• Title/Summary/Keyword: Statistical Testing

Search Result 1,201, Processing Time 0.031 seconds

A study on the usage satisfaction of multi-type handpieces with equipped air-jet function (Air-jet기능을 장착한 멀티형 복합유닛 핸드피스의 사용 만족도 조사)

  • Kim, Im-Sun;Choi, Byung-Hwan
    • Journal of Technologic Dentistry
    • /
    • v.37 no.3
    • /
    • pp.169-178
    • /
    • 2015
  • Purpose: This study was to investigate usage satisfaction of multi type handpiece with equipped air-jet function Methods: The subjects of this study through the survey was conducted for fifty-nine dental technicians in Daegu and Gyeongsangbukdo from the May 7 to 19, after the June 23 to July 4 2014. The survey was about the function and quality through user testing environment by cutting zirconia specimens using appliance for zirconia. The collected date was analyzed by the statistical program SPSS Win Ver 19.0 for the satisfaction of handpiece and control system. To test for significance on each item, p<0.05 had been decided a standard. General characteristics and relationship between the handpiece and control system was performed correlation analysis. Results: The results of this study is as follows. 35 dental technicians had 1~2 years career in zirconia part as the highest 59.3%, 95% of subjects expected that the prospects for the zirconia material have bright prospects. The satisfaction of multi type handpiece and control system design and function showed a significant difference. Subjects satisfied with the design and function of the multi type showed negative correlation with those of Standard. The satisfaction of multi type handpiece showed 3.37 points of air jet, 3.05 points of noise level, 2.69 points of water flow rate, and 1.98 points of cruise function. Sample differences in all parameters showed a statistically higher difference. Conclusion: High-speed cutting mechanism of multi-type is recommended working with zirconia materials and the multi-type unit combined handpiece motor, air-turbine and air-gun will be expected the increase of user due to the high satisfaction of air jet.

Evaluation of the genotoxicity and cytotoxicity in the buccal epithelial cells of patients undergoing orthodontic treatment with three light-cured bonding composites by using micronucleus testing

  • Toy, Ebubekir;Yuksel, Sengul;Ozturk, Firat;Karatas, Orhan Hakki;Yalcin, Muhammet
    • The korean journal of orthodontics
    • /
    • v.44 no.3
    • /
    • pp.128-135
    • /
    • 2014
  • Objective: This study evaluated the cytotoxicity and genotoxicity of fixed orthodontic treatment with three different light-cured orthodontic bonding composites by analyzing micronucleus (MN) formation in the buccal mucosa during a 6-month period. Methods: Thirty healthy volunteers were selected from consecutive patients referred for orthodontic treatment. Equilibrium 2 brackets and molar tubes (Dentaurum) were bonded with three different lightcured orthodontic bonding composites-Transbond XT (3M Unitek), Kurasper F (Kuraray Europe), or GrenGloo (Ormco Corporation)- to all teeth in both arches. Exfoliated buccal epithelial cells were scraped from the middle part of the inner cheeks with sterile cement spatulas before treatment and at 1, 3, and 6 months after treatment. MNs and nuclear alterations, such as karyorrhexis (KR), karyolysis (KL), and binucleated cells (BNs), were scored under a light microscope. Repeated measure ANOVA was used to calculate statistical differences in degenerative nuclear abnormalities. Results: MN rates did not significantly differ among different time points within the same cell type (p > 0.05). In contrast, the number of BNs in buccal epithelial cells significantly increased in all composite groups (p < 0.01, Transbond XT; p < 0.001, Kurasper F and GrenGloo). KL frequency significantly increased between the beginning and end of the study in the Kurasfer F ($0.80{\pm}0.79$ to $1.90{\pm}1.10$; p < 0.05) and GrenGloo ($1.30{\pm}1.06$ to $2.40{\pm}1.08$; p < 0.05) groups. Conclusions: After 6 months of fixed orthodontic treatment with different light-cured composites, morphological signs of cytotoxicity were observed but genotoxic effects were absent.

