• Title/Summary/Keyword: Standard Research

Search Result 14,363, Processing Time 0.04 seconds

The Histological Study about the Burn Caused by Moxibustion Using the Commercial Indirect Moxibustion (상용 간접구로 인한 화상에 대한 조직학적 연구)

  • Kwon, O-Sang;Lee, Sang-Hoon;Cho, Sung-Jin;Choi, Kwang-Ho;Yeon, Sun-Hee;Lee, Sae-Bom;Choi, Sun-Mi;Ryu, Youn-Hee
    • Korean Journal of Acupuncture
    • /
    • v.28 no.4
    • /
    • pp.17-28
    • /
    • 2011
  • Objectives : Burn is the important adverse effect of the moxibustion treatment. This research does with the purpose to utilize as basic data which the results of histological observation of the burn tissue which generates when operating various commercial indirect moxa (CIM) on the skin, evaluate the burn because of the surgical operation. Methods : It operated 6 kinds of CIM on the depilated abdomen of the rat. By using the H-E staining and TUNEL assay, the image was observed and analyzed. Results : It could be the moxibustion medical treatment using the CIM generated in the first degree burn until the third degree. And in some case, burn has not generated. By using the H-E stain, the second-degree burn and third degree was observed, and it was observed the first degree burn by using TUNEL assay. In the first degree burn, TUNEL reaction in the epidermal layer was confirmed. The damage to the dermal layer was observed in more than 2 degree burn. In the third degree, the tissue degeneration to the subcutaneous fat was observed but the thickness of the skin tissue was not observed. Conclusions : Basic data classifying the burn generated by the CIM treatment through the histological observation of the burn tissue caused by the CIM treatment were built according to this research result.

Analysis of Studies on Guibi-tang(Guipitang) for Fundamental Establishment of Evidence Based Medicine(EBM) (EBM 기반구축을 위한 귀비탕(歸脾湯) 연구 문헌 분석)

  • Kim, Jung-Hoon;Lee, Jun-Kyoung;Ha, Hye-Kyoung;Seo, Chang-Seob;Lee, Mi-Young;Lee, Ho-Young;Jung, Da-Young;Lee, Nam-Hun;Lee, Jin-Ah;Huang, Dae-Sun;Shin, Hyun-Kyoo
    • Journal of Oriental Neuropsychiatry
    • /
    • v.20 no.3
    • /
    • pp.205-216
    • /
    • 2009
  • Objectives : To establish the fundaments for EBM of Traditional Korean Medicine, the papers on Guibi-tang(Guipitang) which were frequently used in medical institutions of Traditional Korean Medicine were analyzed through researching domestic and international literatures. Methods : The papers were classified by the year of publishment, by experimental methods, by laboratory animals used in biological experiment and by the kinds of studies on biological efficacy. Results : Of total 39 papers were registered in domestic journals. Since 1980, publishments of papers have continuously increased. The papers on biological studies were 34 volumes, clinical studies were 5 volumes. Biological studies mainly showed the effects of anti-stress, anti-oxidant, hemostasis, anti-osteoporosis, gastroprotection, reproductive ability, brain cell activity, radioprotection. And clinical studies showed improvements of fearful throbbing, memory and orientation, insomnia, vericose vein, schizophrenia. Conclusions : Guibi-tang(Guipitang) could be used to fortify the spleen, nourish the heart and then control the blood. However biological studies need to be conducted in accordance with clinical study and further clinical studies on randomized controlled trials should be proceeded.

  • PDF

Histological study of the primo vascular system on the falciform ligament (Falciform ligament(간겸상인대)에서 관찰되는 프리모 조직의 조직학적 특성 연구)

  • Yeon, Sun-Hee;Kwon, O-Sang;Lee, Sae-Bhom;Cho, Seong-Jin;Choi, Kwang-Ho;Lee, Sang-Hun;Choi, Sun-Mi;Ryu, Yeon-Hee
    • Korean Journal of Oriental Medicine
    • /
    • v.18 no.2
    • /
    • pp.131-137
    • /
    • 2012
  • Objectives : Primo vascular system is known to new circulatory system and suggested as a anatomical structure of meridian system. Primo-vessels are present throughout the whole body. The purpose of this study is to identify primo tissues taken from falciform ligament and to compare with organ surface primo tissue, blood vessel and lymph vessel. Methods : Male Sprague-Dawley rats (8weeks old, 250~320g) used for this study. The medial line of the abdomen was dissected and searched for primo tissues in falciform ligament and on the internal organs using stereomicroscope. We performed serial cross section and histological investigations. The tissues were stained with hematoxylin-eosin and Masson's trichrome. Results : 1. The primo tissues attached on the falciform ligament had white color and length of 5~8mm. 2. We could observe primo tissues are classified with ligament tissues. 3. Histologically, primo tissue on falciform ligament and organ surface primo tissue could be considered same tissue. Conclusions : In this study, we observed primo tissue discovered on the falciform ligament. And we also histologically compared such discovered primo tissue with organ surface primo tissue. Consequently, we could consider that two tissues have histological similarity and possibility of connection in one network system.

