• Title/Summary/Keyword: Standardization Methods

Search Result 853, Processing Time 0.028 seconds

Content Analysis and Classification for Polygonati Odorati Rhizoma and Polygonati Rhizoma by Steroidal Saponin (Steroidal Saponin을 이용한 위유, 황정의 분류 및 함량 분석법 개발)

  • Kim, Sun-Gun;Shin, So-Young;Moon, Ye-Ji;Seo, Ji-Yoon;Kim, Ho-Kyoung;Whang, Wan-Kyunn
    • YAKHAK HOEJI
    • /
    • v.54 no.6
    • /
    • pp.441-448
    • /
    • 2010
  • In present study, classification and quality control of Genus Polygonatum were developed using the isolated from Polygonati Odorati Rhizoma and Polygonati Rhizoma. 3 components were isolated from Butanol fractions of Polygonati Rhizoma, and 2 components were isolated from Hexane and Butanol fractions of Polygonati Odorati Rhizoma. All the components were obtained using silica gel and ODS column chromatography. The compounds were identified as adenosine, 14-hydroxylfurost-5-ene-3-O-${\beta}$-D-glucopyranosyl-($1{\rightarrow}2$)-O-${\beta}$-D-glucopyranosyl-($1{\rightarrow}4$)-O-${\beta}$-D-galactopyranosyl-26-O-${\beta}$-D-glucopyranoside, 22-O-methyl-14-hydrocxyfurost-5-ene-3-O-${\beta}$-D-glucopyranosyl-($1{\rightarrow}2$)-O-${\beta}$-D-glucopyranosyl-($1{\rightarrow}4$)-O-${\beta}$-Dgalactopyranosyl-26-O-${\beta}$-D-glucopyranoside, ${\beta}$-Sitosteryl-3-O-${\beta}$-D-D-glucopyranoside, 14-hydoxylfurost-5-ene-3-O-${\beta}$-Dglucopyranosyl-($1{\rightarrow}2$)-O-[${\beta}$-D-xylopyranosyl-($1{\rightarrow}3$)]-O-${\beta}$-D-glucopyranosyl-($1{\rightarrow}4$)-O-${\beta}$-D-galactopyranoside through physicochemical data, spectroscopic methods ($^1H$-NMR, $^{13}C$-NMR, Mass) according references. The quality control of genus Polygonatum were conducted using HPLC quantitative analysis of 14-hydroxylfurost-5-ene-3-O-${\beta}$-D-glucopyranosyl-($1{\rightarrow}2$)-O-${\beta}$-D-glucopyranosyl-($1{\beta}4$)-O-${\beta}$-D-galactopyranosyl-26-O-${\beta}$-D-glucopyranoside, 14-hydoxylfurost-5-ene-3-O-${\beta}$-D-glucopyranosyl-($1{\rightarrow}2$)-O-[${\beta}$-D-xylopyranosyl-($1{\rightarrow}3$)]-O-${\beta}$-D-glucopyranosyl-($1{\rightarrow}4$)-O-${\beta}$-D-galactopyranoside in 30 samples collected throughout Korea and China. This method provided a tool for standardization of mix or misusing the commercial Odorati Rhizoma and Polygonati Rhizoma. As a result, contained quantity of 14-hydroxylfurost-5-ene-3-O-${\beta}$-D-glucopyranosyl-($1{\rightarrow}2$)-O-${\beta}$-D-glucopyranosyl-($1{\rightarrow}4$)-O-${\beta}$-D-galactopyranosyl-26-O-${\beta}$-D-glucopyranoside was measured $0.008{\pm}0.006%$ and 14-hydoxylfurost-5-ene-3-O-${\beta}$-D-glucopyranosyl-($1{\rightarrow}2$)-O-[${\beta}$-D-xylopyranosyl-(13)]-O-${\beta}$-D-glucopyranosyl-($1{\rightarrow}4$)-O-${\beta}$-Dgalactopyranoside was measured $0.026{\pm}0.012%$.

A Study on the Complications of Acute Ischemic Cerebrovascular Disease Patients (급성기 허혈성 뇌중풍(중풍)의 합병증에 관한 연구)

