• Title/Summary/Keyword: Standard pattern

Search Result 1,488, Processing Time 0.025 seconds

Development of a Bodice Prototype Drafting Method for 20s Obesity Males using 3D Simulation

  • Cha, Su-Joung
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.6
    • /
    • pp.95-107
    • /
    • 2022
  • This study attempted to develop a bodice prototype suitable for the 20's obese male's trunk with a BMI of 25kg/m2 or more, which is distinguished from the standard body type. Through this, it was intended to provide data to help the development of clothing for obese males. Patterns such as front bodice shoulder line and front sagging were modified through primary appearance and garment pressure evaluation. Through the second evaluation, corrections such as back armhole, back waistline, and front sagging were performed. Through the third evaluation, the final pattern drafting method was developed by removing the front sagging added through the second evaluation. In the case of obese male body types in their 20s, a drafting method distinguished from the standard body type was required in the method of setting the front and back waist lines, back armhole darts, and front shoulder lines due to protruding and posture of the abdomen. This study was meaningful in that it presented a bodice prototype drafting method suitable for the 20s obese males. In the follow-up study, it is thought that actual clothing experiments and studies to develop clothing patterns by applying them to obese male tops in their 20s should be conducted.

Comparative accuracy of implant impression techniques with different splinting materials (임플란트 인상채득 방법과 인상용 코핑 연결 고정에 따른 정확성 비교)

  • Ki-Yoon Hong;Soo-Yeon Shin
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.39 no.1
    • /
    • pp.9-20
    • /
    • 2023
  • Purpose: We investigated the effect of open tray impression using pick-up impression coping and close tray impression using transfer impression coping on the accuracy of impression in edentulous patients on their mandibular parts. the effect of material types of pick-up type impression copings for splinting in open tray impression on the accuracy of impression was also evaluated. Materials and Methods: Two implant fixtures were implanted in parallel in the left molar of the mandibular in the shape of a mandibular partial edentulous model. The 40 individual trays were fabricated using 3D printer. The prepared individual trays were classified into 4 groups (i.e., PN, PG, PH, and TN groups), and a total of 40 impression-takings were conducted. A master cast was connected to a Scan Body. The converted STL file was super-imposed on the scan images of the various groups. Results: The order of standard deviation values decreased as follows: PN (0.2343 ± 0.0844 mm), TN (0.2192 ± 0.0840 mm), indicating that the high accuracy of impression for TN group. In addition, for the comparison results between the material types used in splinting the open tray impression, the PH group showed a relatively lower standard deviation (0.1910 ± 0.1176 mm) than that of the PN group (0.2343 ± 0.0844 mm), PG group (0.2556 ± 0.1082 mm). Conclusion: The acrylic resin synthesized by light-induced polymerization exhibited a higher accuracy of impression taking than that of autopolymerizing acrylic resin. Meanwhile, the accuracy of impression taking was not dependent on the implant impression taking method or the presence of connection/fixation of impression copings.

Persistence Study of Thiamethoxam and Its Metabolite in Kiwifruit for Establishment of Import Tolerance

  • Il Kyu Cho;Gyeong Hwan Lee;Woo Young Cho;Yun-Su Jeong;Danbi Kim;Kil Yong Kim;Gi-Woo Hyoung;Chul Hong Kim
    • Korean Journal of Environmental Agriculture
    • /
    • v.41 no.4
    • /
    • pp.355-364
    • /
    • 2022
  • BACKGROUND: Pre-harvest interval and decline pattern of thiamethoxam were determined in kiwifruit using liquid chromatography-tandem mass spectrometry (LCMS/MS). The study was carried out to propose import tolerance using OECD maximum residue limit (MRL) calculator for the export promotion of kiwifruit to Taiwan. METHODS AND RESULTS: The thiamethoxam residue in kiwifruit was determined by using the LC-TriQ-MS/MS with the analytical process to set up the import tolerance under greenhouse conditions for Taiwan. Excellent linearity was observed for all of the analytes with a determination coefficient (R2)≥0.99. The limit of quantification was determined to be 0.01 mg/kg for both thiamethoxam and clothianidin in kiwifruit. Linearity was determined from the co-efficient of determinants (R2) obtained from the seven-point calibration curve. The standard calibration curve showed as follows; 1) Site 1 (Gimje): y = 944,406X + 1,583 (R2=0.9995), 2) Site 2 (Goheung): y = 1,356,205X + 934 (R2=0.9983), and 3) Site 3 (Jangheung): y = 1,239,937X - 3,090 (R2=0.9908). The residue of thiamethoxam in the kiwifruit for three decline trials showed the range of 0.35 to 0.56 mg/kg in site 1 (Gimje), 0.24 to 0.55 mg/kg in site 2 (Goheung), and 0.28 to 0.42 mg/kg in site 3 (Jangheung), respectively. However, clothianidin was not detected in all of the treatments. The maximum residual amounts (decline) in the samples, sprayed according to the safe-use standard for thiamethoxam 10% WG in kiwifruit (30 days before harvest, 3 sprays every 7 days) were 0.56 mg/kg in site 1, 0.55 mg/kg in site 2, and 0.42 mg/kg in site 3, respectively. CONCLUSION(S): The import tolerance (IT) of thiamethoxam for kiwifruit may be proposed to be 0.9 mg/kg by using the OECD MRL calculator.

