Steady-state and transient performance for the medium scale civil aircraft turbofan engine was analyzed. Steady-state performance was analyzed on maximum take-off condition, maximum climb condition, and cruise condition. At 90%RPM of the low pressure compressor, the partload performance was economized. The transient performance was analyzed with cases of the step increase, the ramp increase, the ramp decrease, and the step increase and ramp decrease for the input fuel flow. For the transient performance analysis, work matching between compressor and turbine was needed. Modified Euler method was used the integration of residual torque in work matching equation. At all flight condition, the overshoot of the high pressure turbine inlet temperature was appeared in the step and ramp increase case, and the surge of high pressure compressor was appeared in the step increase case and the ramp increase case within 5.5 seconds of maximum climb condition.

중형항공기용 터보팬엔진의 설계점, 탈설계점에 대한 정상상태 및 천이상태 성능해석을 수행하였다. 정상상태 성능해석은 설계점으로 선정한 지상최대추력조건과 탈설계점으로 선정한 최대상승조건과 순항조건에서 수행하였으며 부분부하 성능해석 결과 저압압축기 회전속도 90%RPM에서 가장 연료소모율이 적어 경제적임을 확인하였다. 천이상태 성능해석은 각각의 비행조건에서 연료의 Step증가, Ramp증가, Ramp감소, Step 증가 후 Ramp 감소의 경우에 대하여 수행하였다. 천이상태의 성능해석을 위해서는 압축기와 터빈의 일에 대한 조합이 필요한데, 일의 조합방정식에 포함된 잉여 토오크의 적분에는 Modified Euler Method를 적용하였다. 천이상태 성능해석 결과, 모든 비행조건에서 Step 및 Ramp 증가의 경우 고압압축기의 터빈입구온도가 제한온도를 초과하며, 최대상승조건에서 연료를 Step 또는 5.5초 이내의 Ramp 증가시킬 경우 고압압축기에서 실속이 발생함을 확인하였다.