• Title/Summary/Keyword: Startup/shutdown

Search Result 35, Processing Time 0.019 seconds

A Three-Dimensional Operational Transient Simulation of the CANDU Core with Typical Reactor Regulating System

  • Yeom, Choong-Sub;Kim, Hyun-Dae;Park, Kyung-Seok;Park, Jong-Woon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.500-505
    • /
    • 1995
  • This paper describes the results of simulation of a CANDU operational transient problem (re-startup after short shutdown) using the Coupled Reactor Kinetics(CRKIN) code developed previously with CANDU Reactor Regulating System(RRS) logic. The performance in the simulation is focused on investigating the behaviours of neutron power and regulating devices in accordance with the changes of xenon concentration following the operation of the RRS.

  • PDF

Dynamic Characteristics and Experimental Study on the Foil Bearings for High Speed Turbo Machineries (고속 터어보기계용 공기포일베어링에 대한 동특성과 실험적 연구)

  • Hwang, Pyung;Kwon, Sung-In
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1998.04a
    • /
    • pp.159-166
    • /
    • 1998
  • 본 연구에서는 공기포일 베어링으로 지지된 로터 베어링 시스템을 구성하고 실험을 수행함으로써 시스템의 진동을 측정하고 그 결과를 해석함으로써 로터 베어링 시스템의 안정성 검토한다. 또, 초기 구동 마찰을 고려하여 공기윤활로만 구동되는 경우와 초기에 베어링 표면에 오일이 도포된 경우를 비교한다. Transient data를 해석 함으로써 로터 베어링 시스템의 startup 및 shutdown에 대한 특성 파악이 가능해지며 시스템의 동적 특성에 대한 더욱 정확한 해석을 가능케한다.

  • PDF

The analysis of dynamic behavior for horizontal drum type HRSG (Horizontal drum type HRSG(Heat Recovery Steam Generator)의 동특성 해석)

  • Lee, Chi-Hwan;Kim, Sung-Ho;Kim, Jong-Hyun
    • Proceedings of the KSME Conference
    • /
    • 2000.11b
    • /
    • pp.645-650
    • /
    • 2000
  • This dynamic analysis is performed about shutdown, load controlled and temperature controlled startup operating characteristics of the Horizontal drum type HRSG. This analysis was performed by constructing a dynamic model of the plant and running it through the appropriate.

  • PDF

Effect of Operating Conditions on Cold Startup of PEMFC Stack (운전조건에 따른 PEMFC 스택 냉시동 특성 연구)

  • Ko, Jae-Jun;Lee, Jong-Hyun;Kim, Sae-Hoon;Ahn, Byung-Ki;Lim, Tae-Won
    • Journal of Hydrogen and New Energy
    • /
    • v.20 no.3
    • /
    • pp.224-231
    • /
    • 2009
  • The improvement of cold start capability is one of the most challenging tasks to be solved for commercialization of fuel cell vehicle. In this study, cold start test and ice blocking test(IBT) of fuel cell stack were carried out under various operating conditions. This fuel cell stack can be thawed from -20$^{\circ}$C within 25s and the voltage change was found to be comprised of 4 steps; the first step is the voltage decrease by overpotential, the second step is the voltage increase by the cell temperature increase, the third step is the voltage decrease by ice blocking, and the last step is the voltage increase by thawing. Bootstrap startup was failed after shutdown at temperature under 40$^{\circ}$C because of much condensed water in the fuel cell. Quantitative estimation of cold start capability have been demonstrated by ice blocking test(IBT). In the results, it was found that cold start capability was improved double every 10$^{\circ}$C from 30$^{\circ}$C to 65$^{\circ}$C and enhanced by 30% at the condition of SR 3/4 compared to SR 1.5/2.0 and enhanced by 20% with dry purge condition compared to with RH 50% purge condition.

Transient soil-structure interaction with consistent description of radiation damping

  • Zulkifli, Ediansjah;Ruge, Peter
    • Structural Engineering and Mechanics
    • /
    • v.33 no.1
    • /
    • pp.47-66
    • /
    • 2009
  • Radiation damping due to wave propagation in unbounded domains may cause a significant reduction of structural vibrations when excited near resonance. Here a novel matrix-valued algebraic Pad$\acute{e}$-like stiffness formulation in the frequency-domain and a corresponding state equation in the time domain are elaborated for a soil-structure interaction problem with a layered soil excited in a transient manner by a flexible rotor during startup and shutdown. The contribution of radiation damping caused by a soil-layer upon a rigid bedrock is characterized by the corresponding amount of critical damping as it is used in structural dynamics.