A study on Development of Artificial Neural Network (ANN) for Preliminary Design of Urban Deep Ex cavation and Tunnelling (도심지 지하굴착 및 터널시공 예비설계를 위한 인공신경망 개발에 관한 연구)

  • Yoo, Chungsik;Yang, Jaewon
    • Journal of the Korean Geosynthetics Society
    • /
    • v.19 no.1
    • /
    • pp.11-23
    • /
    • 2020
  • In this paper development artificial neural networks (ANN) for preliminary design and prediction of urban tunnelling and deep excavation-induced ground settlement was presented. In order to form training and validation data sets for the ANN development, field design and measured data were collected for various tunnelling and deep-excavation sites. The field data were then used as a database for the ANN training. The developed ANN was validated against a testing set and the unused field data in terms of statistical parameters such as R2, RMSE, and MAE. The practical use of ANN was demonstrated by applying the developed ANN to hypothetical conditions. It was shown that the developed ANN can be effectively used as a tool for preliminary excavation design and ground settlement prediction for urban excavation problems.

Reliability Evaluation of Extrapolated Failure Load of Drilled Shafts Embedded in Weathered Rock (풍화암에 근입된 현장타설말뚝의 외삽 파괴하중 신뢰성 분석)

  • Jung, Sung-Jun;Lee, Sang-Inn;Jeon, Jong-Woo;Kim, Myoung-Mo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.09a
    • /
    • pp.993-1000
    • /
    • 2009
  • In general, a drilled shaft embedded in weathered rock has a large load bearing capacity. Therefore, most of the load tests are performed only up to the load level that confirms the pile design load capacity, and stopped much before the failure load of the pile is attained. If a reliable failure load value can be extracted from the premature load test data, it will be possible to greatly improve economic efficiency as well as pile design quality. The main purpose of this study is to propose a standard for judging the reliability of the failure load of piles that is obtained from extrapolated load test data. To this aim, eleven static load test data of load-displacement curves were obtained from testing of piles to their failures from 3 different field sites. For each load-displacement curve, loading was assumed as 25%, 50%, 60%, 70%, 80%, and 90% of the actual pile bearing capacity. The limited known data were then extrapolated using the hyperbolic function, and the failure load was re-determined for each extrapolated data by the ASCE 20-96 method (1997). Statistical analysis was performed on the reliability of the re-evaluated failure loads. The results showed that if the ratio of the maximum-available displacement to the failure-load displacement exceeds 0.6, the extrapolated failure load may be regarded as reliable, having less than a conservative 20% error on average. The applicability of the proposed standard of judgment was also verified with static load test data of driven piles.

  • PDF

Wuqinxi Daoin exercise for osteoporosis: A Systematic Review (오금희 도인 운동이 골다공증에 미치는 영향 : 체계적 문헌 고찰)

  • Park, In-Hwa;Kim, Byung-Jun;Lim, Kyeong-Tae;Shin, Byung-Cheul;Hwang, Man-suk;Hwang, Eui-Hyoung
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.12 no.2
    • /
    • pp.31-42
    • /
    • 2017
  • Objectives : This review aims to assess the effect of Wuqinxi exercise for osteoporosis. Methods : We searched 9 electronic databases(Pubmed, EMBASE, Cochrane Library, CAJ, Oasis, KISS, NDSL, KMBASE, KISTI) and related 2 journals until November 2017. We included randomized controlled trials(RCTs) of testing Wuqinxi exercise for osteoporosis. The methodological quality of RCTs related assessed by the Cochrane risk of bias tool. Results : 12 RCTs were eligible in our inclusion criteria. No statistical differences were found between the Wuqinxi versus no intervention, Wuqinxi plus antiosteoporosis medications versus antiosteo-porosis medications on lumbar spine, femora bone mineral density (BMD). However, Wuqinxi significantly improved lumbar spine BMD compared with antiosteoporosis medications (P < 0.00001). Additionally, the results showed a remarkable effect in improving pain score(VAS) when Wuqinxi or Wuqinxi plus antiosteoporosis medications (P < 0.0005) was used. Conclusions : There is evidence of Wuqinxi exercise for osteoporosis with meta-analysis. However, our systematic review has limited evidence to support Wuqinxi exercise for osteoporosis. because of low quality of original articles and further well-designed RCTs should be encouraged.

