /
    • pp.795-801
    • /
    • 2014
  • Steam leakage is one of the major issues for the structural fracture of pipes of nuclear power plants. Therefore a method to inspect a large area of piping systems quickly and accurately is needed. Recently, the research detecting the steam leakage by using camera image is introduced. However, this method has a disadvantage. If a camera oscillates, it cannot detect a steam leakage exactly. In this paper, the technique that reduces the error due to a camera shaking is proposed. To verify the proposed method, we have performed the experiments for the oil leakage experiments. The results show that the technique can calibrate the error due to camera shaking.

스팀터빈용 래비린스 실의 누설량 규명을 위한 공기상사 실험 및 해석 (Air Similarity Test and Analysis of Steam Turbine Labyrinth Seal for Leakage Verification)

  • 안상규;김승종;이용복;김창호;하태웅
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 춘계학술대회논문집
    • /
    • pp.1149-1149
    • /
    • 2006
  • The leakage characteristic is an important factor in power plant. However, most of power plant have efficiency problem which is occurred leaking between high pressure steam turbine axle and stator. The labyrinth seal which is used between the main turbine axle and stator in the power plant. Because it is able to be non-contact seal and it is minimize clearance to decrease the leakage. But its actual system is too huge to experiment. Therefore, most steam turbine seal performance tests were conducted by air similarity test. This paper described a test facility and program for air similarity test of high pressure steam turbine seal. A test facility has been designed and built to evaluate leakage verification of labyrinth seal. The test facility consist of air compressor, anti-swirl labyrinth seal for 1/3 air similarity model, pressure transducer, air flow measure system, instrumentation and auxiliary system. For evaluation of steam turbine seal performance, the air similarity test of labyrinth seal leakage verification was conducted and we compared experiment data and analysis result.

  • PDF

다중계측기법을 이용한 원전 주증기배수밸브의 현상태 누설진단에 관한 연구 (A Study on the As-Built Leakage Diagnosis of Main Steam Drain Valves for Nuclear Power Plants by Multi-measuring Technique)

  • 김성영;김영범;김도형;이상국
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2606-2611
    • /
    • 2008
  • The high energy fluid leakage from the high temperature and high differential pressure drop system of NPPs (Nuclear Power Plants) decreases efficiency and consequently leads to considerable economic loss due to less power production. Also, the leakage possibly damages critical parts of components such as valve and trim with the effect of cavitation, flashing, and erosion, etc. and deteriorates its performance. Thus, in this study, we diagnosed the as-is leakage for four (4) main steam drain valves and two (2) steam traps of Yonggwang 1,2 units during normal operation by using multi-measuring technique and observed the occurrence of fine leakage. In the course of measuring fluid leakage, the sign of fine leakage is estimated to be the leakage from orifice. By converting the leakage to energy loss, it is equivalent to the amount of several hundred thousand won per each unit, which supports the basis for the justification of fine leakage.

  • PDF

CFD를 사용한 스팀터빈용 각이 진 패킹 링 실의 누설량 예측 (Leakage Analysis of Angled-Labyrinth-Packing-Ring Seal for Steam Turbine Using CFD)

  • 하태웅;강정현
    • Tribology and Lubricants
    • /
    • 제25권5호
    • /
    • pp.298-304
    • /
    • 2009
  • An angled labyrinth seal is used for the diaphragm-packing-ring seal design of steam turbine due to its leakage reduction characteristic. CFD analysis using FLUENT has been performed to predict leakage and determine an optimum slanted angle which yields the best leakage reduction. Results show that the optimum value of slanted angle is $-30^{\circ}$ independent of number of labyrinth teeth, inlet pressure, and tooth height to pitch ratio. 3D CFD analysis has been performed for predicting leakage of the angled labyrinth seal. Comparing with the result of 2D CFD analysis, 3D CFD analysis shows 1.4% smaller.

증기터빈 래비린스 실의 형상 개선을 통한 누설량 저감에 관한 연구 (Reduction of Leakage through Labyrinth Seal in a Steam Turbine by Modification of the Teeth Shape)

  • 안중현;허진혁;문승재;이재헌;유호선
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2009년도 하계학술발표대회 논문집
    • /
    • pp.857-862
    • /
    • 2009
  • In this study, the numerical study has carried out to analyze the leakage in a steam turbine labyrinth seal. We modified tooth shape of the labyrinth seal and finds out difference of leakage in this study. Original model is straight labyrinth seal and its modified model is slant labyrinth seal. The numerical analyses are implemented on two models. The numerical results show that each leakage of tooth shape are found 0.4781 kg/s and 0.4485 kg/s, respectively. Slant labyrinth seal seals in a steam better than straight labyrinth seal. Since, actual clearance of the stream function in the slant model is smaller than the straight model.

