• 제목/요약/키워드: Statcom

검색결과 231건 처리시간 0.044초

전력계통의 정태해석에 미치는 STATCOM과 UPFC의 영향에 대한 비교 연구 (A Comparative Study on the Effect of STATCOM and UPFC in the Static Analysis of Power Systems)

  • 김덕영;이지열;국경수;노대석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.214-216
    • /
    • 2000
  • This paper presents an comparative study on the effect of STATCOM and UPFC to the power system static analysis. The effect of STATCOM can be analyzed with PSS/E program which is generally used in power system analysis, while UPFC model for static analysis is not provided yet. Thus, UPFC is equivalently represented as a synchronous condenser and load, while the active and reactive power of the specific transmission line and the voltage of the bus is controlled appropriately. This procedure is implemented by IPLAN which is an external macro program of PSS/E. The simulation results show that UPFC is more effective to control the bus voltage than STATCOM, because UPFC can control not only the bus voltage where the parallel inverter is installed but also the active and reactive power flow in the transmission line where the series inverter is installed.

  • PDF

제주 50MVA STATCOM 설치 효과 분석 (Installation of 50MVA STATCOMs in Jeju Power System)

  • 한영성;정정주;박정수;여상민;송지영;서인영
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2010년도 하계학술대회 논문집
    • /
    • pp.328-329
    • /
    • 2010
  • STATCOM은 전력전자 기반의 전압형 인버터를 이용한 무효 전력 보상장치로써 우수한 전압 제어 능력과 빠른 동작 특성, 그리고 운용 및 유지/관리의 유연성으로 인해 기존에 사용되던 무효 전력 보상장치들을 빠르게 대체하고 있다. 효성중공업에서는 국내 최초로 100MVA STATCOM을 개발하여 한전 실 계통에 설치/운용한 바 있고 이 경험을 바탕으로 최근 논의되고 있는 제주 50MVA STATCOM의 개발에 착수하였다. 본 논문에서는 이 프로젝트와 관련된 배경을 설명하고 연구 과정 중에 수행된 제주 전력 계통의 STATCOM 설치 효과 모의 결과에 대해서 소개하고자 한다.

  • PDF

송전용 무효전력보상기의 제어시스템 설계와 성능해석 (Control System Design and Performance Analysis for Transmission Static Compensator)

  • 한병문;최대길
    • 전력전자학회논문지
    • /
    • 제3권1호
    • /
    • pp.77-84
    • /
    • 1998
  • 본 논문에서는 비선형상태피드백을 적용한 무효전력보상기의 제어시스템을 설계하여 시뮬레이션과 축소모형 실험에 의한 성능해석에 관해 기술하였다. 무효전력 보상기의 수리모형을 3상 등가회로와 대표적인 동작점에 대한 상태방정식을 이용하여 도출하였으며, 비선형 상태피드백을 고려한 무효전력 보상기의 동특성을 표현하는 전달함수를 유도하였다. 또한 근궤적을 이용한 시스템 안정도 해석을 실시하여 제어시스템 설계를 실시하였다. 고안된 제어시스템의 성능해석은 EMTP를 이용한 시뮬레이션과 축소모형 실험을 통해 검증하였는데, 검증결과 고안된 제어시스템은 송전계통의 무효전력보상에 우수한 성능을 갖음이 확인되었다.

STATCOM에서 영상분 전류주입에 의한 셀간 전압평형화 제어의 향상 (Enhancement of Cell Voltage Balancing Control by Zero Sequence Current Injection in a Cascaded H-Bridge STATCOM)

  • 권병기;정승기;김태형
    • 전력전자학회논문지
    • /
    • 제20권4호
    • /
    • pp.321-329
    • /
    • 2015
  • The static synchronous compensator (STATCOM) of cascaded H-bridge configuration accompanying multiple separate DC sides is inherently subject to the problem of uneven DC voltages. These DC voltages in one leg can be controlled by adjusting the AC-side output voltage of each cell inverter, which is proportional to the active power. However, when the phase current is extremely small, large AC-side voltage is required to generate the active power to balance the cell voltages. In this study, an alternative zero-sequence current injection method is proposed, which facilitates effective cell balancing controllers at no load, and has no effect on the power grid because the injected zero sequence current only flows within the STATCOM delta circuit. The performance of the proposed method is verified through simulation and experiments.

