• 제목/요약/키워드: Standard solution

검색결과 1,929건 처리시간 0.028초

토양용액 채취를 위한 토성별 한계수분함량 설정 (Determination of moisture threshold for solution sampling in different soil texture)

  • 이창훈;김명숙;공명석;김유학;오택근;강성수
    • 농업과학연구
    • /
    • 제41권4호
    • /
    • pp.399-404
    • /
    • 2014
  • Soil moisture is an important factor for the availability and circulation of nutrients in arable soil. The purpose of this study was to set thresholds moisture content on soil nitrate concentration in the solution for real-time diagnosis. Sandy loam, silt loam, and sandy loam was filled with $1.2g\;cm^{-3}$ at Wagner pots, 0, 100, and $200mg\;L^{-1}$ of $KNO_3$ was saturated. Nitrate in standard solution was recovered about 95% by passing the porous cup. Nitrate concentrations in sampling of soil solution were examined by using a porous cup. The soil solution was higher in accordance with sandy loam> silt loam> clay loam, limited water filled pore space for sampling soil solution was 33.7, 56.4, and 62.2%, respectively. Nitrate concentration in the soil solution was negligible at sandy loam and silt loam during sampling periods, which was decreased about 50~82% in clay loam compared to the initial $NO_3$-N concentration in the saturated $KNO_3$ solution. Over limitation of soil solution sampling, soil EC and $NO_3$-N content were increased with the saturated $NO_3$-N concentration, regardless of soil texture (p<0.05). Conclusively, soil solution by using a porous cup was possible, regardless of the soil texture, which was useful for the diagnosis in nitrate concentration of soil solution. However, because nitrate concentration of soil solution in a clay loam changes, it was necessary for careful attention in order to take advantage for the real-time diagnosis of nitrogen management in soil.

Filter Hybridization과 Solution Hybridization 방법에 의한 백서 Surfactant Protein C mRNA 정량측정의 비교 (Comparative Quantitative Study of Surfactant Protein C mRNA by Filter Hybridization and Solution Hybridization in Rats)

  • 김진호;손장원;양석철;윤호주;신동호;박성수
    • Tuberculosis and Respiratory Diseases
    • /
    • 제51권6호
    • /
    • pp.517-529
    • /
    • 2001
  • 연구배경 : Filter hybridization이나 solution hybridization 방법들은 Northern blot나 slot blot에 비하여 빠르며 재현성이 높고 소량의 RNA를 측정할 수 있으며 한꺼번에 많은 시료들을 동시에 측정하는것이 가능하다. 방 법 : 저자들은 쥐를 대상으로 하여 SP-C mRNA를 filter hybridization과 solution hybridization 방법들로 각각 정량측정하여 방법론에 따른 분자생물학적 정도관리에 대한 관찰을 하기 위하여 이 연구를 시행하였다. 결 과 : 1) Solution hybridization 방법에 의한 SP-C mRNA의 정량측정을 위한 RNA 검체물의 최소량은 3pg 이상이었다. 2) Solution hybridization에 쓰이는 SP-C sense mRN A input 양과 유전자 cpm과의 Y=6.46 X+244(X=SP-C mRNA 전사체 Y=cpm)였고, 양자간의 상관계수 r은 0.99로 매우 밀접한 상관성을 보였다. 3) Filter hybridization방법에 의한 SP-C mRNA의 정량측정을 위한 RNA검체물의 최소량은 0.1ng 이상이었다. 4) SP-C의 sense 전사체 0, 0.1, 0.5, 1.0, 2.5 및 5 ng에 대한 cpm과의 표준곡선은 Y=2541.6 X+252.7 (X=SP-C mRNA 전사체 Y=CPM) 이고 상관계수 r은 0.99로 매우 밀접한 상관성을 보였다. 결 론 : Solution hybridization 방법은 다른 방법에 비해 RNA input 양을 아주 소량 사용하면서도 주위에 높은 배후 방사성 산란을 보이는 비특이성 DNA가 있음에도 불구하고 특정 시료의 양이 한정되어 있는 상황에서 RNA를 분석 검토하는데 매우 유용한 연구방법이며, 뿐만아니라 filter hybridization 방법은 mRNA를 정량 측정하는데 있어서 신속하고 재현성이 높으며, 한꺼번에 많은 시료들을 시행할 수 있고, 사료의 mRNA를 정량측정 하는데 있어서 유용한 방법임을 알 수 있었다.