  • Hsia, Yu-Chun;Jung, Ki-Yong;Go, Ho-Yeon;Jung, Seung-Min;Jung, Hee;Ko, Mi-Mi;Kang, Mi-Suk;Choi, You-Kyung;Kim, Dong-Woo;Han, Chang-Ho;Cho, Ki-Ho;Park, Jong-Hyung;Ko, Seung-Gyu;Jun, Chan-Yong
    • The Journal of Internal Korean Medicine
    • /
    • v.28 no.1
    • /
    • pp.25-33
    • /
    • 2007
  • Background and Purpose : This study was to survey complication according to the TOAST classification and Sasangconstitution in first-ever AICD (acute ischemic cerebrovascular disease) patients. Methods : From 1 Oct. 2005 to 31 Oct. 2006. 97 patients with a first-ever stroke were included in the study. patients were hospitalized within 14 days after the onset of stroke at Kyungwon University Incheon Oriental Hospital. We recorded patient's complications according to the standard operation procedure of 'A stroke study for standardization and science on Korean Medicine' Results : Complications were recorded in 23 cases (24%). The most common complication was upper respiration infection in 11 cases (11%). No statistical significance was shown between complications of AICD and Sasangconstitutions, but complications rate of LAA was higher than SVO in AICD patients (odds ratio 4.17 95% CI 1.127${\sim}$7.307). Conclusions : To acquire more concrete data on this theme. we need further and larger scale research.

  • PDF

Standardization of the Comprehensive Attention Test for the Korean Children and Adolescents (국내 아동 및 청소년 주의력 평가를 위한 종합주의력검사의 표준화 연구)

  • K.Yoo, Han-Ik;Lee, Jung-Sun;Kang, Sung-Hee;Park, Eun-Hee;Jung, Jae-Suk;Kim, Boong-Nyun;Son, Jung-Woo;Park, Tae-Won;Kim, Bong-Seok;Lee, Young-Sik
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.20 no.2
    • /
    • pp.68-75
    • /
    • 2009
  • Objectives: This study was conducted in order to develop and obtain the nonnative data of the computerized Comprehensive Attention Test(CAT) in Korean children and adolescents. It also aimed to evaluate the reliability and validity of the CAT. Methods: We developed the computerized CAT which includes the selective attention task, the sustained attention to response task, the flanker task, the divided attention task, and the spatial working memory task. We investigated the test-retest reliability and the construction validity of this computerized version by using the data from 21 children, and gathered the nonnative data of 9l2 subjects, aged 4 to 15 years, dwelling in the Metropolitan Seoul area in 2008. Results: No statistical differences between means of the tests and retests of the CAT were observed. The mean of the correlation coefficient of the test-retest scores was 0.715. The results from the factor analyses explained 51.7% of the cumulative variance. In addition, the nonnative data for all of the CAT subtests were obtained. Conclusion: The computerized CAT can be used as a reliable and valid tool in both clinical and research settings for Korean children and adolescents with or without neuropsychiatric conditions such as attention deficit.

  • PDF

A Development of Simulation System based on Scenario for Evaluation of e-Navigation MSP (e-Navigation MSP 평가를 위한 시나리오 기반 시뮬레이션 시스템 개발)

  • Shin, Il-Sik;Hwang, Hun-Gyu;Lee, Jang-Se;Yu, Yung-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.1
    • /
    • pp.86-93
    • /
    • 2015
  • Recently, the development of Maritime Service Portfolios (MSPs) for the safe navigation of ship has been discussed internationally. For the successful service of the MSPs, first of all, studies for the standardization about the structure and data structure of MSPs should be preceded. Also, it is necessary to evaluate and assess whether the services are effective for safe navigation, and provided data and portrayal methods are proper. However, because great dangers will be accompanied when untested MSPs about their effectiveness and safety are applied in real ship navigation, it is necessary that effectiveness and safety of the MSPs should be proven under various navigational conditions and environments by simulation. In this paper, we propose a 3D navigation simulation system using desktop PC environment, which is proper for evaluating the effectiveness of MSPs. The system consists of three modules which are simulation scenario editor, 3D visualization of navigational environment and 2D navigational equipment. The scenario editor module provides an environment setting for simulation, such as properties, routes and positions of vessels and aids to navigations. It also provides functions to create a scenario for the simulation to operate. Additionally, the 3D visualization module provides 3D navigational environment which shows interplay between geographical and navigational environment based on the created scenario. The 2D navigational equipment module provides visualization functions of various navigational equipment, shows the interaction between ship's navigational equipment and ship's environment. The simulation scenario, in which various kinds of ships are routing in the port, is created by the developed simulation system, and experimented whether this developed system is appropriate to evaluate and assess the MSPs developed by the International Maritime Organization.

The Regional Characteristics of 119 Ambulance Dispatch, the Distance and Response Time to the Scene (119 구급서비스 지역별 출동특성 및 출동거리와 현장도착시간과의 관계)

  • Lee, Kyoung-youl;Moon, Jun-dong;Choi, Eun-sook
    • The Journal of the Korea Contents Association
    • /
    • v.16 no.1
    • /
    • pp.482-492
    • /
    • 2016
  • Purpose This study is to investigate regional characteristics of 119 ambulance dispatch and the relationship between the distance and response time to the scene. Methods This study was retrospectively conducted 119 running sheets with 1,321 patients who had been transferred to the hospital by 119 ambulance during ambulance attendant training. The training was performed at two, five and three fire station in Seoul, Daejeon and Chungnam respectively, from June 24, 2013 to July 19, 2014. Results Almost the emergency medical services provided were no more than basic first aid in all regions. The patients transferred by 119 ambulance in Seoul were more than other region. The time of call to scene and scene to hospital were the slowest in Chungnam. The major reason of call 119 was due to disease in Seoul and Daejeon, however due to injury in Chungnam. Conclusion Our study suggests that learning from ambulance attendant training course could diverse from region to region. It is, therefore, needed that standardization of ambulance attendant training course, appropriate logistics and resource allocation for providing universal quality of emergency medical services.

