• Title/Summary/Keyword: Steady-State Value

Search Result 458, Processing Time 0.028 seconds

Heat Transfer Characteristics of an Annulus Channel Cooled with R-134a Fluid near the Critical Pressure (임계압력 근처에서의 환형관 채널에 대한 열전달 특성 연구)

  • Hong, Sung-Deok;Chun, Se-Young;Kim, Se-Yun;Baek, Won-Pil
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.2094-2099
    • /
    • 2004
  • An experimental study on heat transfer characteristics near the critical pressure has been performed with an internally-heated vertical annular channel cooled by R-134a fluid. Two series of tests have been completed: (a) steady-state critical heat flux (CHF) and (b) heat transfer tests for pressure reduction transients through the critical pressure. In the present experimental range, the steady-state CHF decreases with the increase of the system pressure For a fixed inlet mass flux and subcooling, the CHF falls sharply at about 3.8 MPa and shows a trend toward converging to zero as the pressure approaches the critical point of 4.059 MPa. The CHF phenomenon near the critical pressure does not lead to an abrupt temperature rise of the heated wall because the CHF occurred at remarkably low power levels. In the pressure reduction transient experiments, as soon as the pressure passed through the critical pressure, the wall temperatures rise rapidly up to a very high value due to the occurrence of the departure from nucleate boiling. The wall temperature reaches a maximum at the saturation point of the outlet temperature, then tends to decrease gradually.

  • PDF

Optimized Coupling Factor for Minimizing Ripple Current of Coupled Inductor under Variable Duty in Rapid Traction Battery Charger

  • Kang, Taewon;Chae, Beomseok;Kang, Tahyun;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2014.07a
    • /
    • pp.335-336
    • /
    • 2014
  • This paper investigates the design of coupled inductor for minimum inductor current ripple in rapid traction battery charger systems. Based on the general circuit model of coupled inductor together with the operating principles of dc-dc converter, the relationship between the ripple size of inductor current and the coupling factor is derived under the different duty ratio. The optimal coupling factor which corresponds to a minimum inductor ripple current becomes -1, i.e. a complete inverse coupling without leakage inductance, as the steady-state duty ratio operating point approaches 0.5. In an opposite manner, the optimal coupling factor value of zero, i.e. zero mutual inductance, is required when the steady-state duty ratio operating point approaches either zero or one. Coupled inductors having optimal coupling factor can minimize the ripple current of inductor and battery current resulting in a reliable and efficient operation of battery chargers.

  • PDF

Study on bidirectional fluid-solid coupling characteristics of reactor coolant pump under steady-state condition

  • Wang, Xiuli;Lu, Yonggang;Zhu, Rongsheng;Fu, Qiang;Yu, Haoqian;Chen, Yiming
    • Nuclear Engineering and Technology
    • /
    • v.51 no.7
    • /
    • pp.1842-1852
    • /
    • 2019
  • The AP1000 reactor coolant pump is a vertical shielded-mixed flow pump, is the most important coolant power supply and energy exchange equipment in nuclear reactor primary circuit system, whose steadystate and transient performance affect the safety of the whole nuclear island. Moreover, safety demonstration of reactor coolant pump is the most important step to judge whether it can be practiced, among which software simulation is the first step of theoretical verification. This paper mainly introduces the fluid-solid coupling simulation method applied to reactor coolant pump, studying the feasibility of simulation results based on workbench fluid-solid coupling technology. The study found that: for the unsteady calculations of the pure liquid media, the average head of the reactor coolant pump with bidirectional fluid-solid coupling decreases to a certain extent. And the coupling result is closer to the real experimental value. The large stress and deformation of rotor under different flow conditions are mainly distributed on impeller and idler, and the stress concentration mainly occurs at the junction of front cover plate and blade outlet. Among the factors that affect the dynamic stress change of rotor, the pressure load takes a dominant position.

OSCILLATORY THERMAL CONVECTION IN A HORIZONTAL ANNULUS (수평 환형 공간에서의 진동하는 열대류)

  • Yoo Joo-Sik
    • Journal of computational fluids engineering
    • /
    • v.11 no.2 s.33
    • /
    • pp.49-55
    • /
    • 2006
  • This study investigates the oscillatory thermal convection of a fluid with Pr=0.02 in a wide-gap horizontal annulus with constant heat flux inner wall. When Pr=0.02, dual steady-state flows are not found. After the first Hopf bifurcation from a steady to a time-periodic flow, five successive period-doubling bifurcations are recorded before chaos. The power spectrum shows the $period-2^4\;and\;2^5$ flows clearly, and a window of period $3{\times}2^3$ flow is found in the chaotic regime. The approximate value of the Feigenbaum number for the last three period-doubling bifurcations is 4.76. The transition route to chaos of the present simulations is consistent with the period-doubling route of Feigenbaum.

