• 제목/요약/키워드: Starting current

Search Result 625, Processing Time 0.028 seconds

A Protection Algorithm for DC Railway Systems Considering Train Starting (기동방식을 고려한 DC급전계통 보호알고리즘)

  • Kwon Y. J.;Choi D. M.;Kang S. H.;Han M. S.;Lee J. K.
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.307-309
    • /
    • 2004
  • A DC railway system has low feeder voltage, The remote fault current can be smaller than the current of load starting. So it is important to discriminate between the small fault current and the train starting current. The train starting current increases step by step but the fault current increases all at once. So the type of $\bigtriangleup I\;relay(50F)$ was developed using the different characteristics between the load starting current and the fault current. As for the train starting current, the time constant of train current at each step is much smaller than that of the fault current. To detect faults in U railway systems, an algorithm that is independent of train starting current. This algorithm use the time constant calculated by the method of least squares is presented in this paper.

  • PDF

Novel Soft Starting Algorithm of Single Phase Induction Motors by Using PWM Inverter

  • Kim, Hae-Jin;Hwang, Seon-Hwan;Kim, Jang-Mok
    • Journal of Power Electronics
    • /
    • v.18 no.6
    • /
    • pp.1720-1728
    • /
    • 2018
  • This paper proposes a novel soft starting algorithm by using PWM inverter technique to control an amplitude of the motor starting current at a single-phase induction motor (SPIM). Traditional SPIM starting methods such as a Split-Phase, Capacitor-Start, Permanent-Split Capacitor (PSC), Capacitor-Start Capacitor-Run (CSCR), basically cannot control the magnitude of starting current due to the fixed system structures. Therefore, in this paper, a soft starting algorithm based on a proportional resonant (PR) control with a variable and constant frequency is proposed to reduce the inrush current and starting up time. In addition, a transition algorithm for operation modes is devised to generate a constant voltage and constant frequency (CVCF). The validity and effectiveness of the proposed soft starting method and transition algorithm are verified through experimental results.

A Study on Starting Current-Time Characteristics of a Small Squirrol Cage Induction Motor (소형농형3상유전전동기의 기동전류-시간에 관한 연구)

  • 노창주;김윤식
    • 전기의세계
    • /
    • v.27 no.5
    • /
    • pp.69-75
    • /
    • 1978
  • 3 phase induction motor applied in the method of connecting it directly across the line needs large current when it starts. At that time, leakage magnetic pathes of interior of the motor are severely saturated and leakage reactances are decreased because of saturation. Consequently, increased current and raised powerfactor yield increase of starting torque. The author, noticing those phenomena, derived experimentally the raion of decreasing leakage reactance from the fact that when voltage applied to motor is increased under locked condition the magnitude of current and phase angle are varied, and determined tha equations of starting current and starting torque, considering the decrease of leakage reactance by the large starting current. The author calculated the characteristics of Current-Time and Speed-Time with the determined equation at specific load conditions, and compared the values obtained from above calculations with those from circle diagram's method and the practically recorded values at same load conditions. Therefore, the authos got a confidience that the results of the derived theory coincide with the practically measured values more well than circle diagram's results and circle diagram's equation should be modified in order to analize the starting status of a induction motor.

  • PDF

A Protection Scheme for DC Railway Systems (DC철도 급전계통 보호시스템 구성)

  • Kwon, Y.J.;Kang, S.H.;Oh, K.H.;Lee, J.K.;Lee, M.H.
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.91-94
    • /
    • 2003
  • A DC railway system has low feeder voltage, The fault current can be smaller than the current of load starting. So it is important to discriminate between the small fault current and the load starting current. The load starting current increases step by step but the fault current increases all at once. So the type of ${\Delta}I$ relay(50F) was developed using the different characteristics between the load starting current and the fault current. As for the load starting current, the time constant of load current at each step is much smaller than that of the fault current. First, to detect faults in DC railway systems, an algorithm using the time constant calculated by the method of least squares is presented in this paper. Secondly, to compose a protection scheme for DC railway systems is presented in this paper.

  • PDF

Starting Characterization of Induction Motor using Reactor Tap Change (리액터 탭 절환에 의한 유도전동기의 기동 특성)

  • Kim, Jong-Gyeum
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.63 no.1
    • /
    • pp.24-28
    • /
    • 2014
  • An induction motor is most widely used to obtain driving force in the industrial field. The induction motor is generated a high current at starting. A starting current is often more than five times of rated current. A high starting current can cause problems such as voltage drop in the power system. In order to solve these problems, a reactor starting method has been widely applied in a large motor capacity. There are differences in the operating characteristics of induction motor corresponding the switching time of reactor tap. In this study, I analyzed that current, torque, power of induction motor are different from changing time and tap setting values of reactor tap.

