• Title/Summary/Keyword: Steady State Performance

검색결과 1,419건 처리시간 0.029초

Numerical investigation of steady state characteristics and stability of supercritical water natural circulation loop of a heater and cooler arrangements

  • Rai, Santosh Kumar;Kumar, Pardeep;Panwar, Vinay
    • Nuclear Engineering and Technology
    • /
    • 제53권11호
    • /
    • pp.3597-3611
    • /
    • 2021
  • The present paper studies the thermal-hydraulic behaviour of the rectangular supercritical natural circulation loop (SCNCL) using numerical model of one dimensional. Then the results of this model is confirmed with experimental and benchmark results. Variations with several geometric parameters like loop diameter, riser length, and heater length and operating conditions like heater inlet enthalpy, pressure, friction factor, and inlet and exit loss coefficient on steady-state performance are investigated for various orientations like HHHC, HHVC, VHVC and VHHC of the heater and cooler. The chances of existing static instability (Ledinegg excursion) has been investigated, which reveals that it can arise only in a low inlet enthalpy condition, far from the suggested various orientations of heater and cooler.

가변 스텝 크기를 적용한 FC-MMA 블라인드 등화 알고리즘의 성능 개선 (A Performance Improvement of FC-MMA Blind Equalization Algorithm based on Varying Step Size)

  • 임승각
    • 한국인터넷방송통신학회논문지
    • /
    • 제19권5호
    • /
    • pp.101-106
    • /
    • 2019
  • 본 논문에서는 nonconstant modulus 신호 전송에서 채널에서 발생되는 부호간 간섭 영향을 줄이기 위한 FC-MMA 적응 등화 알고리즘에 가변 스텝 크기를 적용하여 등화 성능을 개선할 수 있는 VSS-FC-MMA 알고리즘을 제안한 후, 이의 개선된 성능을 확인하였다. FC-MMA 는 적응 등화를 위한 오차 신호를 얻을 때 신호 심볼의 레벨수를 고려한 수정된 dispersion constant와 고정 스텝 크기를 적용하여 MMA의 수렴 속도를 개선할 수 있지만 정상 상태에서 등화 성능이 열화된다. 논문에서 제안하는 VSS-FC-MMA는 기존 FC-MMA와 가변 스텝 크기를 적용하므로서 정상 상태에서 등화 성능을 개선할 수 있으며, 이를 컴퓨터 시뮬레이션을 통해 확인하였다. 이를 위하여 동일한 채널과 신호대 잡음비를 적용할 때 알고리즘의 신호 복원 능력 및 성능 비교를 위한 지수로는 잔류 isi, MSE와 SER을 적용하였다. 시뮬레이션의 결과 제안 VSS-FC-MMA는 FC-MMA보다 잔여량과 SER 성능이 개선되지만, 수렴 속도에서는 1.7배 정도 늦어짐을 확인하였다.

매입형 영구자석 동기전동기의 능동외란제거제어를 이용한 추종제어 (Tracking Control of IPMSM using the Active Disturbance Rejection Control)

  • 전용호;채성병
    • 한국전자통신학회논문지
    • /
    • 제17권5호
    • /
    • pp.859-866
    • /
    • 2022
  • 능동 외란제거 제어기는 루엔버거 관측기를 이용하여 상태변수를 추정하여 제어기에서 외란을 제거하는 방식이다. 루엔버거 관측기는 정상상태에서 상수의 특징을 갖는 외란을 포함하는 비선형항을 상태변수로 정의하여 추정한다. 추정된 상태변수 값을 비례적분 제어기와 적분비례 제어기에 보상하여 개선된 속도 추종 성능을 보일 수 있다. 추정된 상태의 오차는 부하변동의 경우 1.9 [%] 이내임과 정상상태 상태 추종 오차가 영으로 수렴함을 보여 상태 추종 제어기의 외란 제거성능을 보임을 확인할 수 있다.

