• Title/Summary/Keyword: Standard Profile

Search Result 630, Processing Time 0.021 seconds

The Relation between the Phase-Shift Profile for the Intermediate Frequencies and the Langmuir Adsorption Isotherm (중간주파수에서 위상이동 변화와 Langmuir흡착등온식 사이의 관계)

  • Chun Jang Ho;Mun Kyeong Hyeon;Cho Chong Dug
    • Journal of the Korean Electrochemical Society
    • /
    • v.3 no.1
    • /
    • pp.25-30
    • /
    • 2000
  • The relation between the phase-shift profile for the intermediate frequencies and the Langmuir adsorption isotherm at the poly-$Pt/0.1\;M\;H_2SO_4$ aqueous electrolyte interface has been studied using ac impedance measurements, i.e., the phase-shift methods. The suggested interfacial equivalent circuit consists of the serial connection of the electrolyte resistance ($R_S$), the faradaic resistance $(R_F)$ and the equivalent circuit element $(C_P)$ of the adsorption pseudocapacitance $(C_\varphi)$. The delayed phase shift $(\varphi)$ depends on both the cathode potential (E) and frequency (f), and is given by $\varphi=-tan^{-1}[1/2{\pi}f(R_s+R_F)C_p]$. The phase-shift profile $(\varphi\;vs.\;E)$ for the intermediate frequency (ca. 6Hz) can be used as an experimental method to determine the Langmuir adsorption isotherm (9 vs. E). The equilibrium constant (K) for H adsorption and the standard free energy $({\Delta}G_{ads})$ of H adsorption at the poly-$Pt/0.1\;M\;H_2SO_4$ electrolyte interface are $1.8\times10^{-4}\;and\;21.4kJ/mol$, respectively. The H adsorption is attributed to the over-potentially deposited hydrogen (OPD H).

Development of Indentation Training System for Pulse Diagnosis (맥진 가압 트레이닝 시스템 개발)

  • Lee, Jeon;Lee, Yu-Jung;Jeon, Young-Ju;Woo, Young-Jae;Kim, Jong-Yeol
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.45 no.6
    • /
    • pp.117-122
    • /
    • 2008
  • Although the pulse diagnosis is the one of the most important diagnostic process to traditional medical doctors, there is no proper communication tool between experts and trainees. In this paper, we have developed a indentation training system which consists of a hardware measuring indent pressure on artificial arm quantitatively and a software providing a indentation training program. The hardware for measurement of indent pressure profile includes 3 load cells embedded in the artificial arm, signal amplification part and digitization part, NI-USB 6009 with 200Hz sampling rate. For setting up a relationship table between weights and output voltages, 8 standard weights were used. To evaluate this hardware, 3 oriental medical specialists were involved and their indent pressure profile were recorded three times respectively. From these, it was found that pulse diagnosis process could be divided into 3 periods and the maximum load were $500g{\cdot}f$ approximately while doctors perform a pulse diagnosis. The indentation training program was implemented with LabView and designed to monitor the differences between the pressure profile of a expert and that of a trainee so to offer some visual feedback to the trainee. Also, this program could provide the trends of training performances. With this developed system, the education of pulse diagnosis is expected to be more quantitative and effective.

Application of linear-array microtremor surveys for rock mass classification in urban tunnel design (도심지 터널 암반분류를 위한 선형배열 상시진동 탄성파 탐사 적용)

  • Cha, Young-Ho;Kang, Jong-Suk;Jo, Churl-Hyun
    • Geophysics and Geophysical Exploration
    • /
    • v.9 no.1
    • /
    • pp.108-113
    • /
    • 2006
  • Urban conditions, such as existing underground facilities and ambient noise due to cultural activity, restrict the general application of conventional geophysical techniques. At a tunnelling site in an urban area along an existing railroad, we used the refraction microtremor (REMI) technique (Louie, 2001) as an alternative way to get geotechnical information. The REMI method uses ambient noise recorded by standard refraction equipment and a linear geophone array to derive a shear-wave velocity profile. In the inversion procedure, the Rayleigh wave dispersion curve is picked from a wavefield transformation, and iteratively modelled to get the S-wave velocity structure. The REMI survey was carried out along the line of the planned railway tunnel. At this site vibrations from trains and cars provided strong seismic sources that allowed REMI to be very effective. The objective of the survey was to evaluate the rock mass rating (RMR), using shear-wave velocity information from REMI. First, the relation between uniaxial compressive strength, which is a component of the RMR, and shear-wave velocity from laboratory tests was studied to learn whether shear-wave velocity and RMR are closely related. Then Suspension PS (SPS) logging was performed in selected boreholes along the profile, in order to draw out the quantitative relation between the shear-wave velocity from SPS logging and the RMR determined from inspection of core from the same boreholes. In these tests, shear-wave velocity showed fairly good correlation with RMR. A good relation between shear-wave velocity from REMI and RMR could be obtained, so it is possible to estimate the RMR of the entire profile for use in design of the underground tunnel.

