• Title/Summary/Keyword: Standard value

Search Result 4,826, Processing Time 0.032 seconds

Measurement of Joint Aperture Using 3-D Laser Profilometer (3차원 레이저 측정기를 이용한 절리 간극의 측정)

  • 이희석;이연규;이희근
    • Economic and Environmental Geology
    • /
    • v.33 no.4
    • /
    • pp.309-320
    • /
    • 2000
  • Aperture is an important parameter for determining the hydraulic characteristics of fractured media. In this study the topography of artificial rock joint surface was measured using 3D laser profilometer to analyze the aperture distribution. The initial aperture distribution was determined when the contact area became one percent of total joint surface. The initial aperture distribution of granite joint, with the mean value of 0.78 mm and the standard deviation of 0.34 mm was much different from that of the marble joint, with the mean value of 0.57 mm and the standard deviation of 0.26 mm. Apertures of both granite and marble showed normal distributions. Aperture distribution with the contact area of 25% was also analyzed. Mean value was decreased to one third compared to the initial aperture, but the standard deviation was decreased slightly. To determine the spatial correlation of the aperture distribution variogram analysis was carried out on the initial aperture data. Most experimental variograms were fitted well with exponential model. It is expected that the measured aperture characteristics can be used for stochastic analysis of fluid flow through rock joints.

  • PDF

Scene Change Detection using the Automated Threshold Estimation Algorithm

  • Ko Kyong-Cheol;Rhee Yang-Won
    • The Journal of Information Systems
    • /
    • v.14 no.3
    • /
    • pp.117-122
    • /
    • 2005
  • This paper presents a method for detecting scene changes in video sequences, in which the $chi^{2}$-test is modified by imposing weights according to NTSC standard. To automatically determine threshold values for scene change detection, the proposed method utilizes the frame differences that are obtained by the weighted $chi^{2}$-test. In the first step, the mean and the standard deviation of the difference values are calculated, and then, we subtract the mean difference value from each difference value. In the next step, the same process is performed on the remained difference values, mean-subtracted frame differences, until the stopping criterion is satisfied. Finally, the threshold value for scene change detection is determined by the proposed automatic threshold estimation algorithm. The proposed method is tested on various video sources and, in the experimental results, it is shown that the proposed method is reliably estimates the thresholds and detects scene changes.

  • PDF

A Study on the Quality Control for the Circulation Steps including Productipn, Transportation, Selling about Hamburger & Sandwich in Convenience Store (편의점에서 판매되는 햄버거와 샌드위치의 유통과정중 품질관리에 관한 연구)

  • Kim, Heh-Young;Song, Yong-Hye
    • Journal of the Korean Society of Food Culture
    • /
    • v.11 no.4
    • /
    • pp.465-473
    • /
    • 1996
  • The purpose of this study was to evaluate microbiological hazards in the steps of production, transportation and selling of hamburger and sandwich that were marketed in CVS, then to identify methods of control. The reasults are as follows: As the reasult of operation surroundings of manufacturerand reserch of circulation, $4{\sim}6$ hours are needed from manufacturer to CVS. Also transportation car mean temperature was $10^{\circ}C$ which exceeds the standard of $7^{\circ}C$ or below. Hamburger: Critical control points identified were purchasing, cooking, post-preparation, transportation and holding at CVS. As the reasult of microbial analysis following the case of holding methods and reheating at CVS, microbes of cold holding and reheat after cold holding was within standard value. But in the case of room temperature microbes exceeded standard value. Sandwich: Critical control points identified were purchasing, cooking, post-preparation, transportation and holding at CVS. As the reasult of microbial analysis following the case of holding methods and reheating at CVS, total plate counts of cold holding and reheat after cold holding was within standard value. But in the case of room temperature holding after 24 hours total plate counts exceeded standard value. In the case of room temperature holding the number of microbes increased according to the passage of time. As a reasult of food poisoning bacteria, it was negative in every test in sample against V. parahaemolyticus, Salmonella, S. aureus.

