• Title/Summary/Keyword: Standard time

Search Result 8,333, Processing Time 0.036 seconds

Comparison of Accuracy and Output Waveform of Devices According to Rectification Method (정류방식에 따른 장치의 정확도와 출력 파형의 비교)

  • Lee, In Ja
    • Journal of radiological science and technology
    • /
    • v.41 no.6
    • /
    • pp.603-610
    • /
    • 2018
  • This study examined the following: accuracy of the exposure conditions in the inverter device and three-phase device; output waveform over the exposure conditions; and average and standard deviation of the output waveform. After assessing whether the dose corresponding to the theoretical dose was presented, the following conclusions were obtained: 1. The accuracy of the tube voltage(kVp) and tube current(mA) exposure time(sec) was within the tolerable level prescribed in Korea's Safety Management Standards. In the error, Inverter device was large the tube voltage and exposure time, the three-phase device was large the tube current. 2. In terms of the output waveform of the exposure conditions and the average and standard deviation of the output waveform, the higher tube voltage and larger tube current resulted in greater standard deviation in pulsation. Moreover, the standard deviation of pulsation was shown to be greater in the inverter device than the three-phase device; there was also greater standard deviation in the inverter device considering the exposure time. 3. Regarding the exposure conditions over the output dose, all linearity showed the coefficient of variation which had an allowable limit of error within 0.05. Although the output dose ratio for the inverter device was 1.00~1.10 times no difference that of the three-phase device, there was almost no difference in dose ratio between the tube currents.

Time-resolved transient reflective image on silicon surface after single-shot fs-laser pulse irradiation (단일 펨토초 레이저펄스를 이용한 실리콘 표면에서의 시분해 반사율 측정 연구)

  • Moon, Heh-Young;Sidhu, Mehra Singh;Lee, Hyun-Kyu;Jeoung, Sae-Chae
    • Laser Solutions
    • /
    • v.14 no.4
    • /
    • pp.21-27
    • /
    • 2011
  • In this work, we have studied on time-resolved transient reflective image of single crystalline Si surface after single-shot fs-laser irradiation with varying the laser fluence under two different laser spot sizes. The temporal profiles of transient reflectivity changes as well as its maximum values at the early delay time were found to be strongly dependent on both the laser beam spot size and laser fluence. We have interpreted the dependence of transient reflectivity changes on the laser spot size in terms of a relaxation of the generated free carriers to the bulk silicon, which should be interacted with the plasma.

  • PDF

The Design and Implementation of EL/LX level3 C Standard Library for RTOS Qplus-P (EL/IX 단계 3을 적용한 실시간 운영체제 Qplus-P용 C 표준 라이브러리의 설계 및 구현)

  • Kim, Do-Hyung;Shin, Chang-Min;Park, Sung-Min
    • The KIPS Transactions:PartA
    • /
    • v.9A no.4
    • /
    • pp.485-490
    • /
    • 2002
  • As the products of internet appliance, such as digital TV, internet set-top box, and internet phone, are continually produced, the market of real time operating system which controls those products is being highly increased. ETRI developed the extensible real time operating system, Qplus-P, which can be used from PDA to internet set-top box and home server. This paper describes the design and implementation of C standard library for real-time operating system Qplus-P. The Qplus-P C standard library follows EL/IX API level, which is proposed to the real-time operating system international standard by the RedHat. And, the C standard library functions, which are needed to support the Tiny-X and Kaffe, are also implemented. The implemented C standard library can reduce the size of library about 30% compare to the C library that does not follow EL/IX API level.

Work Measurement of Dietetic Staff through Work Sampling Methodology in School Foodservice Systems (워크샘플링에 의한 학교급식 전담직원의 직무분석)