Development of Profile Technique for Steam Generator Tubes in Nuclear Power Plants Using $8{\times}1$ Multi-Array Eddy Current Probe ($8{\times}1$ 다중코일 와전류탐촉자를 이용한 원전 증기발생기 전열관 단면형상검사 기법 개발)

  • Nam, Min-Woo;Lee, Hee-Jong;Kim, Cheol-Gi
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.28 no.2
    • /
    • pp.184-190
    • /
    • 2008
  • Various ECT techniques have been applied basically to assess the integrity of steam generator tithing in nuclear power plant. Among these techniques, the bobbin probe technique is applied generally to examine the volumetric flaws such as a crack-like defect and wear which is generally occurred on steam generator tubing, and additionally MRPC probe is used to examine closely tile top of tubesheet and bending regions due to the high possibility of cracking. Dent and bulge also may be formed on tube during installation process and operation of steam generator, but the dent and bulge indications greater than specific size criteria are recorded on examination report because these indications are not considered as flaw. These indications can be easily detected with bobbin probe and approximately sized with profile bobbin probe, but the size and shape can not be accurately verified. Accordingly, in this study, the $8{\times}1$ multi-array EC probe was designed to increase the measurement accuracy of the sectional profiling EC testing of tube. As a result, we would like to propose the application of $8{\times}1$ multi-array EC probe for the measurement of size and shape of profile change on steam generator tube in OPR-1000 nuclear power plant.

Design and Implementation of Plannar S-DMB Antenna with Omni-Directional Radiation Pattern Using Metamaterial Technique (메타 물질 기법을 이용한 전방향성 복사 패턴을 갖는 평면형 S-DMB 안테나 설계 및 구현)

  • An, Chan-Kyu;Yu, Ju-Bong;Jeon, Jun-Ho;Kim, Woo-Chan;Yang, Woon-Geun;Nah, Byung-Ku;Lee, Jae-Ho
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.12
    • /
    • pp.1343-1351
    • /
    • 2010
  • In this paper, a novel patch antenna based on the metamaterial CRLH(Composite Right- and Left-Handed) structure is designed, implemented, and measured. Contrary to the standard microstrip patch's fundamental resonance mode of half-wavelength or its positive multiple, the proposed antenna shows the in-phase electric field over the entire antenna. The proposed antenna has a desired omni-directional field pattern which is typical characteristic of $\lambda/4$ monopole antenna, and also shows the merit of low profile. HFSS(High Frequency Structure Simulator) of Ansoft which is based on the FEM(Finite Element Method) is used to simulate the proposed antenna. FR-4 substrate of thickness 1.6 mm and relative permitivity 4.4 is used for the proposed antenna implementation. The implemented antenna showed VSWR (Voltage Standarding Wave Ratio)$\leq$2 for the frequency band from 2.63 GHz to 2.655 GHz which is used for S-DMB (Satellite-Digital Multimedia Broadcasting) service. And measured peak gain and efficiency are 2.65 dBi and 81.14 %, respectively.

Cone-beam computed tomographic analysis of the alveolar ridge profile and virtual implant placement for the anterior maxilla

  • Lim, Hyun-Chang;Kang, Do-Uk;Baek, Hyehyeon;Hong, Ji-Youn;Shin, Seung-Yun;Chung, Jong-Hyuk;Herr, Yeek;Shin, Seung-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.49 no.5
    • /
    • pp.299-309
    • /
    • 2019
  • Purpose: To analyze the ridge profile of the anterior maxilla using cone-beam computed tomography and to assess the clinical significance of the ridge profile by performing virtual implant placement. Methods: Thirty-two cone-beam computed tomography scans of anterior maxillae were included. For each tooth, a vertical line was made along the longitudinal axis, and 3 horizontal lines at 1-, 3-, and 5-mm levels below the labial bone crest were drawn perpendicularly to the vertical reference. At these levels, the thickness of the alveolar ridge (RT), and the labial (LT) and palatal bone plate (PT) were measured. Then, virtual implant placement using standard and tapered implants was performed. A generalized linear mixed model was used for statistical analysis. Results: The teeth were located labially based on the proportion of LT and PT with respect to RT. At the 1-mm level, the value of LT was between $1.0{\pm}0.4mm$ for central incisors and $1.3{\pm}0.6mm$ for canines. A large number of teeth had area(s) with less than 1-mm-thick labial bone between the 1- and 5-mm levels below the crest. The mean PT was generally thicker than the LT in all tooth types. The greatest mean value of labial concavity was observed for canines, compared to other tooth types. Men had a greater RT than did women, but had a comparable LT. Less apical fenestration was observed when tapered implants were used. Conclusions: Most teeth in the anterior maxilla had a thin labial bone plate, with no significant difference between sexes. Tapered implants may be advantageous for the anterior maxilla.

