• Title/Summary/Keyword: Start Motor

Search Result 289, Processing Time 0.022 seconds

An Off-line Maximum Torque Control Strategy of Wound Rotor Synchronous Machine with Nonlinear Parameters

  • Wang, Qi;Lee, Heon-Hyeong;Park, Hong-Joo;Kim, Sung-Il;Lee, Geun-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.11 no.3
    • /
    • pp.609-617
    • /
    • 2016
  • Belt-driven Starter Generator (BSG) differs from other mild hybrid systems as the crankshaft of vehicle are not run off. Motor permits a low-cost method of adding mild hybrid capabilities such as start-stop, power assist, and mild levels of regenerative braking. Wound rotor synchronous motor (WRSM) could be adopted in BSG system for HEV e-Assisted application instead of the interior permanent magnet synchronous motor (IPMSM). In practice, adequate torque is indispensable for starter assist system, and energy conversion should be taken into account for the HEV or EV as well. Particularly, flux weakening control is possible to realize by adjusting both direct axis components of current and field current in WRSM. Accordingly, this paper present an off-line current acquisition algorithm that can reasonably combine the stator and field current to acquire the maximum torque, meanwhile the energy conversion is taken into consideration by losses. Besides, on account of inductance influence by non-uniform air gap around rotor, nonlinear inductances and armature flux linkage against current variation are proposed to guarantee the results closer to reality. A computer-aided method for proposed algorithm are present and results are given in form of the Look-up table (LUT). The experiment shows the validity of algorithm.

Implemention of a DTIF Controller for Robust Drive of a 3 Phase Induction Motor in High-Speed Elevator (고속 엘리베이터에서 3상 유도전동기의 강건한 구동을 위한 DTIF 제어기의 구현)

  • 김동진;강창수;한완옥
    • The Proceedings of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.9 no.3
    • /
    • pp.88-96
    • /
    • 1995
  • High speed elevator requires precise drive included in zero speed at start/stop drive for the high stability and controllability. The vector control techniques, which have been used for the precise operation of induction motor, can be divided into two classes; The indirect vector control by slip frequency and the direct vector control by field orientation. The existing direct vector control technique has a robustness against the change of motor parameter and the existing indirect vector control technique has a strength of control ability in the wide speed range comparatively. This study presents the DTIF (Direct Torque Indirect Flux) controller which has robust movement in the transition state and in about zero and low speed using the control technique in which torque is controlled by the direct vector technique and flux is controled by indirect vector technique. The proposed system is verified by simulation and experiment for driving 3 phase induction motor. The process of transition which is from about zero speed and low speed to high speed is compared and measured to specification of phase voltage, phase current and DC link current. It is verified that DTIF controller show robust and stable speed variation.

  • PDF

Safety-Related Bus Voltage Variation during Large Induction Motor Start-up in 1400MW Light Water Reactor Type Nuclear Power Plant (1400MW급 경수로형 원자력발전소의 대용량 유도전동기 시동시 안전관련 모선 전압 변동)

  • Lee, Cheoung Joon;Kim, Chang Kook;Noh, Young Seok;Joo, Young Hwan
    • Plant Journal
    • /
    • v.12 no.4
    • /
    • pp.37-43
    • /
    • 2016
  • Power system which provides electricity to the accident mitigation load for nuclear power plant should be verified to maintain the proper voltage level under the various loading and source conditions. For this purpose, it was needed to collect the voltage data of safety related buses during operation of the Reactor Coolant Pump(RCP) motor and Component Cooling Water Pump(CCWP) motor, respectively, under the certain loading condition of the plant. The data (such as, voltage, current, power factor) collected from actual measurement were used to modify the existing ETAP model and then the reanalysis was conducted to simulate the testing conditions. Through these actual measurement and analysis, it ensures that the existing electrical system analysis including assumptions and methods was conducted properly. Finally, the voltage of safety related buses was not dropped below the acceptable level, and the discrepancy between two results was within the limit.