Design and Development of an EHR Platform Based on Medical Informatics Standards (의료정보 표준에 기반한 EHR 플랫폼의 설계 및 개발)

  • Kim, Hwa-Sun;Cho, Hune;Lee, In-Keun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.21 no.4
    • /
    • pp.456-462
    • /
    • 2011
  • As the ARRA enacted recently in the United States, the interest in EHR systems have been increased in the field of medical industry. The passage of the ARRA presents a program that provides incentives to office-based physicians and hospitals adapting the EHR systems to guarantee interoperability with various medical standards. Thanks to the incentive program, a great number of EHR systems have been developed and lots of office-based physicians and hospitals have adapted the EHR systems certified by CCHIT. Keeping pace with the rapid changes in the market of healthcare, some enterprises try to push in to the United States healthcare market based on the experience acquired by developing EHR systems for hospitals in Korea. However, the developed system must be customized because of the different medical environment between Korea and the United States. In this paper, therefore, we design and develop an integrated EHR platform to guarantee the interoperability between different medical information systems based on medical standard technologies. In the developed platform, an integrated system has been composed by integrating various basic techniques such as data transmission standards and its methods, medical standard terminologies and its usage, and knowledge management for medical decision-making support. Moreover, medical data can be processed electronically by adapting an HL7 interface engine and the terminologies for exchanging medical information and the standardization of medical information. We develop SeniCare, an EHR system for supporting ambulatory care of the office-based physicians, based on the platform, and we verify the usability of the platform by confirming whether SeniCare satisfies the criteria of "meaningful use" issued by CMS or not.

Quality Characteristics and Antioxidant Activities of Commercial Jeupjang (일부 시판 즙장의 품질 특성 및 항산화 활성)

  • Kim, Ha-Yun;Hwang, In-Guk;Yoo, Seon-Mi;Hwang, Young;Cha, Sung-Mi;Kim, Haeng-Ran
    • The Korean Journal of Community Living Science
    • /
    • v.21 no.4
    • /
    • pp.571-579
    • /
    • 2010
  • Jeupjang has long been considered only a local delicacy. So, it has gradually been forgotten because its name and definition have not been established. This study was performed in order to provide some basic data by comparing the general components, color, free amino acids, free sugar, organic acids and antioxidant activities between commercial Jeupjang(GG, GD, JM, NJ, NS). Moisture contents, crude protein, crude fat and crude ash contents of Jeupjang were 48.07~61.77%, 4.08~10.53%, 3.92~4.64%, and 3.63~9.95%. pH, titrable acidity and salt in Jeupjang were 4.32~5.50, 9.37~14.82 mL(1N-NaOHmL), and 3.27~8.90%. Amino-type nitrogen content is 42.05~ 138.83mg%. Lightness(L), redness(a) and yellowness(b) values in color of Jeupjang were10.04~21.89, 18.92~28.80, and 17.16~37.56. The total content of free amino acids in commercial Jeupjang ranged from 35.22mg% to 306.02mg% in which it showed wide variation among samples. The major free amino acids were glutamic acid, aspartic acid, alanine and proline. The major free sugars were fructose(0.31~1.60%), glucose(6.20~ 13.61%) and maltose(7.34~10.01%). The major organic acids were succinic acid(29.08~ 103.62 mg%) and citric acid(3.08~108.69 mg%). Total polyphenol contents were from 1.16 mg/g to 1.78 mg/g, DPPH radical scavenging activity is from 0.57 AEAC to 1.53 AEAC and ABTS radical scavenging activity is from 1.58 AEAC to 2.85 AEAC. This result might cause the differences of soybean composition, processing methods and brewing periods. For the succession of traditional fermented food such as Jeupjang, quality standards are required. To this end, the standardization of manufacturing processes must be followed.

