• 제목/요약/키워드: Stator Windings

검색결과 264건 처리시간 0.044초

PC-SRD를 이용한 8/6 SRM 특성 해석 (Characteristics Analysis of 8/6 Switched Reluctance Motor Using PC-SR)

  • 조범규;정도영;이상호;이봉섭;하장호;오흥석;최경호;천동진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 B
    • /
    • pp.877-879
    • /
    • 2001
  • The switched reluctance motor (SRM) has a simple motor construction with no rotor windings. It also has simple concentrated windings on the stator windings. Thus it is expected to be a lower cost machine to manufacture than other motors. This paper has computed an optimal parameters asking for SRM drives using by PC-SRD that was programmed by T. J. E. Miller/M. Mcgilp. According to advanced angle and dwell angle, the output, efficiency, currents and torque were computed. The experiments with 8/6 SRM have tested.

  • PDF

철손을 고려한 자기저항 동기전동기의 정수 측정 및 동특성 예측 (Parameter Measurement and Dynamic Performance Estimation of Synchronous Reluctance Motor Considering Iron Loss)

  • 이정섭;홍정표;한성진;주수원
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.58-60
    • /
    • 1999
  • This paper presents dynamic performance prediction using Matlab / simulink after parameter estimation of synchronous reluctance motor considering iron loss. Test motor is 3 phase SynRM with the segmental rotor, rating power is 0.175KW. Experiment equipment is consists of testing motor, dynamometer, vector invertor dynamocontroller, and power analyser. The stator iron loss and rotor iron loss are modelled by additional windings on three-phase winding axis. These windings are transformed into d-q axis, and are represented as equivalent eddy current windings. P-Q circle diagram method and single phase standstill method are used to measure motor parameters considering iron loss.

  • PDF

IGBT PWM 인버터 구동 유도전동기 고정자 권선에서의 과도전압 분포특성 (Distribution Characteristics of Irregular Voltage in Stator Windings of IGBT PWM Inverter-Fed Induction Motors)

  • 황돈하;김용주;이인우;배성우;김동희;노체균
    • 전력전자학회논문지
    • /
    • 제8권4호
    • /
    • pp.351-358
    • /
    • 2003
  • 본 논문에서는 IGBT PWM 인버터 구동 유도전동기 고정자 권선에서의 스위칭 써지전압 분포특성을 분석하였다. 고정자 권선의 턴 및 코일간의 전압분포를 해석하기 위하여 케이블을 포함한 유도전동기의 등가모델을 제안하고, 유한요소법을 이용하여 고주파 파라메타를 산출하였다 또한, 유도전동기, IGBT PWM 인버터 및 케이블등에 대한 전체 시스템의 EMTP 시뮬레이션을 통하여 인버터 상승시간, 케이블 길이 및 스위칭 주파수 등의 영향에 따른 전압분포를 분석하였다. 380[V], 50[HP] 유도전동기 고정자 권선을 대상으로 한 전압분포 특성실험을 통하여 인버터용 전동기 설치 및 과전압 억제용 필터 설계시의 유용한 자료를 제시하였다.

고정자 권선용 F종 주절연 테이프의 전기적 특성 (Electrical characteristics of class-F groundwall insulation tapes for stator windings)

  • 김태희;강명국;이재권;손삼용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1679-1681
    • /
    • 2004
  • Class-F and B resin-rich type insulating tapes are generally used for the ground wall insulations of respective air-cooled and water-cooled stator windings in larger turbine generators. In this paper, their electrical properties coupled with aging times in higher temperature than designed one in normal condition were experimentally investigated and the results of two comparative tests were presented on the existing class-F resin-rich type tape and a developed one after curing. The resin-rich tapes currently used arc composed of six and a half 3-layer sheets that arc structured with mica paper, the top and bottom supports of it respectively, and the epoxy resin to bind them tightly. The results for breakdown voltage and strength on the cured specimens were presented, which were composed of the unaged, the aged accelerated for one, two, and three thousand hours at 180 $^{\circ}C$. The surface and volume resistivities on them were measured and the results are also presented to make a comparative test for the initial electrical characteristics.

  • PDF

고정자 권선용 F종 주절연테이프의 기계적 특성 (Mechanical characteristics of class-F groundwall insulation tapes for stator windings)

  • 김태희;강명국;이재권;손삼용
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 C
    • /
    • pp.1676-1678
    • /
    • 2004
  • Class-F resin-rich type insulating tapes are generally used for the groundwall insulations of the large turbine generators with air-cooled and hydrogen-cooled stator windings. In this paper, mechanical strength properties degraded over aging time in higher temperature than designed one in normal condition were experimentally investigated and the results of comparative tests were presented on the existing class-F resin-rich type tape and a developed one after curing. The resin-rich insulating tapes with composite material of Mica/Epoxy/support currently were used in this test. The tests for tensile and flexural strength properties were conducted with the specimens which were composed of unaged and the aged specimens accelerated for one, two, and three thousand hours at 180 $^{\circ}C$. The tensional strength was only measured for the unaged specimens and the results are also presented to make a comparative test for their initial mechanical characteristics.

