• 제목/요약/키워드: Static load test

검색결과 997건 처리시간 0.032초

베트남 연약지반에서의 현장타설말뚝 설계 사례 (A Case Study on the Design of Drilled Shaft on Soft Ground in Vietnam)

  • 서원석;조성한;최기병
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.591-604
    • /
    • 2008
  • In this study, two design examples of drilled shafts on soft ground in Ho-Chi-Minh City, Vietnam are introduced. One is for a 27-story apartment and the other is for a Arch bridge over Saigon river. Unlikely the normal cases in Korea, all of the bored pile foundations are supposed to be placed on soil layers. Therefore, skin friction between pile and ground is the most crucial design parameter. Three methods using SPT N value of sandy soil -Korean Road Bridge Code(1996), Reese and Wright (1977), and O'Neill and Reese (1988)- were adopted to obtain an ultimate axial bearing capacity. In order to verify the calculated bearing capacity, 3 sets of static load test and a Osterberg Cell test were performed at an apartment site and a bridge site respectively. LRFD (Load Resistance Factored Design) method was compared with ASD (Allowable Stress Design) method. On application of ASD method, safety factor for skin friction was adopted as 2 or 3 while safety factor for end bearing was 3. The design bearing capacities from ASD method matched well with those from LRFD method when safety factor for skin friction was adopted as 2.

  • PDF

키트용 접이식 복합재 날개 개발 (A Development of Pivoting Composite Wing for Mounting Kit)

  • 주영식;전우철;변관화;조창민
    • 한국군사과학기술학회지
    • /
    • 제16권4호
    • /
    • pp.486-492
    • /
    • 2013
  • The pivoting composite wing is developed for the kit to be mounted on the external stores. The wing has a pivoting structure for the installation to an aircraft and high aspect ratio to increase lift drag ratio. The wing needs to be light and have sufficient strength and stiffness to satisfy structural design requirements. The wing is designed with carbon fiber composite and the structural parts are integrated to reduce cost to manufacture. In order to verify the structural performances, the design load analysis and flight load survey, the static analysis and test, the ground vibration test and flutter analysis are performed. It is shown that the wing has sufficient structural strength and stiffness to satisfy the structural design requirements.

대차틀의 구조해석 및 하중시험에 관한 연구 (Structure Analysis and Loading Test of Bogie Frame)

  • 윤성철;박성혁;이강원;김원경;홍용기
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 춘계학술대회 논문집
    • /
    • pp.199-205
    • /
    • 2004
  • This paper describes the result of structure analysis and load test of bogie frame. The purpose of the analysis and test is to evaluate an safety which bogie frame shall be considered fully sufficient rigidity so as to satisfy proper system function under maximum load. Bogie system consist of bogie frame, suspensions, wheel-sets, brake system and transmission system. Among these component, the bogie frame is most significant component subjected to the vehicle and passenger loads. The evaluation method is used the JIS E 4207 specification throughout the FEM analysis and static load test. The test results have been very safety and stable for design load conditions.

  • PDF

판토그라프 접촉력 측정을 위한 스트레인 게이지 내장형 센서 개발 (Development of Load Cell to Measure Contact Force of Pantograph)

  • 박찬경;백진성;김영국;김기환
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.947-953
    • /
    • 2010
  • The KTX-Sancheon has been commercially operating on the high-speed line since March. 2. In order to verify the performance of high-speed train and core equipments such as current collection system, sophisticated tests and evaluating procedures should have been considering. In this paper, the load cell with a built-in strain-gauge which developed to improve measuring method of contact force between the pantograph and catenary system is introduced. The static test results of the load cell shows that its design is very suitable and applicable for the dynamic test and on-line test. After the test and evaluation of load cell's dynamic calibration with pantograph, we will be applied to test interaction characteristics between the pantograph and catenary system on the high-speed line.

  • PDF

하중시험에 의한 대차의 강도 평가 (Strength Evaluation of Bogie by Loading Test)

  • 윤성철;권성태;김명룡;이강원
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2004년도 추계학술대회 논문집
    • /
    • pp.622-627
    • /
    • 2004
  • This paper describes the result of load test of bogie frame. The purpose of test is to evaluate an safety which bogie frame shall be considered fully sufficient rigidity so as to satisfy proper system function under maximum load. Bogie system consist of bogie frame, suspensions, wheel-sets, brake system and transmission system. Among these component, the bogie frame is the most significant component subjected to the vehicle and passenger loads. The evaluation method is used the JIS E 4207 specification throughout the static load test. The test results have been very safety and stable for design load conditions.

  • PDF

강합성교각의 내진성능평가 Part II: 유사동적실험 및 잔류내진성능 평가 (Seismic Performance of Concrete-Filled Steel Piers Part II: Pseudo-Dynamic Test and Residual Seismic Capacity)

  • 조창빈;서진환;장승필
    • 한국지진공학회논문집
    • /
    • 제6권2호
    • /
    • pp.21-28
    • /
    • 2002
  • Ductile behavior and strength of concrete-filled steel(CFS) piers was supported by many quasi-static cyclic loading tests. This test method, however, only estimates the member′s deformation capacity under escalating and repetitive displacement and ignores dynamic and random aspects of an earthquake load. Therefore, to understand complete seismic behavior of the structure against an earthquake, dynamic tests such as shaking table test and pseudo-dynamic tests are required as well as quasi-static tests. In this paper, following "Seismic Performance of Concrete-Filled Steel Piers Part I : Quasi-Static Cyclic Loadint Test", the seismic behavior of CFS and steel piers designed for I-Soo overpass in Seoul in investigated by the pseudo-dynamic test. In addition, the residual strength of both piers after an earthquake is estimated by the quasi-static test. The results show that both piers have satisfactory ductility and strength against well-known EI Centro earthquake although the CFS pier has better strength and energy dissipation than the steel pier.

