• Title/Summary/Keyword: Static power

Search Result 1,523, Processing Time 0.027 seconds

Modeling and Control of VSI type FACTS controllers for Power System Dynamic Stability using the current injection method

  • Park, Jung-Soo;Jang, Gil-Soo;Son, Kwang-M.
    • International Journal of Control, Automation, and Systems
    • /
    • v.6 no.4
    • /
    • pp.495-505
    • /
    • 2008
  • This paper describes modeling Voltage Sourced Inverter (VSI) type Flexible AC Transmission System (FACTS) controllers and control methods for power system dynamic stability studies. The considered FACTS controllers are the Static Compensator (STATCOM), the Static Synchronous Series Compensator (SSSC), and the Unified Power Flow Controller (UPFC). In this paper, these FACTS controllers are derived in the current injection model, and it is applied to the linear and nonlinear analysis algorithm for power system dynamics studies. The parameters of the FACTS controllers are set to damp the inter-area oscillations, and the supplementary damping controllers and its control schemes are proposed to increase damping abilities of the FACTS controllers. For these works, the linear analysis for each FACTS controller with or without damping controller is executed, and the dynamic characteristics of each FACTS controller are analyzed. The results are verified by the nonlinear analysis using the time-domain simulation.

Simulation of Reactive Power Compensation in Grid-Connected Wind Power Generation System (계통연계 풍력발전시스템의 무효전력 보상에 대한 시뮬레이션)

  • Ro, Kyoung-Soo;Jang, Bo-Kyoung
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.6
    • /
    • pp.82-89
    • /
    • 2011
  • Reactive power support is considered to be necessary for dealing with a voltage stability issue with wind turbine system employing squirrel-cage induction generator(SCIG). This paper analyses steady-state characteristics of the SCIG wind turbine system by simulating torque-slip characteristics of SCIG with respect to variations of interconnecting network strength and generator terminal voltage. It also presents dynamics analysis of SCIG wind turbine system on Simulink to investigate the impact of static var compensator(SVC) and static synchronous compensator(STATCOM) on transient stability enhancement. It analysed transient stability with varying fault duration times and compared the transient stability characteristics with varying rated capacities of SVC and STATCOM. It is shown that the STATCOM has a better performance and reactive power support compared to SVC.

Firing Circuit analysis of Static Frequency Converter (SFC 시스템의 점호회로 분석)

  • Ryu, Ho-Seon;Shin, Mahn-Su;Kim, Chan-Ki;Lee, Joo-Hyun;Lim, Ick-Hun
    • Proceedings of the KIEE Conference
    • /
    • 2003.07b
    • /
    • pp.1220-1222
    • /
    • 2003
  • An analysis of thyristor firing and protection circuit applied to SFC(static Frequency Converter) is presented. This consists of firing circuit when thyristor is connected in series, one of overvoltage protection and monitor databack circuit of thyristor states etc. Also, each characteristic of foreign products was studied in this paper.

  • PDF

Control of Static Var Compensator Using A Cascade Typed Multilevel Voltage Source Inverter (멀티레벨 직렬 전압형 인버터를 이용한 무효전력보상기(SVC)의 제어)

  • Min, Wan-Ki;Park, Yong-Bae;Kim, Yeong-Han;Choi, Jae-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1996.11a
    • /
    • pp.332-335
    • /
    • 1996
  • Multilevel voltage source inverters are emerging as a new breed of power inverter options for high power applications. This paper presents a cascade typed multilevel voltage source inverter which has separate de sources for high voltage. This inverter is proposed for flexible ac transmission systems (FACTS) including static var compensator(SVC), series compensation and phase shifting. It can solve the problems of conventional transformer-based multipulse inverters and the problems of multilevel diode-clamped inverters. To show the superiority of multilevel cascaded inverter, simulation results are discussed in detail.

  • PDF

Instantaneous Active/Reactive Power Compensation of Distribution Static Compensator using State Observer (배전용 정지형 보상기의 상태관측기를 이용한 순시 유효/무효전력 보상)

  • Kim, Hyeong-Su;Choi, Jong-Woo
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.8
    • /
    • pp.1377-1382
    • /
    • 2008
  • DSTATCOM(distribution static compensator) is one of the custom power devices, and protects a distribution line from unbalanced and harmonic current caused by non-linear and unbalanced loads. Researches about DSTATCOM are mainly divided two parts, one is the calculation of compensation current and the other part is the current control. Conventional researches use a LPF(low pass filter) to eliminate ripple component at the calculation of compensation current. But this method has a problem that LPF's characteristics restrict the compensation performance of instantaneous active and reactive power. This paper proposes a calculation of compensation current using state observer that can be a counterproposal of conventional methods using LPF. Improved performance of instantaneous active and reactive power compensation was shown by experiments.

