• Title/Summary/Keyword: Standard facility

Search Result 917, Processing Time 0.031 seconds

Legislative and policy issues related to the advancement of the maintenance system of water resource facilities (수자원시설물의 유지관리 체계 선진화를 위한 입법 및 정책과제)

  • Lee, Giha;Yeon, Minho;Lee, Daeeop;Kim, Seongwon;Kim, Jinsoo
    • Journal of Korea Water Resources Association
    • /
    • v.53 no.spc1
    • /
    • pp.773-784
    • /
    • 2020
  • In this study, legislative and policy issues related to advancing the maintenance system of water resource facilities were presented by investigating and analyzing the degree of aging and management status of water resource facilities. Data from the comprehensive Facility Management System (FMS) operated by the Korea Infrastructure Safety Corporation were collected and used to analyze the aging of water resource facilities. Using safety grade data categorized by facility, type, local area, and grade, the ratio of dangerous facilities and the aging rate were calculated to analyze the status of water resource facilities and guidelines and manuals related to water resource facilities were investigated. Through this, four required actions to address legislative and policy issues were presented: 1) Readjusting the scope of water resource facilities and supplementing guidelines and manuals, 2) Establishing a maintenance system considering changes in disaster conditions, 3) Improving the FMS and activating standard linkage services, and 4) Establishing a facility asset management system.

Methodology Study of Design Related to Accidental Explosion of Simple Explosive Storage Facility (화약류 간이저장소의 우발적 폭발을 고려한 안전설계 방법 연구)

  • Jung-Gyu, Kim;Seung-Won, Jung;Jun-Ha, Kim;Byung-Hee, Choi
    • Explosives and Blasting
    • /
    • v.40 no.4
    • /
    • pp.1-14
    • /
    • 2022
  • To review the appropriateness of current regulations on the simple explosive storage facility, the effects of internal explosion on the structural stability of the standard storage facility were analyzed by means of both FEM analyses and field experiments. As a result, it was found that the explosion-proof performance of the existing storage structure was not sufficient for 15 kg of emulsion-type explosive. Thus, an alternative method of splitting explosives was tested by conducting sympathetic detonation experiments. This method worked properly as expected, and the proper amount of splitted explosive was determined according to the test results. In addition, a storage structure with open ceiling was found to be very effective because explosion pressure was released so rapidly that the damage of the facility could be reduced significantly. Hence, such a structural pattern was proposed as a new design scheme for simple explosive storage facility.

Development of standard calibration equipment for the rain gauges

  • Shin, Gang-Wook;Hong, Sung-Taek;Lee, Dong-Keun
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2468-2473
    • /
    • 2005
  • Because the rain gauges of tipping bucket type can easily use the digital signal, the rain gauges are widely used for the meteorological observation. In general, the resolution of rain gauges of tipping bucket type can be categorized by the 0.1mm, 0.5mm, and 1.0mm classes. But, the error of the tipping bucket rain gauges is made by the intensity of rainfalls and is expected to make the standard calibration method for error measurement. Thus, we developed the hardware of standard calibration facility for rain gauges by weighting measurement method and proposed the standard procedure by rainfall intensity in this study Also, we calculated the error for the rainfall intensity and obtained useful result through the proposed calibration method.

  • PDF

Development and its Validation of Sky Simulator Facilities for Daylighting Evaluation (자연채광 성능평가용 인공천공돔(Sky Simulator)의 개발 및 신뢰성 검증)

  • Kim, Jeong-Tai;Kim, Gon;Yu, In-Hye
    • KIEAE Journal
    • /
    • v.5 no.4
    • /
    • pp.51-57
    • /
    • 2005
  • For the evaluating daylighting performance, field measurement, scale model test and a set of computer tools can be applied. For the scale model measurements, the sky simulator is a vital facility to represent the desired sky conditions consistently. Recently K university has developed a large size sky simulator, 6m-diameter and 3.7m-height, that is suitable for the international standard. To verify the reliability of the sky simulator, the luminance distribution on the inner sky surface was measured and compared with the CIE standard overcast sky model. It is found that the sky simulator can be reproduced the CIE standard overcast sky condition with 4.3% as mean difference. K university sky simulator is fully validated for usability and accuracy for daylighting researches.

Analysis on the Actual Environmental Conditions of Domestic and Oversea Police Detention Facilities (국내외 경찰서 유치시설의 환경 실태 분석)

  • Cho, Hyeonmi
    • Korean Institute of Interior Design Journal
    • /
    • v.22 no.1
    • /
    • pp.339-349
    • /
    • 2013
  • The primary purpose of this research was to set up the standard guidelines for the planning of interior architectural environments of the detention facilities at the Korean Police Stations. By visit-studying the actual interior environmental conditions of 5 different kinds' domestic Correcting Facilities and 5 domestic police detention facilities and 2 foreign police detention facilities, comparing them to the existing Korean correctional institutions' cell facilities, that the strengths and weaknesses had been analyzed to extract the main concepts and the planning scheme for the Standard Korean Police Detention Facilities. By reserching the National human Right Commitee's Anual Reports, three different indexes were picked out for those analysis : the Environmental control index, the Detention Service support index, the Environmental support index. These three indexes will be used as Key factors for the planning of interior architectural environments of the detention facilities at the Korean Police Stations.: (1)the Environmental control index to establish the Space Program, the Spatial Hierarchy and the horizontal & vertical Security Blocks, (2)the Detention Service support index for the central Environmental Control & Security System, the Secured Privacy for both detainees & police offices, (3)the Environmental support index for the gender-respected segregation of cell zones, the psychological & physical safety design factors, the construction standards of all rooms in a detention facility. The result of this study should be used as the guidelines for "The Standard Plans and Regulations for the Korean Police Detention Facilities" to respect fundamental human rights.

