• Title/Summary/Keyword: Standard measure

Search Result 1,921, Processing Time 0.031 seconds

Reliability Analysis of Finger Joint Range of Motion Measurements in Wearable Soft Sensor Gloves (웨어러블 소프트 센서 장갑의 손가락 관절 관절가동범위 측정에 대한 신뢰도 분석)

  • Eun-Kyung Kim;Jin-Hong Kim;Yu-Ri Kim;Ye-Ji Hong;Gang-Pyo Lee;Eun-Hye Jeon;Joon-bum Bae;Su-in Kim;Sang-Yi Lee
    • PNF and Movement
    • /
    • v.21 no.2
    • /
    • pp.171-183
    • /
    • 2023
  • Purpose: The purpose of this study was to compare universal goniometry (UG), which is commonly used in clinical practice to measure the range of motion (ROM) of finger joints with a wearable soft sensor glove, and to analyze the reliability to determine its usefulness. Methods: Ten healthy adults (6 males, 4 females) participated in this study. The metacarpophalangeal joint (MCP), interphalangeal joint (IP), and proximal interphalangeal joint (PIP) of both hands were measured using UG and Mollisen HAND soft sensor gloves during active flexion, according to the American Society for Hand Therapists' measurement criteria. Measurements were taken in triplicate and averaged. The mean and standard deviation of the two methods were calculated, and the 95% limits of agreement (LOA) of the measurements were calculated using the intraclass correlation coefficient (ICC) and Bland-Altman plot to examine the reliability and discrepancies between the measurements. Results: The results of the mean values of the flexion angles for the active range of motion (AROM) of the finger joints showed large angular differences in the finger joints, except for the MCP of the thumb. In the inter-rater reliability analysis according to the measurement method, the ICC (2, 1) value showed a low level close to 0, and the mean difference by the Bland-Altman plot showed a value greater than 0, showing a pattern of discrepancy. The 95% LOA had a wide range of differences. Conclusion: This study is a preliminary study investigating the usefulness of the soft sensor glove, and the reliability analysis showed a low level of reliability and inconsistency. However, if future studies can overcome the limitations of this study and the technical problems of the soft sensor glove in the development stage, it is suggested that the measurement instrument can show more accurate measurement and higher reliability when measuring ROM with UG.

Comparison of ultrasound-guided subacromial corticosteroid and ozone (O2-O3) injections in the treatment of chronic rotator cuff tendinopathy: a randomized clinical trial

  • Merve Orucu Atar;Nurdan Korkmaz;Sefa Gumruk Aslan;Ozge Tezen;Sinem Uyar Koylu;Yasin Demir;Serdar Kesikburun
    • The Korean Journal of Pain
    • /
    • v.36 no.1
    • /
    • pp.128-136
    • /
    • 2023
  • Background: The authors aimed to compare the effects of a one-time ultrasound (US)-guided subacromial corticosteroid injection and three-time ozone (O2-O3) injection in patients with chronic supraspinatus tendinopathy. Methods: Participants were randomly assigned to the corticosteroid group (n = 22) or ozone group (n = 22). Injections in both groups were administered into subacromial bursa with an US-guided in-plane posterolateral approach. Primary outcome measure was the change in the Western Ontario Rotator Cuff Index (WORC) score between baseline and 12-weeks post-injection. Secondary outcome measures included visual analog scale and Shoulder Pain and Disability Index scores. Assessments were recorded at baseline, and 4-weeks and 12-weeks post-injection. Results: Forty participants completed this study. Based on repeated measurement analysis of variance, a significant effect of time was found for all outcome measures in both groups. Both the groups showed clinically significant improvements in shoulder pain, quality of life, and function. Baseline, 4-week post-injection, and 12-week post-injection WORC scores (mean ± standard deviation) were 57.91 ± 18.97, 39.10 ± 20.50 and 37.22 ± 27.31 in the corticosteroid group, respectively and 69.03 ± 15.89, 39.11 ± 24.36, and 32.26 ± 24.58 in the ozone group, respectively. However, no significant group × time interaction was identified regarding all outcome measures. Conclusions: Three-time ozone injection was not superior to a one-time corticosteroid injection in patients with chronic supraspinatus tendinopathy. It might be as effective as corticosteroid injection at 4-weeks and 12-weeks post-injection in terms of relieving pain and improving quality of life and function.

