• Title/Summary/Keyword: Statistical Testing

Search Result 1,201, Processing Time 0.032 seconds

A Study on the quantitative Evaluation of Spasticity Implementing Pendulum Test (진자실험을 통한 경직의 정량적 평가에 관한 연구)

  • Lim H.K.;Cho K.H.;Kim B.O.;Chae J.M.;Lee Y.S.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.3 s.61
    • /
    • pp.303-309
    • /
    • 2000
  • An accurate quantitative biomechanical evaluation for the spasticity caused by the disorder of central nervous system was made in this study. A sudden leg dropper was designed to generate objective testing environment at every trial. 3-dimensional motion analysis system(Elite. B.T.S. Italy) was used to measure kinematic data which were angle. and angular velocity of a lower limb. A program was developed to analyze the kinematic data of lower limb motion. and dynamic EMG data at the same time. To evaluate spasticity quantitatively. total 26 parameters including 14 parameters newly driven were analyzed, and statistical analysis were made for bilateral correlations. Results showed possibility to make accurate quantitative and objective evaluation for spasticity with various new parameters using new devices and program.

  • PDF

A Study on Estimating Daily Yield from Morning or Afternoon Milking Records with Unequal Milking Intervals (불균등 착유 시간간격의 오전·오후 유량기록을 이용한 1일 산유량 추정에 관한 연구)

  • Cho, Y.M.;Park, B.H.;Ahn, B.S.
    • Journal of Animal Science and Technology
    • /
    • v.46 no.5
    • /
    • pp.707-718
    • /
    • 2004
  • This study was conducted to evaluate the adequacy of an alternative a.m. - p.m. testing scheme for milk yield in comparison with the official test method based on weighing two milkings within 24 h. A total of 8,309 p.m. milking weights and 6,767 am. milking weights from 72 Holstein cows raised at N.L.R.I. were collected between October 2000 and November 2001. Seven statistical models were fitted to the data to derive formulas for estimating daily milk yields from morning or evening yields. In general, use of evening milkings less accurately estimated than did use morning rnilkings. Although the models do not differ much in the correlations between estimated and true daily milk yields, systematic under- and overestimation of daily milk yields were observed in all models with the exception of model 7, which accounted for heterogeneous variances by parity class, milking interval class, and lactation stage by fitting separate regression formulas within each combination of three factors.

The effect of various commercially available bleaching agents on the microshear bond strength of composite resin to enamel

  • Chang, Hoon-Sang;Cho, Kyung-Mo;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.3
    • /
    • pp.219-225
    • /
    • 2004
  • This study evaluated the microshear bond strength of composte resin to teeth bleached with commercial whitening strips and compared with those bleached with home bleaching gel. Twelve extracted human central incisors were cut into pieces and central four segments were chosen from each tooth and embedded in acrylic resin. Four blocks with 12 tooth segments embedded in acrylic resin were acquired and numbered from group one to group four. Group 1 was bleached with Crest Whitestrips, group 2 with Claren, group 3 with Opalescence tooth whitening gel (10% carbamide peroxide). Group 4 was used as control. The bleaching procedure was conducted for 14 days according to the manufacturer's instructions ; the bleaching strips twice a day for 30 min and the bleaching gel once a day for 2hr. After bleaching, composite resin (Filtek Supreme) was bonded to the enamel surfaces with a self-etching adhesive (Adper Prompt L-Pop) using Tygon tube. Microshear bond strength was tested with a universal testing machine (EZ-test). The data were statistically analysed by one-way ANOVA. The study resulted in no statistical differences in microshear bond strength between the tooth segments bleached with 2 different whitening strips and bleaching gel. It can be concluded that the effect of bleaching with either commercial whitening strips or bleaching gel on enamel is minimal in bonding with self-etching adhesive to composite resin.