Unconfined Compressive Strength Characteristics of Eco-Friendly Stabilizers and Carbon Fiber Reinforced Soil (친환경고화재와 탄소섬유 보강토의 일축압축강도 특성)

  • Sewook Oh;Sunghwan Yang;Hongseok Kim
    • Journal of the Korean GEO-environmental Society
    • /
    • v.25 no.8
    • /
    • pp.13-19
    • /
    • 2024
  • In this study, to reinforce the surface layer of weathered soil slopes where erosion and collapse of surface layer occur, compression strength tests were conducted by mixing carbon fiber and eco-friendly stabilizer (E.S.B.) To determine the optimal mixing ratio of E.S.B. and carbon fiber, E.S.B. was set at conditions of 10%, 20%, and 30%, and carbon fiber at 0.3%, 0.6%, 0.9%, and 1.2%. Additionally, to analyze the changes in compressive strength according to dry density and curing period, 85% and 95% of the maximum dry unit weight were applied, and curing periods were set to 3 days, 7 days, and 28 days. The standard strength for surface layer reinforcement of slopes is proposed as 4 MPa at 7 days and 6 MPa at 28 days according to ACI 230.1R-09 (2009). The compression test results showed that the unconfined compressive strength of E.S.B. reinforced soil met the standard strength at an E.S.B. mixing ratio of 10% or more for 95% compaction. Moreover, when carbon fiber was mixed with E.S.B. reinforced soil, a ductile fracture pattern was observed after the yield point due to compressive strength, indicating that the mixture could compensate for post-yield failure. It was analyzed that the maximum strength is exhibited at a carbon fiber mixing ratio of 0.6%. The unconfined compressive strength of carbon fiber reinforced soil increases by approximately 54-70% compared to the condition without carbon fiber.

Quantitative Analysis of Feldspar Mixture Samples Using the Rietveld Refinement Method (Rietveld Refinement 방법을 응용한 장석 혼합시료의 정량분석 연구)

  • Shim, Sang-Heon;Ahn, Jung-Ho;Kim, Soo-Jin
    • Journal of the Mineralogical Society of Korea
    • /
    • v.7 no.1
    • /
    • pp.62-79
    • /
    • 1994
  • The quanttative and structural analysis of the binary standard mixtures of albite and quartz, and microcline and albite were carried out using the Rietveld refinement method in order to investigate the accuracy and precision of the method. The quantitative analysis using the Rietveld method results in a standard deviation of 4 wt % for the albite-quartz standard mixtures and 1 wt % for the microcline-albite standard mixtures, suggesting that its accuracy is far better than that of the conventional XRD method in which only a few selected peaks are utilized. Furthermore, the unit-cell parameters of component minerals in mixtures were also estimated accurately during the analysis. It was observed that the refined weight fractions deviate systematically from their measured values when the method is applied to the mixtures that contain minerals with different degrees of preferred orientation, such as albite-quartz mixtures. The preferred orientation parameters and R-values suggest that the systematic deviation is caused as a result of the preferred orientation effect of feldspar crystallites. It is evident that the preferred orientation corrections are of help for the accurate determination of unit-cell parameters, although they may not improve the result of quantitative analysis significantly. The refined weight fraction of the mineral with higher degree of preferred orientation in mixture is greater than the measured one. This is apparently caused by the effect of geometry of feldspar crystallites in the surface of the mounted sample. The Rietveld refinement method minimizes the problems inherent in the traditional XRD methods, such as the line overlap, primary extinction, and preferred orientation effect, by fitting every data point in a whole pattern explicitly. Furthermore, accurate unit-cell parameters as well as scale factors that can be obtained from the Rietveld refinement are used for the quqantification. The present stdudy demonstrates that the Rietveld method yields far more accurate analytical result than the conventional XRD quantitative analysis method does.

