• Title/Summary/Keyword: Standard loading test

Search Result 264, Processing Time 0.026 seconds

Consolidation Characteristics of Lowly Organic Soil under Repeated Loading (반복압밀하중을 받는 저유기질토의 압밀특성)

  • 김재영
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.2
    • /
    • pp.61-69
    • /
    • 1999
  • When the repeated loading, such as vehicel etc, acts on soft ground, consolidation behaviors due to repeated loading wil show different from standard one. A series of tests was performed to investigate the characteristics of consolidation of lowly organic soil subjected to repeated loadings. Lowly organic soil with Lig. 23.5% was sampeld in Chonbuk Province and tested using a partially and a fully repeated loadings. From test results it was found that void ration, volume change, consolidation coefficient, permeability and secondary consolidation coefficient were greatly affected according to the repetition number and the load weight. The secondary consolidation coefficient was decreased with increase of the repetition number. The results obtained from this research can be used as basic for the improvement of soft ground.

  • PDF

POD Analysis for modeling wind pressures and wind effects of a cylindrical shell roof

  • Li, Fanghui;Chen, Xinzhong
    • Wind and Structures
    • /
    • v.30 no.6
    • /
    • pp.559-573
    • /
    • 2020
  • This paper presents a study on the effectiveness of the proper orthogonal decomposition (POD) technique for reconstruction of wind pressure field as applied to a cylindrical shell roof based on simultaneously measured wind pressure data. The influence of wind loading mode truncation on the statistics of dynamic pressures and wind load effects are investigated. The results showed that truncation of higher wind loading modes can have more noticeable influence on the maximum and minimum pressures that the standard derivation (STD) values. The truncation primarily affects the high-frequency content of the pressures. Estimation of background response using wind loading modes is more effective than the use of traditional structural modal analysis.

A Study on the Applicability of Bearing Capacity Formulas of Driven Pile by Comparison with the Results of Static Loading Tests (정재하시험 결과를 통한 타입말뚝 지지력 공식의 타당성 분석)

  • Chun, Byung-Sik;Lee, Seung-Beom
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.544-551
    • /
    • 2004
  • Piles are structural elements made of steel, concrete or timber, and utilize as pile foundation which is one of deep foundations. Driven pile among them, which drives pile into the ground, is fast-constructable, less expensive and it supplies much bearing capacity. For these reasons, its demand is steady. In this study, by selecting the cases which reached ultimate failure during in-situ static loading tests, bearing capacities acquired from these tests were compared with those computed by existing theories and formula. As the results of the analysis, ultimate bearing capacity computed by theoretic formula were less or similar to those of test results in most cases, but lower ground water level and more dense layer where end of piles were reached remarkably high bearing capacity in theoretical methods. ${\beta}-method$ and Korean structure foundation design standard were sensitive to ground physical properties. Meyerhof metbod and API code were relatively independent from site condition.

  • PDF

Two-Parameter Characterization for the Resistance Curves of Ductile Crack Growth (연선균열성장 저항곡선에 대한 2매개변수의 특성)