  • PDF

영상신호를 이용한 증기누설 검출 방법 (Steam Leak Detection by Using Image Signal)

  • 최영철;손기성;전형섭;박진호
    • 한국소음진동공학회논문집
    • /
    • 제20권9호
    • /
    • pp.828-833
    • /
    • 2010
  • Steam leakage is one of the major issues for the structural fracture of pipes of nuclear power plants. Therefore a method to inspect a large area of piping systems quickly and accurately is needed. In this paper, we proposed the method for the detecting steam leakage by using image signal processing. Our basic idea come from heat shimmer which shine with a soft light that looks as if it shakes slightly. To test the performance of this technique, experiments have been performed for simple heat source and steam generator. Results show that the proposed technique is quite powerful in the steam leak detection.

스팀 터빈용 조합형 엇갈린 래버린스 실의 누설량 및 동특성 해석 (The Leakage and Rotordynamic Analysis of A Combination-Type-Staggered-Labyrinth Seal for A Steam Turbine)

  • 하태웅;이용복;김승종;김창호
    • 한국유체기계학회 논문집
    • /
    • 제7권6호
    • /
    • pp.45-54
    • /
    • 2004
  • Governing equations and numerical solution methods are derived for the analysis of a combination-type-staggered-labyrinth seal used in high performance steam turbines. A bulk flow is assumed for each combination-type-staggered-labyrinth cavity. Axial flow through a throttling labyrinth strip is determined by Neumann's leakage equation and circumferential flow is assumed to be completely turbulent in the labyrinth cavity. Moody's wall-friction-factor formula is used for the calculation of wall shear stresses. For the reaction force developed by the seal, linearized zeroth-order and first-order perturbation equations are developed for small motion near the centered position. Integration of the resultant first-order pressure distribution along and around the seal defines the rotordynamic coefficients of the combination-type-staggered-labyrinth seal. Theoretical results of leakage and rotordynamic characteristics for the IP4-stage seal of USC (ultra super critical) steam turbine are shown with the effect of sump pressure, the number of throttling labyrinth strip, and rotor speed.

Magnetic Flux Leakage (MFL) based Defect Characterization of Steam Generator Tubes using Artificial Neural Networks

  • Daniel, Jackson;Abudhahir, A.;Paulin, J. Janet
    • Journal of Magnetics
    • /
    • 제22권1호
    • /
    • pp.34-42
    • /
    • 2017
  • Material defects in the Steam Generator Tubes (SGT) of sodium cooled fast breeder reactor (PFBR) can lead to leakage of water into sodium. The water and sodium reaction will lead to major accidents. Therefore, the examination of steam generator tubes for the early detection of defects is an important requirement for safety and economic considerations. In this work, the Magnetic Flux Leakage (MFL) based Non Destructive Testing (NDT) technique is used to perform the defect detection process. The rectangular notch defects on the outer surface of steam generator tubes are modeled using COMSOL multiphysics 4.3a software. The obtained MFL images are de-noised to improve the integrity of flaw related information. Grey Level Co-occurrence Matrix (GLCM) features are extracted from MFL images and taken as input parameter to train the neural network. A comparative study on characterization have been carried out using feed-forward back propagation (FFBP) and cascade-forward back propagation (CFBP) algorithms. The results of both algorithms are evaluated with Mean Square Error (MSE) as a prediction performance measure. The average percentage error for length, depth and width are also computed. The result shows that the feed-forward back propagation network model performs better in characterizing the defects.

영광 #1/2 복수기 누수부 보수공사 (Yeonggwang #1/2 steam condenser leakage repair works)

  • 이상철;공창식
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2003년도 춘계학술발표대회 개요집
    • /
    • pp.117-119
    • /
    • 2003
  • Power plant efficiency and availability depend greatly on condenser performance. However, during commissioning of Yeonggwang #1/2 steam condenser sodium leakage occurred, because of tube to tubesheet only roll expanding. Therefore this report is explaining that pre-test for the shake of improvement reliable repair processes & selected sampling tube re-expansion in-situ applications.

  • PDF