• 제목/요약/키워드: Static electric field

검색결과 98건 처리시간 0.019초

공진형 무선전력전송 대역의 100kHz~10MHz 자기장에 의한 인체유도전류계산과 전자기장 인체보호기준 분석 (Calculation of Induced Current in the Human Body by Magnetic Field in the 100kHz~10MHz Resonant WPT Frequency Range and Analysis of EMF Guideline)

  • 신한수;송혜진;변진규
    • 조명전기설비학회논문지
    • /
    • 제27권2호
    • /
    • pp.110-119
    • /
    • 2013
  • As the technologies such as middle-range resonant WPT (wireless power transfer) advance that utilizes medium and low-frequency magnetic field, the importance of safety of such magnetic field is growing. The research on the effect of electromagnetic field on the human body has been mainly done on the GHz range of mobile phones, or 50~60Hz range of electric power systems. However, there has been relatively few works on the 100kHz~10MHz range used in the resonant wireless power transfer. Since there is a difference in the limiting value of magnetic field between widely used ICNIRP EMF guideline and IEEE C95.1 standard, there can be possible confusion when establishing EMF (Electromagnetic Field) standard on the wireless power transfer device in the future. In this paper, the induced current in the human body, which is the basic restriction of the EMF guideline, is calculated using Quasi-static FDTD method when 3D high-resolution human model is exposed to the 100kHz~10MHz magnetic field. Using this result, the feasibility of the magnetic field reference level in the ICNIRP guideline is analyzed.

전자정보기기 구동용 영구자석형 스테핑 모터의 3차원 해석 (3-Dimensional Analysis of Permanent Magnet Stepping Motor With Claw Poles)

  • 안지현;박승찬;류세현;정인성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.107-109
    • /
    • 2004
  • Stepping motors are widely used for various electric instruments. In case of analysing claw pole PM slopping motor 3-dimensional analysis is necessary for accurate field calculation. This paper presents static torque characteristics of a permanent magnet type stepping motor with claw poles using three-dimensional finite element analysis.

  • PDF

Static stability analysis of smart nonlocal thermo-piezo-magnetic plates via a quasi-3D formulation

  • Fenjan, Raad M.;Ahmed, Ridha A.;Faleh, Nadhim M.;Hani, Fatima Masood
    • Smart Structures and Systems
    • /
    • 제26권1호
    • /
    • pp.77-87
    • /
    • 2020
  • By employing a quasi-3D plate formulation, the present research studies static stability of magneto-electro-thermo-elastic functional grading (METE-FG) nano-sized plates. Accordingly, influences of shear deformations as well as thickness stretching have been incorporated. The gradation of piezo-magnetic and elastic properties of the nano-sized plate have been described based on power-law functions. The size-dependent formulation for the nano-sized plate is provided in the context of nonlocal elasticity theory. The governing equations are established with the usage of Hamilton's rule and then analytically solved for diverse magnetic-electric intensities. Obtained findings demonstrate that buckling behavior of considered nanoplate relies on the variation of material exponent, electro-magnetic field, nonlocal coefficient and boundary conditions.

Assessment of multi-physical field effects on nonlinear static stability behavior of nanoshells based on a numerical approach

  • Zhanlei Wang;Ye Chen
    • Steel and Composite Structures
    • /
    • 제46권4호
    • /
    • pp.513-523
    • /
    • 2023
  • Buckling and post-buckling behaviors of geometrically perfect double-curvature shells made from smart composites have been investigated. The shell has been supposed to be exposed to transverse mechanical loading and magneto-electro-elastic (MEE) coupling. The composite shell has been made of two constituents which are piezoelectric and magnetic ingredients. Thus, the elastic properties might be variable based upon the percentages of the constituents. Incorporating small scale impacts in regard to nonlocal theory leads to the establishment of the governing equations for the double-curvature nanoshell. Such nanoshell stability will be shown to be affected by composite ingredients. More focus has been paid to the effects of small scale factor, electric voltage and magnetic intensity on stability curves of the nanoshell.

Electromagnetothermoelastic behavior of a rotating imperfect hybrid functionally graded hollow cylinder

  • Saadatfar, M.;Aghaie-Khafri, M.
    • Smart Structures and Systems
    • /
    • 제15권6호
    • /
    • pp.1411-1437
    • /
    • 2015
  • The electro-magneto- thermo-elastic behavior of a rotating functionally graded long hollow cylinder with functionally graded piezoelectric (FGPM) layers is analytically analyzed. The layers are imperfectly bonded to its inner and outer surfaces. The hybrid cylinder is placed in a constant magnetic field subjected to a thermo-electro-mechanical loading and could be rested on a Winkler-type elastic foundation. The material properties of the FGM cylinder and radially polarized FGPM layers are assumed to be graded in the radial direction according to the power law. The hybrid cylinder is rotating about its axis at a constant angular velocity. The governing equations are solved analytically and then stresses, displacement and electric potential distribution are calculated. Numerical examples are given to illustrate the effects of material in-homogeneity, magnetic field, elastic foundation, applied voltage, imperfect interface and thermo-mechanical boundary condition on the static behavior of a FG smart cylinder.

