• 제목/요약/키워드: Standard Of Procedure

검색결과 1,933건 처리시간 0.033초

치조제확대골절단술(RIDGE EXPANSION OSTEOTOMY)을 이용한 임프란트의 매식 (PLACEMENT OF IMPLANTS BY THE USE OF RIDGE EXPANSION OSTEOTOMY PROCEDURE)

  • 오희균
    • 대한치과의사협회지
    • /
    • 제34권3호통권322호
    • /
    • pp.215-222
    • /
    • 1996
  • Ridge expansion osteotomy(REO) procedure is used to widen the narrow ridge in locations that are too thin to permit the use of standard implant drills. The objective of this technique is to maintain, if possible, all of the existing maxillary bone by pushing the bone aside with minimal trauma. The author has used tis procedure on five patients who had narrow ridge in their soft maxillary bone. Fifteen implants were placed in sites needing ridge expansion using REO. The satisfactory results were obtained. The REO procedure is thought to be a safer and more conservative method of widening a narrow ridge. And this procedure is heatless, offers excellent tactile sensitivity, control, visibility, and takes advantage of available bone.

  • PDF

선진각국의 내화설계법에 관한 연구 (A Study on Fire Resisting Construction Design in Advanced Nation)

  • 김화중
    • 한국화재소방학회논문지
    • /
    • 제2권2호
    • /
    • pp.17-30
    • /
    • 1988
  • In Our Country, the fire safety design is done by the standard furnace fire test. This is haphazard procedure, as the standard furnace fire endurance of structural elements has little relation to the structural element endurance in an actual Compartment fire. The standard furnace fire test results, though obtained at great cost, do not contribute to the understanding of the behavior of structural elements in an elevated temperature environment and can not be applied rationally in fire safety design. The response of a steel and reinforced concrete structure in fire is a very complex problem. Therefore, in this paper is explained about tendency of study for fire safety design in advanced nations.

  • PDF

다품종 극소량생산시 표준시간자료의 산정방법 및 적용사례 (An Estimation Method of Standard Time Data and a Case Study in Multi-Item Extremely Small Quantity Production)

  • 심창건;변재현
    • 산업공학
    • /
    • 제11권2호
    • /
    • pp.191-197
    • /
    • 1998
  • Having a reliable standard time data is very important for productivity improvement of any manufacturing company. In this study we present an estimation procedure of standard time data for companies having multi-item extremely small quantity production type and discuss a case study. Included in the discussion are the importance of setup time reduction and the roles of management supervisors, and labor.

  • PDF

공정용 컴퓨터를 위한 표준시각 수신장치 개발에 관한 연구 (A study on the development of standard-time receiving device for process computer)

  • 홍용표;손창호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국내학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.592-596
    • /
    • 1988
  • PCS(Process Computer System) is installed to monitor various kinds of process parameters in Power Plant and networked for synthetic monitor and event analysis in all site. But when an event is occured sequentially or simultaneously among the plants, it is difficult to analyze it because of different Standard-Time in each Plant. Standard-Time Receiving Device is developed to solve this problem and development procedure is descried here.

  • PDF

비만관 유량계 교정 시스템 구축에 관한 연구 (Study on the Calibration System of Flow Meters in Partly Filled Pipes)

  • 유성호;이동락;이민수
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.141-146
    • /
    • 2005
  • Flow meters in partly filled pipes are set up and run in Korea now days, but there are no standard calibration procedures for the flow meters in accordance with ISO/IEC 17025, the standard calibration procedure based on the standard calibration procedures for flow meter in closed conduits and the technical notes of flow meter's makers is developed. the measurement uncertainty of the calibration for the flow meter in partly filled pipes is evaluated.

  • PDF

국방정보기술표준 일반 표준적합성시험 프레임워크 및 방법론 연구 (A Study on General-Standard Conformance Test Framework and Methodology of Defense Information Technical Standard)

  • 서민우
    • 한국군사과학기술학회지
    • /
    • 제19권6호
    • /
    • pp.744-751
    • /
    • 2016
  • Interoperability tests are required to determine whether network-based defense systems successfully share and exchange certain services, information, and data. We must examine various aspects of interoperability. The DITA (Defense Information Technical stAndard) is the basis for interoperability. However, DITA is being applied to the defense system in a state that the standard test methods and procedures are not established. And there is no test method and procedure of the DITA well applicable to military weapons systems or information systems. Therefore, in this paper, we propose a framework that includes procedures, methodologies, so as to test whether a standard is applied to the DITA in terms of Standard Conformance Test.