A Study on Prevalence and Risk Factors for Varicose Veins in Nurses at a University Hospital

  • Yun, Myeong-Ja;Kim, Young-Ki;Kang, Dong-Mug;Kim, Jong-Eun;Ha, Won-Choon;Jung, Kap-yeol;Choi, Hyun-Woo
    • Safety and Health at Work
    • /
    • v.9 no.1
    • /
    • pp.79-83
    • /
    • 2018
  • Background: Lower-limb varicose veins (VVs) are common and known to have a higher prevalence among people who work in occupations requiring prolonged standing. In the Republic of Korea, however, VV-related occupational factors have seldom been examined. This study was conducted to assess the prevalence of VVs among nurses, an occupational group considered to be at high risk of VVs, and determine the occupational risk factors of prolonged standing. Methods: Between March and August 2014, a questionnaire survey coupled with Doppler ultrasonography was conducted on the nurses working at a university hospital. Results: A total of 414 nurses participated in the survey and diagnostic testing. From the survey analysis and test results, the prevalence of VVs in nurses was estimated to be 16.18%. Significant factors for venous reflux were age [odds ratio (OR) = 1.06, 95% confidence interval (CI) = 1.03-1.10], pregnancy (OR = 2.15, 95% CI = 1.17-3.94), and delivery (OR = 2.02, 95% CI = 1.08-3.78). The statistical significance of these factors was verified after risk adjustment for sociodemographic factors (OR = 3.40, 95% CI = 1.27-9.09). Conclusion: Factors significantly associated with venous reflux were increasing age and prolonged working hours (${\geq}4hours$) in a standing position (OR = 2.80, 95% CI = 1.08-7.25), even after risk adjustment for sociodemographic factors. This study is significant in that an objective diagnosis of VVs preceded the analysis of the risk factors for VV incidence, thus verifying objectively that VVs are associated with occupations requiring prolonged hours of working in a standing position.

A Study on the Life Characteristic of an Automotive Water-pump Bearing Using the Accelerated Test Method (가속시험법을 활용한 자동차용 워터펌프 베어링의 수명특성에 관한 연구)

  • Yang, Hui Sun;Shin, Jung Hun;Park, Jong Won;Sung, Baek Ju
    • Tribology and Lubricants
    • /
    • v.31 no.2
    • /
    • pp.35-41
    • /
    • 2015
  • A water-pump located in the cooling area of a car circulates cooling water. A particular bearing element, known as a water-pump bearing, installed in the rotating part carries the entire load. The failure of this water-pump bearing has a direct impact on the failure of the automobile engine, and so securing its reliability is crucial. Several researchers have examined the design principles of the water-pump bearing, but there are no reports on the life characteristic of the bearing yet. Herein, we report the construction of test equipment to reproduce the spalling of the roller contact, which is the main failure mode of the chosen water-pump bearing. We chose the radial load as an accelerated stress factor and validated the failure mode by monitoring the surface defects. We conducted the accelerated life test after determining the accelerated stress level through a combination of finite element analysis and a preliminary test. In the life tests, we used an accelerometer to perform failure diagnosis. In the last stage of this study, we present a statistical reliability analysis. Thus, we fully estimated the shape parameter of the water-pump bearing, accelerating level on the load , and the lifetime (MTTF and B10 life) under real use conditions, and finally proposed an interval estimation value considering the uncertainty of the estimated value.

TENSILE STREGNTH BETWEEN MACHINABLE CERAMIC AND DENTIN CEMENTED WITH LUTING COMPOSITE RESIN CEMENTS (합착용 복합레진시멘트로 합착한 Machinable Ceramic과 상아질 사이의 인장강도에 대한 실험적 연구)