고전압 무효전력 보상기를 사용한 대규모 풍력발전 설비의 전력 품질 보상 (Control of Power Quality Using a High Voltage STATCOM for the Integration of Large Scale Wind Power Plant)

  • 김지홍;송승호;정승기
    • 신재생에너지
    • /
    • 제8권4호
    • /
    • pp.13-20
    • /
    • 2012
  • This paper describes a transformerless static synchronous campensator (STATCOM) system based on cascade H-bridge multilevel inverter with star configuration. It is designed not only for the dynamic and continuous compensation of the reactive power but also for the improvement of power quality of existing wind power plant. Especially, when the induction generator of wind turbine is directly connected to the grid, reactive power are occurred by exiting current. so a reactive power compensation system based on the cascade H-bridge multilevel STATCOM is proposed because the output power quality and controllability of reactive power are required by grid code in many different countries. Using various The proposed reactive power control strategy using a STATCOM is compared with the conventional scheme using fixed-size of capacitor bank through various simulation results.

제주계통의 무효전력보상을 위한 SVC와 STATCOM의 운전특성 비교 (The Comparison of Operating Characteristics of SVC and STATCOM for Compensating the Reactive Power in the Jeju Power System)

  • 이승민;김일환;김호민;오성보;이도헌
    • 한국태양에너지학회 논문집
    • /
    • 제35권3호
    • /
    • pp.49-56
    • /
    • 2015
  • This paper presents a comparative operating characteristics of static var compensator(SVC) and static synchronous compensator(STATCOM) for compensating the reactive power in the Jeju power system. There are two kinds of reactive power compensating systems, which are active and passive system in the applications of the line commutated converter type high voltage direct current (LCC-HVDC). In the Jeju power system, two STATCOMs as active compensating system have been operating. Even though STATCOM has good performance compared with SVC, economical efficiency of former system is not good to the latter system. So, it is necessary to examine the performance and economical efficiency depend on the intention before appling the system. To compare the operating characteristics of two systems in the Jeju power system, simulations have been carried out for case studies that both of the HVDC system have transient state by using PSCAD/EMTDC program.

Dynamic Coordination Strategies between HVDC and STATCOM

  • Kim, Chan-Ki;Sood, Vijay;Lee, Seok-Jin
    • Journal of Power Electronics
    • /
    • 제9권6호
    • /
    • pp.892-902
    • /
    • 2009
  • This paper deals with the dynamic voltage control problem at the inverter end of a HVDC link when connected to a weak AC system which has the potential for harmonic instability and commutation failures. The dynamic voltage control problem is tackled with a STATCOM (Static Compensator), which not only provides a rapid recovery from harmonic instability and commutation failures but also offers a lower cost filter design for HVDC systems. PSCAD/EMTDC simulations are presented to validate the proposed topology and to demonstrate its robust performance.

STATCOM 시스템에 대한 강인 PI 제어기 설계 및 안정성 분석 (Robust PI controller and stability analysis for STATCOM system)

  • 강현재;한영성;이영옥;정정주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.254_255
    • /
    • 2009
  • 본 논문에서는 비선형 특성의 STATCOM 시스템에 대해 강인한 PI 제어기를 설계하였다. 설계된 PI 제어기는 불확실성 변수에 대해 모든 동작 점에서 항상 안정하다는 것을 보드선도, 게인, 위상 여유, Nyquist 선도를 통해 검증하였다.

  • PDF

불평형 부하를 가지는 Cascaded H-bridge Multilevel STATCOM에서 전압불평형 보상기의 설계 (Design of Voltage Unbalance Compensator in Cascaded H-bridge Multilevel STATCOM with Unbalanced Load)

  • 김태형;권병기;정승기
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 전력전자학술대회 논문집
    • /
    • pp.128-129
    • /
    • 2013
  • 본 논문에서는 전기로 부하에서 발생하는 무효전력 성분과 역상분 전류를 보상하기 위한 STATCOM(STATic synchronous COMpensator)을 Cascaded Multilevel Converter(CMC)로 구성하는 경우 역상분 전류 보상시에 발생하는 직류전압의 불평형을 보상하기 위한 방법을 제안하고, 이를 시뮬레이터를 통해 검증하였다.

  • PDF

MMC STATCOM의 Valve 제작 및 시험 (Manufacturing and Performance Test of Valve for MMC STATCOM)

  • 이두영;박용희;정종규;김준성
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2015년도 전력전자학술대회 논문집
    • /
    • pp.510-511
    • /
    • 2015
  • MMC(Modular Multilevel Converter)형 STATCOM 개발을 위해서는 시스템을 이루는 핵심 구성 요소인 Valve의 설계 및 신뢰성 검증이 매우 중요하다. Valve란 다수의 Sub-module을 직렬로 연결, 조합한 것이며 시스템의 용량에 따라 모듈의 직렬 개수가 정해진다. 그러므로 Valve의 최적 설계 및 제어가 시스템의 성능을 개선할 수 있는 주요 항목으로 작용한다. 본 논문에서는 이러한 Valve를 제작한 내용과 시험 설비를 통해 수행된 제품의 운전 특성에 대해서 기술하였다.

  • PDF