A study on the economic performance measurement model of industrial safety design (산업안전디자인의 경제적 성과측정 모델 연구)

  • Jinho, Ahn
    • Journal of Service Research and Studies
    • /
    • v.13 no.1
    • /
    • pp.176-185
    • /
    • 2023
  • This study is a study to develop a model to measure the economic performance when introducing industrial safety design, which is emerging as a necessity for industrial accident prevention measures due to the increase in the industrial site nursing accident rate and the enforcement of the Serious Accident Punishment Act. To this end, studies on the concept of industrial safety management and industrial safety design and economic performance measurement in the field of industrial safety were conducted in terms of theoretical background. Based on the theoretical background, opinions on drafts of related indicators were collected through user opinion surveys, and focus group interviews and Delphi techniques were conducted with experts, and research was conducted to advance the model. In order to secure objectivity, the causal relationship between the introduction of industrial safety design, cost reduction effect, and sales increase effect was tested through regression analysis. After going through these steps, two models of economic performance measurement of industrial safety design were finally developed: a model based on the first-stage disaster loss cost reduction effect and a second-stage sales increase effect. In order to be applied to actual industrial sites, it should be able to be presented as a standard for the degree of service level agreement of industrial safety design beyond a simple checklist.

Developments of Space Radiation Dosimeter using Commercial Si Radiation Sensor (범용 실리콘 방사선 센서를 이용한 우주방사선 선량계 개발)

  • Jong-kyu Cheon;Sunghwan Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.3
    • /
    • pp.367-373
    • /
    • 2023
  • Aircrews and passengers are exposed to radiation from cosmic rays and secondary scattered rays generated by reactions with air or aircraft. For aircrews, radiation safety management is based on the exposure dose calculated using a space-weather environment simulation. However, the exposure dose varies depending on solar activity, altitude, flight path, etc., so measuring by route is more suggestive than the calculation. In this study, we developed an instrument to measure the cosmic radiation dose using a general-purpose Si sensor and a multichannel analyzer. The dose calculation applied the algorithm of CRaTER (Cosmic Ray Telescope for the Effects of Radiation), a space radiation measuring device of NASA. Energy and dose calibration was performed with Cs-137 662 keV gamma rays at a standard calibration facility, and good dose rate dependence was confirmed in the experimental range. Using the instrument, the dose was directly measured on the international line between Dubai and Incheon in May 2023, and it was similar to the result calculated by KREAM (Korean Radiation Exposure Assessment Model for Aviation Route Dose) within 12%. It was confirmed that the dose increased as the altitude and latitude increased, consistent with the calculation results by KREAM. Some limitations require more verification experiments. However, we confirmed it has sufficient utilization potential as a cost-effective measuring instrument for monitoring exposure dose inside or on personal aircraft.

Investigation of Applying Technical Measures for Improving Energy Efficiency Design Index (EEDI) for KCS and KVLCC2

  • Jun-Yup Park;Jong-Yeon Jung;Yu-Taek Seo
    • Journal of Ocean Engineering and Technology
    • /
    • v.37 no.2
    • /
    • pp.58-67
    • /
    • 2023
  • While extensive research is being conducted to reduce greenhouse gases in industrial fields, the International Maritime Organization (IMO) has implemented regulations to actively reduce CO2 emissions from ships, such as energy efficiency design index (EEDI), energy efficiency existing ship index (EEXI), energy efficiency operational indicator (EEOI), and carbon intensity indicator (CII). These regulations play an important role for the design and operation of ships. However, the calculation of the index and indicator might be complex depending on the types and size of the ship. Here, to calculate the EEDI of two target vessels, first, the ships were set as Deadweight (DWT) 50K container and 300K very large crude-oil carrier (VLCC) considering the type and size of those ships along with the engine types and power. Equations and parameters from the marine pollution treaty (MARPOL) Annex VI, IMO marine environment protection committee (MEPC) resolution were used to estimate the EEDI and their changes. Technical measures were subsequently applied to satisfy the IMO regulations, such as reducing speed, energy saving devices (ESD), and onboard CO2 capture system. Process simulation model using Aspen Plus v10 was developed for the onboard CO2 capture system. The obtained results suggested that the fuel change from Marine diesel oil (MDO) to liquefied natural gas (LNG) was the most effective way to reduce EEDI, considering the limited supply of the alternative clean fuels. Decreasing ship speed was the next effective option to meet the regulation until Phase 4. In case of container, the attained EEDI while converting fuel from Diesel oil (DO) to LNG was reduced by 27.35%. With speed reduction, the EEDI was improved by 21.76% of the EEDI based on DO. Pertaining to VLCC, 27.31% and 22.10% improvements were observed, which were comparable to those for the container. However, for both vessels, additional measure is required to meet Phase 5, demanding the reduction of 70%. Therefore, onboard CO2 capture system was designed for both KCS (Korea Research Institute of Ships & Ocean Engineering (KRISO) container ship) and KVLCC2 (KRISO VLCC) to meet the Phase 5 standard in the process simulation. The absorber column was designed with a diameter of 1.2-3.5 m and height of 11.3 m. The stripper column was 0.6-1.5 m in diameter and 8.8-9.6 m in height. The obtained results suggested that a combination of ESD, speed reduction, and fuel change was effective for reducing the EEDI; and onboard CO2 capture system may be required for Phase 5.