Study on the Dynamic Simulation for an Integrated Coal Gasification Combined Cycle (석탄 IGCC 다이내믹 시뮬레이션에 관한 연구)

  • Joo, Yongjin;Kim, Simoon;Lee, Minchul;Kim, Miyeong
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.06a
    • /
    • pp.106.2-106.2
    • /
    • 2010
  • IGCC (Integrated Gasification Combined Cycle) plants are among the most advanced and effective systems for electric energy generation. From a control perspective, IGCC plants represent a significant challenge: complex reactions, highly integrated control to simultaneously satisfy production, controllability, operability and environmental objectives. While all these requirements seem clearly to demand a multivatiable, model predictive approach, not many applications can be easily found in the literature. This paper describes the IGCC dynamic simulation that is capable of simulating plant startup, shutdown, normal, and abnormal operation and engineering studies. This high fidelity dynamic models contain the detailed process design data to produce realistic responses to process operation and upset. And the simulation is used by engineers to evaluate the transient performance and produce graphical information indicating the response of the process under study conditions.

  • PDF

Development of PLC modules for the safety verification of chemical processes (공정의 안전 검증을 위한 PLC 모듈 개발)

  • Jeong, Sang-Hun;Lee, Kwang-Soon;Moon, Il
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.2 no.1
    • /
    • pp.53-59
    • /
    • 1996
  • An automatic verification method has been studied to determine the safety and operability of programmable logic controller (PLC) based systems. For the systematic and efficient verification, we have developed a conversion method from relay ladder logic (RLL) to the verification system description. RLL is a common representation used to document PLC programs for the sequential logic of the system such as the safety interlocks and the startup/shutdown procedures. Once the modules are developed, complex RLLs can be represented by the combination of modules. As a result we can verify complex PLC systems using the verification method including RLL modules. The developed modules are used to verify alarm systems and show that the method is valid.

  • PDF

Dynamic Characteristics and Experimental Study on the Foil Bearings for High Speed Turbo Machinery (고속 터어보기계용 공기포일베어링에 대한 동특성 해석과 실험적 연구)

  • Hwang, Pyung;Kwon, Sung-In
    • Tribology and Lubricants
    • /
    • v.14 no.4
    • /
    • pp.64-71
    • /
    • 1998
  • In this study deals with measurement of the vibration amplitudes of rotor-bearing system supported by foil bearing were performed experimentally, and the stability of the system were analyzed by using those results. Considering initial operating friction, compare bearing lubricated with only air and bearing surface lubricated with oil. Analyzing the transient data, the understanding of the characteristics fur startup and shutdown of rotor-bearing system are available and the dynamic characteristics of the system also can be analyzed exactly.

Verification of Hybrid Real Time HVDC Simulator in Cheju-Haenam HVDC System

  • Yang Byeong-Mo;Kim Chan-Ki;Jung Gil-Jo;Moon Young-Hyun
    • Journal of Electrical Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.23-27
    • /
    • 2006
  • In this paper a Hybrid Real Time HVDC Simulator fur both operator Training and Researching in the Cheju-Haenam HVDC System is proposed and its performance is studied by means of RTDS (Real Time Digital Simulator), EMTDC (Electro-Magnetic Transients system for DC), PSS/E (Power System Simulator for Engineering), and experienced scenarios. The objective of this paper is to represent the strategy in development for KEPCO's hybrid HVDC simulator for the Cheju-Haenam HVDC system. This simulator consists of two DC stations, DC cables, external digital/analog controllers, monitoring systems and control desk for education, and AC networks. Its suitability for operator's education is tested during startup/shutdown and normal state operations. Dynamic performances of it are also verified.

An Optimum Design of Herringbone Grooved Journal Bearings for Spindle Motor of Hard Disk Drive System (HDD 스핀들용 빗살무늬 저널베어링의 최적설계)

  • ;Y. Muraki;M. Tanaka
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.530-532
    • /
    • 2002
  • This paper presents an optimum design of herringbone grooved journal bearing for spindle motor of hard disk drive (HDD) system. In addition to the conventional “rectangular” groove, various groove profiles are designed. The stiffness and damping coefficients of the oil film and frictional torque are calculated and compared for tile various groove profiles. The “circular”, “valley”, and “reversed saw tooth” grooves do not produce high direct stiffness, since they partly increase the groove depths in the direction of lubricant flow, causing to reduce the pumping action of the bearing. The maximum direct stiffness can be obtained by the “rectangular”, “saw tooth”, and “step” grooves. With the same cross sectional area of the grooves, these three grooves have the same maximum stiffness, damping coefficients, and frictional torque. Among these recommendable grooves, the saw tooth groove may keep its original profile for long, enduring metal-to-metal contact during startup and shutdown.

  • PDF