  • PDF

pH 측정의 숙련도 시험에 대한 연구 (A Study on the proficiency test of pH measurements)

  • 이화심;김명수;최종오
    • 분석과학
    • /
    • 제14권3호
    • /
    • pp.230-237
    • /
    • 2001
  • 일반적인 pH의 측정은 유리전극을 사용한 pH 측정기를 pH 표준용액으로 검정한 다음, 시료용액의 pH를 측정하는 절차를 따른다. 일정 온도의 pH 측정에서 불확도에 영향을 미치는 인자는 pH 표준용액의 불확도와 유리전극의 정확도 및 재현성이라 할 수 있다. 본 연구에서는 실제로 동일한 시료에 대해 각 실험실에서 측정하고 있는 pH 측정값이 어떠한 분포를 보이며, 오차 발생 시 주된 요인이 무엇인지를 알기 위해 pH 표준용액 시료를 사용하여 자원하는 국내의 실험실을 대상으로 98, 99년에 걸쳐 숙련도 시험을 실시하였다. 숙련도 시험 시료는 $25^{\circ}C$에서 pH 6.860, 7.415의 값을 가지는 인산염 표준용액을 제조하여 사용하였고, 숙련도 시험 기간내의 안정도 여부를 확인하기 위해 안정도 시험을 실시하였다. 숙련도 시험 결과를 Youden plot하여 측정 결과의 오차가 우연효과에 의한 것인지 계통효과에 의한 것인지를 파악하였을 때, 두 해 모두 오차를 갖는 실험실들이 계통효과에 의한 오차만을 나타내었다. 이는 각 실험실에서 사용하고 있는 표준용액이 오차의 원인임을 말해 주고 있다.

  • PDF

N-P-K 양분 수준이 토마토의 오존 감수성에 미치는 영향 (Influence of N-P-K Nutrient Levels on Ozone Susceptibility of Tomato Plants)

  • 안주원;구자형
    • 한국환경농학회지
    • /
    • 제17권4호
    • /
    • pp.352-357
    • /
    • 1998
  • 양액조성의 차이에 따른 토마토의 오존 감수성을 구명하고자 1/2농도의 Hoagland 용액을 표준으로 하여 양액을 조성하였다. N-P-K의 수준을 $N_{100}$ $P_{100}$ $K_{100}$(대조구), $N_{47}$ $P_{100}$ $K_{100}$(질소 감량구), $N_{93}$ $P_0$ $K_{100}$(인산 제거구), $N_{100}$ $P_{100}$ $K_0$(칼륨 제거구), $N_{153}$ $P_{100}$ $K_{100}$(질소 중량구), $N_{107}$ $P_{200}$ $K_{100}$(인산 2배구), $N_{140}$ $P_{100}$ $K_{200}$(칼륨 2배구) 등으로 나누어 수경재배한 후 $0.25{\mu}l/L$의 오존에 접촉시킨 결과 다음과 같은 결론을 얻었다. 1. 지상부 생육은 질소 감량구와 인산 제거구에서 가장 저조하였고, 인산 및 갈륨 제거구에서 인산가 칼륨의 엽중함량이 극히 낮았다. 시비수준의 차이에 따른 가시피해율은 칼륨 제거구에서 가장 심하게 나타났다. 인산 제거구, 질소 감량구 및 중량구 또는 인산과 칼륨 2배구의 피해율은 표준구와 비슷한 경향을 보였다. 2. 오존접촉 후 칼륨 제거구에서 다른 처리구에 비하여 ethylene발생량, 전해질 유출량과 MDA함량이 증가하였으며 엽록소의 함량은 크게 감소였다. 3. 가시피해가 가장 심했던 칼륨 제거구에서 SOD의 활성이 가장 낮았으며 오존접촉 후에도 활성 증가율이 가장 낮게 유지되었다.