  • PDF

Applicability of Huff Model & ABM Method for Discharge Capacity of Sewer Pipe (하수관거 통수능 해석을 위한 Huff 모형과 ABM 법의 적용성 분석)

  • Hyun, Inhwan;Jeon, SeungHui;Kim, Dooil
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.36 no.4
    • /
    • pp.229-237
    • /
    • 2022
  • The sewer capacity design have been based on the Huff model or the rational equation in South Korea and often failed to determine optimal capacity, resulting in frequent urban flooding or over-sizing. A time distribution of rainfall (i.e., Huff or ABM method) could be used instead of a rainfall hyetograph obtained from statistical analysis of previous rainfalls. In this study, the Huff method and the ABM method, which predict the time distribution of rain intensity, which are widely used to calculate sewage pipe drainage capacity using the SWMM, were compared with the standard rainfall intensity hyetograph of Seoul. If the rainfall duration was 30 minutes to 180 minutes, the rainfall intensity value calculated by the Huff model tended to be less than the rainfall intensity value of the standard rainfall intensity in the initial 5-10 minutes. As a result, more than 10% to 30% of under-design would be made. In addition, the rainfall intensity value calculated by the Huff model from the section excluding the initial 5-10 minutes of rainfall to the rainfall duration was calculated larger than the value using the standard rainfall intensity equation, which would result in an over-design of 10% to 30%. In the case of a relatively long rainfall duration of 360 minutes (6 hours) to 1,440 minutes (24 hours), it showed an lower rainfall intensity of 60 to 90% in the early stages of rainfall, but the problem of under-design had been solved as the rainfall duration time had elapsed. On the other hand, in the alternating block method (ABM) method, it was found that the rainfall intensity at the entire period at each assumed rainfall duration accurately matched the standard rainfall intensity hyetograph of Seoul.

A Study on the Standard Working Area by Somatometria (인체계측(人體計測)에 의(依)한 표준작업역(標準作業域)의 연구(硏究))

  • Lee, Sang-Do;Jeong, Jung-Hui
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.2 no.1
    • /
    • pp.61-78
    • /
    • 1976
  • The purpose of this study is to establish the horizontal and vertical working area which is dependent on measuring value of workers, body in order to make easy and stable working environments, and then to design the size of machines, tools and instruments in production factory because of making the practical production conditions which is the most suitable to human characteristics. But there is necessity that we have to review numeric value of measurement periodically because the size of workers' body is variable according to periodic and social circumstances. The establishment of standard working area after measurement enable us to make the best working conditions and we can design standard working table, optimum size of all machines and tools in production activity. Therefore, we can also acknowledge the importance of studying on human engineering because human engineering is necessary to reduction of fatigue in working, saving workers from industrial accidents, fail-safe system, improvement of productivity with increase in efficiency and etc. Finally, this study informs us that numeric value of measurement is larger than that of Japan, but not than that of America and Germany. So we can establish standard working area which is the most suitable for Korean inherence after measurement of detailed parts for workers' body.

  • PDF

Changes in the Standardized Uptake Value According to the Type of Metal of Dental Prosthesis in PET-CT Fusion Image (PET-CT 융합 영상에서 치과보철물의 금속 종류에 따른 표준섭취계수 값의 변화)

  • Han, Sang-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.9
    • /
    • pp.117-122
    • /
    • 2018
  • In this study, HU(hounsfield unit) value of CT generated by dental prosthesis was measured according to the type of metal when PET-CT was performed, and the degree of distortion and standard deviation of SUV(standard uptake value) and to propose a method to reduce errors in image reading. PET-CT was performed using actual teeth, metal crown, gold crown, titanium, and zirconia dental prosthesis. Compared with general teeth, the SUV value increased with increasing HU value. The SUV value of metal crown, titanium, and zirconia was increased by 37% and the gold crown increased by 45.4%. In addition, image distortions were small in general teeth, metal crown, titanium, and zirconia, but hard curing of the gold crown occurred and image distortion occurred. Therefore, since the metal type of the dental prosthesis affects the SUV value, the NAC(non attenuation correction) PET image of the dental prosthesis can be helpful in the diagnosis of the patient using the gold material.

KOMPSAT-1 EOC 표준영상 처리

  • Jun, Jung-Nam;Kim, Youn-Soo
    • Aerospace Engineering and Technology
    • /
    • v.2 no.1
    • /
    • pp.197-204
    • /
    • 2003
  • General image processing is the production of images of added value with the use of the original and standard images. Generated data and auxiliary data are backed up and this retrieved data is periodically updated to provide images to outside users. To product general images, makes use of EOC Processing System Software. And then added value images is made from the standard images. Standard and added images are possible with internet for search and promptly provides for user. The process of the standard image derived from the original image(received from the satellite) is systematically arranged in this thesis, which also contains a concise explanation of the EOC processing system.