Analysis of Studies on Samul-tang for Fundamental Establishment of Evidence Based Medicine (EBM 기반구축을 위한 사물탕 연구 문헌 분석)

  • Kim, Jung-Hoon;Lee, Jun-Kyoung;Ha, Hye-Kyoung;Seo, Chang-Seob;Lee, Ho-Young;Jung, Da-Young;Lee, Nam-Hun;Lee, Jin-Ah;Huang, Dae-Sun;Shin, Hyun-Kyoo
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.4
    • /
    • pp.779-788
    • /
    • 2009
  • To establish the fundament for EBM of Traditional Korean Medicine, the papers on Samul-tang which was frequently used in medical institutions of Traditional Korean Medicine were analyzed through researching domestic and international literatures. The papers were classified by the registration of domestic or international journals, by the year of publishment, by experimental methods, by laboratory animals used in biological experiment and by the kinds of studies on biological efficacy. Of total 67 papers on Samul-tang, 58 volumes were registered in domestic journals and 9 volumes were in international journals of which 8 volumes were in SCI journals. Since 1978, publishments of papers have continuously increased. The papers on instrumental analyses were 6, biological studies were 58 volumes, clinical studies were 3. Instrumental analyses were preceeded with standard compounds(gallic acid, albiflorin, paeoniflorin, benzoic acid, ferulic acid, 5-HMF). And biological studies showed improvement of cardiovascular function and circulation, antianemia, brain protection, immunoregulation, antistress, radioprotection, antifatigue, antiinflammation and antiallergy, antioxidative effect. Through clinical studies, antifatigue, improvement of insomnia and osteoporosis were reported. Samul-tang could be used to tonify and activate blood. And further study on clinical field need to be conducted in accordance with biological study.

The Multi-channel Bio-potential Similarity Research of Acupuncture Point (ST36) and Peripheral Region (다채널 생체전위 측정을 통한 족삼리 주변 피부의 전위 변화 유사도 연구)

  • Lee, Sang-Hun;Cho, Sung-Jin;Choi, Gwang-Ho;Ryu, Yeon-Hee;Kwon, O-Sang;Choi, Sun-Mi
    • Korean Journal of Acupuncture
    • /
    • v.28 no.4
    • /
    • pp.41-48
    • /
    • 2011
  • Objectives : This study aimed to explore the passive multi-channel time series analysis method by measuring bio-potentials of acupuncture point and the peripheral region Methods : Bio-potential was measured at ST36 and the peripherical region of ST36 of 5 healthy volunteers at three times. The diagram of the potential changes over time were smoothed by moving average method and similarities of ST36 and the other points were calculated. Results : In the normal weight group, bio-potential similarity tended to decrease in proportion to the distance from the acupuncture point. In the obesity group, bio-potential similarity appeared in a very wide area. Bio-potential similarity had positive correlation with BMI value. Conclusions : The passive multi-channel time series analysis method showed the possibility be appropriate for the electrical characteristics study of meridians.

Setup of standard PD calibrator and its uncertainties

  • Kim, Kwang-Hwa;Yi, Sang-Hwa;Lee, Heun-Jin;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.677-683
    • /
    • 2011
  • The present paper describes the setup of standard partial discharge calibrator for measuring partial discharge and estimating uncertainties. The standard PD calibrator was designed and set up, consisting of a digital pulse generator, capacitor modules, and a digital oscilloscope controlled by software developed in the laboratory. Using this software, averages of charges and rising times and their standard deviations in the measured pulses can also be calculated. The standard PD calibrator generates five types of pulses: single, double, random, oscillating, and long-rising. The coefficient sensitivities to estimate the uncertainties of pulses were extracted in the model circuit of the standard PD calibrator. The uncertainties of charges and rising times in pulses of the standard PD calibrator were estimated with single pulses. These values were 0.3%-1.4% in charges and 1.9%-7.0% in rising time; however, these values are lower than the limit values in IEC 60270.

Measurement of Solar Cell Using LED-based Differential Spectral Responsivity Comparator under High Background Irradiance

  • Zaid, Ghufron;Park, Seong-Chong;Lee, Dong-Hoon;Park, Seung-Nam
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2009.02a
    • /
    • pp.293-294
    • /
    • 2009
  • The spectral responsivity of solar cells has been measured under high background irradiance using an LED-based differential spectral responsivity Comparator (DSR-C). The comparator developed is fully automated and has some advantages: It does not need a chopper to modulate the light. Unlike the conventional method, it does not require a monochromator to select wavelength. It covers a wavelength range up to 1200 nm. The wavelength range of the comparator is limited by the spectral power distribution of the LEDs and the spectral responsivity of the standard detector. An active temperature control was utilized to meet the specified standard conditions of solar cell test. This work shows the effect of different levels of background irradiance on the spectral responsivity and the importance of same background irradiance for solar cell test as specified by the corresponding standard.

  • PDF

Standard sand for geotechnical engineering and geoenvironmental research in Nigeria: Igbokoda sand

  • Ojuri, Oluwapelumi O.;Fijabia, David O.
    • Advances in environmental research
    • /
    • v.1 no.4
    • /
    • pp.305-321
    • /
    • 2012
  • This study entails establishing reference standard sand in Nigeria for engineering and geoenvironmental research work. Sands from four geographical locations in southwestern Nigeria were examined for baseline geotechnical and mineralogical properties. A total of sixteen sand samples were collected. The samples were air dried and subjected to tests in accordance with standard specifications. The tests carried out were: specific gravity, grain size analysis, moisture content, bulk density, porosity, void ratio, chemical analysis, X-ray diffraction and Differential Thermal Analysis. The properties of the samples were compared with a standard (Ottawa sand in Illinois of the United States) in order to find out which of the four samples selected from southwestern Nigeria could serve as standard baseline sand. The results show that Igbokoda sand has geotechnical and mineralogical characteristics closest to Ottawa sand. It was therefore concluded that Igbokoda sand could be used as a standard baseline sand for research work in southwestern Nigeria and other parts of Nigeria since it needs little processing to bring it to the same level as standard baseline sand, like the Ottawa sand.