  • PDF

A modified index for damage detection of structures using improved reduction system method

  • Arefi, Shahin Lale;Gholizad, Amin;Seyedpoor, Seyed Mohammad
    • Smart Structures and Systems
    • /
    • v.25 no.1
    • /
    • pp.1-22
    • /
    • 2020
  • The modal strain energy method is one of the efficient methods for detecting damage in the structures. Due to existing some limitations in real-world structures, sensors can only be located on a limited number of degrees of freedom (DOFs) of a structure. Therefore, the mode shape values in all DOFs of structures cannot be measured. In this paper, a modified modal strain energy based index (MMSEBI) is introduced to locate damaged elements of structures when a limited number of sensors are used. The proposed MMSEBI is based on the reconstruction of mode shapes using Improved Reduction System (IRS) method. Therefore, in the first step by employing IRS method, mode shapes in slave degrees of freedom are estimated by those of master degrees of freedom. In the second step, the proposed MMSEBI is used to located damage elements. In order to evaluate the efficiency of the proposed method, two numerical examples are considered under different damage patterns considering the measurement noise. Moreover, the universal threshold based on statistical hypothesis testing principles is applied to damage index values. The results show the effectiveness of the proposed MMSEBI for the structural damage localization when comparing with the available damage index named MESBI. The results demonstrate that the presented method can be used as a practical strategy for structural damage identification, especially when a limited number of sensors are installed on the structure. Finally, the combination of MMSEBI and IRS method can provide a reliable tool to identify the location of damage accurately.

Development of a Criterion for Efficient Numerical Calculation of Structural Vibration Responses

  • Kim, Woonkyung M.;Kim, Jeung-Tae;Kim, Jung-Soo
    • Journal of Mechanical Science and Technology
    • /
    • v.17 no.8
    • /
    • pp.1148-1155
    • /
    • 2003
  • The finite element method is one of the methods widely applied for predicting vibration in mechanical structures. In this paper, the effect of the mesh size of the finite element model on the accuracy of the numerical solutions of the structural vibration problems is investigated with particular focus on obtaining the optimal mesh size with respect to the solution accuracy and computational cost. The vibration response parameters of the natural frequency, modal density, and driving point mobility are discussed. For accurate driving point mobility calculation, the decay method is employed to experimentally determine the internal damping. A uniform plate simply supported at four corners is examined in detail, in which the response parameters are calculated by constructing finite element models with different mesh sizes. The accuracy of the finite element solutions of these parameters is evaluated by comparing with the analytical results as well as estimations based on the statistical energy analysis, or if not available, by testing the numerical convergence. As the mesh size becomes smaller than one quarter of the wavelength of the highest frequency of interest, the solution accuracy improvement is found to be negligible, while the computational cost rapidly increases. For mechanical structures, the finite element analysis with the mesh size of the order of quarter wavelength, combined with the use of the decay method for obtaining internal damping, is found to provide satisfactory predictions for vibration responses.

Testing the Reliability of the Pain Color Circle Measurement Tool (색채동통척도의 신뢰도 연구)

