• Title/Summary/Keyword: Steady state following

Search Result 142, Processing Time 0.031 seconds

A Study of Analgesic Effect of Twirling Acupuncture on Pain Model of the Formalin Test Using the Infrared Thermal Image Processing (적외선 영상 처리를 통한 Formalin Test 통증 모델에서의 염전 침자극 효과에 대한 연구)

  • Ryu, Jae-kwan;Lee, Soon-geul;Rhim, Sung-soo;Lee, Jae-dong;Min, Byung-il;Ryu, Un-young
    • Journal of Acupuncture Research
    • /
    • v.21 no.2
    • /
    • pp.223-233
    • /
    • 2004
  • Objective: As a manual accupucture method, the twirling-needle treatment has been known more effective in relieving pain than the conventional simple accupuncture treatment. Finding a proper treatment condition is difficult because of the lack of a quantative measurement of the alleviation of pain made by acupuncture. In this research, the authors propose the use of infrared thermal images in a formalin test to quantatively verify the effect of twirling. Methods: After injecting 10%~20% formalin into the tail of rats, the infrared thermal images(ITI) have been obtained to estimate the thermal distribution caused by inflammation. The authors propose a processing method to measure the thermal distribution from the thermal images obtained from the infrared camera as a pain model of the formalin test. Results: The pain model obtained from the infrared thermal image has two phases. The first phase, which is a transient period, is the initial 20 minutes when the pain is developed after the formalin injection. The second phase, which is a steady state, is where the development of pain lasts for 60 minutes or more after the first stage. This characteristic of the proposed model based on ITI is consistent with that of the pain model reported by other researchers whose works are based on the time-course of flinching and licking/biting, following a different concentration of formalin. It is noticed that the response of the thermal distribution obtained from ITI shows very high correlation to the behavioral response in the formalin test performed by Kazuhiro Okuda and four others5). In addition, the authors propose an ITI method to determine the pain-reducing effect of the acupuncture. The thermal distribution obtained from the experiment shows that there is significant pain reducing effect made by the twirling-needle method.

  • PDF

A Simulation of Temperature Control of Greenhouse with Hot-Water Heating System (온수난방시스템 온실의 온도제어 시뮬레이션)

  • 정태상;하종규;민영봉
    • Journal of Bio-Environment Control
    • /
    • v.8 no.3
    • /
    • pp.152-163
    • /
    • 1999
  • It is required to analyze the controlled response of air temperature in greenhouse according to control techniques for precise control. In this study, a mathematical model was established for air heating of greenhouse with hot-water heating system The parameters of the model were decided by regression analysis using reference data measured at the greenhouse being heated In the simulation for the digital control of air temperature in the greenhouse, the mathematical model to evaluate the control performances was used. Tested control methods were ON-OFF contpol, p control, rl control and PID control. The mathematical model represented by inside air temperature ( T$_{i}$), hot-water temperature (T$_{w}$) in heating pipe and outside air temperature (T$_{o}$) was expressed as a following discrete time equation ; T$_{i}$($textsc{k}$+1)= 0.851.T$_{i}$($textsc{k}$)+0.055.T$_{w}$($textsc{k}$)+0.094.T$_{o}$($textsc{k}$) Control simulations for various control methods showed the settling time, the overshoot and the steady state nor as follows; infinite time, 3.5$0^{\circ}C$, 3.5$0^{\circ}C$ for ON-OFF control : 30min 2.37$^{\circ}C$, 0.51$^{\circ}C$ for P control; 21min, 0.0$0^{\circ}C$, 0.23$^{\circ}C$ for PI control; 18min 0.0$0^{\circ}C$, 0.23$^{\circ}C$ for PID control, respectively. PI and PID controls appeared to be optimal control methods. There was no effect of differential gain on the heating process but much effect of integral gain on it.on it.

