• Title/Summary/Keyword: Static power

Search Result 1,526, Processing Time 0.022 seconds

Development of SSSC Power Flow Model and its Implementation into Continuation Power Flow Algorithm (전력조류계산을 위한 SSSC모델의 개발과 연속조류계산 알고리듬에의 적용)

  • Kim, Seul-Ki;Song, Hwa-Chang;Lee, Byong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 1999.07c
    • /
    • pp.1158-1160
    • /
    • 1999
  • This paper proposes a SSSC(Static Synchronous Series Compensator) power flow model to be incorporated into power flow calculation for the steady state analysis of the power system. SSSC provides controllable compensating voltage, which is in quadrature with the line current, over an capacitive and an inductive range, independently of the magnitude of the line current. This SSSC model is obtained from the injection model for series connected VSC(Voltage Source Converter) by adding a constraint that the injected voltage should be in quadrature with the line current. In this paper the static model is implemented into the continuation power-flow (CPF) program. It is shown that SSSC has its intrinsic superiority over TCSC in controllable power flow range.

  • PDF

Evaluation of Effects on Power System by Installing the Static Var Compensator (SVC 설치 운전에 따른 계통의 영향성 평가)

  • Yoon, Jong-Su;Kim, Yong-Hak;Kim, Soo-Yeol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.7
    • /
    • pp.1187-1193
    • /
    • 2010
  • This paper provides the methods for enhancing the stability with normal or emergency operating conditions in real power systems and copes with the unbalance of demand of reactive power due to the loss of facility, such as 765kV transmission line. In this paper, we focused on the maximum allowable transmission power(hereafter, MAXTP) in the metropolitan area. In order to increase the MAXTP, the application of reactive power compensators, SVC, and Shunt compensator and reactor, is analyzed as an enhancing method of stability and MAXTP. Particularly, the f-V analysis was performed for the postulated contingency, in order to evaluate the effects on SVC. Conclusively, the stability of power systems could be enhanced and the MAXTP is increased effectively with Dongseoul SVC which has the capacity 200MVAr.

A Comparative Study on the Effect of STATCOM and UPFC in the Static Analysis of Power Systems (전력계통의 정태해석에 미치는 STATCOM과 UPFC의 영향에 대한 비교 연구)

  • Kim, Deok-Young;Lee, Ji-Yeol;Kook, Kyung-Soo;Rho, Dae-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.214-216
    • /
    • 2000
  • This paper presents an comparative study on the effect of STATCOM and UPFC to the power system static analysis. The effect of STATCOM can be analyzed with PSS/E program which is generally used in power system analysis, while UPFC model for static analysis is not provided yet. Thus, UPFC is equivalently represented as a synchronous condenser and load, while the active and reactive power of the specific transmission line and the voltage of the bus is controlled appropriately. This procedure is implemented by IPLAN which is an external macro program of PSS/E. The simulation results show that UPFC is more effective to control the bus voltage than STATCOM, because UPFC can control not only the bus voltage where the parallel inverter is installed but also the active and reactive power flow in the transmission line where the series inverter is installed.

  • PDF

Individual DC Voltage Balancing Method at Zero Current Mode for Cascaded H-bridge Based Static Synchronous Compensator

  • Yang, Zezhou;Sun, Jianjun;Li, Shangsheng;Liao, Zhiqiang;Zha, Xiaoming
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.240-249
    • /
    • 2018
  • Individual DC voltage balance problem is an inherent issue for cascaded H-bridge (CHB) based converter. When the CHB-based static synchronous compensator (STATCOM) is operating at zero current mode, the software-based individual DC voltage balancing control techniques may not work because of the infinitesimal output current. However, the different power losses of each cell would lead to the individual DC voltages unbalance. The uneven power losses on the local supplied cell-controllers (including the control circuit and drive circuit) would especially cause the divergence of individual DC voltages, due to their characteristic as constant power loads. To solve this problem, this paper proposes an adaptive voltage balancing module which is designed in the cell-controller board with small size and low cost circuits. It is controlled to make the power loss of the cell a constant resistance load, thus the DC voltages are balanced in zero current mode. Field test in a 10kV STATCOM confirms the performance of the proposed method.

SVC coupled UPQC for reactive power compensation capacity increase and DC link voltage reduction (무효전력 보상 용량 증대 및 DC 링크 전압 저감을 위한 SVC 결합형 UPQC)

  • Pyo, Soo-Han;Park, Jang-Hyun;Oh, Jeong-Sik;Park, Tae-Sik
    • Journal of IKEEE
    • /
    • v.23 no.1
    • /
    • pp.99-106
    • /
    • 2019
  • This paper propose a new form of UPQC (Unified Power Quality Compensator) to compensate the current and voltage quality problems of nonlinear loads. The conventional UPQC system consists of a series inverter, a parallel inverter, and a common DC link. A new type of UPQC proposed is a parallel compensator with SVC (Static Var Compensator) added to compensate for the wide compensation range and low DC link voltage. The parallel inverter compensates the reactive power generated by the nonlinear load, and the series inverter compensates the sag and swell generated at the power supply side.