  • PDF

A Study on Leaching Characteristics of $Cr^{6+}$ in Cement Grout Materials (시멘트 그라우트재에서 $Cr^{6+}$용출특성에 관한 연구)

  • 김동우;이재영;천병식
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.2
    • /
    • pp.62-69
    • /
    • 2003
  • The aim of research is the evaluation of the $Cr^{6+}$ emission features of the liquid injection through emission experiments in varying conditions, based on a field-mixing ratio. The results showed that the content of $Cr^{6+}$ content in cement measured had an Ordinary Potland Cement (OPC) of 25.3 mg/kg, which constitute the largest portion among the other materials. Likewise, the emission experiment of homo-gel and sand-gel generally satisfied the standard of KSLT (Korea Standard Leaching Test) in waste of 1.5 mg/L, but in case of the standard of KSLT in soil the emission of OPC $Cr^{6+}$ of 4.85 mg/kg. These conditions is a little exceeded the criteria in the ‘Ga’ area in terms of Korea Soil Environmental Preservation Law. In addition, results generated by the mock-up injection facilities revealed that $Cr^{6+}$ emission increased as Water/Cement and injection pressure increased. At injection pressure higher than 4 kg/㎤, $Cr^{6+}$ emission exceeded the water preservation standard of 0.5 mg/L. Similarly, a pattern experiment of C $r^{6+}$ emission according to pH was conducted, in order to evaluate the $Cr^{6+}$ emission features of grout materials in leachate below pH 5 such as pH 4 acid rain or landfill. Results show that $Cr^{6+}$ emission dramatically increased in high acidic or basic state. It indicates that $Cr^{6+}$ emission will probably increase in an environment where grout materials are injected. On the other hand, concentration of leachate was determined in areas where grout materials are used. The results show that the concentration of emission in an ultra purity condition does not manifest intensity, and is affected in the OPC>MC>SC order. It means that the pollutants or $Cr^{6+}$ emission increases with decreasing concentration. As such, $Cr^{6+}$ emission will probably exceed the countermeasure criteria according to the types of gout materials. Similarly, high pressure or injection will cause increased $Cr^{6+}$ emission. Therefore, the selection of materials or mixing ratio should be considered in general as well as according to specific industries, based on the strength and pH of $Cr^{6+}$ emission.

Hand Biometric Information Recognition System of Mobile Phone Image for Mobile Security (모바일 보안을 위한 모바일 폰 영상의 손 생체 정보 인식 시스템)

  • Hong, Kyungho;Jung, Eunhwa
    • Journal of Digital Convergence
    • /
    • v.12 no.4
    • /
    • pp.319-326
    • /
    • 2014
  • According to the increasing mobile security users who have experienced authentication failure by forgetting passwords, user names, or a response to a knowledge-based question have preference for biological information such as hand geometry, fingerprints, voice in personal identification and authentication. Therefore biometric verification of personal identification and authentication for mobile security provides assurance to both the customer and the seller in the internet. Our study focuses on human hand biometric information recognition system for personal identification and personal Authentication, including its shape, palm features and the lengths and widths of the fingers taken from mobile phone photographs such as iPhone4 and galaxy s2. Our hand biometric information recognition system consists of six steps processing: image acquisition, preprocessing, removing noises, extracting standard hand feature extraction, individual feature pattern extraction, hand biometric information recognition for personal identification and authentication from input images. The validity of the proposed system from mobile phone image is demonstrated through 93.5% of the sucessful recognition rate for 250 experimental data of hand shape images and palm information images from 50 subjects.