  • PDF

Calcium Current in the Unfertilized Egg of the Hamster

  • Haan, Jae-Hee;Cho, Soo-Wan;Yang, Young-Sun;Park, Young-Geun;Park, Hong-Gi;Chang, Gyeong-Jae;Kim, Yang-Mi;Park, Choon-Ok;Hong, Seong-Geun
    • The Korean Journal of Physiology
    • /
    • v.28 no.2
    • /
    • pp.215-224
    • /
    • 1994
  • The presence of a calcium current $(i_{Ca^{2+}})$ passed via a specific channel was examined in the unfertilized hamster egg using the whole-cell voltage clamp technique. Pure inward current was isolated using a $Ca^{2+}-rich$ pipette solution containing 10 mM TEA. This current was independent of external $Na^+$ and was highly sensitive to the $Ca^{2+}$ concentration in the bathing solution, indicating that the inward current is carried by $Ca^{2+}$. The maximal amplitude was $-4.12{\pm}0.58nA\;(n=12)$ with 10mM $Ca^{2+}$ at -3OmV from a holding potential of -8OmV. This current reached its maximum within 20ms beyond -3OmV and decayed rapidly with an inactivation time constant $({\tau})$ of 15ms. Activation and inactivation of this $i_{Ca^{2+}}$ was steeply dependent on the membrane potential. The $i_{Ca^{2+}}$ began to activate at the lower voltage of -55 mV and reached its peak at -35 mV, being completely inactivated at potentials more positive than -40 mV. These result suggest that $i_{Ca^{2+}}$ in hamster eggs passes through channels with electrical properties similar to low voltage-activated T-type channels. Other results from the present study support this suggestion; First, the inhibitory effect of $Ni^{2+}\;(IC_{50}=13.7\;{\mu}M)$ was more potent than $Cd^{2+}\;(IC_{50}=123\;{\mu}M)$. Second, $Ba^{2+}$ conductance was equal to or below that of $Ca^{2+}$. Third, $i_{Ca^{2+}}$ in hamster eggs was relatively insensitive to nifedipine $(IC_{50}=96.6\;{\mu}M)$, known to be a specific t-type blocker. The physiological role of $i_{Ca^{2+}}$ in the unfertilized hamster eggs remains unclear. Analysis from steady-state inactivation activation curves reveals that only a small amount of this current will pass in the voltage range $(-70{\sim}-30\;mV)$ which partially overlaps with the resting membrane potential. This current has the property that it can be easily activated by a weak depolarization, thus it may trigger a certain kind of a intracellular event following fertilization which may cause oscillations in the membrane potential.

  • PDF

On-site Application of a Vehicle Tunnel Ventilation Simulator (도로터널 환기시뮬레이션 모델 현장적용 연구)

  • 이창우;김효규
    • Tunnel and Underground Space
    • /
    • v.11 no.4
    • /
    • pp.319-327
    • /
    • 2001
  • Introduction of new design tools has been required to optimally design and operate the ventilation system of long vehicle tunnels.. The demand has led to wide spread use of the simulation technique throughout the would to analysis the dynamic relationship among the variables associated with vehicle tunnel ventilation. This paper aims at performing on-site study at local tunnels to test the applicability of NETVEN, a simulation model vehicle tunnel ventilation. The study was carried out at four urban as well as highway tunnels model of vehicle tunnel ventilation. The study was carried out at four urban as well as highway tunnels employing different ventilation systems as well as traffic methods. There were some discrepancies sound between the simulation output and measurements and the following four factors are considered to mainly cause those disagreement. (1) The real situation shows distinctive transient and retarding characteristics with respect to air flow and contaminant dispersion, while ventilation forces are not steady-state and in particular those traffic and climatic variables show significant instantaneous variation. (3) Near the exit portal, the CO levels show bigger differences. The general trend is that data with higher CO concentrations carry bigger discrepancies. Turbulent diffusion is though to be the main reason for it and also contribute to the fact hat the highest CO concentrations are found at the locations somewhat inward, not at the exit portals. (4) Higher traffic rate results in higher discrepancies of ventilation velocity. Along with the exhaust characteristics, the vehicle aerodynamic characteristics need to be studied continuously in order to reduce the velocity disagreement.

  • PDF

Rotordynamic Analysis of a Dual-Spool Turbofan Engine with Focus on Blade Defect Events (블레이드 손상에 따른 이축식 터보팬 엔진의 동적 안정성 해석)

  • Kim, Sitae;Jung, Kihyun;Lee, Junho;Park, Kihyun;Yang, Kwangjin
    • Tribology and Lubricants
    • /
    • v.36 no.2
    • /
    • pp.105-115
    • /
    • 2020
  • This paper presents a numerical study on the rotordynamic analysis of a dual-spool turbofan engine in the context of blade defect events. The blades of an axial-type aeroengine are typically well aligned during the compressor and turbine stages. However, they are sometimes exposed to damage, partially or entirely, for several operational reasons, such as cracks due to foreign objects, burns from the combustion gas, and corrosion due to oxygen in the air. Herein, we designed a dual-spool rotor using the commercial 3D modeling software CATIA to simulate blade defects in the turbofan engine. We utilized the rotordynamic parameters to create two finite element Euler-Bernoulli beam models connected by means of an inter-rotor bearing. We then applied the unbalanced forces induced by the mass eccentricities of the blades to the following selected scenarios: 1) fully balanced, 2) crack in the low-pressure compressor (LPC) and high pressure compressor (HPC), 3) burn on the high-pressure turbine (HPT) and low pressure compressor, 4) corrosion of the LPC, and 5) corrosion of the HPC. Additionally, we obtained the transient and steady-state responses of the overall rotor nodes using the Runge-Kutta numerical integration method, and employed model reduction techniques such as component mode synthesis to enhance the computational efficiency of the process. The simulation results indicate that the high-vibration status of the rotor commences beyond 10,000 rpm, which is identified as the first critical speed of the lower speed rotor. Moreover, we monitored the unbalanced stages near the inter-rotor bearing, which prominently influences the overall rotordynamic status, and the corrosion of the HPC to prevent further instability. The high-speed range operation (>13,000 rpm) coupled with HPC/HPT blade defects possibly presents a rotor-case contact problem that can lead to catastrophic failure.