  • Cho, Byeong-Hoon
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.487-501
    • /
    • 1998
  • In the case of CAD/CAM ceramic inlay restorations, if isthmus width is widened too much, it may cause fracture of remaining tooth structure or loss of bonding at the luting interface because of excessive displacement of buccal or lingual cusps under occlusal loads. So to clarify the criterior of widening isthmus width, this study was designed to test the tensile bond strength and bond failure mode between dentin and ceramic cemented with luting composite resin cements. Cylindrical ceramic blocks(Vita Cerec Mark II, d=4mm) were bonded to buccal dentin of 40 freshly extracted third molars with 4 luting composite resin cements(group1 : Scotchbond Resin Cement/Scotchbond Multi-Purpose, group2 : Duolink Resin Cement/ All-Bond 2, group3: Bistite Resin Cement/Ceramics Primer, and group4:Superbond C&B). Tensile bond test was done under universal testing machine using bonding and measuring alignment blocks(${\phi}ilo$ & Urn, 1992). After immersion of fractured samples into 1 % methylene blue for 24 hours, failure mode was analysed under stereomicroscope and SEM. Results: The tensile bond strength of goup 1, 2 & 4 was $13.97{\pm}2.90$ MPa, $16.49{\pm}3.90$ MPa and $16.l7{\pm}4.32$ MPa, respectively. There was no statistical differences(p>0.05). But, group 3 showed significantly lower bond stregnth($5.98{\pm}1.l7$ MPa, p<0.05). In almost all samples, adhesive fractures between dentin and resin cements were observed. But, in group 1, 2 & 4, as bond strength increased, cohesive fracture within resin cement was observed simultaneously. And, in group 3, as bond strength decreased, cohesive fracture between hybrid layer and composite resin cement was also observed. Cohesive fracture within dentin and porcelain adhesive fracture were not observed. In conclusion, although adhesive cements were used in CAD/CAM -fabricated ceramic inlay restorations, the conservative priciples of cavity preparation must be obligated.

  • PDF

Indirect measure of shear strength parameters of fiber-reinforced sandy soil using laboratory tests and intelligent systems

  • Armaghani, Danial Jahed;Mirzaei, Fatemeh;Toghroli, Ali;Shariati, Ali
    • Geomechanics and Engineering
    • /
    • v.22 no.5
    • /
    • pp.397-414
    • /
    • 2020
  • In this paper, practical predictive models for soil shear strength parameters are proposed. As cohesion and internal friction angle are of essential shear strength parameters in any geotechnical studies, we try to predict them via artificial neural network (ANN) and neuro-imperialism approaches. The proposed models was based on the result of a series of consolidated undrained triaxial tests were conducted on reinforced sandy soil. The experimental program surveys the increase in internal friction angle of sandy soil due to addition of polypropylene fibers with different lengths and percentages. According to the result of the experimental study, the most important parameters impact on internal friction angle i.e., fiber percentage, fiber length, deviator stress, and pore water pressure were selected as predictive model inputs. The inputs were used to construct several ANN and neuro-imperialism models and a series of statistical indices were calculated to evaluate the prediction accuracy of the developed models. Both simulation results and the values of computed indices confirm that the newly-proposed neuro-imperialism model performs noticeably better comparing to the proposed ANN model. While neuro-imperialism model has training and test error values of 0.068 and 0.094, respectively, ANN model give error values of 0.083 for training sets and 0.26 for testing sets. Therefore, the neuro-imperialism can provide a new applicable model to effectively predict the internal friction angle of fiber-reinforced sandy soil.

Failure Mechanism and Long-Term Hydrostatic Behavior of Linear Low Density Polyethylene Tubing (선형저밀도 폴리에틸렌 튜빙의 파손 메커니즘과 장기 정수압 거동)

  • Weon, Jong-Il;Chung, Yu-Kyoung;Shin, Sei-Moon;Choi, Kil-Yeong
    • Polymer(Korea)
    • /
    • v.32 no.5
    • /
    • pp.440-445
    • /
    • 2008
  • The failure mechanism and failure morphology of linear low density polyethylene (LLDPE) tubing under hydrostatic pressure were investigated. Microscopic observations using video microscope and scanning electron microscope indicate that the failure mode is a brittle fracture including cracks propagated from inner wall to outer wall. In addition, oxidation induction time and Fourier transform infrared spectroscopy results show the presence of exothermic peak and the increase in carbonyl index on the surface of fractured LLDPE tubing, due to thermal-degradation. An accelerated life test methodology and testing system for LLDPE tubing are developed using the relationship between stresses and life characteristics by means of thermal acceleration. Statistical approaches using the Arrhenius model and Weibull distribution are implemented to estimate the long-term life time of LLDPE tubing under hydrostatic pressure. Consequently, the long-term life time of LLDPE tubing at the operating temperature of $25^{\circ}C$ could be predicted and also be analyzed.