  • X.K.Zhu
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.23 no.4
    • /
    • pp.488-503
    • /
    • 1999
  • The present paper considers the constraint effect on J-R curves under the two-parameter $J-A_2$ controlled crack growth within a certain amount of crack extension. Since the parameter $A_2$ in $J-A_2$ three-term solution is independent of applied loading under fully plasticity or large-scale defor-mation $A_2$ is a proper constraint parameter uring crack extension. Both J and $A_2$ are used to char-acterize the resistance curves of ductile crack growth using J as the loading level and $A_2$ are used to char-acterize the resistance curves of ductile crack growth using J as the loading level and A2 as a con-straint parameter. Approach of the constraint-corrected J-R curve is proposed and a procedure of transferring the J-R curves determined from standard ASTM procedure to non-standard speci-mens or real cracked structures is outlined. The test data(e.g. initiation toughness JIC and tearing modulus $T_R$) of Joyce and Link(Engineer-ing Fracture Mechanics 1997, 57(4) : 431-446) for single-edge notched bend[SENB] specimen with from shallow to deep cracks is employed to demonstrate the efficiency of the present approach. The variation of $J_{IC}$ and $T_R$ with the constraint parameter $A_2$ is obtained and a con-straint-corrected J-R curves is constructed for the test material of HY80 steel. Comparisons show that the predicted J-R curves can very well match with the experimental data for both deep and shallow cracked specimens over a reasonably large amount of crack extension. Finally the present constraint-corrected J-R curve is used to predict the crack growth resistance curves for different fracture specimens. over a reasonably large amount of crack extension. Finally the present constraint-corrected J-R curve is used to predict the crack growth resistance curves for different fracture specimens. The constraint effects of specimen types and specimen sizes on the J-R curves can be easily obtained from the constrain-corrected J-R curves.

  • PDF

Development on Test Procedure of Pitch and Yaw Bearings for Wind Turbine (풍력발전기용 피치/요 베어링의 시험절차 개발)

  • Nam, Ju Seok;Han, Jeong Woo
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.24 no.3
    • /
    • pp.355-362
    • /
    • 2015
  • Test procedure for the design verification of wind turbine pitch and yaw bearings has been developed. Test items were selected to evaluate operational reliability of pitch and yaw bearings by considering loading and operational conditions, and by analyzing the design criteria of pitch and yaw bearings. The developed test items consisted of preliminary test, fatigue load test, extreme load test, low temperature environmental test and dismantling inspection after all the test were completed. Because it reflects the actual operational conditions of the pitch and yaw bearings, the developed test procedure has high reliability and can verify the basic design considerations in the international standard and guidelines.

A study on the optimization for size design of EMU aluminium bodyshell (알루미늄 구조체의 치수 최적화에 관한 연구)

  • 홍재성;이호용;김원경;최성규
    • Proceedings of the KSR Conference
    • /
    • 1999.05a
    • /
    • pp.232-237
    • /
    • 1999
  • The standardization urban transit project has been started by government and the Korean standard electrical railcar has been designed. The bodyshell of standard railcar is made of aluminium alloy. In the present paper, the design of its bodyshell is evaluated in the viewpoint of strength analysis. The loading condition is based on the 'Test Methods of Static Load for Body Structure of Electrical Multiple Unit', standard specification. The bodyshell of Korean standard EMU consist of longitudinal extrusion members which are double-skin structure type. For the purpose of security and lightening we decided the section of the aluminium carbody through the size optimization in this paper Hereafter this paper will contribute to the shape optimization.

  • PDF

Study on the subgrade reaction modulus$(K_{30})$ and strain modulus$(E_v)$ (지반반력계수$(K_{30})$와 변형률계수$(E_v)$에 대한 고찰)

  • Kim, Dae-Sang;Choi, Chan-Yong;Kim, Seong-Jung;Yu, Jin-Young;Yang, Sin-Chu
    • Journal of the Korean Society for Railway
    • /
    • v.10 no.3 s.40
    • /
    • pp.264-270
    • /
    • 2007
  • Two modulus, strain modulus $(E_v)$ and subgrade reaction modulus $(K_{30})$ are being used as a standard for bearing stiffness in Korea Railroad design. The first is used in Europe and the other is used in Japan. The methodologies to obtain the two modulus are similar in using plate. But testing methods are different in loading to plate. Therefore, according to soil strain range, there should be large gap in not only computations of deformation modulus but also the necessary time to test. At first, this paper focuses on the two kinds of test methods to evaluate bearing stiffness. Secondly, based on elastic theory, the theory to obtain the two coefficients are studied thoroughly. Finally, the correlations between the two coefficients were analyzed and evaluated based on the field test results more than 38 places. The matching values for subgrade and ground between $K_{30}$ and $E_{v2}$ are proposed with the consideration of the proposed strain reduction factor (1.5 for subgrade and 3 for ground) and safety factor, respectively.