Measurements of Trimethylamine (TMA) in air by Tedlar bag sampling and SPME analysis (환경대기 중 Trimethylamine (TMA)의 측정: Tedlar bag 방식의 채취와 SPME 분석법의 특성 연구)

  • Kim, K.H.;Hyum, S.H.;Im, M.S.
    • Analytical Science and Technology
    • /
    • v.19 no.1
    • /
    • pp.96-102
    • /
    • 2006
  • Trimethylamine (TMA) is one of the difficult odorous compounds for the collection and analysis. Although sulfuric acid absorption and/or sulfuric acid impregnated filter method are commonly recommended for its sampling, these methods also suffer from difficulties involved in sample treatment and operational procedures. Hence, as an ancillary approach to measure TMA, we investigated the combination of bag sampling and SPME analysis for TMA measurements. For the purpose of our study, we investigated the following three subjects: 1) temporal variability of standard storage, 2) bag loss effect of TMS, and 3) TMA loss due to repetitive analysis of an identical bag sample. According to our storage test up to 7 or 20 dyas, TMA loss were found to occur up to 40 to 50% within relatively short period of up to 48 hrs depending on its concentration ranges. When the tests were made for bag loss by transferring TMA standards across different size bags, we were able to find that the extent of bag loss are not significant with 5 to 20% loss rate. Finally, the TMA sorptive loss via its exposure to SPME fiber was generally estimated to run from 2 to 3%.

A Study on the Indirect Benefits of Undergrounding Overhead Power Line Projects in an Urban Area Using Contingent Valuation Method (조건부가치측정법(CVM)을 이용한 도심지 송전선로 지중화사업의 간접편익 추정)

  • Park, Chan-Ho;Kim, Sung-Keun
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.28 no.6D
    • /
    • pp.871-879
    • /
    • 2008
  • Recently, as there are a rise in the standard of living and higher concerns of an electromagnetic wave and environment, undergrounding the aerial cables which are supported by large pylons and generally considered as the least attractive feature of an urban area is on an increasing trend to improve aesthetic benefits and electric reliability. This study applied Contingent Valuation Method (CVM) which is expected to become an effective tool to measure indirect benefit to estimate the substantial benefits of undergrounding overhead power line projects in an urban area. The tunneling construction project of the 345kV Shinsungnam electric power cable in Seongnam city was selected and a hypothetical scenario was given to respondents to determine their levels of Willingness to Pay (WTP) for undergrounding overhead power lines. The result from the estimation of the WTP of undergrounding overhead power lines in Seongnam city was calculated as approximately 17.1 billion won. Placing existing overhead lines underground is difficult to justify economically. Most undergrounding costs appear to be justified by aesthetic and public policy considerations. Therefore, considering the result of this study, undergrounding overhead power lines is of great benefit to public.

Effect of Strength Exercise Program on Health-Related Factors of the Aged for Healthy Life (건강한 삶을 위한 여성 고령자들의 근력운동이 건강관련 요인에 미치는 영향)

