• Title/Summary/Keyword: Standard ceiling system

Search Result 30, Processing Time 0.023 seconds

Evaluation of Indoor Thermal Comfort for Ceiling Type System Air-Conditioner with Various Discharge Angles (천장형 시스템 에어컨의 토출방향 변화에 따른 실내 열쾌적성 평가)

  • Lee, Jin-Hyung;Kim, You-Jae;Choi, Weon-Seok;Park, Sung-Kwan;Youn, Baek;Kim, Youn-Jea
    • Proceedings of the SAREK Conference
    • /
    • 2006.06a
    • /
    • pp.1180-1185
    • /
    • 2006
  • Modern people spend most of time at indoor space, such as office or classroom. Especially, occupants are exposed to the airtight indoor air quality (IAQ) for a long time, At present, many studies on the air-conditioning systems are more focused on the individual thermal comfort than the thermal efficiency due to increase of the concern of health. There are several factors which are influenced thermal comfort, such as temperature, humidity, convection and air movement, etc. Also, the individual factor, such as age, gender, Physical constitution and habit, should be considered. The 4-way cassette type air conditioner is known to bring out better performance about thermal comfort than the traditional one. This study is performed on the higher ceiling environment than the common buildings or classrooms. Also, this study analyzed on the Indoor thermal comfort by diffusing direction of 4-way cassette air conditioner with various discharge angles, $45^{\circ},\;50^{\circ},\;55^{\circ}$ and $60^{\circ}$. Using a commercial code, FLUENT, three-dimensional transient air thermal flow fields are calculated with appropriate wall boundary conditions and standard $k-{\epsilon}$ turbulence model. Results of velocity and temperature distributions are graphically depicted with various discharge angles.

  • PDF

A Experiment of Sprinkler System to Protect Ceiling Joints of Sandwich Panel Warehouses (샌드위치패널 창고의 벽 천장 접합부 방호용 스프링클러설비 실험)

  • An, Byung-Kug;Kim, Woon-Hyung;Seo, Dong-Hun;Ham, Eun-Gu
    • Journal of the Society of Disaster Information
    • /
    • v.15 no.1
    • /
    • pp.98-108
    • /
    • 2019
  • Purpose: The purpose of this study is to test the sprinkler performance to protect the wall and ceiling joints of the sandwich panel warehouse in case of fire. Method: Based on the field surveys, test was setup and combustibles were prepared. The sprinkler discharge tests were performed at the corner of the wall and right under the sprinkler head. Results: It has been found that operation of the K-80 closed sprinkler head prevents the ignition of the sandwich panel and therefore no damage to the joints of sandwich panels. To prevent skipping phenomenon, it is necessary to install the sprinkler head from the corner of the wall and to keep a minimum distance of 2.4m and a maximum distance of 3m. Conclution: A Standard Operation Procedure should be prepared to suppress and rescue of fire brigade for a sandwich panel warehouse protected by perimeter sprinklers preventing a ignition of core materials and control fire.

Analysis of Design Elements and Barriers to Link the Emission Trading Systems between the Republic of Korea and China (한·중 배출권거래제 연계를 위한 설계요소 및 장애요인 분석)

  • Park, Su Gyeong;Park, Soon chul;Song, Cholho;Lim, Chul-Hee;Lee, Soo Jeong;Lee, Woo-Kyun
    • Journal of Climate Change Research
    • /
    • v.9 no.4
    • /
    • pp.471-485
    • /
    • 2018
  • The Republic of Korea (ROK) has made many efforts to reduce greenhouse gases through a legal framework, making obligations to reach domestic and overseas targets via the Paris Convention in 2015. China recently launched a nation-wide emission trading system (ETS) and has considered extending this ETS to include the ROK. This study examines the possibility of linking the ETS between ROK and China by considering the institutional design elements of the ETS. Additionally, this study provides policy implications to reach Korea's overseas reduction target. For the research methodology, the design elements of both the ROK and China policies were analyzed by categorizing their standard design elements based on the International Carbon Action Partnership. This paper focuses on four main barriers (cap type, borrowing, offset and price ceiling) based on their environmental benefits and analyzes the challenges to combining the design elements between the ROK and China systems. The two ETS commonly share the same cap types, and there is similar institutional progress regarding the offset and price ceiling. In addition to this, note that China has a borrowing system that is opposite to the borrowing system in ROK. According to these findings, there are major challenges to linking the ROK and China systems due to differences in the major design elements. Thus, it is necessary to modify the Korean domestic borrowing system and understand the Chinese institutional processes related to environmental negotiation to achieve further cooperation.