Analysis of Body Surface Change from 3D Scan Data of Men's Upper Bodies in Twenties - Focus on Application of Motorcycle Jacket Pattern - (3차원 인체데이터에 의한 20대 성인남성 상반신 체표변화 분석 - 모터사이클복 패턴설계시 적용을 중심으로 -)

  • Do, Wol-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.32 no.4
    • /
    • pp.530-541
    • /
    • 2008
  • The early stage of 3D anthropometry data has been used to obtain qualitative rather than quantitative information. However recent 3D body scanners as a common research tool for anthropormatric measurments have made it possible to obtain body surface data of sufficient resolution and accuracy. The purpose of this study is finally to develop motorcycle jacket for enhanced comfort and fit, to test the accuracy and reliability of 3D measurments of motorcycle riding posture, and to analyze the change in 20's adult male's body surface measurements between the standard anthropometric position and motorcycle riding posture. The results of this study were as follows: There were no significant differences between the study and Size Korea measurments in total traditional measuring items and most of measuring items, such as length, circumference antropometric items and interscye items though not waist back length and upper arm circumference. A comparison of 3D body surface measurments in the two different measuring postures, the bodysurface measurments such as waist front length, biacromion length, front interscye, arm length, underarm length in the motorcycle riding posture decreased than that in basic posture, whereas waist back length, back interscye, C.T.W length increased. The body surface measurments such as chest, bust, upper circumference in the motorcycle riding posture decreased than that in basic posture, whereas neck, waist, hip, elbow circumference increased.

Numerical Investigation of Micro Thermal Imprint Process of Glassy Polymer near the Glass Transition Temperature (열방식 마이크로 임프린트 공정을 위한 고분자 재료의 수치적 모델링과 해석)

  • Lan, Shuhuai;Lee, Soo-Hun;Lee, Hye-Jin;Song, Jung-Han;Sung, Yeon-Wook;Kim, Moo-Jong;Lee, Moon-G.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.45-52
    • /
    • 2009
  • The research on miniature devices based on non-silicon materials, in particular polymeric materials has been attracting more and more attention in the research field of the micro/nano fabrication in recent years. Lost of applications and many literatures have been reported. However, the study on the micro thermal imprint process of glassy polymer is still not systematic and inadequate. The aim of this research I to obtain a numerical material model for an amorphous glassy polymer, polycarbonate (PC), which can be used in finite element analysis (FEA) of the micro thermal imprint process near the glass transition temperature (Tg). An understanding of the deformation behavior of the PC specimens was acquired by performing tensile stress relaxation tests. The viscoelastic material model based on generalized Maxwell model was introduced for the material near Tg to establish the FE model based on the commercial FEA code ABAQUS/Standard with a suitable set of parameters obtained for this material model form the test data. As a result, the feasibility of the established viscoelastic model for PC near Tg was confirmed and this material model can be used in FE analysis for the prediction and improvement of the micro thermal imprint process for pattern replication.

  • PDF

An Improved PCR-RFLP Assay for Detection and Genotyping of Asymptomatic Giardia lamblia Infection in a Resource-Poor Setting

  • Hawash, Yoursry;Ghonaim, M.M.;Al-Shehri, S.S.
    • Parasites, Hosts and Diseases
    • /
    • v.54 no.1
    • /
    • pp.1-8
    • /
    • 2016
  • Laboratory workers, in resource-poor countries, still consider PCR detection of Giardia lamblia more costly and more time-consuming than the classical parasitological techniques. Based on 2 published primers, an in-house one-round touchdown PCR-RFLP assay was developed. The assay was validated with an internal amplification control included in reactions. Performance of the assay was assessed with DNA samples of various purities, 91 control fecal samples with various parasite load, and 472 samples of unknown results. Two cysts per reaction were enough for PCR detection by the assay with exhibited specificity (Sp) and sensitivity (Se) of 100% and 93%, respectively. Taking a published small subunit rRNA reference PCR test results (6%; 29/472) as a nominated gold standard, G. lamblia was identified in 5.9% (28/472), 5.2%, (25/472), and 3.6% (17/472) by PCR assay, $RIDA^{(R)}$ Quick Giardia antigen detection test (R-Biopharm, Darmstadt, Germany), and iodine-stained smear microscopy, respectively. The percent agreements (kappa values) of 99.7% (0.745), 98.9% (0.900), and 97.7% (0.981) were exhibited between the assay results and that of the reference PCR, immunoassay, and microscopy, respectively. Restriction digestion of the 28 Giardia-positive samples revealed genotype A pattern in 12 and genotype B profile in 16 samples. The PCR assay with the described format and exhibited performance has a great potential to be adopted in basic clinical laboratories as a detection tool for G. lamblia especially in asymptomatic infections. This potential is increased more in particular situations where identification of the parasite genotype represents a major requirement as in epidemiological studies and infection outbreaks.