Bending Properties and Recommened Design Criteria for Domestic Softwood with Notch (파임을 가진 국산 침엽수재의 휨성능 및 구조설계기준에 관한 연구)

  • Oh, Sei-Chang
    • Journal of the Korean Wood Science and Technology
    • /
    • v.26 no.4
    • /
    • pp.6-12
    • /
    • 1998
  • Test results of domestic softwood lumber were presented to examine the notch effect of beams and compare to present AIJ(Architecture Institute of Japan) formula in notched wood member especially positioned in bottom side (tension side) of a beam. Notched lumber was tested under following condition : each specimen supported simply, and subjected to third-point loading at points of 1/3 of the span length. Notch was located opposite side to loading direction and notch depth were 1/6, 1/4, 1/3 of beam depth. Deflection and load were measured by digital dial guage each in 25kgf increment. Bending test results were as follows; Mpro/Mmax range (proportional and maxium bending moment ratio in notched beam) was 0.5 - 0.65. It was considered that maxium bending moment was about 1.5 times to proportional bending moment in notched beam and showed same tendency in the test result of ordinary wood specimens. AU standard formula for the tension side notch, Mmat = 0.6 ${\times}$ (Zo $\sigma$), the constant 0.6 was suitble for notch ratio(notch depth to beam depth) 1/6, but this ratio for 1/4, and 1/3 was not. So it is preferable to accept smaller value than 0.6 for notch ratio more than 1/3. These experiment results showed critical effect in tension side notched wood beam especially in greater than notch ratio 1.3 of wood beam. From the above results, it is recommened to revise design formula adoptable to domestic wood constructon member with tension side notched member.

  • PDF

Application of Horizontal Barrier on a Rack to Reduce Fire Spread (화재확산 저감을 위한 랙크 내 수평차단막 적용에 관한 연구)

  • Yeo, In-Hwan;Cho, Gyu-Hwan
    • Fire Science and Engineering
    • /
    • v.31 no.4
    • /
    • pp.71-79
    • /
    • 2017
  • A rack warehouse with a vertically loading type and high loading density has severe risks and damage during its fire. In this regard, US and Japan strive to minimize the fire spread by applying in-rack sprinkler, horizontal barriers, etc. corresponding to their own rack warehouse but there is no study and policy in Korea. Therefore, a model scale fire test was carried out targeting the standard rack incorporating the national rack warehouse in order to check fire characteristics in ignition points and installation distances of horizontal barriers in this study. As a result of the test, vertical fire spread of about 30% was inhibited by narrowing its installation distance from 2-layer to 1-layer in an ignition condition of the flue space. In addition, as a result of the measurement of the temperature in the upper and lower parts of the horizontal barrier, the temperature distribution showed about 2~4 higher in a condition with an installation of the barrier than that in the condition without the barrier. Consequently, it is likely that the horizontal barrier will help the initial operation of in-rack sprinkler.

Characteristics of Bond Strength with Measuring Methods of Concrete (시험방법에 따른 신ㆍ구 콘크리트의 부착강도 특성)

  • 장흥균;김성환;홍창우;윤경구
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.597-600
    • /
    • 2003
  • The development and maintenance of a sound bond are an essential requirements of concrete repair and replacement. The bond property of a bonded overlay to its substrate concrete during the lifetime is one of the most important performance requirements which should be quantified. A standard or a verified bond strength measurement method is required at field for screening, selecting materials and quality control for overlay or repair materials. This study compares the nipple pipe direct tensile test, flexural adhesion test, and core pull-off test with their test results. Substantial differences in the failure stresses of three test methods were attributed to their different geometries and loading conditions. From these comparison and investigation, core pull-off test was relatively good because the coefficient of variation values were about 2%. It would be suitable for use in-situ because of its simplicity and accuracy.

  • PDF