Simulation and Parameter Identification of Induction Machine in Load Modeling based on the Static Circuit Analysis (정태회로해석에 의한 전력부하로서의 유도전동기 시뮬레이션 및 파라메터 식별)

  • Lee, Bong-Yong;Shim, Keon-Bo;Ko, Tae-Kyu
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.370-374
    • /
    • 1991
  • This paper presents a static circuit model for static ant dynamic simulation of induction motors and identification of motor parameters. Instead of usual T-circuits, equivalent ${\pi}$-circuit has been proposed so that power Inputs into motor terminals can very easily calculated with very well known load flow method. It has been shown that, with wide range variation of applied voltage and frequency, successful static simulations can be performed and further the proposed static model can be used to simulate dynamic characteristics. Finally it is shown also that motor parameters can easily be identified based on the proposed static circuit.

  • PDF

Static equilibrium and linear vibration analysis of a high speed electric train system (고속전철 시스템의 정적평형 및 선형진동 해석)

  • 김종인;유홍희;황요하
    • Journal of the Korean Society for Railway
    • /
    • v.2 no.4
    • /
    • pp.1-8
    • /
    • 1999
  • A formulation to perform static equilibrium and linear vibration analysis is presented in this paper. The formulation employs minimum number of equations of motion which are derived by using a partial velocity matrix. The static equilibrium analysis is performed first, then the linear vibration analysis is performed at the static equilibrium position. By using the formulation presented in this paper, static equilibrium and linear vibration analysis of a high speed electric train system are performed. A single bogie system, a power car vehicle, and a train system which consists of five vehicles are analyzed, respectively. Natural frequencies and a few lowest mode shapes of the two are identified in this paper.

  • PDF

Complex Vector Modeling and Series Decoupling Current Control Strategy of High-Power L/LCL Type Grid-Connected Converter Under Low Switching Frequency

  • Wang, Yingjie;Jiao, Lanyi;Yang, Bo;Wang, Wenchao;Liu, Haiyuan
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1879-1888
    • /
    • 2018
  • With power level of grid-connected converters rising, the switching frequency of the switching devices is commonly greatly reduced to improve its power capacity. However, this results in serious couplings of the dq current components, which leads to degradation of the static and dynamic performances of grid-connected converters and fluctuations of the reactive power in dynamic processes. In this paper, complex vector models under low switching frequency are established for an L/LCL grid-connected converter, and the relationship between the switching frequency and the coupling degree is analyzed. In addition, a series decoupling current control strategy is put forward. It is shown that the proposed control strategy can eliminate the couplings, improve the performances and have good robustness to parameter variations through static and dynamic characteristics analyses and a sensitivity analysis. Experimental and simulation results also verify the correctness of the theoretical analyses and the superiority of the proposed control strategy.

Characterization of Fluorocarbon Thin Films deposited by PECVD (PECVD로 증착된 불화 유기박막의 특성 평가)

  • 김준성;김태곤;박진구;신형재
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.8 no.2
    • /
    • pp.31-36
    • /
    • 2001
  • Teflon-like fluorocarbon thin film was deposited by using difluoromethane$(CH_2F_2$) added with Ar, $O_2$, and $CH_4$ on Si, $SiO_2$, TEOS, and Al substrate. The deposited thin film was characterized by static contact angles for measuring hydrophobicity in various additive gas ratio. temperature, and working pressure. In case of addition with Ar, the static contact angles decreased as additive gas ratio and power increased. But the static contact angles increased as working pressure increased. Specially, super-hydrophobic surface was obtained using the powder-like fluorocarbon thin film above 2 Torr. Added with $O_2$, the static contact angles decreased as the $O_2$ ratio and working pressure increased. And the static contact angles did not change in 100W, but hydrophilic surface was obtained at 200W. In case of addition of CE$_4$, static contact angles dramatically increased in $CH_4/CH_2F_2$ ratio 5. And continuous static contact angles obtained above ratio 5. As compare with previous experiments by thermal evaporation, the fluorocarbon thin film by plasma polymerization was obtained very low hysteresis. This results shows more homogenous surface by plasma polymerization than thermal evaporation process.

  • PDF

Robust Active Power Control of a Battery-Supported DSTATCOM to Enhance Wind Generation Power Flow

  • Mahdianpoor, Mohammad;Kiyoumarsi, Arash;Ataei, Mohammad;Hooshmand, Rahmat-Allah
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1357-1368
    • /
    • 2017
  • The lack of controllability over the wind causes fluctuations in the output power of the wind generators (WGs) located at the wind farms. Distribution Static Compensator (DSTATCOM) equipped with Battery Energy Storage System (BESS) can significantly smooth these fluctuations by injecting or absorbing appropriate amount of active power, thus, controlling the power flow of WGs. But because of the component aging and thermal drift, its harmonic filter parameters vary, resulting in performance degradation. In this paper, Quantitative Feedback Theory (QFT) is used as a robust control scheme in order to deactivate the effects of filter parameters variations on the wind power generation power smoothing performance. The proposed robust control strategy of the DSTATCOM is successfully applied to a microgrid, including WGs. The simulation results obviously show that the proposed control technique can effectively smooth the fluctuations in the wind turbines' (WT) output power caused by wind speed variations; taking into account the filter parameters variations (structural parameter uncertainties).