  • PDF

A Case of the Distribution Power System PQMS Construction & Harmonic Voltage Analysis (배전계통 PQM 시스템 구축 및 고조파전압 분석사례)

  • Park, Yong-Up;Lee, Keon-Hang
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.24 no.9
    • /
    • pp.108-117
    • /
    • 2010
  • The main contents of this paper are the PQM system construction case and distribution system harmonic voltage analysis. The PQM system has constructed by KEPCO in order to investigate power quality of distribution power system for new power quality standard of KEPCO. In result, we have confirmed that voltage harmonic measurement value of the high voltage contract customer 8 households is suitable the KEPCO harmonic standard tentative plan. And the voltage harmonic value of distribution line end side is not always more high than source side by harmonic current offset effect. In the future, acquired data by season, region, load from the PQMS will be used on the resonable harmonic standard enactment in KEPCO.

Design standard for fairway in next generation

  • Ohtsu, Kohei;Yoshimura, Yasuo;Hirano, Masayoshi;Takahashi, Hironao;Tsugane, Masanori;Ohtsu, Kohei
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2006.10a
    • /
    • pp.230-239
    • /
    • 2006
  • The depth, width and alignment of fairway that are main port water facilities should be designed considering the various elements including particulars of design ships, weather and sea conditions around fairway and method of ship-handling. However not only the existing Japanese design standard for fairway and also those of other countries do not take into consideration of such kind of elements and no design standard is made by quantitative analysis. In this circumstance the new design standard (Approach Channels, A Guide for Design) depending on classified various elements and quantitative analysis was proposed in 1997 by PIANC and IAPH. But it was proved that calculated values according to this standard were unfounded and had some problems to output the discontinuous value by small difference of calculation condition because the each value fur each element was simply added. And also it is hard to apply this standard to the design of port water facilities in Japan because this [A Guide for Design] is the design standard for long channels in European port. The proposal of more reasonable Japanese standard will be expected by applying the study result of naval architecture and navigation and by the cooperation of ship operators to use fairway, naval architects to built ships and civil engineers to dredge fairway. The concept of a fairway in 'Design standard fur fairway in next generation' is defined as passage for approach channel) and traffic lane designated by light buoys as navigable water for safe navigation. In 'Design standard for fairway in next generation' depth, width and alignment are picked up among many design elements of a fairway. Design method for those elements is shown based on design ships and navigational environments. This standard shows the method of design for each dimension depending on characteristic on design ship and weather and sea condition. On the other hand, in case of existing fairway, it is possible to decide the size of ship and navigation criteria by opposite analysis.

  • PDF

Comparison of Formaldehyde Emission of Wood-based Panels with Different Adhesive-hardener Combinations by Gas Chromatography and Standard Methods

  • Eom, Young Geun;Kim, Sumin;Baek, In-Chan;Kim, Hyun-Joong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.33 no.2 s.130
    • /
    • pp.29-39
    • /
    • 2005
  • Formaldehyde emissions from wood-based panels bonded with pine and wattle tannin-based adhesives, urea-formaldehyde resin (UF), melamine-formaldehyde resin (MF), and co-polycondensed resin of urea-melamine-formaldehyde (UMF) were measured by the Japanese standard method using a desiccator (JIS A 1460) and the EN 120 (European Committee For Standardization, 1991) method using the perforator value. In formaldehyde emission, all particleboards made using the wattle tannin-based adhesive with three different hardeners, paraformaldehyde, hexamethylenetetramine, and tris(hydroxyl)nitromethan (TN), satisfied the requirements of grade $E_1$. But only those made using the pine tannin-based adhesive with the hexamine as hardener met the grade $E_1$ requirements. Hexamine was effective in reducing formaldehyde emission in tannin-based adhesives when used as the hardener. While the UF resin showed a desiccator value of $7.1mg/{\ell}$ and a perforator value of 12.1 mg/100 g, the MF resin exhibited a desiccator value of $0.6mg/{\ell}$ and a perforator value of 2.9 mg/100 g. According to the Japanese Industrial Standard and the European Standard, the formaldehyde emission level of the MDF panels made with UF resin in this study came under grade $E_2$. The formaldehyde emission level was dramatically reduced by the addition of MF resin. The desiccator and perforator methods produced proportionally equivalent results. Gas chromatography, a more sensitive and advanced method, was also used. The samples for gas chromatography were gathered during the experiment involving the perforator method. The formaldehyde contents measured by gas chromatography were directly proportional to the perforator values.