The Characteristics of Electrokinetic Remediation for Unsaturated Soil (불포화토의 동전기정화 특성에 관한 실험적 연구)

  • 김병일;김익현;한상재;김수삼
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2003.03a
    • /
    • pp.641-646
    • /
    • 2003
  • In this study, a series of electrokinetic(EK) remediation experiments are carried out under the different degree of saturation for contaminated soil with lead. for constant electrical potential, the final current of all the sample represents the similarity to steady-state value of 5∼7mA. Under conditions of all the degree of saturation the anode reservoir becomes acidic(pH as low as 3) while the cathode reservoir is basic(pH as high as 12). But pH changes in the sample is a little and decontamination efficiency is the low.

  • PDF

An algorithm of detecting changed intervals with step-type shape in motor's speed response data (모터 스텝 응답에서 변동 구간 검출 기법)

  • Kim, Tae-Eun;Lee, Hai-Young
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.309-313
    • /
    • 2004
  • This paper presents an algorithm of detecting changed intervals with step-type shape in motor's speed response data. The proposed method is composed of 4 parts such as noise filtering, decision making of reference value's change, finding entrance point of steady state and detecting changed intervals. According to simulation results for three cases, we see that changed intervals can be found well.

  • PDF

감쇠진동계에 부착된 코일스프링과 오일댐퍼로 구성된 동흡진기

  • 최석창;안찬우;박일수;이희범
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1996.04a
    • /
    • pp.289-293
    • /
    • 1996
  • Vibration absorber is used to protect the primary system from steady-state harmonic disturbance. By attaching the absorber to the primary system which is modeled as a SDOF system, the new system becomes two DOF system. Depending on the driving frequency on the original system, the absorber needs to be carefully tuned, that is, to choose adequate value of the absorber mass and stiffness, so that the motion of the original mass is a minimum. This paper presents the effects of resonance frequency ratio and of vibration absorber with oil damper and coil spring for linear damped primary systems.

  • PDF

PREDATOR-PREY IN PATCHY SPACE WITH DIFFUSION

  • Alb, Shaban
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.15 no.2
    • /
    • pp.137-142
    • /
    • 2011
  • In this paper we formulate a predator-prey system in two patches in which the per capita migration rate of each species is influenced only by its own density, i.e. there is no response to the density of the other one. Numerical studies show that at a critical value of the bifurcation parameter the system undergoes a Turing bifurcation, i. e. the stable constant steady state loses its stability and spatially non-constant stationary solutions, a pattern emerge.

Derivative Feedback control of Robot Contact Force (Experimantal Investigation) (로보트 접촉력의 미분 피이드백제어 - (실험적 검토))

  • 김영탁;이종원;권영웅
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1990.10a
    • /
    • pp.140-144
    • /
    • 1990
  • On force control of robot, the transient response of the force is as important as the steady state value. We analyze the force for an 1 d.o.f. model. Based on the analysis, we finds out a desirable condition of the control system parameters for stability of the force. We propose a force rate feedback control for implementation. Through experiments we shows that the force can be controlled stably for an arbitrary environment.

  • PDF

A Variable Structure Point-to-Point Regulation Controller for Uncertain General Linear Systems (불확실 선형 시스템을 위한 적분 가변구조 지점에서 지점으로 레귤레이션 제어기)

  • Lee, Jung-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.4
    • /
    • pp.519-525
    • /
    • 2014
  • In this paper, an alternative variable structure controller is designed for the point-to-point regulation control of uncertain general linear plants so that the output of plants can be controlled from an arbitrarily given initial point to an arbitrarily given reference point in the state space. By using the error between the steady state value of the output and an arbitrarily given reference point and those integral, a transformed integral sliding surface is defined, in advance, as the surface from an initial state to an arbitrarily given reference point without the reaching phase problems. A corresponding control input is suggested to satisfy the existence condition of the sliding mode on the preselected transformed integral sliding surface against matched uncertainties and disturbances. Therefore, the output controlled by the proposed controller is completely robust and identical to that of the preselected transformed integral sliding surface. Through an example, the effectiveness of the suggested controller is verified.