• Title/Summary/Keyword: Station area

Search Result 2,198, Processing Time 0.033 seconds

Comparing the Service Coverages of Subways and Buses and Estimating the Walking Distances of Their Users (지하철과 버스의 서비스권역 비교 및 이용자들의 도보거리 추정 - 부산시를 중심으로 -)

  • Kim, Kyung Whan;Lee, Deok Hwan;Choi, Jong Moon;Oh, Il Sung
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.30 no.6D
    • /
    • pp.541-552
    • /
    • 2010
  • The light rail transit (LRT) having bus lines as subsystem is being constructed or planned in the suburban area of metropolitans and medium size cities. However, there is difficulty in establishing the service coverage (SC) of the LRT because the LRT is a completely new transit mode in Korea. The purpose of this study is to provide the basic data and techniques to be used for establishing the SC of the future LRT by understanding the SC characteristics of buses and subways and building models to estimate the walking distances of their users. Busan City is selected as the study city and the SC's of buses and subways are surveyed simultaneously. A total of 9 variables for 82 stations are collected and the cluster analysis is conducted about the variables. The station areas are divided to three types of CBD (Central Business District), sub-CBD and regional center based on the analysis. A station in each area is selected as the study station. At the walking distance (WD) analysis for each mode, the 80 percentile WD of the subway is 672 m and that of the bus is 472 m. In comparing the SC's of both modes by the type of station areas, there are not significant differences between the SC's of sub-CBD and regional center except CBD. At analysis of the relationship between the personal attributes and the WD, for subway users the WD of female is longer than that of male and apartment residents use subway more positively than single house residents do. For the models to estimate the walking distances, the simple regression models were built employing the income as independent variable by dividing the stations into CBD abd non-CBD stations.

Demonstration of 10kw Wind Turbine System at the King Sejong Station (극한환경에서의 소형풍력발전 실증운전)

  • Kim, Seok-Woo;Kyong, Nam-Ho
    • Journal of the Korean Solar Energy Society
    • /
    • v.26 no.4
    • /
    • pp.25-30
    • /
    • 2006
  • 10kW wind turbine has been successfully commissioned at the King Sejong station in April, 2006. The wind turbine installed is a part of the R&D program for developing a solid wind/diesel hybrid power control system for a remote area such as Antarctica. At the same time, the current research aims to develop an anti-icing and de-icing technologies for a small wind turbine rated under 50kW. Since its commissioning, the turbine has generated about 500kWh for 47days without any system faults. Although sufficient data have not been obtained yet, any trouble has not occurred in the wind/diesel hybrid system based on the current analysis. Concerning on the environmental impact by the wind turbine operation, the turbine is installed within the station boundary in order to meet the Madrid protocol. Therefore, wind turbine operation meets the international requirements for preservation of antarctic ecosystem.

A Study on the Surge Analysis for Grounding System of the Communication Base Station (통신기지국 접지계의 써어지해석)

  • Kim, Jae-Yee;Yoon, Tae-Yang
    • Proceedings of the KIEE Conference
    • /
    • 2004.07c
    • /
    • pp.2025-2027
    • /
    • 2004
  • The grounding system design of the communication base station can be on the unfavorable conditions to induce the safe designing because of the limited area of the communication base station and the week point of surge caused by the given geographical condition such as the top point of mountain. In this paper, it is examined throughly about the way of safe designing that can reduce GPR(Ground Potential Rise) within the normal frequency band. And it is also considered the effective counter plan to cope with a transient phenomena that happen when surge of scores MHz-band inserted.

  • PDF

Design and Construction of a Large Section Tunnel for a Subway Station (지하철 대단면 터널의 설계와 시공관리 사례)

  • 문상조;장석부;정준화
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.03a
    • /
    • pp.285-292
    • /
    • 1999
  • Recent development cases of transportation utilities using tunnelling method in metropolitan sites have been increased due to the heavily complex environments and restrictions of construction works. The progress of tunnel design and construction to be supported by the tunnel analysis and measurement techniques using computers have increased adoptions of large section tunnels. In this paper, many factors to be considered in designing large section tunnels are discussed and the case of the construction of the subway station tunnel which is recently completed is introduced. This tunnel has a width of 24 m, a height of 16 m, and a excavation section area of 366 ㎡.

  • PDF

Inspeciton for Ground Settlement and Its Contermeasurement Under ${\bigcirc}{\bigcirc}$-Station Passenger Way Adjacent to Ground Excavation (${\bigcirc}{\bigcirc}$역사 지하철 환승통로 주변지반 침하 원인 및 대책에 관한 연구)

  • Yoon, Tae-Gook;Choo, Jin-Ho;Kim, Hong-Kyun;Ko, Hee-Kyu;Han, Dong-Eun
    • Proceedings of the KSR Conference
    • /
    • 2011.10a
    • /
    • pp.2879-2884
    • /
    • 2011
  • Ground settlement has been occurred at asphalt pavement above ${\bigcirc}{\bigcirc}$ station passenger way adjacent to ground excavation with SPS method. In this study, emergency inspection has been conducted 4 detailed areas by KISTEC; SPS, sewage box, 50m box in subway, and ${\bigcirc}{\bigcirc}$ station. Field description and previous reports have been analyzed with the elapsed years. Not only precise inspection with several NDTs but also stability analysis by FLAC have been performed to estimated the tendency of settlement at sunk pavement area. Additional monitoring system and water analysis from sewage and SPS have been examined to scrutinize the reason and maintenance for settlement.

