회전기 고정자 권선의 부분방전 진단을 위한 평면 Patch Sensor 설계 (The Design of a patch Sensor for Partial Discharge diagnosis in Rotating Machine Stator Windings)

  • 양상현;임광진;박노준;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.97-98
    • /
    • 2008
  • In 6.6kV Rotary Machine Stator Windings, Corona Discharge, Discharge at Conductor Surface, Slot Discharge and Endwinding Discharge is happended by electronic degradation. Also, if Partial Discharge cause in inner-part of Rotary Machine Stator Windings, it will be happended voltage and current pulse. In case of discharge spark, RF electromagnetic wave, which transmits at discharge position, can happen. To detect this kind of RF electromagnetic wave efficiently, we have designed Planar Antenna Sensor with the CST MWS simulation program. Also we have confined the application possibility, which can analyzes the partial discharge in Rotary Machine Stator Windings. In the Future, sample of planar antenna sensor will be able to compare with the data of simulation by CST MWS program.

  • PDF

고압전동기 고정자 권선의 절연상태 평가 (Assessment of Insulation Condition in High Voltage Motor Stator Windings)

  • 김희동;박의갑;박완조
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 E
    • /
    • pp.2392-2395
    • /
    • 1999
  • This paper describes to access the insulation deterioration condition of the stator windings in six high voltage motors. Nondestructive tests have been carried out on stand-still motors. These tests include ac current increase rate($\Delta$I), delta tan delta(${\Delta}tan{\delta}$), and maximum partial discharge(PD). AC current and $tan{\delta}$ were measured by Schering bridge. The measurement of PD patterns were conducted using digital partial discharge detector. PD patterns were observed treeing and internal discharges in Motor 1 and 2. The stator windings of two motors were found to be in a poor condition and their were recommended to rewind. The stator. windings of four motors were judged to be in serviceable condition.

  • PDF

6.6kV 회전기 고정자 권선에서 부분방전 진단을 위한 평판 안테나 센서 설계 (The Design of a Planar Antenna Sensor for Partial Discharge diagnosis in 6.6kV Rotary Machine Stator Windings)

  • 임광진;키아우소륀;신동훈;박노준;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 Techno-Fair 및 추계학술대회 논문집 전기물성,응용부문
    • /
    • pp.222-223
    • /
    • 2007
  • In 6.6kV Rotary Machine Stator Windings, Corona Discharge, Discharge at Conductor Surface, Slot Discharge and Endwinding Discharge is happended by electronic degradation. Also, if Partial Discharge cause in inner-part of Rotary Machine Stator Windings, it will be happended voltage and current pulse. In case of discharge spark, RF electromagnetic wave, which tranmits at discharge position, can happen. To detect this kind of RF electromagnetic wave efficiently, we have designed Planar Antenna Sensor with the CST MWS simulation program. Also we have confined the application possibility, which can analize the partial discharge in Rotary Machine Stator Windings. In the Future, sample of planar antenna sensor will be able to compare with the data of simulation by CST MWS program.

  • PDF

운전중인 대형 터빈발전기에서 절연상태 평가 (Assessment of Insulation Condition in Operating Large Turbine Generator)

  • 김희동
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권6호
    • /
    • pp.324-329
    • /
    • 2004
  • Six stator slot couplers(SSC) and a flux probe sensor installed on the stator winding slots of large turbine generator. Assessment of insulation condition has been based upon the measurements of partial discharge(PD) of stator windings and shorted-turn of rotor windings in operating large turbine generator. The maximum PD magnitude(Qm), normalized quantify number(NQN), PD pattern and shorted-turn were measured using on-line insulation condition monitoring system. The NQN and Qm of slot PD side in the phase A are indicated the highest value in six SSC sensors. Monitoring system results showed that discharge at conductor surface and internal discharge were detected at the surface of stator winding and in voids of the groundwall insulation. Insulation of stator and rotor windings in large turbine generator was judged to be in good condition.

13[kV]급 수력발전기 고정자 권선의 운전 및 정지 중 진단시험 현장적용 평가 및 분석 (Site Evaluation and Application of the On-line and Off-line Test for the 13[kV] Class Hydropower Generator Stator Windings)

  • 장정호;이동근;이흥호
    • 조명전기설비학회논문지
    • /
    • 제25권11호
    • /
    • pp.73-82
    • /
    • 2011
  • The solid insulation system of stator windings in high voltage rotational machines is usually aging in accordance with long time operation. The partial discharge test have been known to check whether insulation deterioration exist or not, and the PD test can effectively diagnose a solid insulation condition regardless of during operation(on-line) or not(off-line). The on-line PD measurement have proven to be a successful technique in monitoring stator insulation condition nowadays. This paper describes the characteristics of comparing the on-line PD measurement data using PDMS-HG(Partial Discharge Monitoring System for Hydro-electric Generator) installed in field with the off-line diagnosis measurement data(insulation resistance, winding resistance, PI, ${\Delta}tan{\delta}$ and PD) on hydro generator(13[kV]) stator windings. These results make good use of managing rotational machines through evaluating the solid insulation condition of stator windings.