Usage Patterns and Incidence of Thyroid-related Adverse Events in Patients Treated with PD-1 Inhibitors (PD-1 억제제의 사용패턴 및 갑상선 관련 유해사례 발현 양상 분석)

  • Hwang, Seoyoung;Kim, Heuijae;Chung, Seonyoung;Min, Myungsook;Suh, Dong-Churl
    • Korean Journal of Clinical Pharmacy
    • /
    • v.31 no.3
    • /
    • pp.188-197
    • /
    • 2021
  • Objective: PD-1 inhibitors have demonstrated improved health outcomes in cancer patients. PD-1 inhibitors are well-tolerated and associated with immune-related adverse events. The objectives of this study are to analyze use patterns of PD-1 inhibitors in patients with cancer and to investigate the incidence of thyroid-related adverse reactions in patients treated with PD-1 inhibitors. Methods: The study included patients who had been administered PD-1 inhibitors (either nivolumab or pembrolizumab) at the Samsung Medical Center between October 1, 2016 and June 30, 2017. Data was collected from electronic medical records and tested using Mann-Whitney tests and Chi-Square tests for statistical significance. Associations between PD-1 inhibitors and incidence of adverse events were tested using Cox regression for age, gender, BMI, ECOG PS and medication. Results: Two hundred fifteen patients were identified as eligible for analyses. Thyroid-related adverse events occurred in 20% of patients (n=43). Thyroid function tests (TFTs) was performed in 109 patients (50.7%). Positive results of PD-L1 testing were found in 53.2% of the 94 patients who had the test. Approved doses of nivolumab (3 m/kg) and pembrolizumab (200 mg) were administered in 70.4% and 53% of patients, respectively. The analysis of risk factor of thyroid-related adverse reaction did not show statistically significant differences (Cox regression). Conclusion: Thyroid-related adverse events are common in patients treated with PD-1 inhibitors and hypothyroidism is the most frequent adverse reaction. Routine TFTs monitoring is strongly recommended to evaluate thyroid function in real-world clinical practice.

Sequential use of real-time polymerase chain reaction and enzyme-linked immunosorbent assay techniques verifies adulteration of fermented sausages with chicken meat

  • Benli, Hakan;Barutcu, Elif
    • Animal Bioscience
    • /
    • v.34 no.12
    • /
    • pp.1995-2002
    • /
    • 2021
  • Objective: Detection of adulteration in processed meats is an important issue for some countries due to substitution of beef with a cheaper source of protein like poultry. In this study, the presence of chicken meat was investigated using real-time polymerase chain reaction (real-time PCR) and enzyme-linked immunosorbent assay (ELISA) techniques to verify adulteration of fermented sausage samples. Methods: A total of 60 commercial samples were collected from 20 establishments in three replicates including 10 fermented sausage manufacturers and 10 butchers to investigate the presence of chicken meat with the sequential use of real-time PCR and ELISA techniques. In addition, pH, moisture content, water activity and color values of the samples were determined. Results: Both real-time PCR and ELISA showed agreement on the presence or absence of chicken meat in 55 out of 60 fermented sausage samples and chicken meat was identified with both methods in 16 samples. Five samples produced inconsistent results for the presence of chicken meat in the first run. Nevertheless, the presence of chicken meat was verified with both methods when these samples were analyzed for the second time. In addition, the average physico-chemical values of the fermented sausage samples tested positive for chicken meat were not significantly different from some of those fermented sausage samples tested negative for the chicken meat. Conclusion: The sequential use of real-time PCR and ELISA techniques in fermented sausages could be beneficial for the government testing programs to eliminate false negatives for detection of adulteration with chicken meat. Furthermore, consumers should not rely on some of the quality cues including color to predict the adulteration of fermented sausages with chicken meat since there were no statistical differences among some of the samples tested positive and negative for chicken meat.