• 제목/요약/키워드: Standard operating system

검색결과 673건 처리시간 0.032초

수술 간호업무 중 발생한 의료오류의 분석;웹기반 보고체계를 적용하여 (Analysis of Medical Errors in Operating Room Nursing using Web;based Error Reporting System)

  • 김명수
    • 간호행정학회지
    • /
    • 제12권3호
    • /
    • pp.397-405
    • /
    • 2006
  • Purpose: The purpose of this study was to develop the medical error reporting system and to validate an trait of error in the Operating Room. Methods: Descriptive research design was used. The subjects were 30 nurses with below 5-year-career in a University Hospital. Data was collected from 11, April until 22, April, 2005 using web-based error reporting system. Data was analyzed by mean, standard deviation, $X^{2}-test$ using SPSS WIN 10.0 program. Results: A time of medical error in operating room nursing frequent occurrence was from 12 pm. to 4pm. 'Lack of sterile materials' management' was the best frequent occurrence of medical error in operating room nursing. Conclusion: The findings of this study show that manager of healthcare organization must develop the error reporting system more familiar and ordinary. Afterward, we prevent the repetitive medical errors in nursing care through analyzing of error reporting system.

  • PDF

태양광 연계 계통의 주파수 보호 기준 정립 (The Frequency Protection of Distribution System with Photovoltaic System)

  • 서훈철;김철환;윤영민
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.440_441
    • /
    • 2009
  • The standard for the frequency protection of distributed generation in Korea Electric Power Corporation (KEPCO)'s standard doesn't include the setting of frequency protection. Therefore, this paper analyzes the correlation between the frequency protection requirements and the stability of grid-connected PV system for the adjustable operating setting of frequency protection. The distribution system interconnected with 3 MW PV system is modeled by Matlab/Simulink. The various value of frequency is simulated. For studied cases, the stability of PV system is analyzed. It is concluded that the operating setting of frequency protection can be determined by the stability of PV system.

  • PDF

차량용 MOST 네트워크를 위한 POSIX 기반의 Network Service 설계 및 구현 (Design and Implementation of MOST Network Service over POSIX)

  • 이무열;정성문;진현욱
    • 대한임베디드공학회논문지
    • /
    • 제5권1호
    • /
    • pp.23-28
    • /
    • 2010
  • The automotive industry tries to provide infotainment systems to emerging automobiles. Since the infotainment systems require various peripheral devices and network connectivity, legacy operating systems such as Linux and Windows can be much preferred due to its plentiful device drivers and multimedia applications while the operating systems following OSEK standard are used for automotive electronic control units. Thus it is highly desired that the system software supporting infotainment applications can be portable over different legacy operating systems providing unified programming interfaces. The majority of legacy operating systems support POSIX interfaces for application development. MOST is an automotive network standard for infotainment systems. Network Service defines the protocol stacks for MOST control data, which is essential to implement infotainment applications over MOST. In this paper, we suggest a POSIX-based Network Service so that we can utilize legacy device drivers and applications for automotive infotainment systems. We measure the performance of the POSIX-based Network Service and show that its overhead is not significant.

UbiFOSTM 실시간 운영체제에서 POSIX지원을 위한 래퍼의 설계 및 구현 (Design and Implementation of Wrapper to Support POSIX Standards on UbiFOSTM Real-Time Operating System)

  • 송예진;조문행;이철훈
    • 한국콘텐츠학회논문지
    • /
    • 제7권8호
    • /
    • pp.31-40
    • /
    • 2007
  • 최근의 내장형 시스템은 그 용도에 따라 특정 기능만 수행하는 단순한 응용프로그램을 탑재했던 과거와는 달리 멀티미디어 기능들이 하나로 통합된 디지털 컨버전스 기기로 진화하면서 응용프로그램의 복잡도가 현저히 증가하였다. 또한 응용프로그램은 그 시대의 요구에 따라 여러 응용프로그램들과 통합되고 진화해 간다. 이러한 응용프로그램을 개발하고 관리하기 위해서는 개발자와 관리자간의 표준화된 인터페이스가 필요하다. 컴퓨팅 시스템에서 개방형 시스템 구조를 갖는 표준 중 운영체제의 인터페이스에 대한 표준으로 POSIX(Portable Operating System Interface)가 개발되었으며, 디지털 컨버전스 기기와 같이 실시간 운영체제 탑재를 요구하는 시스템을 위한 인터페이스 표준으로 POSIX.4계열이 있다. 본 논문에서는 개방형 실시간 운영체제 인터페이스 표준인 POSIX.4 지원을 위한 래퍼(wrapper)를 실시간 운영체제 UbiFOSTM에 설계 및 구현한 내용을 기술한다. 또한, POSIX.4 표준을 준수한 응용프로그램을 Linux와 UbiFOSTM에 각각 탑재하여 비교 실험하고 구현한 래퍼의 성능 오버헤드가 $3{\sim}9{\mu}s$로 미미하다는 측정 결과를 제시한다.

병원 수술실 설계 및 시공에 관한 연구 (A study on the design and construction of operating room)

  • 정을규;오정근
    • 한국건축시공학회지
    • /
    • 제3권2호
    • /
    • pp.103-110
    • /
    • 2003
  • In the early 1990's the clean room system was a new trend of the operating room. This is the concept using in seminconductor plants. That is what the space around the operating table so clean as it remove contaminations with circulation of interior air. These articles describe the standard of interior construction and drawing details.