A Comparative Study on Effective Factors Related to Home Nursing Care in Hospital and Community-based Care in Korea (한국 가정간호사업의 유형별 비교분석)

  • Kim, Sung-Sil
    • Research in Community and Public Health Nursing
    • /
    • v.9 no.1
    • /
    • pp.181-199
    • /
    • 1998
  • This study was designed to examine Home Nursing Care in Hospital-based and Community-based programs. This study investigates actual conditions of nursing needs and demands of clients and their family and the state of home nursing services. We hope that this study will improve upon the current home nursing care system. In Korea Home-Nursing Care programs are still developing and only now becoming a part of the health care delivery system. The data was collected by a questionaire the clients developed and modified through literature review by this writer and through 10 nurses who are members of 4 hospital and 3 community- based agencies. In this study 173 clients were selected. The study lasted from Oct. 1997 to March of 1998. The results show that the average age was 64.3, years older than most women clients (63.0%), the average age of a caregiver was 50.9 years old and most were female(77%). Two types of agency clients with a significant difference between social conditions [25.7%] used some form of insurance; 54.3% had the spouse pay expenses; pay 58.5% son and daughters of Hospital-based agencies: patients of social workers were 24.0%, the highest in the community agency. The condition of patients was 63.2% of the foley and nelaton catheter insertion at hospital based agencies. The range of nursing services offered is one of the highest among the 34 kinds of servies including nasogastric tube management basic nursing, ROM exercise, bladder irrigation, wound and sore dressing. For an effective care service factors that disturb each program such as a non-cooperatative family as well as patients themselves need to be lessened. Further more, the following must be emphasized, supportive counsel 27.0%, steady care for patient, 13.3%maintain a sense of security(11.7%), dressing sores and nutrition(10.0%). Although there were a large number of home nursing care services in the community, policy changes have gathered momentum. Fortunately, the scope and level at legal support will be increased in the future. The program should intergrate and link the district or community together. A project to develop a community based home nursing system as soon as possible should be developed. In conclusion, home nursing care nurses training curriculum should be strengthened.

  • PDF

Suggestions for the Activation of the Elementary Science Camp through the Present Status of Operation and Preference Survey (초등과학캠프의 운영 실태와 선호도 조사를 통한 활성화 방안)

  • Kwon, Nanjoo;Kim, Sangyong;Na, Sanghoon
    • Journal of Science Education
    • /
    • v.34 no.2
    • /
    • pp.306-319
    • /
    • 2010
  • The purpose of this study is to pursue suggestions for the activation of the elementary science camp through the present status of operation and preference survey; examined 50 elementary science camps conducted since year 2004, and surveyed 590 people of students, parents and teachers around Seoul and Gyeonggi province. This study also explores ways of issues and solutions through interviews with five officials of the elementary science camp. This study drew data from the present status of the elementary science camp, the state of camp participation, student's preference, interviews with camp managers. The following are suggestions for the activation of the elementary science camp based on the results of this study; First, the elementary science camp especially in charge of science-related association or office of education should be enlarged, and other private institute or organization should prepare for specialized programs and expert teachers. Second, insufficient camp spot should be solved and participation fee differentials should be alleviated. Third, the period of the camp and its announcement should be various, so that students have more opportunities. In conclusion, managing elementary science camp needs specialism, and continuing effort, because it is related to many important matters such as theme, period, place, participation expenses, guiding teacher, number of student, program organization, student's preference, and method of notice. Therefore, this study insists steady cooperation, continuing endeavor, and appropriate support system for elementary science camps on a nationwide scale.