Mechanical evolution law and deformation characteristics of preliminary lining about newly-built subway tunnel closely undercrossing the existing station: A case study

  • Huijian Zhang;Gongning Liu;Weixiong Liu;Shuai Zhang;Zekun Chen
    • Geomechanics and Engineering
    • /
    • v.35 no.5
    • /
    • pp.525-538
    • /
    • 2023
  • The development of a city is closely linked to the construction and operation of its subway system. However, constructing a new subway tunnel under an existing station is an extremely complex task, and the deformation characteristics and mechanical behavior of the new subway tunnel during the excavation process can greatly impact the normal operation of the existing station. Although the previous studies about the case of underpass engineering have been carried out, there is limited research on the condition of a newly-built subway tunnel that closely undercrossing an existing station with zero distance between them. Therefore, this study analyzes the deformation law and mechanical behavior characteristics of the preliminary lining of the underpass tunnel during the excavation process based on the real engineering case of Chengdu Metro Line 8. This study also makes an in-depth comparison of the influence of different excavation methods on this issue. Finally, the accuracy of numerical simulation is verified by comparing it with on-site result. The results indicate that the maximum bending moment mainly occurs at the floor slab of the preliminary lining, while that of the ceiling is small. The stress state at the ceiling position is less affected by the construction process of the pilot tunnel. Compared to the all-in-one excavation method, although the process of partial excavation method is more complicated, the deformation of preliminary lining caused by it is basically less than the upper limit value of the standard, while that of the all-in-one excavation method is beyond standard requirements.

Acceptable Supply Air Conditions of Dedicated Outdoor Air System for a High-rise Apartment Building (초고층 공동주택 외기전담 시스템 기반 중앙 공급식 환기시스템의 적정 급기조건 설정)

  • Kim, Min-Hwi;Kim, Jin-Hyo;Kwon, Oh-Hyun;Jeong, Jae-Weon
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.285-290
    • /
    • 2009
  • The main thrust of this paper is to investigate acceptable supply air conditions of a dedicated outdoor air system (DOAS) for highrise apartment buildings. As for a typical $132-m^2$ apartment unit, it was assumed that centralized DOAS-Ceiling Radiant Cooling Panel was installed. Transient behavior and control characteristics of each system were modeled numerically using a commercial equation solver program. The optimized dew point temperature of the DOAS was discussed on the basis of the ASHRAE standard 62.1-2007 and the current Korean ventilation standard for apartments. It was found that the optimized dew point temperature of the DOAS supply air accommodating total latent load of a space is $11-12^{\circ}C$ and the appropriate supply air temperature of the DOAS is $11-12^{\circ}C$ in cooling period and neutral temperature of $18-20^{\circ}C$ in intermediate period.

  • PDF

The Development of Damping Material for Standard Floating Floor Type-5 Using Ethylene Vinyl Acetate co-polymer(EVA) & Urethane Form (EVA와 경질우레탄폼을 이용한 표준바닥구조 벽식-5용 단열완충재 개발)

  • Park, Cheol-Yong;Kim, Sang-Hoon;Jang, Dong-Woon;Jang, Cheol-Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.461-464
    • /
    • 2004
  • The reduction effect of floor impact noise depends on the various factors such as stiffness and thickness of the concrete slab, finishing If ceiling materials and the composition method. Among the rest it is well known that floating floor system is more effective. Standard floating floor(SFF) type-2 consisted of 50mm lightweight aerated concrete(LAC) and 20mm damping material has been widely used. But LAC construction problem on dry damping material occurred and the reduction effect of floor impact noise has bare minimum qualifications. Thus the aim of this study is to develop 40mm composite damping material(Soundzero Plus) for SFF type-5 which substitute LAC and damping material. 'Soundzero Plus' is satisfied with quality requirement for damping material for SFF. The heat transition rate, $0.45W/m^2{\cdot}K$ is more effective 55% about than the regulation. The test results of floor impact noise by using 'Soundzero Plus' are showed good improvement about 12dB (tested by tapping machine) and 4dB (tested by bang machine) between before and after.

  • PDF

Comparative Analysis on the Mock-ups' Configuration and Monitoring Protocol System of Advanced Daylighting Systems for Daylighting Experiment - Focused on IEA SHC Task21- (첨단채광시스템 실험용 Mock-Up 모형의 형상 및 모니터링 프로토콜 시스템에 관한 비교분석 - IEA SHC Task21을 중심으로-)