실시간 앙상블 가뭄전망정보 생산 체계 구축 및 평가 (Development & Evaluation of Real-time Ensemble Drought Prediction System)

  • 배덕효;안중배;김현경;김헌애;손경환;조세라;정의석
    • 대기
    • /
    • 제23권1호
    • /
    • pp.113-121
    • /
    • 2013
  • The objective of this study is to develop and evaluate the system to produce the real-time ensemble drought prediction data. Ensemble drought prediction consists of 3 processes (meteorological outlook using the multi-initial conditions, hydrological analysis and drought index calculation) therefore, more processing time and data is required than that of single member. For ensemble drought prediction, data process time is optimized and hardware of existing system is upgraded. Ensemble drought data is estimated for year 2012 and to evaluate the accuracy of drought prediction data by using ROC (Relative Operating Characteristics) analysis. We obtained 5 ensembles as optimal number and predicted drought condition for every tenth day i.e. 5th, 15th and 25th of each month. The drought indices used are SPI (Standard Precipitation Index), SRI (Standard Runoff Index), SSI (Standard Soil moisture Index). Drought conditions were determined based on results obtained for each ensemble member. Overall the results showed higher accuracy using ensemble members as compared to single. The ROC score of SRI and SSI showed significant improvement in drought period however SPI was higher in the demise period. The proposed ensemble drought prediction system can be contributed to drought forecasting techniques in Korea.

척도운용체계를 통해 본 18세기 화성건축의 건축구성에 관한 연구 (A Study on the Operating System of the Architectural Standard Scale of Length(尺度, Korean foot) used in the Hwasong City Wall in the 18th Century)

  • 이호락;이상해
    • 건축역사연구
    • /
    • 제6권2호
    • /
    • pp.65-77
    • /
    • 1997
  • The Hwasong City Wall was built for three years(1794-1796), but the real construction term was taken only 28 months. The wall and the buildings on the wall were built simultaneously, and the esttimated construction cost was highly restricted. These conditions were main factors for considering the high efficiency of construction productivity. This study examines these factors that are reflected in the operating system of the architectural standard scale of length, the architectural composition system in the Hwasong City Wall to reduce the construction cost. Through the study, following factors are found. 1.The rule of multiple proportion is found in the relationship between the partition distance, that is, span and the height of the girder which is related to the productivity of ready-made building members. 2.The ruling grade system of scale in the component members is found in the chang-bang(창방, penetration members)

  • PDF

도시철도용 무선통신기반 열차제어시스템 운영시나리오 연구 (A study of Operational Scenarios for the Wireless Communications Based Train Control System)

  • 윤용기;오세찬;이강미;조현정;김용규
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.904-909
    • /
    • 2011
  • The development of train control system shall operate a series of processes like system designing, system production and system performance evaluation as a result of various requirements analysis presented in operation rules, operating guidelines for railway organizations etc, notified by the nation. Therefore, considering operation conditions, operation plan, linkage to railway network etc, the major document like system functional specifications, system development specifications, system test plans etc must be drawn up. In this paper we classify system operating scenarios required to prepare for system standard specification and system performance evaluation report of CBTC system for urban subways supporting unmanned automatic operation, and adjust each of the operating status.

  • PDF

장기 안정성을 고려한 경질유 유량표준장치 불확도 평가 (Long Term Stability of Uncertainty Analysis of Light Oil Elow Standard System)

  • 임기원;최종오
    • 대한기계학회논문집B
    • /
    • 제29권10호
    • /
    • pp.1130-1138
    • /
    • 2005
  • A national standard system for the petroleum field has been developed to calibrate and test the oil flow meters in Korea. The operating system and the uncertainty of the system were evaluated by the peer reviewers of foreign national metrology institutes in 2002. Since the characteristics of the system might be changed by time, the uncertainty of the system is reevaluated with the consideration of the long term stability of the system. It is found that the system has a relative expanded uncertainty of 0.048 $\%$ in the range of $15\~120\;m^3/h$. According to the uncertainty budget, the uncertainties of the fluid density and the final mass measurement, which are temperature dependent, contribute about $94\%$ of the total uncertainty in the oil flow standard system

Analysis of IEC 61727 Photovoltaic (PV) systems Characteristics of the utility interface

  • Lee, Jeong Hyeon;Yoon, Yong Ho;Kim, Jae Moon
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제7권2호
    • /
    • pp.90-95
    • /
    • 2015
  • This paper describes IEC 61727 standard of Photovoltaic (PV) systems -Characteristics of the utility interface. IEC 61727 standard tests include utility compatibility and personnel safety and equipment protection of PV inverter performance functions. Especially utility compatibility part includes test items of 1) voltage, current and frequency, 2) normal voltage operating range, 3) flicker, 4) DC injection, 5) normal frequency operating range, 6) harmonics and 7) waveform distortion, 8) power factor of PV inverter. Also personnel safety and equipment protection part includes test items 1)loss of utility voltage, 2)over/under voltage and frequency, 3)Islanding protection, 4)response to utility recovery, 5)earthing, 6)short circuit protection, 7)Isolation and switching of PV inverter. In this paper, each item of IEC 61727 standard test is studied and analyzed and finally full tested by PV inverter performance function.