Stabilization of High-Voltage Static Var Compensator Using Switching Velocity and Temperature Control (스위칭 속도 및 온도 제어를 사용한 고압용 정지형 무효전력 보상장치의 안정화)

  • Kim, Yong-Tae;Lee, Chang-Seok
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.23 no.2
    • /
    • pp.107-112
    • /
    • 2013
  • In the paper, velocity controller of switching module and temperature controller for the high-voltage static var compensator are proposed. Because of the continuous increase in demand for electric power, transmission and distribution facilities of power plant are required. There is a bottleneck problem of transportation routes according to new construction and expansion of power transmission facilities. Therefore there are researches to maximize the utilization of existing facilities and to increase transmission capacity without new construction. The previous static var compensator detects voltage of input circuit of power, switches the SCR directly and generates switching noise. The proposed method increases switching velocity and decreases noise using switching control based on the voltage between both sides of SCR. Also the proposed method enhance the stability using realtime temperature control for heating of the system from increase of switching velocity. We experiment the velocity and temperature control of the proposed high-voltage static var compensator in the real environment and verify the performance of the proposed system by applying in the real field.

Experimental Study on the Aerodynamic Performance of a Cross-Flow Fan for the Various Leading Angles of a Rear-Guider for a Room Air-Conditioner (리어가이더 선단각도에 따른 룸에어콘용 관류홴의 공력성능에 관한 실험적 연구)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.17 no.3
    • /
    • pp.35-43
    • /
    • 2013
  • Generally, the chassis of an indoor RAC is composed of a rear-guider and a stabilizer. The aerodynamic performance of a cross-flow fan is strongly influenced by the various design factors of the chassis of an indoor RAC. The purpose of this paper is to select the optimum design factors through the aerodynamic performance of a cross-flow fan. The design factors are the leading angle of a rear-guider (${\theta}_1$), a stabilizer setup angle(${\theta}_2$), a rear-guider clearance(${\epsilon}_1$), and a stabilizer clearance(${\epsilon}_2$), respectively. As a result, the optimum design factors of an indoor RAC can be presented as a combination of ${\theta}_1=33^{\circ}$, ${\theta}_2=55^{\circ}$, ${\epsilon}_1=6{\sim}8mm$, and ${\epsilon}_2=7mm$ through the analysis of a static pressure coefficient and a static pressure efficiency.

Large Eddy Simulation on the Aerodynamic Performance of Three-Dimensional Small-Size Axial Fan with the Different Depth of Bellmouth (벨마우스 깊이가 다른 3차원 소형축류홴의 공력특성에 대한 대규모 와 모사)

  • Kim, Jang-Kweon;Oh, Seok-Hyung
    • Journal of Power System Engineering
    • /
    • v.19 no.6
    • /
    • pp.19-25
    • /
    • 2015
  • The unsteady-state, incompressible and three-dimensional large eddy simulation(LES) was carried out to analyze the aerodynamic performance of three-dimensional small-size axial fan(SSAF) with the different depth of bellmouth. The static pressure coefficients analyzed by LES predict a little bit larger than measurements except stall region regardless of the installation depth between SSAF and bellmouth. Moreover, static pressure efficiencies analyzed by LES show about maximum 30% at the actual operating point ranges, but measurements do not. Therefore, if the blades of conventional SSAF have some more rigidity and complete dynamic balance, the aerodynamic performance of SSAF will be some more improved. In consequence, LES shows the best prediction performance in comparison with any other Reynolds averaged Navier-Stokes(RANS) method.

Simulator Development for Training Auxiliary Power Supply in Electric Rolling Stock (전기 철도차량의 보조전원장치 실습용 시뮬레이터 개발)

  • Kim, Jae-Moon;Kim, Duk-Heon;Kim, Yuen-Chung
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.54 no.4
    • /
    • pp.192-197
    • /
    • 2005
  • This paper presents a development of the auxiliary power supply simulator for a electric rolling stock. An auxiliary power supplies are required for operating air conditioning units, ventilation fans, lighting and battery charging. Traditionally this function has been fulfilled by Motor-Alternator sets. In recent years, high performance of semiconductor and micro processor, availability and price have made three phase voltage source inverters as an attractive alternative to MA Sets. From the baseline model of the SIV(Static InVerter) for electric rolling stock, we designed the scale down model of the auxiliary power supply simulator consisting of an IGBT three phase voltage source inverter. The auxiliary power supply simulator can be used educatory purpose for training efficiently about operating principles of SIV.

Design of Robust Current Controller Using GA for Three Level 24-Pulse VSC Based STATCOM

  • Janaki, M.;Thirumalaivasan, R.;Prabhu, Nagesh
    • Journal of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.375-380
    • /
    • 2011
  • A STATic synchronous COMpensator (STATCOM) is a shunt connected voltage source converter (VSC) based FACTS controller using Gate Turn Off (GTO) power semiconductor devices employed for reactive power control. The operation principal is similar to that of a synchronous condenser. A typical application of a STATCOM is voltage regulation at the midpoint of a long transmission line for the enhancement of power transfer capability and/or reactive power control at the load centre. This paper presents the modeling of STATCOM with twenty four pulse three level VSC and Type-1 controller to regulate the reactive current or the bus voltage. The performance is evaluated by transient simulation. It is observed that, the STATCOM shows excellent transient response to step change in the reactive current reference. While the eigenvalue analysis is based on D-Q model, the transient simulation is based on both D-Q and 3 phase models of STATCOM (which considers switching action of VSC).