PD+I-type fuzzy controller using Simplified Indirect Inference Method

  • Kim, Ji-Hoon;Jeon, Hae-Jin;Chun, Kyung-Han;Park, Bong-Yeol
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.179.5-179
    • /
    • 2001
  • Generally, while PD-type fuzzy controller has good performance in transient period, it has uniform steady state error of response. To improve limitations of PD-type fuzzy controller, we propose a new fuzzy controller to improve the performance of transient response and to eliminate the steady state error of response. In this paper, PD-type fuzzy controller is used a simplified indirect inference method(SIIM). When the SIIM is applied, the proposed method has the capability of the high speed inference and adapting with increasing the number of the fuzzy input variables easily. The outputs of this controller are the output calculated by PD-type fuzzy controller and the accumulated error scaling factor. Here, the accumulated error scaling factor is adjusted by fuzzy rule according to the system state variables. To show the usefulness of the proposed controller, it is applied to 0-type 2nd-order linear system.

  • PDF

변형된 디지탈 Costas loop에 관한 연구 (II) 잡음이 있을 경우의 성능 해석 (Analysis of Modified Digital Costas Loop Part II : Performance in the Presence of Noise)

  • 정해창;은종관
    • 대한전자공학회논문지
    • /
    • 제19권3호
    • /
    • pp.37-45
    • /
    • 1982
  • 본 논문은 변형된 디지탈 Costas loop에 관한 논문으로서 제1부의 계속이다. 본 제2부 논문에서는 시스템에 잡음이 있을 경우 그의 성능을 해석하였다. 입력신호가 white Gaussian 잡음이 첨가되면 고려되는 DPLL의 noise process는 phase error detertor의 tan-1(·)함수에 의해서 Rician이 됨을 보였다. 이 경우 Chapman-Kolmogorov 방정식을 수치적으로 풀므로써 1차와 2차 loop phase error의 steady state probability density함수, mean 및 variance를 얻었으며 이 결과를 컴퓨터 시뮬레이tus에 의해서 입중하였다.

  • PDF

An FPGA-Based Modified Adaptive PID Controller for DC/DC Buck Converters

  • Lv, Ling;Chang, Changyuan;Zhou, Zhiqi;Yuan, Yubo
    • Journal of Power Electronics
    • /
    • 제15권2호
    • /
    • pp.346-355
    • /
    • 2015
  • On the basis of the conventional PID control algorithm, a modified adaptive PID (MA-PID) control algorithm is presented to improve the steady-state and dynamic performance of closed-loop systems. The proposed method has a straightforward structure without excessively increasing the complexity and cost. It can adaptively adjust the values of the control parameters ($K_p$, $K_i$ and $K_d$) by following a new control law. Simulation results show that the line transient response of the MA-PID is better than that of the adaptive digital PID because the differential coefficient $K_d$ is introduced to changes. In addition, experimental results based on a FPGA indicate that the MA-PID control algorithm reduces the recovery time by 62.5% in response to a 1V line transient, 50% in response to a 500mA load transient, and 23.6% in response to a steady-state deviation, when compared with the conventional PID control algorithm.

스마트 무인기 추진기관의 천이 모사 프로그램 개발 (Development of Transient Simulation Program for Smart UAV Propulsion System)

  • 이창호;기자영
    • 한국추진공학회지
    • /
    • 제15권6호
    • /
    • pp.63-69
    • /
    • 2011
  • 스마트 무인기의 엔진은 터보 축 엔진이지만 추진계통 제어는 회전익 항공기와 고정익 항공기에 필요한 특성을 모두 가져야 한다. 향후 전자식 엔진제어기를 개발하기 위해서는 틸트 로터 항공기의 엔진 운용 경험과 데이터를 축적할 필요가 있다. 이를 위해 정상상태 및 천이 상태에서의 엔진성능을 예측할 수 있는 프로그램을 활용하여 비행시험 데이터를 보완할 수 있다. 본 연구에서는 비행시험으로부터 수집한 엔진성능 데이터를 이용하여 동적 거동 해석 프로그램을 개발하고, 비행시험 결과 및 정상상태 엔진성능예측 프로그램으로 계산한 결과와 비교하여 프로그램의 정확도를 검증하였다.