  • Kwon, Su-Jeong;Park, Jeong-Bae
    • Journal of Korea Entertainment Industry Association
    • /
    • v.13 no.8
    • /
    • pp.435-446
    • /
    • 2019
  • The purpose of this study was to investigate the effect of strength exercise program(60 minutes/day, 3 times/week) on health-related fitness and the factor of metabolic syndrome in the older at senior care facilities during 12 weeks. Twenty-seven volunteers were recruited for the study and divided into two groups: 15 persons(82.6yrs) undertook a continuous 12 weeks strength exercise program(EG), and 12 persons(78.9yrs) served as a control group(CG). The data process of this study calculated as mean(M) and standard Deviation(SD) of all measured value, used repeated measure ANOVA, and paired t-test. The significant level of hypothesis verification is set-up as α=.05. After 12 weeks in EG, health-related fitness increased by an average of 15.2% for right grip strength(p<.05), 26.9% for left grip strength(p<.05), 32.7% for chair stand(p<.05), 92.5% for one leg stand(p<.05), 29.6% for sit and reach(p<.05), and 34.5% for TUG(p<.05); CG showed no difference between pre and post. In the factor of metabolic syndrome, Systolic BP(3.1mmHg) and fasting blood glucose(7.4mg/dl) decreased in the EG group(p<.05). In summary, the strength exercise program leads to a genuine increase in health-related fitness and decrease in the factor of metabolic syndrome in the older adults. The well planned strength exercise seems to be an important intervention to improve function fitness in this population.

Effect of Attention Feedback Awareness and Control Training on Attention Bias and Generalized Anxiety Symptoms in college students (주의 피드백 인식 및 조절 훈련이 대학생의 주의편향 및 범불안에 미치는 효과)

  • Kim, Su Jung;Shim, Eun-Jung
    • Korean Journal of School Psychology
    • /
    • v.16 no.2
    • /
    • pp.207-230
    • /
    • 2019
  • This study examined the effect of Attention Feedback Awareness and Control Training(A-FACT) on attention bias and generalized anxiety symptoms in college students. A total of 31 college students with at least 10 points on the Generalized Anxiety Disorder 7-item (GAD-7) scale or at least 56 points on the Korean version of the Penn State Worry Questionnaire (K-PSWQ) with attention bias were randomly assigned to one of three groups: A-FACT( n = 11), Attention Bias Modification (ABM)(n = 10) and Active Placebo Control (APC)(n = 10). Participants in A-FACT group received real-time feedback on attention bias based on their Baseline Neutral Response time(BNR) during A-FACT using a dot probe task. Participants in the ABM group received standard ABM, and those in the APC performed a dot probe task that they were informed was a program to reduce attention bias, but feedback was not provided. A total of eight sessions was conducted twice a week over a 4-week period. After every two sessions, GAD-7, K-PSWQ and K-STAI were rated. The effect of attention bias modification training was rated by changes in the Attention Bias Score(ABS), and in GAD-7, K-PSWQ and K-STAI scores. The results of repeated measure ANOVA indicated that the A-FACT group showed a significant decrease in ABS as well as in GAD-7, K-PSWQ and K-STAI scores compared to the other groups. Current results suggest that self-regulatory control of attention, that is, recognition of bias through feedback in A-FACT, may be effective in alleviating attention bias and generalized anxiety symptoms by recognizing bias through feedback on bias in attention bias modification training.

A Study on Monitoring of Health Care and Chronic Diseases for the elderly: the Effect of Wearable Device (고령자 만성질환 및 건강관리 모니터링에 관한 연구: 웨어러블 기기의 효과)

  • Lee, Jong-Sik;Lee, Kang-Nyeon
    • Journal of the Korea Knowledge Information Technology Society
    • /
    • v.13 no.3
    • /
    • pp.351-357
    • /
    • 2018
  • This study is on the elderly people's use and experience of a wearable device. By using wearable device, the elderly can monitor their health data at real time. As a result, their motivation for health care, exercise, and so on can improve and enhance. Across the globe, population aging becomes one of the most important problems in each nation. The social and economic burden from aging is one of most serious challenges to sustainability of the world and its economy, including South Korea. Information Communication Technology including wearable device can help the elderly health care improve. In 2016, the number of wearable devices is more than 19 million. Many of them are the devices related to health data monitoring. In the experiment, the authors measure real time health data from the subjects' wearable devices. In the first experiment day, subjects' average waist size was 36.29 inches. In the final experiment day, 31st day later from start of the experiment, the average waist size was 35.51 inches. At the beginning of the experiment, standard deviation was 1.93. At the final day of the experiment, it was 2.24. In regression analysis, when experiment day extends, average waist size seems to decrease. The trend is significant (t=2.719, p<0.05). That result may mean the subjects' motivation for health care improve. Wearable device can increase the elderly people's motivation for health care and exercise. As a result, their health can improve.