  • PDF

Estimation of the Survival Rate in Fish Population -Mackerel and Horse Mackerel in the Coastal Waters of Korea- (어획대상 어류의 생잔율 추정 -한국 연안의 고등어, 전갱이-)

  • SHIN Sang-Taek
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.14 no.4
    • /
    • pp.253-259
    • /
    • 1981
  • A study was made to find out a new method of calculating the survival rate of a fish population from length composition and growth equation. 1. In the steady state of the fish population, let the total mortality rate be z, the age of complete recruitment a, the oldest age in the catch b and the average between the age of complete recruitment and the oldest age in the catch Ut, then we have $$U_{t}\;=\;\frac{a-b\;{e xp}\{-z(b-a)\}}{1-\;{e xp}\{-z(b-a)\}}+\frac{1}{z}{\cdots}{\cdots}{\cdots}{\cdots}{\cdots}$$(1) And let b be infinite, then we obtain $$Z=\frac{1}{U_t-a}{\cdots}{\cdots}{\cdots}{\cdots}{\cdots}{\cdots}$$ (2) 2. Calculating numerical value of $U_t$ from age composition table and growth equation, and substitute in (1) for it, we may obtain the value of z and $e^{-z}$. 3. This method is applied to a case of mackerel and horse mackerel in the coastal waters of Korea, with the following results : Total mortality rate-Mackerel : 0.87909, Horse mackerel : 2.22327, Survival rate-Mackerel : 0.41516, Horse Mackerel : 0.10825, 95 percent confidence Interval of survival rate-Mackerel : $0.35966{\sim}0.47264$, Horse mackerel : $0.06897{\sim}0.14974$

  • PDF

Detecting Peripheral Nerves in the Elbow using Three-Dimensional Diffusion-Weighted PSIF Sequences: a Feasibility Pilot Study

  • Na, Domin;Ryu, Jaeil;Hong, Suk-Joo;Hong, Sun Hwa;Yoon, Min A;Ahn, Kyung-Sik;Kang, Chang Ho;Kim, Baek Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.20 no.2
    • /
    • pp.81-87
    • /
    • 2016
  • Purpose: To analyze the feasibility of three-dimensional (3D) diffusion-weighted (DW) PSIF (reversed FISP [fast imaging with steady-state free precession]) sequence in order to evaluate peripheral nerves in the elbow. Materials and Methods: Ten normal, asymptomatic volunteers were enrolled (6 men, 4 women, mean age 27.9 years). The following sequences of magnetic resonance images (MRI) of the elbow were obtained using a 3.0-T machine: 3D DW PSIF, 3D T2 SPACE (sampling perfection with application optimized contrasts using different flip angle evolution) with SPAIR (spectral adiabatic inversion recovery) and 2D T2 TSE (turbo spin echo) with modified Dixon (m-Dixon) sequence. Two observers used a 5-point grading system to analyze the image quality of the ulnar, median, and radial nerves. The signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) of each nerve were measured. We compared 3D DW PSIF images with other sequences using the Wilcoxon-signed rank test and Friedman test. Inter-observer agreement was measured using intraclass correlation coefficient (ICC) analysis. Results: The mean 5-point scores of radial, median, and ulnar nerves in 3D DW PSIF (3.9/4.2/4.5, respectively) were higher than those in 3D T2 SPACE SPAIR (1.9/2.8/2.8) and 2D T2 TSE m-Dixon (1.7/2.8/2.9) sequences (P < 0.05). The mean SNR in 3D DW PSIF was lower than 3D T2 SPACE SPAIR, but there was no difference between 3D DW PSIF and 2D T2 TSE m-Dixon in all of the three nerves. The mean CNR in 3D DW PSIF was lower than 3D T2 SPACE SPAIR and 2D T2 TSE m-Dixon in the median and ulnar nerves, but no difference among the three sequences in the radial nerve. Conclusion: The three-dimensional DW PSIF sequence may be feasible to evaluate the peripheral nerves around the elbow in MR imaging. However, further optimization of the image quality (SNR, CNR) is required.

Numerical Analysis of the Temperature Distribution Considering the Wall Thermal Conductivity in Compartment Fire (구획 화재 시 벽면의 열적 특성을 고려한 온도분포 해석결과)

  • You, Woo Jun;Ko, Kwon Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.644-648
    • /
    • 2019
  • This study examined effects of the wall thermal conductivity coefficients on the thermal fluid phenomenon of a compartment fire. The reduced scale compartment was 0.4 m in width, 0.6 m in length and 0.6 m in height with a fire-board, which has a thermal conductivity coefficient of $0.18W/m{\cdot}K$. The local temperature at a 0.37 m height and the overall heat release rate were measured under the following experiment conditions: a $0.12m^2$ opening area and $0.01m^2$ pool size of a gasoline fire. The numerical results obtained by the Fire Dynamic Simulation were compared with the experimentally measured temperature. The deviations were within 10 % in the period of the steady state for maximum heat release rate (4.8 kW). The numerical results show that the average temperature of the compartment wall decreases by approximately 71 % with increasing thermal conductivity coefficient from $0.1W/m{\cdot}K$ to $100.0W/m{\cdot}K$ on the fixed heat release rate.