Analysis of Soft Start-up Characteristics of the Induction Motor Considering the Firing Angle (점호각을 고려한 유도전동기의 소프트 기동 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.6
    • /
    • pp.1007-1012
    • /
    • 2016
  • Induction motors are used widely in driving load of a fluid, such as a pump or a fan in the industry. Induction motor has been generated the voltage drop by the occurrence of a high current during startup. In addition, high start-up current can act as a mechanical stress on the shaft of the motor. So there is need a way to reduce the starting current. Soft start method is one of the many ways to reduce the starting current. This method uses silicon-controlled rectifiers(SCRs) for varying value of the voltage applied to the motor. There is a case for fixing or changing the thyristor firing angle to adjust the magnitude of the voltage. Starting power factor of induction motor is very low compared to the normal operation. Soft starting with the firing angle fixed needs to be considered a low power factor at startup. In this study, we compared the direct start characteristics and soft start characteristics considering the low power factor at the time of start-up. It was possible to confirm that the starting current and the voltage drop is present differently according to the firing angle.

Characteristics Analysis for Reactor Starting Method of 3-Phase Induction Motor Considering Saturation (포화성분을 고려한 3상 유도전동기 리액터 기동 특성 분석)

  • Kim, Jong-Gyeum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.65-70
    • /
    • 2012
  • Induction motor is the most widely used to obtain the driving force in the industrial site. Induction motor generates a high current at startup. Most of starting currents are often more than five times of rated current. This high starting current can cause problems such as the voltage drop in the system. In order to solve these problems, if the motor capacity is large, generally we use reactor starting method rather than direct on line starting method. When a high startup current passes through reactor, reactor can serve as a nonlinear elements. In this study, we analyzed that the current, torque and power of the induction motor are different from the change of linear and nonlinear components of the reactor magnetic field.

Optimal Starting Torque Control of Wound Rotor Induction Motor by Microprocessor (개용분 PFN-PMW의 유전특성에 관한 연구)

  • Park, Min-Ho;Jung, So-Woong
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.8
    • /
    • pp.316-324
    • /
    • 1984
  • In the wound rotor induction motor, the external resistor is usually added to the rotor circuit in order to limit the starting current. In this scheme, whilst the starting current is limited, the available torque is remarkably reduced. In this paper, to improve the starting characteristics the stator current can be maintained constant by adjusting the external resistor. To change the external resistor, teh chopper and the resistor is connected in parallel, and the chopper duty cycle is adjusted by microprocessor. The duty cycle is calculated according to the actual speed of motor by microprocessor look-up table map. In this suggested scheme, the starting characteristics are remarkably improved without over-current. The starting time of this system is reduced by 20-48 Percent compared with fixed extemal resistance system in the same load.

  • PDF

A New Protection Algorithm for DC Railway Systems (새로운 직류급전계통 보호 알고리즘)

  • Kwon V.J.;Kang S.H.;Hyun S.H.;Han M.S.;Lee J.K.
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1280-1285
    • /
    • 2004
  • ADC railway system has low feeder voltage, The fault current can be smaller than the current of load starting. So it is important to discriminate between the small fault current and the load starting current. The load starting current increases step by step but the fault current increases all at once. As for the load starting current, the time constant of load current at each step is much smaller than that of the fault current. First, to detect faults in DC railway systems, an algorithm using the time constant calculated by the method of least squares is presented in this paper.

  • PDF

A Protection Algorithm for DC Railway Systems Using Estimation of Time Constant Based on Fourier Transform (Fourier 변환 기반 시정수 추정 알고리즘을 이용한 직류 급전계통 보호 알고리즘)

  • Kwon, Y.J.;Choi, D.M.;Kang, S.H.;Han, M.S.;Lee, J.K.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11b
    • /
    • pp.14-16
    • /
    • 2004
  • A DC railway system has low feeder voltage, The remote fault current can be smaller than the current of load starting. So it is important to discriminate between the small fault current and the load starting current. The load starting current increases step by step but the fault current increases all at once. As for the load starting current, the time constant of load current at each step is much smaller than that of the fault current. To detect faults in DC railway systems, an algorithm using the time constant calculated by the method of least squares was presented. But, It have a weakness about harmonic to calculate time constant. So in this paper, new protection algorithm for DC railway systems using estimation of time constant based on fourier transform was presented.

  • PDF