중형항공기용 터보팬엔진의 정상상태 성능해석 및 동적모사에 관한 연구 (I) (A Study on Steady-State Performance Analysis and Dynamic Simulation for Medium Scale Civil Aircraft Turbofan Engine (I))

  • 공창덕;고광웅;기자영
    • 한국추진공학회지
    • /
    • 제2권2호
    • /
    • pp.47-55
    • /
    • 1998
  • 중형항공기용 터보팬엔진의 설계점, 탈설계점에 대한 정상상태 및 천이상태 성능해석을 수행하였다. 정상상태 성능해석은 설계점으로 선정한 지상최대추력조건과 탈설계점으로 선정한 최대상승조건과 순항조건에서 수행하였으며 부분부하 성능해석 결과 저압압축기 회전속도 90%RPM에서 가장 연료소모율이 적어 경제적임을 확인하였다. 천이상태 성능해석은 각각의 비행조건에서 연료의 Step증가, Ramp증가, Ramp감소, Step 증가 후 Ramp 감소의 경우에 대하여 수행하였다. 천이상태의 성능해석을 위해서는 압축기와 터빈의 일에 대한 조합이 필요한데, 일의 조합방정식에 포함된 잉여 토오크의 적분에는 Modified Euler Method를 적용하였다. 천이상태 성능해석 결과, 모든 비행조건에서 Step 및 Ramp 증가의 경우 고압압축기의 터빈입구온도가 제한온도를 초과하며, 최대상승조건에서 연료를 Step 또는 5.5초 이내의 Ramp 증가시킬 경우 고압압축기에서 실속이 발생함을 확인하였다.

  • PDF

Introduction of Generator Unit Controller and Its Tuning for Automatic Generation Control in Korean Energy Management System (K-EMS)

  • Park, Min-Su;Chun, Yeong-Han
    • Journal of Electrical Engineering and Technology
    • /
    • 제6권1호
    • /
    • pp.42-47
    • /
    • 2011
  • Automatic generation control (AGC) is an important function for load frequency control, which is being implemented in Energy Management System (EMS). A key feature of AGC is to back up governors to enhance the performance of frequency control. The governor regulates system frequency in several to ten seconds, while the droop control concept results in steady-state control error. AGC is a supplementary tool for compensation of the steady-state error caused by the droop setting of the governors. As the AGC target is delivered to each generator as an open loop control target, the generator output is not guaranteed to follow the AGC target. In this paper, we introduce generating unit controller (GUC) control block, which has the purpose of enabling the generator output to track the AGC target while maintaining the governor performance. We also address the tuning methods of GUC for better performance of AGC in the Korea Energy Management System (K-EMS).

단결정 실리콘 성장기의 성능향상을 위한 직경 제어 (The Diameter Control for improved performance of the Crystal Grower)

  • 이석원;박종식;이진우
    • 조명전기설비학회논문지
    • /
    • 제18권4호
    • /
    • pp.49-59
    • /
    • 2004
  • 본 연구에서는 실제의 산업현장(MEMC Korea)에서 생산 공정에 투입되고 있는 단결정 실리콘 성장기 CZ-150 Crystal Grower의 직경을 자동으로 제어하는 시스템의 성능을 개선하기 위한 제어기를 설계하였다. 설계된 제어기의 설계파라미터들의 효용성을 컴퓨터 시뮬레이션을 통해 확인하고, 제안된 제어기가 항상 정상상태 오차가 존재하는 기존의 PD제어기보다 성능이 우수함을 보였다.