  • 양일선;이영은;차진아;유태용;정라나
    • Journal of Nutrition and Health
    • /
    • v.35 no.2
    • /
    • pp.263-271
    • /
    • 2002
  • The purpose of this study was to determine the standard work time of dietetic staff through work sampling methodology in school flood service systems. Work measurement through work sampling methodology was conducted in five conventional, five commissary and five joint management flood service systems over two consecutive weeks in October 1999. Statistical analysis was performed on the SAS/Win 6.12 package program for Kruskal-Wallis test and multiple comparison. Observed data were satisfied with a confidence level of 95% and a confidence interval of $\pm$ 0.05. The results of this study can be summarized as follows. The actual time spent by dietetic staff members in conventional, commissary, joint-management flood servile systems was 2,394, 2,521 and 2,110 minutes per week, respectively. Transportation time of each flood service systeml and ILO allowance rate (11%) was applied. Thus, the standard work time per week of dietetic staff members in conventional, commissary, joint-management flood service systems was 2,746.14, 2,861.58 and 2,520.81 minutes, respectively. The standardized index was 1.04, 1.08 and 0.95 men in conventional, commissary, and joint-management flood service systems, respectively. Regardless of the school flood service system, those with "the duty of cooking and distribution management" had the longest labor time, while those with "duty of nutritional education" had the shortest labor time.

A Study on the Method and Work Measurement for Productivity Improvement of Clothing Products-With concentration in MTM Analysis- (의류제품의 생산성 향상을 위한 방법 및 작업측정에 관한 연구-MTM법을 중심으로-)

  • 김옥경;이순흥
    • Journal of the Korean Society of Costume
    • /
    • v.41
    • /
    • pp.185-206
    • /
    • 1998
  • The purpose of this study was to improve productivity for maximum effects with the present equipments and staff. This study compared and analyzed the mea-sured time by using stop watch method and MTM, which was the new measuring method. The flow and results of this study were as follows: 1. This study investigated the theoretical background the efficiency for production management, and the way of productivity improvement through documentary research. 2. Setting up the standard flow on the experi-mental company production, making out a process chart and measuring the actual working hour. 3. The study measured the allowance time applying work sampling. 4. Each process of the movement analysis was filmed by video to use basic data. 5. MTM analysis was taken by choosing 10 processes from front bodice according to the basic movement of MTM. Through the results, this study exclude unneccesary movements and suggest a method for working ways. 6. Using the actual working hour measured by a stop watch calculated the pitch time and presumed the amount of daily productivity. 7. The result of the work sampling came out as 38% of allowance rate. It was 13% higher than the standard amount of woman's jacket allowance rate, which was 25%. The most influencing factor was work discussion. That was because there were commuication problem of the work way between the operator and leader. More adequate use of flow table and level passing table was needed. There were the problems that inappropriate places and sizes made the distance of movements longer and often needed more adjustment of works and surroundings. To prevent breakdowns equipments check ups were necessary before works. 8. The results of MTM analysis were as follow : the time was reduced 40% than the actual measured time by a stop watch. This was because the leveling of the operator was included in the real calculation. Also, leveling was included in MTM analysis and all the conditions were standarized. Therefore MTM method was a scientidic measuring way of establishing the standard time. The presented method of this study, suggested an ideal method eliminating unneccesary motions, and presented standardization of works. Improvement of working methods, work condition and simplifying motions in each 10 processes reduced the working time from total 656 seconds to 301 seconds. 9. The way and time of working was linked together in the MTM analysis methods. Thus data from MTM help suggest not only establishing standard time but also establishing stan-dard work. Plus it includes various ability for improvements of working ways. So it is an objective method which can be widely used in other work studies. 10. The function of a time study is to determine the amount of work produced with a given method. The work rate is used to establish the cost of labor. The wage of worker must be calculated per unit time which is deter-mined before the time study is made. This study tried to introduce the incentive rule for deciding wages according to the standard time by MTM method.

  • PDF

A State Standard and Policy Quality Control (기술사마당 - 국격과 정책품질관리(國格과 政策品質管理))

  • Jung, Byeong Hyun
    • Journal of the Korean Professional Engineers Association
    • /
    • v.46 no.1
    • /
    • pp.58-63
    • /
    • 2013
  • Since 2010, politicians and netizens have been frequently talking about "The Standard of a Nation". Specification/Standard contains "de facto standard" and "de jure standard". "The Standard of a Nation", the level of a state's quality, is prescribed by the constitution. Though the constitution, which is equal to a state's official standard, has been well established, it would be undervalued without civil obedience. The state standard can never be improved by a couple of successful projects or some national policies. The time is that the people who would like to level up of the state standard also should consider technology and science as important.