  • PDF

Outdoor Smart Follow Cart using Bluetooth Function of Smartphone (스마트폰의 Bluetooth 기능을 활용한 실외용 스마트 팔로우 카트)

  • Kim, Ji-Hoon;Kim, Young-Bin;Choi, Seong-Rak;Han, Young-Oh
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.17 no.5
    • /
    • pp.959-968
    • /
    • 2022
  • In this paper, we intend to develop a cart with the convenience of moving objects or items that are difficult to hold by the hand of the disabled and the elderly from outdoor activities to a moving location. Using GPS module, DC motor, Bluetooth module, magnetometer sensor, and Blynk application, the smart follow cart was programmed to accurately know the owner's location while following the cart. The values of latitude and longitude of the magnetometer sensor are set so that the correct leverage value can be obtained in the lead for fine adjustment of the start and stop angles so that the user's position can be freely detected. The above motor driver L298n was connected to the motor to drive the DC motor at a fine angle. A smart follow cart was implemented that receives location signals according to the direction of the owner by turning on/off the mobile phone app as a switching role by connecting the GPS through Bluetooth wireless communication using a smartphone.

Start and Stop Characteristics of Single-Rod Electro-Hydrostatic Actuator (전동기 일체형 편로드 유압액추에이터의 기동 및 정지특성해석)

  • Jung, Gyu-Hong
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.35 no.11
    • /
    • pp.1483-1490
    • /
    • 2011
  • Electro-hydrostatic actuators(EHAs), which are usually composed of a direct motor-driven hydraulic pump and a cylinder, have been widely adopted as aircraft actuation systems because of their benefits in terms of improved efficiency, weight savings and the fact that they use a standalone power source. Since the recent trend in construction vehicles has been focus on energy savings in their hydraulic systems, EHAs are expected to be potential substitutes for conventional power transmission, since they are capable of energy recovery as well as highly efficient pump control. In this paper, the start and stop characteristics of EHAs were investigated through cracking pressure analysis of the pilot-operated check valve(PCV), which enables the cylinder to standstill against an external load with no holding effort from the hydraulic pump. A mathematical model that includes the load dynamics and the EHA's internal hydraulic circuit was derived for simulation with the MATLAB Simulink package. This model verified the PCV's opening and closing sequence, which in turn affects the EHA's start and stop characteristics.

The Effects of Fatigue on Cognitive Performance in Police Officers and Staff During a Forward Rotating Shift Pattern

  • Taylor, Yvonne;Merat, Natasha;Jamson, Samantha
    • Safety and Health at Work
    • /
    • v.10 no.1
    • /
    • pp.67-74
    • /
    • 2019
  • Background: Few studies have examined the effects of a forward rotating shift pattern on police employee performance and well-being. This study sought to compare sleep duration, cognitive performance, and vigilance at the start and end of each shift within a three-shift, forward rotating shift pattern, common in United Kingdom police forces. Methods: Twenty-three police employee participants were recruited from North Yorkshire Police (mean age, 43 years). The participants were all working the same, 10-day, forward rotating shift pattern. No other exclusion criteria were stipulated. Sleep data were gathered using both actigraphy and self-reported methods; cognitive performance and vigilance were assessed using a customized test battery, comprising five tests: motor praxis task, visual object learning task, NBACK, digital symbol substitution task, and psychomotor vigilance test. Statistical comparisons were conducted, taking into account the shift type, shift number, and the start and end of each shift worked. Results: Sleep duration was found to be significantly reduced after night shifts. Results showed a significant main effect of shift type in the visual object learning task and NBACK task and also a significant main effect of start/end in the digital symbol substitution task, along with a number of significant interactions. Conclusion: The results of the tests indicated that learning and practice effects may have an effect on results of some of the tests. However, it is also possible that due to the fast rotating nature of the shift pattern, participants did not adjust to any particular shift; hence, their performance in the cognitive and vigilance tests did not suffer significantly as a result of this particular shift pattern.