Prediction of speaking fundamental frequency using the voice and speech range profiles in normal adults (정상 성인에서 음성 및 말소리 범위 프로파일을 이용한 발화 기본주파수 예측)

  • Lee, Seung Jin;Kim, Jaeock
    • Phonetics and Speech Sciences
    • /
    • v.11 no.3
    • /
    • pp.49-55
    • /
    • 2019
  • This study sought to investigate whether mean speaking fundamental frequency (SFF) can be predicted by parameters of voice and speech range profile (VRP and SRP) in Korean normal adults. Moreover, it explored whether gender differences exist in the absolute differences between the SFF and estimated SFF (ESFF) predicted by the VRP and SRP. A total of 85 native Korean speakers with normal voice participated in the study. Each participant was asked to perform the VRP task using the vowel /a/ and the SRP task using the first sentence of a Korean standard passage "Ga-eul". In addition, the SFF was measured with electroglottography during a passage reading task. Predictive factors of the SFF were explored and the absolute difference between the SFF and the ESFF (DSFF) was compared between gender groups. Results indicated that predictive factors were age, gender, minimum pitch and pitch range for the VRP (adjusted $R^2=.931$), and pitch range (in semi-tones) and maximum pitch for the SRP (adjusted $R^2=.963$), respectively. The SFF and ESFF predicted by the VRP and SRP showed a strong positive correlation. The DSFF of the VRP and SRP, as well as their sum did not differ by gender. In conclusion, the SFF during a passage reading task could be successfully predicted by the parameters of the VRP and SRP tasks. In further studies, clinical implications need to be explored in patients who may exhibit deviations in SFF.

Evaluation of Structural Robustness of External Fuel Tank and Pylon for Military Aircraft under Random Vibration (랜덤진동에서 군용 항공기 외부연료탱크 및 파일런 구조 강건성 평가)

  • Kim, Hyun-Gi;Kim, Sungchan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.3
    • /
    • pp.777-783
    • /
    • 2021
  • Aircraft are affected by various vibrations during maneuvering. These vibrations may have a fatal effect on the survival of aircraft in some cases, so the safety of components applied to the aircraft should be proven against various vibrations through random vibration analysis. In this study, the structural robustness of an external fuel tank and pylon for military aircraft was evaluated under random vibration conditions using commercial software, MSC Random. In the random vibration analysis, a frequency response analysis was performed by imposing a unit load on the boundary condition point, and then excitation was performed with a PSD profile. In this process, the required mode data was extracted through a modal analysis method. In addition, the random vibration profile specified in the US Defense Environment Standard was applied as random vibration conditions, and the PSD profile given in units of G's was converted into units of gravitational acceleration. As a result of the numerical analysis, we evaluated the structural robustness of the external fuel tank and pylon by identifying the safety margins of beam elements, shell elements, and solid elements in a numerical model for random vibration in the x, y, and z directions.

A Comparative Study of Sensory Processing Abilities and Visual Perception Skills in Children With Attention Deficit Hyperactivity Disorder and Typical Children (ADHD 아동과 일반 아동의 감각처리능력과 시지각 기술의 비교 연구)

  • Ju, Jin-Ok;Kim, Kyeong-Mi
    • The Journal of Korean Academy of Sensory Integration
    • /
    • v.18 no.3
    • /
    • pp.1-13
    • /
    • 2020
  • Objective : The purpose of this study was to evaluate the differences in sensory processing and visual perception between school-age children with Attention Deficit Hyperactivity Disorder (ADHD) and typical children. Methods : The participants in this research were children in the first and second grade in elementary school in Kyoung-Nam Region; 25 children diagnosed with ADHD comprised the experimental group, and 51 typical children comprised the control group. To evaluate the sensory processing of the children, the Sensory Profile (SP) was used, and the Korean Developmental Test of Visual Perception-2 (K-DTVP-2) was used to assess visual perception skills. The data were analyzed using SPSS 20.0, and the Independent t-test was used to compare the sensory processing and visual perception skills of the two groups. Results : The study found differences in the Sensory Profile summary scores and factor summary scores between the two groups (p<.05). We also found differences in the visual perception index and subtest standard scores between the two groups (p<.05). Conclusion : The results of this study show that the experimental and the control groups had significant differences in sensory processing and visual perception skills. The result will contribute to the assessment and education of children with ADHD.

An Interoperable Mapping Model between SEP 2.0 & OpenADR 2.0b for ICT Grid Convergence (ICT 전력 융합을 위한 SEP 2.0과 OpenADR 2.0b간의 상호운용 매핑 모델)

  • Choi, Min-Young;Lee, June-Kyoung;Lee, Kyoung-Hak
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.8
    • /
    • pp.41-49
    • /
    • 2017
  • The 'NIST Framework and Road Map for Smart Grid Interoperability Standards' proposes an architecture framework to secure the direction of development and standard interoperability of smart grid and provides a list of identified standard, standard cyber security strategies, and certification framework. In particular, SEP 2.0 and OpenADR 2.0 are the examples. SEP 2.0 and OpenADR 2.0 can functionally link HEMS and Smart Grid, but interoperability standards between the two protocols are not planned in above document. The OpenADR Alliance also announced that work is underway to define mapping tables for interoperability between OpenADR 2.0 and SEP 2.0, but no information is yet available. Therefore, In this paper, in developing energy efficiency improvement HEMS, we propose a mapping model that supports syntactic and semantic founded interoperability between SEP 2.0 and OpenADR 2.0b for ICT grid convergence based on the standard specification document of each protocol and confirmed through an example of the semantic mapping function based on the demand response service scenario.