  • Jeong, In-Young;Choi, Sang-Hyun;Kim, Jeong-Tai
    • KIEAE Journal
    • /
    • v.4 no.1
    • /
    • pp.11-20
    • /
    • 2004
  • Innovative daylighting systems in buildings in various climatic zones around the world have been developed under the IEA SHC Task21. The performance assessment were obtained by monitoring the most systems using full-scale test model rooms or actual buildings under real sky conditions. This study aims to analyze the configuration and monitoring system of the nine Mock-up models of the IEA SHC Task21 comparatively. For the purpose, the geometry of the test rooms (length, width, height, window area, glazed area and occupied), reflectance of walls, floor and ceiling, transmittance of glazing (transmittance for hemispherical irradiation, normal irradiation and U-value) were compared. And equipment for measurement (manufacturer, range, calibration, maximum calibration error, cosine response error, fatigue error), and data acquisition system (manufacturer, type, number of differential analogue input channels, A/D converter resolution in bits, data acquisition software) were also analyzed comparatively. Some findings of these experimental methodology of standard monitoring have been proven to be a valuable one for future assessment of advanced daylighting systems in our country.

An Experimental Study on the Noise Characteristics of Water Supply and Drain Installations Varied with Water Suppling Pressure in Apartment Bathroom (급수압 변화에 따른 대변기와 세면기의 급배수 소음 특성에 관한 실험적 연구)

  • Lee, Tai-Gang;Ko, Kwang-Pil;Choi, Eun-Suk;Kim, Hang;Kim, Sun-Woo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.3 s.120
    • /
    • pp.226-234
    • /
    • 2007
  • This study aims to evaluate noise emission from water supply and drain installations in apartment bathroom. These noise were one of the most annoying noise sources in apartment houses. Especially, drain plumbing system have used bellow bathroom ceiling, it was very discomfort to hear the noise in bellow apartment. Noise of closets and faucets were measured which were main noise source, then these noise were evaluate and analyzed the emitting characteristics varying the supplying water pressure. As increasing the water pressure, also total noise level of the water supplying stool noise and faucet noise were increased. Especially the water closet showed remarkably the increasing noise level in middle and high frequency bandwidth, while the noise level of faucets increased in $50\;Hz{\sim}250\;Hz$ of low frequency bandwidth. Vortex closet were favorable to syphon closet, and lever faucet were favorable to conventional lavatory faucet on reducing the noise. Above these results could be used in basic data establishing KS (Korean Standard) for evaluation and rating procedure and measures reducing these noise.

Analysis on Dimming Control Effect by Algorithm Variation for Direct/Indirect Lighting in a Small Office (알고리듬 변화에 따른 직/간접 조명시스템에 대한 디밍제어 효과분석)

  • Kim, Soo-Young
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.5
    • /
    • pp.36-48
    • /
    • 2008
  • This study examines the influence of control algorithms on dimming performance to determine appropriate control setting when direct/indirect lighting is controlled by a daylight dimming system. Computer simulation were performed for a small office with double skin envelope under various daylight conditions. A retractable fabric shading and Venetian blind were applied for internal and external envelopes under three CIE standard sky conditions. Unshielded and partially-shielded photosensors were used, and three control algorithms were applied for the sensors. In general, dimming level was too excessive due to the direct impact of light from lighting fixture to the photosensor. Providing insufficient lighting output, the unshielded photosensor completely failed to secure required illuminance under any daylight condition. When a partially-shielded photosensor was applied under clear sky, three setting points functioned effectively. Less sensitivity for the partially-shielded photosensor was effective to control the dimming system optimally with reasonable energy saving. However, the daylight dimming control system for direct/indirect lighting does not appear to be energy effective when photosensors without enough shielded area is installed on ceiling where light from fixtures reaches directly.

A Study on the Temperature Characteristics of the Floor Cooling System of Mock-up Experimentent (Mock-up실험에 의한 바닥복사 냉방시스템의 온도특성에 관한 연구)

  • Yoo, Ho-Chun;Lee, Young-A
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.6
    • /
    • pp.48-57
    • /
    • 2008
  • The research analyzed the distribution of the indoor temperatures of a radiant floor cooling system through mock-up experiments. It investigated the temperature difference of feed water, the vertical temperature difference of indoor air, the temperature difference of floor surface, and so on. The following is the results of the research. First, the research shows that the difference between indoor temperature and outside temperature was the smallest when the temperature of feed water was set at 16$^{\circ}C$. In addition, the temperature changes according to indoor positions (wall, room, floor, and ceiling) were the most uniform. Thus, the research found that the cold water temperature of 16$^{\circ}C$ is the most proper. In addition, it confirmed that the feed water temperature of 18$^{\circ}C$ is effective because the temperature can lower the temperature of a room to 13.55$^{\circ}C$, which is lower than the temperature of a non-cooling mode. Second, an investigation on the temperature distribution of vertical air in indoor space shows that the temperature distribution had a difference of 0.2 to 1.9$^{\circ}C$ on the average, which satisfies the range of 3.0$^{\circ}C$ in the standard of ISO.