  • 김주희
    • Journal of Korean Academy of Nursing
    • /
    • v.21 no.3
    • /
    • pp.339-348
    • /
    • 1991
  • The study problem was to determine the reliability of the Stewart pain circle measurement tool with Korean subjects. The purpose was to assess the tool for potential use in research in Korea. The subjects were 95 primary school students and 103 university students in Seoul. The study was conducted from May to June 1990, using Stewart's pain color circle tool. To determine the difference in the rated intensity of the order of the pain color circles, statistical mean and standard deviation were employed. Item reliability and test - retest reliability were used to test for reliability. ANOVA and t-test were used to explore for differences in the rated intensity of the order of the pain color circles according to the subjects' general characteristics. The findings were as follows ; 1. Higher level pain intensity was assigned to color circle numbers 2, 4, and 6 (These contain large amounts of color). Lower level pain intensity was assigned to numbers 1, 3, and 5(These contain small amounts of color). Higher and lower levels of pain intensity selection patterns were the same as Stewart's but the highest rating of pain was different. The highest pain intensity rating was given to the color red in this study instead of black as in Stewart's test. 2. University students and primary school students' ratings were not very difteferent. 3. Pain color circle reliability was $\alpha$=0.3468, Test - retest reliability was supported (t=0.02~0.97, p=0.337~0.988) 4. Differences in the rating of the pain intensity order were related to the subjects' age and sex, but not to religion. It was concluded that the pain color circle measurement tool is worth for further study as a research instrument with both Korean adult and child clients for validity and reliability.

  • PDF

Altered Peripheral Nerve Excitability Properties in Acute and Subacute Supratentorial Ischemic Stroke (급성 및 아급성 천막상 허혈성 뇌졸중에서 발생하는 말초신경 흥분성 변화)

  • Seo, Jung Hwa;Ji, Ki Whan;Chung, Eun Joo;Kim, Sang Gin;Kim, Oeung Kyu;Paeing, Sung Hwa;Bae, Jong Seok
    • Annals of Clinical Neurophysiology
    • /
    • v.14 no.2
    • /
    • pp.64-71
    • /
    • 2012
  • Background: It is generally accepted that upper motor neuron (UMN) lesion can alter lower motor neuron (LMN) function by the plasticity of neural circuit. However there have been only few researches regarding the axonal excitability of LMN after UMN injury especially during the acute stage. The aim of this study was to investigate the nerve excitability properties of the LMNs following an acute to subacute supratentorial corticospinal tract lesion. Methods: An automated nerve excitability test (NET) using the threshold tracking technique was utilized to measure multiple excitability indices in median motor axons of 15 stroke patients and 20 controls. Testing of both paretic and non-paretic side was repeated twice, during the acute stage and subacute stage. The protocols calculated the strength-duration time constant from the duration-charge curve, parameters of threshold electrotonus (TE), the current-threshold relationship from sequential sub-threshold current, and the recovery cycle from sequential supra-threshold stimulation. Results: On the paretic side, compared with the control group, significant decline of superexcitablity and increase in the relative refractory period were observed during the subacute stage of stroke. Additionally, despite the absence of statistical significance, a mildly collapsing in ('fanning in') of the TE was found. Conclusions: Our results suggest that supratentorial brain lesions can affect peripheral axonal excitability even during the early stage. The NET pattern probably suggests background membrane depolarization of LMNs. These features could be associated with trans-synaptic regulation of UMNs to LMNs as one of the "neural plasticity" mechanisms in acute brain injury.

Landmark Recognition Method based on Geometric Invariant Vectors (기하학적 불변벡터기반 랜드마크 인식방법)

  • Cha Jeong-Hee
    • Journal of the Korea Society of Computer and Information
    • /
    • v.10 no.3 s.35
    • /
    • pp.173-182
    • /
    • 2005
  • In this paper, we propose a landmark recognition method which is irrelevant to the camera viewpoint on the navigation for localization. Features in previous research is variable to camera viewpoint, therefore due to the wealth of information, extraction of visual landmarks for positioning is not an easy task. The proposed method in this paper, has the three following stages; first, extraction of features, second, learning and recognition, third, matching. In the feature extraction stage, we set the interest areas of the image. where we extract the corner points. And then, we extract features more accurate and resistant to noise through statistical analysis of a small eigenvalue. In learning and recognition stage, we form robust feature models by testing whether the feature model consisted of five corner points is an invariant feature irrelevant to viewpoint. In the matching stage, we reduce time complexity and find correspondence accurately by matching method using similarity evaluation function and Graham search method. In the experiments, we compare and analyse the proposed method with existing methods by using various indoor images to demonstrate the superiority of the proposed methods.

  • PDF