A Study on the Passenger Circulation system of the Airport Passenger Terminal (공항 여객터미널 여객동선체계에 관한 연구)

  • Park, Chung-Keun
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.3
    • /
    • pp.260-268
    • /
    • 2010
  • At a passenger terminal which is a core facility of a large-scale airport, users are not easy to recognize its space and to approach each facility by composition of large-scale space not recognized at a glance and arrangement of complicated functional space. Such a passenger terminal should be designed by putting a focus on functionality, safety and convenience since diverse passengers use it. At a passenger terminal, a lot of passengers' circulation followed by diverse purpose appear. Therefore, it needs a lot of functional space and space to satisfy passengers' demands. When circulation is planed, it should be designed by a systematic standard. The study was carried out on the basis of international airports, considering features and functions of airport circulation system. In kind of circulation in passenger terminal of an airport, there are user's circulation (passenger's circulation, employee's circulation and service circulation) and baggage circulation. The study examined passenger's circulation which was a major circulation of passenger terminal out of user's circulation. The study examined elements which had an effect on circulation system at a large-scale airport passenger terminal and basic data for an efficient circulation system standard of passenger terminal through case analysis of passenger terminal circulation systems at international airports.

A Development of Railway Infrastructure BIM Prototype Libraries for Roadbed and Track (노반, 궤도분야 철도인프라 BIM 원형 라이브러리 구축)

  • Park, Hyung-Jin;Seo, Myoung-Bae
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.30 no.5
    • /
    • pp.461-468
    • /
    • 2017
  • The introduction of BIM in domestic construction industry has become more active. Library development and standardization in civil-engineering are unexhausted. This research develop and standardize prototype library for railway infrastructure. We define target facility for library based on railway standard drawings and select BIM software according characteristic of each facility. In this research, we develop libraries composed of 199 files and 489 types for alignment, roadbed and track and make specifications as defined attribution item and description. As we consider for application to diverse use case, develop prototype library in low LoD. We expect that library can increase 3D design productivity and ensure consistency of quality.

Case Studies on Preparing a Business Plan for the Foundation of Food Service Business and Analysis of Investing Economy. (외식사업 신규창업을 위한 사업계획서 작성방법 사례와 투자경제성 분석에 관한 연구)

  • 홍기운
    • Culinary science and hospitality research
    • /
    • v.3
    • /
    • pp.385-421
    • /
    • 1997
  • This study was performed as placing stress on business plan preparation and investing economy analysis centered to cases upon presenting the premises of study for new foundation of food service business. The summarized results are as follows: 1. In the aspect of carrying out process of practical project, establishing the promotion strategy, the facility project program, the menu program, the facility and furniture program, organization & manning schedule, the business operation schedule, review of all laws & provisions and the allout promotion schedule in order were deployed. 2. Analysis of investing economy for review of profitability 1) In case of investment, excluding 600million for the real setate lease among the total investment of 1billion, it was required by 161, 235, 000 for interior project, 161, 110, 000 for facility & equipment, 19, 235, 000 for fittings, 27, 600, 000 for menu plate & uniform, 27, 600, 000 for furniture, 13, 800, 000 for sign article. 2) In case of loss & profit presumed the annual turnover is to be 1, 115, 856, 000 the contigent profit(before tax) is to be 148, 966, 000 which is 13.3% in comparson to the sales amount and the net profit(after tax) for this term s to be 104, 276, 000 which is 9.3% against the sales and the profitable ratio to the equity investment( 500 million) is 20.9% and it satisfies 20% of the premises of study. 3) In case of the payback period will be approximately two(2) years which indicated within three(3) years that is standard of new project evaluation term of ordinary enterprise. 4) In case of internal rate of return it will be 21.5% which is favorable profitability as taking into account of 15% that is standard of new project evaluation by ordinary enterprise based on general downtown money interest. That the investing value of Happy Day profitability is hinted as it is sufficient enough as the case under this study based upon such results and considered that securing supremacy is competitive power in case of commitment will be possible.

  • PDF

A Study on the Management Plan through Performance Maintenance Analysis of Explosion-proof Facilities (방폭설비 성능유지 실태분석을 통한 관리방안 연구)

  • Kwon, Yong Jun;Byeon, Junghwan
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.2
    • /
    • pp.8-16
    • /
    • 2020
  • In Article 311 of the Regulation on Occupational Safety and Health Standards requires the use of Korean Industrial Standards Act in accordance with the Industrial Standardization Act. However, the classification, inspection, maintenance, design, selection, and installation of explosion hazard locations for explosion and explosion prevention and internalization of 'safety' in the performance maintenance phase of electrical machinery and equipment There is no technical and institutional management plan for remodeling and alteration. Analysis of actual conditions and problems related to the installation, use, and maintenance of explosion-proof equipment, comparative analysis of domestic and international technical standards and systems, technical, institutional and administrative systems and systems related to installation, use, and maintenance of explosion-proof equipment, technical personnel and qualifications, etc. It is to propose legislation, system improvement, and technical standard establishment related to the maintenance of explosion-proof facility performance through improvement of the necessity and feasibility study for establishment of the legal status of the management site and management plan. As technical measures, KS standard revision (draft), KOSHA guide (draft) and explosion-proof facility performance maintenance manual were presented. In addition, the institutional management plan proposed the revised rule on occupational safety and health standards, the revised rule on the restriction of employment of hazardous work, and the manpower training program related to the maintenance of explosion-proof facilities and the qualification plan. Enhance safety at the installation, use, and maintenance stage of explosion-proof structured electrical machinery. It is expected to be used to classify explosion hazards, select related equipment, and to update and standardize standards related to installation, use and maintenance.