고칼슘 연소재를 이용한 매입말뚝 주면고정액의 현장 재하시험을 통한 성능평가 (Performance Evaluation of Pile-Filling Material Using High Calcium Ash by Field Loading Test)

  • 서세관;김유성;임양현;조대성
    • 한국지반공학회논문집
    • /
    • 제34권6호
    • /
    • pp.17-24
    • /
    • 2018
  • 순환 유동층 보일러의 연소재를 고로슬래그의 알칼리 활성화 반응 자극제로 활용하여 개발한 새로운 매입말뚝의 주면고정액(ZA-Soil)을 시멘트밀크 공법의 주면고정액으로 사용한 말뚝에 대하여 정재하시험 및 동재하시험을 실시하여 보통 포틀랜드시멘트(OPC)와 비교하여 성능을 평가하였다. 정재하시험을 수행한 결과 말뚝의 허용하중은 1,350kN로 보통 포틀랜드시멘트를 매입말뚝의 주면고정액으로 사용한 결과와 동일하였고, 전 침하량은 6.97mm, 순 침하량은 1.48mm로 보통 포틀랜트시멘트의 전 침하량 7.825mm, 순 침하량 2.005mm와 유사한 결과를 보이는 것으로 나타났다. 동재하시험 및 CAPWAP분석을 실시한 결과, 새로운 매입말뚝의 주면고정액(ZA-Soil)의 주면 마찰력은 375.0kN, 선단 지지력은 3,045.9kN, 허용지지력은 1,368.36kN으로 나타났고, 포틀랜드시멘트를 매입말뚝의 주면고정액으로 사용한 결과와 유사한 결과를 보이는 것으로 나타났다.

대구경 현장타설말뚝의 지지력 측정 사례연구 (A Case Study on the Measurement and Estimation of Bearing Capacity of Large Diameter Bored Pile)

  • 이원제;정훈준;이우진;장기수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2000년도 가을 학술발표회 논문집
    • /
    • pp.285-292
    • /
    • 2000
  • Though there has been increasing use of large diameter drilled shaft as a foundation structure of bridges, current practice for quality control is to confirm the minimum required load carrying capacity during construction stage. For economic and appropriate design of drilled shaft, it is necessary to evaluate the load transfer mechanism by pile load tests during initial stage of construction and to use the test results as a feedback to a revision of initial design. In this paper, results of load tests peformed at several domestic sites are presented to investigate the load transfer characteristics of large diameter drilled shaft. It was found that most of the load on piles is sustained by shaft friction and that only small portion of the load reaches the bottom of the drilled shaft. Some test results of drilled shaft by Pile Driving Analyzer performed at same sites are also presented to compare the load transfer characteristics interpreted from static pile load tests.

  • PDF

샌드위치 복합재 구조의 손상에 의한 잔류 강도 연구 (A Study on Residual Strength of Damaged Sandwich Composite Structure)

  • 공창덕;박현범;김상훈;송민수
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.2073-2079
    • /
    • 2008
  • This study aims to investigate the residual strength of sandwich composites with Al honeycomb core and carbon fiber face sheets after the quasi-static indentation damage by the experimental investigation. The 3-point bending test and the edge-wise compressive strength test were used to find the mechanical properties. The quasi-static point load and damaged hole was applied to introduce the simulated damage on the Each damaged specimens were finally assessed by the 3-point bending test and the compressive strength test. The investigation results revealed the residual strength of the damaged specimens due to the quasi-static indentation.

  • PDF

유리섬유 복합재를 이용한 RC슬래브 교량의 보강성능평가 (Reinforced Performance Evaluation of RC Slab Bridge Using Conclinic Advanced FiberWrep)

  • 박순응;박문호;이택우
    • 한국방재학회 논문집
    • /
    • 제10권5호
    • /
    • pp.35-40
    • /
    • 2010
  • 본 연구에서는 RC슬래브 교량의 내하력을 향상시키기 위해 유리섬유 복합재(CAF)를 이용한 보강방법을 제시하였다. 보강 성능을 평가하기 위해 설계하중 DB 18로 설계된 실험대상 교량의 슬래브 하면에 단위폭당 50 cm로 CAF 복합재를 보강하여 정 동적재하시험을 수행하였다. 정 동적재하시험 결과 RC슬래브의 최대변위, 변형률, 충격계수는 보강전에 비하여 보강후에 각 14.7%, 5.0% 및 33.7% 감소하였다. 시험경간 중앙부에서의 RC슬래브의 공칭저항비는 27% 증가하였고, 공용내하력은 1,2 경간에서 44.6%, 48.9%증가하였다. 결론적으로 설계하중 DB 18로 설계된 노후된 RC슬래브 교량을 현행 1등급교의 설계하중 DB 24로 향상시키는데 CAF 복합재를 이용한 보강방법은 매우 효과적인 것으로 판단된다.