  • PDF

국내산 상지(桑枝)의 품질관리 연구 (Studies on quality control of domestic Morus alba Linne)

  • 박유미;백미은;이영종;원재희
    • 대한본초학회지
    • /
    • 제31권3호
    • /
    • pp.71-75
    • /
    • 2016
  • Objectives : Mori Ramulus is a young branch of Morus alba Linne, which has been used as traditional medicines for antidiarrhea, antibacteria, and antihypertension in Korea. With the basis on these medicinal activities, it is registered at the Korean Herbal Pharmacopoeia. The standard for quality control in use, however, is not yet validated.Methods : We experiment on heavy metals test, TLC, loss on drying, ash, acid-insoluble ash, contents of ethanolsoluble extracts and contents of oxyresveratrol by using the 15 samples of Mori Ramulus which are collected domestically. We tested items according to the General Test, processes and apparatus, Crude Drugs Test of KP(2011).Results : Purity test(Heavy metals) showed contents for Pb, As, Hg, and Cd range of 0.1~1.1 ppm, 0.0~0.2 ppm, 0.00~0.01 ppm, and 0.00~0.02 ppm. Identification test(Thin layer chromatography) was on comparing with morucine standard solution in Rf value, all samples showed morucine spot (dark blue, Rf : 0.3) as same as Rf value of morucine-standard solution. Loss on drying was ranged from 5.1 to 8.9 %, ash and acid-insoluble ash were between the range 3.0~6.3% and 0.3~0.8%. Contents of ethanol-soluble extracts was ranged from 6.2 to 12.0%. Content of oxyresveratrol was ranged from 0.01 to 0.16 % based on the oxyresveratrol standard curve.Conclusions : We sincerely hope that this study will be contributed to the standardization and quality control of Korean herbal medicines.

Functional Integration of Serial Dilution and Capillary Electrophoresis on a PDMS Microchip

  • Chang, Jun-Keun;Heo, Yun-Seok;Hyunwoo Bang;Keunchang Cho;Seok Chung;Chanil Chung;Han, Dong-Chul
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제8권4호
    • /
    • pp.233-239
    • /
    • 2003
  • For the quantitative analysis of an unknown sample a calibration curve should be obtained, as analytical instruments give relative, rather than absolute measurements. Therefore, researchers should make standard samples with various known concentrations, measure each standard and the unknown sample, and then determine the concentration of the unknown by comparing the measured value to those of the standards. These procedures are tedious and time-consuming. Therefore, we developed a polymer based microfluidic device from polydimethylsiloxane, which integrates serial dilution and capillary electrophoresis functions in a single device. The integrated microchip can provide a one-step analytical tool, and thus replace the complex experimental procedures. Two plastic syringes, one containing a buffer solution and the other a standard solution, were connected to two inlet holes on a microchip, and pushed by a hydrodynamic force. The standard sample is serially diluted to various concentrations through the microfluidic networks. The diluted samples are sequentially introduced through microchannels by electro-osmotic force, and their laser-induced fluorescence signals measured by capillary electrophoresis. We demonstrate the integrated microchip performance by measuring the fluorescence signals of fluorescein at various concentrations. The calibration curve obtained from the electropherograms showed the expected linearity.

유도결합 플라즈마 발광분광기의 매트릭스 보정법에 의한 구리 중납, 카드뮴 및 크롬 분석에 관한 연구 (The Study on Analytical Method of Lead, Cadmium and Chromium in Copper Metal by Matrix Matching Method of Inductively Coupled Plasma Atomic Emission Spectrometer)

  • 주성균;김준;정남용;임규철;최영환;김상경
    • 대한화학회지
    • /
    • 제53권3호
    • /
    • pp.293-301
    • /
    • 2009
  • 일정 농도의 Pb, Cd 및 Cr이 첨가된 합성 Cu표준시료용액 (RMs)을 ICP로 여러 파장에서 Cu매트릭스 미 보정 검정곡선에 준하여 분석한 결과 모든 원소가 전 파장에서 Cu매트릭스의 영향을 받아 정확도 (Pb 140$\sim$1 090%)가 떨어졌다. Pb, Cd 및 Cr의 각각 일정 농도에 Cu의 농도를 변화시켜 분석한 결과 Cu 0.05 wt/v % (0.05 g/100 mL) 이상을 함유하면 실제 Pb, Cd 및 Cr이 첨가된 농도보다 Cu의 농도가 증가함에 따라 일정함수의 비로 감소하거나 증가하여 Cu매트릭스의 영향이 심함을 볼 수 있었다. Cu매트릭스 보정법에 의한 합성 Cu표준시료용액 (RMs)을 분석한 결과 99.9% 이상의 정확도를 보여주었다.