  • PDF

Building a Rule-Based Goal-Model from the IEC 62304 Standard for Medical Device Software

  • Kim, DongYeop;Lee, Byungjeong;Lee, Jung-Won
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.13 no.8
    • /
    • pp.4174-4190
    • /
    • 2019
  • IEC 62304 is a standard for the medical device software lifecycle. Developers must develop software that complies with all specifications in the standard for licensing. However, because the standard contains not only a large number of specifications, but also domain-specific information and association relationships between specifications, it requires considerable effort and time for developers to understand and interpret the standard. To support developers, this paper presents a method for extracting the contents of the IEC 62304 standard as a goal model, which is the core methodologies of requirements engineering. The proposed method analyzes the grammar of the standard to robustly extract complex structures and various information from standard specifications and define rules that extract goals and links from syntactic element units. We validated the actual extraction process for the standard document experimentally. Based on the extracted goal model, developers can intuitively and efficiently comply with the standard and track specific information within the medical software and standard domains.

A study on the development of standard-time receiving device for process computer (공정용 컴퓨터를 위한 표준시각 수신장치 개발에 관한 연구)

  • 홍용표;손창호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.385-389
    • /
    • 1988
  • PCS(Process Computer System) is installed to monitor various kinds of process parameters in Power Plant and networked for synthetic monitor and event analysis in all site. But when an event is occured sequentially or simultaneously among the plants, it is difficult to analyze it because of different Stardard-Time in each plant. Standard-Time Receiving Device is developed to solve this problem and development procedure is described here.

  • PDF

Development of Standard Model for Traditional Pavilion (전통정자의 표준모델 개발)

  • Hong, Kwang-pyo;Sim, Daesup;LEE, Hyukjae
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.2
    • /
    • pp.387-395
    • /
    • 2020
  • The standard model of Korean pavilions can embody the beauty of the Korean traditional and reflect the trend of the times, develop a universal and realistic model, and at the same time promote Korean traditional beauty internationally. Therefore, the purpose of this study is to develop a standard model for living, industrializing, activating and globalizing Korean traditional pavilions while inheriting our own traditional technologies and preserving the legitimacy of Korean pavilions through a case study of Korean traditional pavilions. Considering the case analysis and modern trends, the plan was carried out in each part to present standard models for the representative types of traditional pavilion, Samojeong, Yukgakjeong, and Palgakjeong. The standard model has made some changes in design trends, including the installation of handrails and handrails to enhance utilization while considering legitimacy. The standard model presented in this way reflects the current design trend and can be changed in different forms depending on the trend at that time. The standard model of Korean pavilions developed this time can be said to be a universal and realistic model, while reproducing the beauty of Korean tradition.

The Comparative Study on Decoctions of Yukmijihwang-tang (Liuweidihuang-tang) Extracted by Different Extraction Method and Extraction Time (전탕 방법 및 전탕 시간에 따른 육미지황탕 전탕액 비교 연구)

  • Kim, Jung-Hoon;Seo, Chang-Seob;Jeon, Woo-Young;Shin, Hyeun-Kyoo
    • Herbal Formula Science
    • /
    • v.19 no.1
    • /
    • pp.175-182
    • /
    • 2011
  • Objectives : This study was performed to compare the differences between decoctions extracted by different extraction method and extraction time. Methods : Decoctions were prepared with pressed or non-pressed extraction conditions for 60, 120 and 180min. The yields of extracts, sugar contents, hydrogen ion concentrations(pH), the contents of reference compounds in Yukmijihwang-tang(Liuweidihuang-tang) were investigated. Results : The yields and the dissolved solid content containing sugar content of decoctions were more in pressed extraction method than unpressed extraction method, and they tended to be increased as extraction time increased. The pH values of decoctions methods did not show significant differences between pressed and unpressed extraction methods or extraction times. Most of reference compounds showed higher contents in pressed extraction method than unpressed extraction method and their contents were augmented according to increase of extraction time. The content of paeonol was decreased when extracted in more than 120min with pressed extraction method and tended to be decreased as extraction time increased in unpressed extraction method. Conclusions : The pressed extraction with long extraction time could be useful for decoction of Yukmijihwang-tang(Liuweidihuang-tang). However, another ingredients possible to decrease in such condition need to be considered to determine suitable extraction condition.