  • PDF

전초전도 호모폴라 모터의 3차원 자계해석 및 회로상수 추출 (3D Field Analysis And Circuit Parameter Calculation of Superconducting Homopolar Synchronous Motor)

  • 조영한;성탄일;김영선;박일한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.700_701
    • /
    • 2009
  • In comparison with conventional motors, Superconducting Homopolar Synchronous Motors (SHSMs) have advantages that it generates high magnetic field by superconducting winding. Therefore, superconducting coil used in SHSM can reduce the motor size and enhance the motor efficiency for high torque applications under the space constraints for propulsion system. During the design process of SHSM, it is required to evaluate the performance of initial design model, that is accurately analyzed using 3D magnetic field modeling large air-gap and flux distribution of axial direction is properly taken into account. In this paper, we analyze magnetic field of a homopolar motor with a 4-pole homopolar rotor and a stator of 3 phase windings. The field analysis is done using 3D finite element analysis which can reflect the end effect and overhang winding. And we extract mutual inductances between a rotor wind and the 3 stator windings. The extracted inductances are used for evaluation of overall motor performances that are calculated with generalized circuit theory of electrical machines.

  • PDF

Magnetic Field Calculation and Multi-objective Optimization of Axial Flux Permanent Magnet Generator with Coreless Stator Windings

  • Zhu, Jun;Li, Shaolong;Song, Dandan;Han, Qiaoli;Li, guanghua
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1586-1595
    • /
    • 2018
  • For the problem that the complexity of 3-D modeling and multi parameter optimization, as well as the uncertainty of the winding factor of axial flux permanent magnet generator with coreless windings. The complex 3-D model was simplified into 2-D analytic model, and an analytical formula for the winding factor that adapting different coreless stator winding is proposed in this paper. The analytical solution for air-gap magnetic fields, no-load back EMF, electromagnetic torque, and efficiency are calculated by using this method. The multiple objective and multivariable optimization of the maximum fundamental and the minimum harmonic content of back EMF are performed by using response surface methodology. The proposed optimum design method was applied to make a generator. The generator was tested and the calculated results are compared with the proposed method, which show good agreements.

고압회전기 고정자 권선의 부분방전 측정 (Partial Discharge Measurements of High Voltage Rotating Machine Stator Windings)

  • 김희동;이영준;공태식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1828-1830
    • /
    • 2003
  • Partial discharge(PD) tests are used to evaluate the insulation condition of stator windings in two 4.16kV and three 6.6kV motors. These tests were conducted using a conventional partial discharge detector(PDD) and turbine generator analyzer(TGA). Off-line PD measurements were performed on five high voltage motors. PD magnitudes ranged from 1000 pC to 5400 pC at the normal line-to-ground voltage. Five high voltage motors have been equipped with 80pF epoxy-mica coupler on the motor terminal box. The PD pulse from sensors were measured with the TGA instrument. TGA summarizes each plot with two Quantities such as the peak PD magnitude(Qm) and the total PD activity(NQN). The defect mechanisms of high voltage motor can be associated with PD patterns such as internal, slot and conductor surface discharges. The PDD and TGA test results of No. 4 motor showed that internal discharge was detected in voids of the groundwall insulation.

  • PDF

고압회전기 고정자 권선에서 발생하는 부분방전 진단을 위한 Sierpinski 정삼각형 프랙탈 센서 (The Design of a Regular Triangle Fractal Sensor for Partial Discharge diagnosis in High Voltage Rotary Machine Stator Windings)

  • 임광진;키아우소륀;신동훈;공태식;김희동;박노준;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1486-1487
    • /
    • 2007
  • In case of stator windings in 6.6 kV high voltage rotary machine, the pulse resonance shows in 1.1 MHz - 2 MHz and 20 MHz - 200 MHz as the range of low frequency. Actually, the peak of partial discharge appears the range which generated resonance frequency, and is confirmed in the range of 1.1 MHz -2 MHz. In this paper, the Sierpinski triangle fractal sensor have designed by using the CST MWS for confirming the partial discharge in 20 MHz - 200 MHz. As a result, we have obtained the result that the resonance pulse freqency is correlated with the partial discharge freqency in 20 MHz - 200 MHz.

  • PDF