EV 충전인프라를 위한 국제표준에 부합하는 V2G용 전력선통신모듈 설계 및 응용 (Design and Application of Power Line Communication Module for V2G Conforming with International Standard for Electric Vehicle Charging Infrastructure)

  • 김철수;백수황
    • 한국전자통신학회논문지
    • /
    • 제13권6호
    • /
    • pp.1183-1190
    • /
    • 2018
  • 전 세계적으로 환경규제가 지속적으로 강화되고 있으며 이에 효과적으로 대응하기 위해 전기자동차의 도입이 적극적으로 고려되고 있으며, EV 보급의 필수요소인 충전인프라 구축이 필수적이다. 본 논문에서는 스마트한 충전인프라 구축에 필수적인 전력선 통신 기술에 대하여 연구하였다. ISO/IEC 15118 국제표준에 부합한 HPGP규격의 물리계층 속도 10Mbps 및 TCP/IP계층 4.5Mbps 성능을 달성할 수 있는 제어보드와 해당 보드에 탑재되어 국제표준에 부합하는 충전단계 및 향후 지능형전력망과의 연계를 위한 기능을 수행할 소프트웨어 솔루션을 개발하였다. 또한 Combo 방식의 DC 급속충전기에 적용하기 위해 산업 환경 기준에 적합하도록 하드웨어를 설계하였으며 소프트웨어 솔루션과 함께 통합하여 V2G 통신 모듈을 개발하였다.

수경배양액 무기성분농도 측정장치 개발 (Equipment Development for Inorganic-Compound Concentration Measurement in a Hydroponic Culture Solution)

  • 허정욱;박경훈;홍승길;이재수;백정현;박종택;이승기
    • 한국환경농학회지
    • /
    • 제39권4호
    • /
    • pp.319-326
    • /
    • 2020
  • BACKGROUND: Measurement equipment was developed for inorganic nutrient concentration inside the hydroponic culture medium with several macro- and micro compositions, and applied for measuring the compositions of conventional medium. METHODS AND RESULTS: Before the equipment development, sonicator and heater were utilized to control temperature around of the module mixing with color reagents and target samples among the inorganic compositions. The measurement module and multi-sampler were also manufactured based on the COMS (Complementary Metal-Oxide Semiconductor) and installed inside the measurement equipment. Concentration of standard solution, value measured by the equipment, standard deviation or measured average value were used for estimating the accuracy and average recall of the equipment. Yamazaki solutions with EC of 0.5, 1.5, and 2.5 dS/m were offered to confirm the equipment accuracy and standard error. CONCLUSION: It was suggested that the developed equipment could be automatically applied for measurement with accuracy of over 96% and standard errors of less than 5% on 12 macro- and micro compositions such as a NO3-N, PO43- or Fe.

사과와 토양 중에서 Difenoconazole의 잔류성에 대한 기체 크로마토그래피 분석 (Gas Chromatographic Analysis on Residual Difenoconazole in Apple and Soil)

  • 한성수;김일광
    • 분석과학
    • /
    • 제9권2호
    • /
    • pp.123-133
    • /
    • 1996
  • 기체 크로마토그래피법을 이용하여 과수 재배용 살균제인 difenoconazole의 분석을 위한 최적 조건을 구하고, 사과와 토양 중에서의 잔류성을 조사하였다. 사과사료는 5% NaCl과 n-hexane액으로 분리, 농축하여 florisil column상에서 acetone과 n-hexane 혼합액으로 정제하여 GLC(ECD)로 분석하였다. 0.20과 1.0ppm의 표준물 첨가실험결과 평균회수율은 86.0~92.0% 였고, 검출한계는 0.01ppm 이었다. 사과에 대한 안정 사용기간은 수확 15일 전 3회 사용이 적당한 것으로 나타났으며, 이 경우 difenoconazole의 잔류량은 0.037ppm에서 0.044ppm 이었다. 토양시료를 methanol과 ammonium hydroxide 의 혼합액으로 추출하여 여과한 후 포화 NaCl 용액과 dichloromethane층으로 분배하였다. 유기층을 농축하여 toluene 용매로 재용해하였고, Sep-Pak column으로 정제한 후 GLC(FID)로 분석하였다. 0.10, 0.50과 1.0ppm 표준물 첨가실험 결과 평균 회수율은 101.2~103.7% 였고, 검출한계는 0.025ppm 이었다.

  • PDF