• Title/Summary/Keyword: Standard Of Procedure

Search Result 1,933, Processing Time 0.031 seconds

An experimental study on the rating of noise emission from water supply and drain installations in apartment bathroom (공동주택 욕실 급배수음 평가방법 제정방안에 관한 실험적 연구)

  • Lee, Tai-Gang;Song, Min-Jeong;Jang, Gil-Soo;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.5-10
    • /
    • 2006
  • This study aims to propose appropriate evaluating method of noise emission from water supply and drain installations in apartment bathroom. Because KS(Korean Standard) about water installations noise in apartment bathroom only are establishing the measurement procedure of it, Evaluation and rating procedure is necessary to improve the sound insulation performance of the apartment and to reduce the apartment dweller's unsatisfaction with the noise. Thus, this study reviewed the standards and evaluating methods about the water supply and drain installations noise of many other country. We measured the noise emission from the installations in many apartment bathroom, and then we calculated the noises to dB(A), N, NC evaluated numbers. We analyze the coefficient of the corelation among the evaluated numbers to induce the appropriate method. As a result, the dB(A) method is most easy to evaluateing and very high corelated wth N and N index, So the dB(A) method is suitable to be adopted KS evaluating procedure of noise emission from water installations in apartment bathroom.

  • PDF

Generation of the Battlefield in Distributed Simulation System Based on Synthetic Environment Representation and Interchange Standard (SEDRIS) (분산 시뮬레이션 시스템에서 합성 환경 표현 및 교환 표준(SEDRIS) 기반의 전장 환경 구축)

  • Hwam, Won Kyoung;Kim, Jung-Hoon;Na, Young-Nam;Cheon, Sang Uk;Park, Sang C.
    • Journal of Information Technology and Architecture
    • /
    • v.9 no.3
    • /
    • pp.253-263
    • /
    • 2012
  • Presented in the paper is a methodology for the distributed simulation of underwater warfare based on standard synthetic environment. In the case of underwater warfare simulation, it is very important to reflect environmental data, such as salinity and temperature. For the reusability and interoperability of environmental data, this paper adopts Synthetic Environmental Data Representation and Interchange Specification (SEDRIS(ISO standard for environmental data)). Although SEDRIS provides various merits as an international standard, applying of SEDRIS has been hindered by its broadness and heaviness. To relieve the difficulties, this paper proposes an efficient procedure to utilize SEDRIS technology for the atmosphere and underwater environment. This paper identifies SEDRIS structure for the atmosphere/underwater structured dimensional grid-based and implements the proposed procedure on the High Level Architecture (HLA) / Run-Time Infrastructure (RTI) to explain the generation of the battlefield in a distributed simulation system.

Commercial Grade Item Dedication of Digital Devices for Safety-related System in Nuclear Power Plant (원자력발전소 안전등급 계통 적용을 위한 디지털 상용기기 품질검증)

  • Hong, Young Hee;Bae, Byung Hwan;Park, Jaehyun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.63 no.12
    • /
    • pp.1637-1639
    • /
    • 2014
  • In the past, the analog protection relays have been widely used for the safety-related systems in the nuclear power plants due to their stability and reliability. Meanwhile, as the high performance digital system has been developed, the digital systems have been adopted in the non-safety systems. However, since the digital systems currently used in the non-safety systems were not developed according to Q-class standard, Commercial Grade Item Dedication (CGID) procedure should be performed in order to apply them to the safety-related system. The purpose of this paper is to describe the CGID procedure including the analysis of the hardware architecture as well as the software embedded in protective relay to apply to the emergency diesel generator in the nuclear power plant. The entire CGID procedure was performed strictly according to the international standard and regulations.

A Study on the Measurement Uncertainty of Flowmeter Calibrator (유량계 교정장치의 측정불확도에 관한 연구)

  • Im, Gi-Won
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.4
    • /
    • pp.561-571
    • /
    • 2001
  • The standard uncertainty of flowrate measurement is obtained by combining that of independent variables. Gravimetric and volumetric method were applied to determine the flowrate and the standard uncertainties of flowrate measurement by both methods were evaluated in accordance with the procedure recommended by International Organization for Standardization. The combined standard uncertainties of determining the flowrate were estimated from the sensitivity coefficient and the standard uncertainty of independent variables. For practical application, the methods for evaluating and expressing uncertainty in flow measurement were discussed. It was found that the uncertainties of the weighing and time measurement in gravimetric method, the volume and time measurement in volumetric method have dominant influence on that of flowrate measurement. With the quantitative analysis of the sensitivity coefficient, the contribution of the each variable uncertainty to the combined standard uncertainty of flowrate measurement is shown clearly.