Development of Quantitative Exposure Index in Semiconductor Fabrication Work (반도체 FAB근무에 대한 정량적 노출지표 개발)

  • Shin, Kyu-Sik;Kim, Taehun;Jung, Hyun Hee;Cho, Soo-Hun;Lee, Kyoungho
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.3
    • /
    • pp.187-192
    • /
    • 2017
  • Objectives: It is difficult to identify exposure factors in the semiconductor industry due to low exposure levels to hazardous substances and because various processes take place in fabrication (FAB). Furthermore, a single worker often experiences a variety of job histories, so it is difficult to classify similar exposure groups (SEG) in the semiconductor industry. Therefore, we intend to develop a new exposure index, the period of working in FAB, that is applicable to the semiconductor industry. Methods: First, in specifying the classification of jobs, we clearly distinguished whether they were FAB workers or non-FAB workers. We checked FAB working hours per week through questionnaires administered to FAB workers. We derived an exposure index called FAB-Year that can represent the period of working in FAB. FAB-Year is an index that can quantitatively indicate the period of working in FAB, and one FAB-Year is defined as working in FAB for 40 hours per week for one year. Results: A total of 8,453 persons were surveyed, and male engineers and female operators occupied 90% of the total. The average total years of service of the subjects was 9.7 years, and the average FAB-Year value was 6.8. This means that the FAB-working ratio occupies 70% of total years of service. The average FAB-Year value for female operators was 8.4, for male facility engineers it was 7.7, and for male process engineers it was 3.5. A FAB-Year standardization value according to personal information (gender, job group, entry year, retirement year) for the survey subjects can be calculated, and standardized estimation values can be applied to workers who are not participating in the survey, such as retirees and workers on a leave of absence (LOA). Conclusions: This study suggests an alternative method for overcoming the limitations on epidemiological study of the semiconductor industry where it is difficult to classify exposure groups by developing a new exposure index called FAB-Year. Since FAB-Year is a quantitative index, we expect that various approaches will be possible in future epidemiological studies.

Pediatric Voice Handicap Index-Korean(pVHI-K) : A Pilot Study for Standardization (한국어판 소아음성장애지수(pVHI-K : Pediatric Voice Handicap Index-Korean) : 표준화를 위한 예비연구)

  • Park, Sung-Shin;Choi, Seong-Hee;Hong, Young-Hye;Jeong, Nyun-Gi;Sung, Myung-Whun;Kim, Kwang-Hyun;Kwon, Tack-Kyun
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.22 no.2
    • /
    • pp.137-142
    • /
    • 2011
  • Background and Objectives : The aim of this study is to introduce Korea version of pediatric VHI and to compare pVHI-K scores between children with dysphonia and children without voice problems before pVHI-K is developed as a preliminary study. Additionally, the relationship between pVHI and acoustic measures were investigated. Materials and Methods : pVHI-K scores in normal group were obtained from 15 parents who have children with no present or past history of a voice disorder, hearing loss, or related disability that can affect the their voice or speech. Dysphonia group consisted of 15 parents who have children with bilateral vocal fold nodule's at Department of Otolaryngology, the Seoul National University Hospital (SNUH). pVHI-K and acoustic parameters were measured in two group. Results : The mean pVHI scores (total, functional, physical, emotional) in normal group were 2.33 (T), 0.80 (F) 1.33 (P) and 0.27 (E), respectively whereas those of pVHI in children group with dysphonia were 23.13 (T), 11.07 (F), 5.73 (P) and 6.13 (E), respectively and significant differences were revealed in total pVHI score as well as in all of the sub-pVHI scores. Moreover, significant correlation between pVHI-K parameters (T, F, P) and acoustic measures [Shimmer(%)] were shown in children in dysphonia group. Conclusion : Reported by parents can be useful as a supplementary clinical tool for diagnosing and measuring treatment effectiveness in young children with dysphonia.

  • PDF

Chemical Preservation Methods of Urine Sediment for Quality Control (정도관리를 위한 요침사의 화학적 보존방법)

  • Cho, Soung Suck;Kim, Myong Soo;Shin, Kyung-A
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.49 no.4
    • /
    • pp.359-365
    • /
    • 2017
  • There is greater standardization of quality control for microscopic examination of urine than for physicochemical test. In this study, we investigated whether it is possible to control the sediment accuracy by microscopic examination through the real thing by preserving the essential sediment with glutaraldehyde, which is required for the rationality of sediment quality control. A urine specimen was prepared using 2.5% glutaraldehyde as a preservation solution. Samples treated with urine preservatives confirmed the morphological deformation of the cells for four weeks at intervals of one week and confirmed whether they should be preserved for 4 weeks thereafter. After preparing the required sediment slide, two more slides were produced; one was stored in a refrigerator for, and the other was stored at room temperature. The morphological deformation of the specimen was confirmed. Glutaraldehyde has the effect of preserving the refrigerated essential sediments and storing them for up to 8 weeks, refrigerated storage after slide production, stabilized by 3 days. Moreover, after treatment with preservatives, the production of the slide and comparison between the measured values between the laboratories and examiners showed a low consistency. In conclusion, we showed that the urine sediment components can be preserved, and it can be used for quality control and education through real objects.