Time-Resolved Infrared Spectroscopy of Molecular Reorientation During FLC Electro-Optic Switching

  • Jang, Won-Gun;Clark, Noel A.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.1112-1117
    • /
    • 2003
  • Polarized Fourier transform infrared (IR) absorption is used to probe molecular conformation in a ferroelectric liquid crystal (FLC) during the reorientation induced by the external field. Spectra of planar aligned cells of FLC W314 are measured as functions of IR polarizer orientation and electric field applied to the FLC. The time evolution of the dichroism of the absorbance due to biphenyl core and alkyl tail molecular vibration modes, is observed. Static IR dichroism experiments show a W314 dichroism structure in which the principal axis of dielectric tensor from molecular core vibration are tilted further from the smectic layer normal than those of the tail. This structure indicates the effective binding site in which the molecules are confined in the Sm-C phase has, on average, "zig-zag" shape and this zig-zag binding site structure is rigidly maintained while the molecular axis rotates about the layer normal during field-induced switching.

  • PDF

반도성 고분자 현탁액의 전기유변학적 거동과 계면편극화 (Electrorheological Behaviors and Interfacial Polarization of Semi-conductive Polymer-based Suspensions)

  • B.D Chin;Lee, Y.S.;Lee, H.J.;S.M. Yang;Park, O.O.
    • 유변학
    • /
    • 제10권4호
    • /
    • pp.195-201
    • /
    • 1998
  • 반도성 고분자인 폴리아닐린과 폴리파라페닐렌을 이용한 전기유변유체의 유변학적 및 전기적 특성을 고찰하였다. 이들 반도성 고분자 현탁액은 분산입자와 현탁매질의 전기전도도 차이로 인하여 직류 전기장 하에서 큰 점도 증가를 보였다. 전기유변효과로 기인한 동적 항복응력은 낮은 전기장 하에서는 전기장 제곱에의 의존성을 보였으나 높은 전기장 하에서는 전기장의 1승에 비례하는 거동을 나타내었다. 항복 응력은 분산입자의 전기전도도가 증가함에 따라 최대값을 보이다가 다시 감소하는 현상을 나타내었다. 직류 전기장 하에서의 이러한 항복 응력 거동은 전도도 효과에 의한 맥스웰-와그너 계면편극화로 설명되는 현탁액의 유전 특성과 관련됨을 발견하였다. 계면 편극화 효과가 전기유변현상에 미치는 영향에 대한 더 깊은 이해와 분산액의 침강 안정성 개선을 위하여, 전기유변 효과의 조절이 가능할 뿐 아니라 현탁액의 콜로이드 안정성을 향상시킬 수 있는 여러 가지의 계면 활성제의 영향을 피력하였다.

  • PDF

선체 교류 전자장 제거를 위한 능동 축 접지 시스템 설계 (Design of an Active Shaft Grounding System for the Elimination of Alternating Electromagnetic Field in Vessel)

  • 김태규;안호균;윤태성;박승규;곽군평
    • 한국정보통신학회논문지
    • /
    • 제19권6호
    • /
    • pp.1515-1524
    • /
    • 2015
  • 최근 선박의 부식을 방지할 목적으로 전기적인 방식 장치를 이용하여 선체와 프로펠러의 부식을 방지하는 장치가 많이 이용되고 있는 추세이다. 그러나 전기적 방식 방법은 선체 내부의 전원장치에 의해 선체 주위의 해수로 전류를 방사하여 선체와 프로펠러가 부식이 되지 않는 상태로 인위적으로 만들어 주는 방법을 사용하는데, 해수에 방사되는 방식전류로 인하여 선체 외부에서 전자장 신호가 발생하게 된다. 본 논문에서는 선체 외부의 수중에서 발생하는 전자장 신호를 분석하고, 이에 대한 감소 대책에 대한 연구를 수행하는 것을 목표로 하였다. 기존의 축 접지 시스템에서는 축 전위가 100[mV] 이상 이며, 교류 전류 성분이 전체의 10% 이상을 차지하였으나, 본 논문에서는 방식전류내에서 교류전자장을 발생하는 교류 전류 성분과 축 전위가 각각 1% 와 2[mV]이내로 유지되게 하는 제어 시스템을 설계하고, 모의 실험을 통하여 그 성능을 입증하였다.

Individual DC Voltage Balancing Method at Zero Current Mode for Cascaded H-bridge Based Static Synchronous Compensator

  • Yang, Zezhou;Sun, Jianjun;Li, Shangsheng;Liao, Zhiqiang;Zha, Xiaoming
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.240-249
    • /
    • 2018
  • Individual DC voltage balance problem is an inherent issue for cascaded H-bridge (CHB) based converter. When the CHB-based static synchronous compensator (STATCOM) is operating at zero current mode, the software-based individual DC voltage balancing control techniques may not work because of the infinitesimal output current. However, the different power losses of each cell would lead to the individual DC voltages unbalance. The uneven power losses on the local supplied cell-controllers (including the control circuit and drive circuit) would especially cause the divergence of individual DC voltages, due to their characteristic as constant power loads. To solve this problem, this paper proposes an adaptive voltage balancing module which is designed in the cell-controller board with small size and low cost circuits. It is controlled to make the power loss of the cell a constant resistance load, thus the DC voltages are balanced in zero current mode. Field test in a 10kV STATCOM confirms the performance of the proposed method.

EMTDC를 이용한 DSTATCON 설치 효과 분석 (Analysis of System Performance on DSTATCON Installation using EMTDC)

  • 유일도;최영준;홍순옥;이학성;전영수;이기선
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.943-945
    • /
    • 1998
  • This paper presents a method of modeling of DSTATCON (Distribution-line Static Condenser) for installation in a specific plant and analyze the effectiveness of the DSTATCON from the viewpoints of voltage regulation and harmonic mitigation in a distribution line. For the reliable modeling, detailed information on distribution system and loads is performed by field measurements. The DSTATCON has been modeled according to the control algorithm of real controller. The effectiveness of the DSTATCON installation is verified by simulation using EMTDC.

  • PDF