Initial Rotor Position Detection of a Toroidal SRM Using the Rate of Change of Current (전류변화율을 이용한 토로이달 SRM의 초기위치 경출 방법)

  • Yang Hyong-Yeol;Lim Young-Cheol
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.54 no.1
    • /
    • pp.26-32
    • /
    • 2005
  • Rotor position information is essential in the operation of the switched reluctance motor(SRM) drive for generation the phase current switching signals. When an incremental encoder is used as a rotor position sensor, the initial rotor position can not be detected. Some sensorless rotor position estimation methods also have the same problem. In these systems, to initially align the rotor, the forced alignment method has a delay and reverse rotation before the motor can start. Therefore it can not be acceptable for unidirectional drive systems. So the forced alignment method is not desirable in all drive systems and the research on the SRM drives should be directed to a system without rotor alignment. In this paper, a new detection method of initial rotor position using the rate of change of current is suggested. Firstly, di/dt versus θ/sub R/ reference table, which is the relation between the rate of change of current and rotor position, is generated and then the squared Euclidean distance method is used to estimate the rotor position based on the table. The simulated and experimental results are presented demonstrating the feasibility and accuracy of this method.

Development of Clamping Force Estimation Algorithm and Clamp-force Sensor Calibration on Electromechanical Brake Systems (전동식 브레이크 시스템의 클램핑력 센서 교정 및 클램핑력 추정 알고리즘 개발)

  • Park, Giseo;Choi, Seibum;Hyun, Dongyoon
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.24 no.3
    • /
    • pp.365-371
    • /
    • 2016
  • The electromechanical brake (EMB) is one of future brake systems due to its many advantages. For implementation of the EMB, the correct feed back about clamping force is necessary. Keeping commercialization of the EMB in mind, it is strongly demanded that an expensive load cell measuring the clamping force is replaced with an estimation algorithm. In addition, an estimation of the kissing point where the brake pads start to come into contact with a disk wheel is proposed in this paper. With these estimation algorithms, the clamping force can be expressed as a polynomial characteristic curve versus the motor angle. Also, a method for calibration of measured values by the load cell is proposed and used for an actual characteristic curve. Lastly, the performance of the proposed algorithms is evaluated in comparison with the actual curve on a developed EMB test bench.

A Study on the precious stopping control for the automatic electric rail cars (도시철도 전차의 정위치 정차 제어에 관한 연구)

  • Park, Mun-Gyu;Kim, Gyu-Sik
    • Proceedings of the KIEE Conference
    • /
    • 2006.04a
    • /
    • pp.228-230
    • /
    • 2006
  • While trains perform a complete precision stopping control at stop point, it is essential to keep better commuters comfort in prompt. Because a train's brake force tends to increase a brake effort in a low speed and a low brake effort, a brake force in motor cars must be increased to keep better passenger comfort, to control the special braking qua1ities and to prevent the impact of the automatic coupler rather than trailer's, Rail cars must have a special braking process for the train stopping control. In the train stop mode, the train stopping control is designed to start at 20km/h. It starts by Dynamic brake blending, and then finally stops by only the friction. If these process are not exactly activated, the train may fail a complete precision stop. In this report, it studied the electric and friction brake processing during the precious stopping control. To achieve exact test results, the speed reference has to be reduced the calculated difference. In the precision stopping control. the ways of the keeping brake force in motor car was analyzed and some solutions of controling air pressure was brought up by means of direct test in main line, This study was based on line 5 in Seoul Metropolitan subway.

  • PDF

Analysis of Cylinder Compression Pressure & Valve Timing by Motoring Current & Crank Signal during Cranking (모터링시 전류 파형과 크랭크각 센서를 이용한 기관의 압축압력 및 밸브 타이밍 분석)

  • Kim, In-Tae;Park, Kyoung-Suk;Shim, Beom-Joo
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.5
    • /
    • pp.45-50
    • /
    • 2011
  • Compression pressure of individual cylinder and valve timing have big influence on combustion pressure, indicated mean effective pressure (IMEP), emission, vibration, combustion noise and many other combustion parameters. Conventional method, however, to check compression pressure uniformity is done by mechanical pressure gage and valve timing is checked manually. This conventional method causes inaccuracy of cylinder pressure measurement because of different cranking speed results from battery status and temperature. Also to check valve timing, related FEAD parts should be disassembled and timing mark should be checked. This study describes and suggests new methodology to measure compression pressure by analysis of start motor current and to check valve timing by cylinder pressure with high accuracy. Results, it is found that detection of bulky as well as small leaky cylinder is possible by cranking motor current analysis and wrong valve timing can be detected by cylinder pressure analysis and cam and crank sensor signal.