Determination of ampicilin and colxacilin mixture by NMR

  • Shin, Moon-Hee;Park, Man-Ki;Yu, Chang-Hwa;Choi, Jung-Kap
    • Archives of Pharmacal Research
    • /
    • v.4 no.1
    • /
    • pp.9-17
    • /
    • 1981
  • A simple, accurate and specific NMR procedure is described for the determination of amplicilin and cloxacillin mixtures in injection dosage form and capsules. The solvent was dimethysulfoxde $d_{6}$ and maleic acid was the internal standard. By integrating the peak at 2.68 ppm and 4.57 ppm, cloxacillin and ampicillin could be determined respectively. The relative proton ratio of ampicillin trihydrate and cloxacillin were 1.038 and 0.950. The coefficents of variation of amplicillin trihydrate and cloxacillin in a few commerical preparation were 1.55 % (n =9), 2.69 % (n =15).

  • PDF

Output Behavior of Build-Up Force Measuring System (BUILD-UP 힘측정 시스템의 출력거동)

  • 강대임;송후근;홍창선
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.9
    • /
    • pp.2194-2205
    • /
    • 1995
  • In order to reduce the systematic error of a build-up system, we have proposed a new test procedure in which all force transducers in a build-up system are rotated by 90.deg. with a base platen fixed on a force standard machine. The setting positions of force transducers on the output of a build-up system were investigated using an orthogonal array. The effects of the parallelism of a build-up system and of the bending moment sensitivity of a force transducer were considered. The experimental results show that the setting position of the base platen hardly affects the output of the build-up system, but the setting positions of force transducers affects it strongly. It reveals that the new test procedure reduces effectively the systematic error of a build-up system.

Development of a Supporting Program for the Emergency Preparedness Plan (사고대비물질 취급자의 비상대응계획 작성 프로그램 연구)

  • Kim, Sung-Bum;Noh, Hye-Ran;Seok, Gwang-Seol;Park, Jae-Deuk
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.5
    • /
    • pp.54-58
    • /
    • 2011
  • Emergency preparedness plan(EPP) is the systematic management of activities that involve a material degree of risk of loss or other damage to the surroundings(people, property and environment), and the boundary of accident recovery plan(ARP). The main purpose of the program is to provide a safety management system to each facility in order to enable to prevent accident and to control accident immediately. The EPP includes not only typical safety-related documentations such as material safety data sheet(MSDS), standard operation procedure(SOP), emergency response plan(ERP). EPP is established basis of the preliminary safety analysis involving risk identification, assessment and prevention plans. The program is also helpful for government or related agencies to control a number of accidents in small-scale companies in the whole country.

The Change of Inspection&Replacement Period for ROKAF's Operating Aircraft Parts (한국공군 운영 항공기 부품 검사/교환주기 변경 - 예방정비 대책 품질개선의 일환으로 -)

  • Kwo Seung-Chul
    • Journal of the military operations research society of Korea
    • /
    • v.30 no.2
    • /
    • pp.108-121
    • /
    • 2004
  • This paper deals with a procedure of changing the current inspection & replacement periods for ROKAF aircraft parts. ROKAF is mostly operating aircraft of foreign makes, and takes maintenance actions according to Technical Orders(TO.) published by foreign aircraft manufacturers. Therefore ROKAF inspects and replaces specific parts at the time noticed from T.O.. These inspection and replacement periods are determined by manufacturers according to the standard operating environment and parts' durability. But the standard operating environment Is different from operator's environment. Because of this difference, the inspection and replacement periods have to be changed according to operators' operation environment. It is resonable that the manufacturer, having design materials and life test data of parts, changes those periods together with materials of operators' operation environment. But we have many difficulties in obtaining the design materials and life test data. Then this paper proposes a procedure of changing the periods of aircraft's parts with life data obtained during operating aircraft. For the reliability analysis, a software of RELEST (Reliability Estimation Version 1.0) is used.

Test method for Motor/controller for Electric Vehicle (전기자동차용 전동기/제어기의 시험 방법)

  • 오성철
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.4
    • /
    • pp.328-335
    • /
    • 2003
  • Test procedure for Electric Vehicle(EV) motor/controller has been developed. Most of existing standards mainly focus on minimum requirements for safe operation. However, detailed test procedures are not covered in the standard. In order to develop test items, methods and procedures which should be strictly applied to EV motor and controller, existing standards have been reviewed by the expert group in Korea. Based on their feedback, standard test procedure was proposed. Test procedure especially for combined motor and controller has been proposed. As a load lot the tested motor, M-G set, eddy current type engine dynamo and AC dynamo were used. Test procedures for the driving cycle test and regeneration test were proposed.

Design of Quality Metrics and Accreditate Procedure for SW Process Improvement based on K-model (K-모델기반의 소프트웨어 프로세스 품질 척도 및 인증절차 설계)

  • Hwang, Sun-Myung
    • Journal of Advanced Navigation Technology
    • /
    • v.13 no.6
    • /
    • pp.861-875
    • /
    • 2009
  • In order to make high quality software and high reliability software, systematic development management and organizational support are essential needed. Since 1990's Software process models such as ISO/IEC 15504 and CMMI have been used to improve organization capability. But these models have problems that are used to apply on large scaled organization or large project and so many practices are actually required. We present characteristics of ISO/IEC 15504, CMMI and K-model can easily apply to small and medium sized business or project, and propose the standard quality metric and accreditate procedure based on K-model for measuring quantitative quality level.

  • PDF