중풍변증표준안 진료기록부 임상적용을 위한 증례기록부와 표준작업지침서의 개선과정 (Improvement of Tentative Korean Standard Differentiation of the Symptoms and Signs for Stroke for Clinical Application)

  • 이민구;강병갑;김보영;고호연;최선미;설인찬;조현경;윤종민;문병순;이인
    • 동의생리병리학회지
    • /
    • 제21권1호
    • /
    • pp.347-351
    • /
    • 2007
  • This study was done to report the improvement of second case report form(CRF) and standard operating procedure(SOP) of Tentative Korean Standard Differentiation of the Symptoms and Signs for Stroke. We were in charge of developing case report form(CRF) and educating the investigators. In the process of this project, we needed to develop standard operating procedure(SOP) for this CRF. So we made Tentative Korean Standard Differentiation of the Symptoms and Signs for Stroke and tried clinical application at Department of Oriental Internal Medicine of Wonkwang University and Daejeon University in 2005. And in this pilot study we can find out some problems and need to improve it. We strengthen the incision and exclusion criteria of CRF We canceled the Chief complains entry for efficiency. We reflected the decision of Stroke standard committee. We reduced the differentiation index of CRF to promote efficiency and accuracy. We rearranged the order of the differentiation index to promote rationality and practicality. We regulated detail item belonging to Differentiation index. We used a colloquialism in question. We inserted flow chart in SOP. We inserted picture of diagnostic index.

한방병원의 봉약침 시술 동의서의 사용 현황과 표준 시술 동의서 개발에 대한 제안 (Usage of informed consent form for Bee-venom pharmacopuncture Therapy at korean medicine hospitals and Proposal for development of a standard informed consent form.)

  • 김민정
    • 대한한의학회지
    • /
    • 제41권3호
    • /
    • pp.66-80
    • /
    • 2020
  • Objectives: We investigated the current status of the consent form for bee-venom pharmacopuncture therapy, which is using in Korean medicine hospitals. We suggest the development of a standard informed consent form. Method: Through the questionnaire survey, status of using informed consent form was identified at 24 Korean medicine hospitals. We analyze different types of informed consent form, which was developed by each hospitals. We investigated the types of informed consent forms for various medical procedures through electronic searches. A standard informed consent form for bee-venom pharmacopuncture therapy was developed based on the medical law and the standard informed consent form for medical procedures developed by Korea Fair Trade Mediation Agency. Result: In our survey, 65% of the hospitals do not use consent well, only 35% of the hospitals use informed consent form, and the most hospitals use self-developed informed consent form. As a result of analyzing the contents of informed consent form used in each hospitals, the explanation of diagnosis, treatment precautions, suggestions for other treatments, consequences of not performing the scheduled procedure, possibility of treatment change was insufficient. 48% of hospitals manage consent in recording on a chart, 39% in scanned documents, and 13% in digital electronic consent form. Conclusion: A standard informed consent form for Bee-venom pharmacopuncture therapy include diagnosis, effectivness, necessity, indications, method, skin reaction test, hypersensitivity questionnaire, treatment precautions, possible hypersensitivity reactions and countermeasures, suggestions for other treatments, consequences of not performing the scheduled procedure, possibility of treatment change and the name of doctor.

WROUGHT WIRE CLASP의 물리적 성질에 관한 실험적 연구 (AN EXPERIMENTAL STUDY ON PHYSICAL PROPERTIES OF WROUGHT WIRE CLASP)

  • 이광희;장익태;김광남
    • 대한치과보철학회지
    • /
    • 제27권2호
    • /
    • pp.201-218
    • /
    • 1989
  • The purpose of this study was to evaluate the influence of attachment technique on mechanical properties and microstructures of wrought wires. The wires tested in this study were precious metal wires: PGP (Platinum-Gold -Palladium), Elastic #12, Denture Clasp, Standard, Jelenko No. 2, Degulor-Klammerdraht, DM (Dong Myung) and base metal wire : Ticonium. Each wire was divided into three groups, and each group was heat treated as embedding, cast to, and soldering state. Heat treated sample was evaluated by tensile test, bending test, microhardness test, element analysis and microstructure test. The obtained results were as follows: 1. In tensile test, cast to and soldering procedures have an effect on wrought wire clasp as hardening heat treatment. 2. Maximum bending strength was significantly increased in Elastic #12, Denture Clasp, Standard, and DM in cast to procedure. 3. Ticonium showed the highest Victors hardness number, followed by PGP, and there was no significant difference in other wrought wires. In cast to and soldering procedure, Victors hardness number was significantly increased in precious wrought wires. 4. The precious wrought wire showed typical fibrous structure and this was disappeared in cast to and soldering procedure. But physical properties were not influenced by this phenomenon.

  • PDF

일정구속압력 다단계삼축압축시험 (Multi -Stage Triaxial Test under Constant Confining Pressure)

  • 김상규;김현태;김호일
    • 한국지반공학회지:지반
    • /
    • 제9권2호
    • /
    • pp.27-40
    • /
    • 1993
  • 한 개의 공시체에 대해 일정한 크기의 높은 구속압력을 가하고, 단계별로 압밀배수시간을 조정하여 압밀비배수 삼축압축시헙을 할 수 있는 방법을 이 논문에서 제안하였다. 이 방법으로 시험하면 하나의 공시체로 여러 단계의 시험을 하여 강도정수를 구할 수 있음은 물론 시험시간이 종전의 다단계시험에 비해 현저히 절약된다. 이 시험에 대한 적합성을 증명하기 위하여 불교란 시료와 재성형시료에 대해 표준압축시험과 재래의 다단계시험을 수행하고 그 결과를 비교하였다. 여기서 제안하는 시험방법으로 결정된 강도정수는 다른 시험방법으로 얻은 강도정수와 잘 일치하였으며, 이 방법이 대단히 효과적이고 실용적이라는 것을 입증하였다.

  • PDF