고압전동기 고정자 권선의 절연열화 평가 (Assessment of Insulation Deterioration in Stator Windings of High Voltage Motor)

  • 김희동;공태식
    • 전기학회논문지
    • /
    • 제61권5호
    • /
    • pp.711-716
    • /
    • 2012
  • To assess the insulation deterioration of stator windings, diagnostic and AC breakdown tests were performed on the eleven high voltage (HV) motors rated at 6kV. After completing the diagnostic tests, the AC overvoltage test was performed by gradually increasing the voltage applied to the stator windings until electrical insulation failure occurred, to obtain the breakdown voltage. Stator winding of motors 1, 3, and 8 failed at above rated voltage at 14 kV, 13.8kV, and 16.4kV, respectively. The breakdown voltage of three motors was higher than expected for good quality windings in 6kV motors. Based on deterioration evaluation criteria, the stator winding insulation of eleven HV motors are confirmed to be in good condition. The turning point of the current, $P_{i2}$, in the AC current vs. voltage characteristics occurred between 5kV and 6kV, and the breakdown voltage was low between 13.8kV and 16.4kV. There was a strong correlation between the breakdown voltage and various electrical characteristics in diagnostic tests including Pi2.

발전기 권선에서의 신호전송 특성에 관한 연구 (A Study on the Signal Propagation Characteristics of Generator Windings)

  • 황돈하;김진봉;김용주;박명수;김택수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 하계학술대회 논문집 C
    • /
    • pp.1299-1303
    • /
    • 1995
  • The detection and measurement of partial discharge activity prevalent in the solid insulating systems of high-voltage generator stator windings has, for many years, been a recognized method of assessing the insulation condition of such systems. Partial discharge activity occurs at sites of degradation within, or at the surface of, stator's insulation systems under high voltage stressing. However, partial discharge pulses suffer from attenuation and distortion when transmitted along windings, because of the complex L-C network between windings. The mode of transmission varies with the signal frequency and is dependant on the geometrical configurations of windings. This paper reports the investigated results of the signal propagation characteristics along the windings when both sinusoidal signals and simulated partial discharge pulses are injected at the various positions of stator windings within the 25 MVA, 11 kV hydro generator. The on-line identification technique of partial discharge location in generator windings is also proposed in this study.

  • PDF

Inner Evaporative Cooling Wind Power Generator with Non-overlapping Concentrated Windings

  • Li, Wang;Wang, Haifeng
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • 제3권1호
    • /
    • pp.15-19
    • /
    • 2014
  • As the space of the wind power generator stator end is limited, it is difficult for us to place the inner evaporative cooling system in it. We use the non-overlapping concentrated windings scheme to solve the placing and cooling problem. The characteristic of a 5MW direct-driven permanent magnet generator with non-overlapping concentrated windings were analyzed under no-load, rating-load and short-circuit by (Finite Element Method) FEM for verification of design. We studied the connection methods of the stator windings and designed the end connection member. The heat dissipation of the stator end was simulated by FEM, the result showed that the end cooling could satisfy the wind generator operation needs. These results show that the direct-driven permanent magnet wind power generators with non-overlapping concentrated windings and inner evaporative cooling system can solve the cooling problem of wind power generator, and obtain good performance at the same time.

Feature Extraction of Simulated fault Signals in Stator Windings of a High Voltage Motor and Classification of Faulty Signals

  • Park, Jae-Jun;Jang, In-Bum
    • 한국전기전자재료학회논문지
    • /
    • 제18권10호
    • /
    • pp.965-975
    • /
    • 2005
  • In the case of the fault in stator windings of a high voltage motor. it facilitates certain destructive characteristics in insulations. This will result in a decreased reliability in power supplies and will prevent the generation of electricity, which will result in huge economic losses. This study simulates motor windings using normal windings and four faulty windings for an actual fault in stator winding of a high voltage motor. The partial discharge signals produced in each faulty winding were measured using an 80 PF epoxy/mica coupler sensor. In order to quantified signal waves its a way of feature extraction for each faulty signal, the signal wave of winding was quantified to measure the degree of skewness shape and kurtosis, which are both types of statistical parameters, using a discrete wavelet transformation method for each faulty type. Wave types present different types lot each faulty type, and the skewness and kurtosis also present different quantified values. The result of feature extraction was used as a preprocessing stage to identify a certain fault in stater windings. It is evident that the type of faulty signals can be classified from the test results using faulty signals that were randomly selected from the signal, which was not applied in the training after the training and learning period, by applying it to a back-propagation algorithm due to the supervising and learning method in a neural network in order to classify the faulty type. This becomes an important basis for studying diagnosis methods using the classification of faulty signals with a feature extraction algorithm, which can diagnose the fault of stator windings in the future.

수냉각 발전기 고정자 권선의 건조 과정 분석을 통한 누설 및 흡습 예측 진단에 관한 실험적 연구 (Experimental Study on Prediction and Diagnosis of Leakage and Water Absorption in Water-Cooled Generator Stator Windings by Drying Process Analysis)

  • 김희수;배용채;이욱륜;이두영
    • 대한기계학회논문집B
    • /
    • 제34권9호
    • /
    • pp.867-873
    • /
    • 2010
  • 수냉각 발전기 고정자 권선에서의 냉각수 누수 및 흡습에 의한 절연파괴 손상사례가 국내 및 국외에서 자주 발생되고 있다. 이러한 사고는 막대한 경제적 피해뿐만 아니라 전력의 안정적 공급 측면에서 매우 심각한 계통 사고로 연결될 수 있다. 특히 국내 발전기는 15년 이상 운전되어 열화가 진행된 발전기가 50% 이상이며, 계획예방정비 기간 중에 권선에서의 누설 및 흡습 권선이 종종 발견되고 있다. 기존에는 누수 시험 전 과정인 권선 건조 과정을 무시한 채 누수 시험 결과만으로 권선 누설 여부를 진단하였으나 본 논문에서는 누수 시험을 위한 준비 단계인 진공 건조 시의 권선 내부의 진공도 패턴 분석을 통해 권선 누설 및 흡습 여부를 예측진단할 수 있는 방법을 실험적으로 증명하였다.