  • PDF

Development of Weight Type Rounded Snow Plate (중량식 원형 적설판 개발에 관한 연구)

  • Lee, Bu-Yong;Kim, Hyun-Chul
    • Atmosphere
    • /
    • v.19 no.1
    • /
    • pp.1-8
    • /
    • 2009
  • We need water equivalent unit data of snowfall for the purpose of forecast and hydrology related research area. This study developed new method of automatic recording snowfall as weight unit with circle type plate using stain-gauge loadcell. Field test of instrument carried out at Daegwallyeong Obs. Station from 20 to 23 Jan. 2008 during heavy snowfall. There is 74.2cm snow depth and 54.6mm precipitation by Daegwallyeong Obs. Station. But the instrument of this study recorded 71.0mm of precipitation amount. Because of different observation method can cause more 15.4mm than Daegwallyeong Obs. Station. But this study gives the possibility of observation of new snow fall measurement under freezing conditions of snow. From the observation data the density of snowfall calculated from 0.09 to $1015g/cm_3$ from the observation period. And have a good relations between manual observation and automatic observation data from this study instrument with slope of 1.35 to 1.39.

Development of WA-DGNSS Reference Station Software (광역보정시스템 기준국 소프트웨어 개발)

  • Choi, Wan Sik;Chhattan, Shah Sayed;Han, Woo Yong;Yun, Ho;Kee, Changdon
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2013.10a
    • /
    • pp.390-392
    • /
    • 2013
  • In the paper, design and implementation results of the reference station software are described for the WA-DGNSS that is currently developed in pseudo-realtime concept. The reference software is designed and implemented by applying the object oriented methodology.

  • PDF

Quantitative Fire Risk Assesment for the Subway Platform Types (지하철 승강장 형식에 따른 정량적 화재 위험성 평가)

  • Rie, Dong-Ho;Kim, Ha-Young
    • Journal of the Korean Society of Safety
    • /
    • v.21 no.6 s.78
    • /
    • pp.1-6
    • /
    • 2006
  • Subway platform is divided into Side-platform type and Center-platform type. In this study does quantitative fire risk assesment of subway platform types in numerical analysis by using CFD model. From the result of this study, 1) All exhaust mode was low-end result it seems most fire risk at Side-platform station. 2) All exhaust mode was low-end result it seems most fire risk at Center-Platform station. 3) When comparing same type exhaust mode of Side-platform and Center-platform that last thing was visible $9.1{\sim}72.34%$ low-end fire risk. Center-platform is more opera-tive than Side-platform that reduce fire risk when that was same dimension and external environment. Designer look upon a fire characteristic of subway platform types when he make smoke control air volume and platform area design.

Analysis of AIS Problems in Broad Communication Coverage (광역 통신권에서의 AIS 문제점 분석)

  • Kim, Byung-ok
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.430-432
    • /
    • 2013
  • AIS(Automatic Identification System) is a radionavigation equipment for exchanging safety related information between ships as well as ship and shore station, introduced by SOLAS convention and widely used especially in vessel traffic service. However, in an area of broad communication coverage of coast station, various problems may appear in receiving AIS data from ships. In this paper, AIS problems that may happen in broad communication coverage of coast station are analyzed using received data.

  • PDF

Chemical Control of Leaf Spot of Date Palm (Phoenix dactylifera) in Sultanate of Oman

  • Livingston, Sam;Mufargi, Khamis-Al;Sunkeli, Mehmood-Al
    • The Plant Pathology Journal
    • /
    • v.18 no.3
    • /
    • pp.165-167
    • /
    • 2002
  • Date palm (Phoenix dactylifera) is an important fruit and cash crop in Sultanate of Oman, occupying nearly 60% of the total cultivated area. However, leaf spots caused by Mycosphaerella tassiana, Alternaria spp., and Dreshcleri sp. have become a threat to date palm's cultivation in recent years. In this study, a field experiment was conducted to find out a suitable chemical spray program to control the disease. A prophylactic spray schedule with mancozeb (Dithane M45), copper oxychloride (Champion), and mancozeb+copper (Trimiltox) effectively controlled the disease when applied at a time when the disease severity index (DSI) was low, ranging from 0 to 1.68. Meanwhile, the disease did not decrease, but instead increased gradually, when the fungicide combination was applied when DSI was high, ranging from 1.78 to 5.37. It was concluded that fungicides should be applied at the early stage or before disease initiation in order to control the disease effectively.