• 제목/요약/키워드: Standard Measuring Technology

검색결과 389건 처리시간 0.029초

동적인 온도 보정 방법에 의한 전기 전도도의 측정 (Measurement of electrical conductivity by a dynamic temperature compensation method)

  • 차용대;윤길원
    • 센서학회지
    • /
    • 제17권3호
    • /
    • pp.223-228
    • /
    • 2008
  • A more accurate method of measuring the electrical conductivity (L) of solutions was developed by applying dynamic temperature compensation for measurement of L. Temperature changes of a sample were induced by a heater probe and the changes in L per unit temperature were measured. An equation for L with respect to temperature change was developed and L at the standard temperature ($25^{\circ}C$) was computed. Based on our proposed method, it is possible to have temperature compensation without having the temperature coefficients in advance.

머시닝 센터에서 하중이 위치결정정밀도에 미치는 영향 (The effect on the position precision by load in M.C.)

  • 이승수
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 1998년도 춘계학술대회 논문집
    • /
    • pp.143-147
    • /
    • 1998
  • As the accuracy of manufactured goods needed high-accuracy processing has made the efficiency of NC and measurment technology develop, the innovation of machine tools has influence the development of the semi-conductor and optical technology. We can mention that a traction role of the acceleration for the development like that depends on the development of the measurement technics - Stylus instrument method, STM, SEM, Laser interferometer method - which are used for measuring the movement accuracy of machine tools. The movement error factors in movement accuracy are expressed as yaw, roll, and pitch etc. Machining center has 21 movement error factors including of 3 axies joint errors because that has 3 axies and has been measured as the standard of the unloaded condition until now inspite of getting static, dynamic, and servo-gain errors in the case of expending the error range. Therefore, this study tries to measure position accuracy according to loading on the X-Y table of the machining center.

  • PDF

The Application of Machine Vision to IC Surface Inspection

  • Chung, Yi-Chan;Tsai, Chih-Hung;Lin, Yu-Tang
    • International Journal of Quality Innovation
    • /
    • 제4권2호
    • /
    • pp.50-64
    • /
    • 2003
  • During IC inspection, which includes the two parts of Mark and Lead, the deviation of IC on the tape occurring in high speed movements usually generates light reflection effect, which in turn causes errors in IC recognition as measured by machine vision system. This research filters the light reflection effect by developing standard components, identifies the correct position of IC Lead, hence fixes the measurement errors or non-measurability caused by light reflection, avoids the resulting discontinued operation of measuring system, and improves the productivity.

범용 깊이 카메라를 이용한 인체 외형 비대칭 측정의 반복성 평가 (Repeatability Test for the Asymmetry Measurement of Human Appearance using General-purpose Depth Cameras)

  • 장준수
    • 동의생리병리학회지
    • /
    • 제30권3호
    • /
    • pp.184-189
    • /
    • 2016
  • Human appearance analysis is an important part of both eastern and western medicine fields, such as Sasang constitutional medicine, rehabilitation medicine, dental medicine, and etc. By the rapid growing of depth camera technology, 3D measuring becomes popular in many applications including medical area. In this study, the possibility of using depth cameras in asymmetry analysis of human appearance is examined. We introduce the development of 3D measurement system using 2 Microsoft Kinect depth cameras and fully automated asymmetry analysis algorithms based on computer vision technology. We compare the proposed automated method to the manual method, which is usually used in asymmetry analysis. As a measure of repeatability, standard deviations of asymmetry indices are examined by 10 times repeated experiments. Experimental results show that the standard deviation of the automated method (1.00mm for face, 1.22mm for body) is better than that of the manual method (2.06mm for face, 3.44mm for body) for the same 3D measurement. We conclude that the automated method using depth cameras can be successfully applicable to practical asymmetry analysis and contribute to reliable human appearance analysis.

희석 파라미터법에 의한 철광석 중 철과 티탄의 X-선 형광분석 (X-Ray Fluorescence Analysis of Iron and Titanium in Iron Ores by Dilution Parameter Method)

  • 김영상;이종욱
    • 대한화학회지
    • /
    • 제25권3호
    • /
    • pp.183-189
    • /
    • 1981
  • 철광석 중에서 주성분 원소들인 철과 티탄올 희석 파라미터법(dilution parameter method)을 이용한 X-선 형광분석법으로 분석하였다. 조성이 비슷한 표준시료와 분석시료 각각에 적당한 희석제($ZrO_2$)를 가하여 적당한 비율 (1:1, 1:2등)로 희석시켜서 원하는 원소의 형광 X-선 세기를 측정하여 다음 식으로 희석 파라미터를 구한다.$Pa=\frac{\frac{I_{as}}{(I_{as})_d}}{D-1}{^{-1}}$이들 파라미터를 이용하여 표준시료와 분석시료의 matrix effect 차이를 보정하여 표준검량선 없이 정량 분석하였다.$W_a=W_a^*{\cdot}{\frac{I_as}{I_{as}^*}{\cdot}\frac{P_a^*}{P_a}$여기서, *는 표준시료를 표시한다. 분석결과는 습식법으로 정량한 값들과 잘 일치하고 재현성도 좋음을 보여주었다.

  • PDF

제로에너지빌딩의 기술 패키지 구성을 위한 성능 기준 및 성능 측정 방법에 관한 연구 (A Study on the Performance Measuring Methods and Standard for the Technical Package in Zero Energy Building)

  • 성욱주;임민엽;김석현;조수
    • 한국건축친환경설비학회 논문집
    • /
    • 제12권6호
    • /
    • pp.543-556
    • /
    • 2018
  • Zero energy building was attended for energy consumption minimization by the energy saving technology about building heating and cooling energy consumption and the renewable energy production facility. So the government has supported the zero energy building supply for decreasing green gas emissions. The study about inventory of zero energy building has many proceeding. That inventory need the information of material and equipment. So information of material and equipment about zero energy building must be included for the zero energy building realization. Actually the database of zero energy building inventory construction through the inventory established studies has difficult because the database need many information. In this study, author proposed the test methods and performance reference for upload at inventory. It was constructed to material - module - package. Also the author analyzed the construction of the technical package for zero energy building. The author separated performance category to the energy performance for energy analysis and other performance for confirmed the durability, stability and etc. This performance category proposed the table. The test methods of material and equipment in the passive package and active package proposed to the international standard and korea standard basically korea standard. Also the performance reference was proposed to korea legal standard and various standard by this study results. And the authors proposed the table of performance value, test methods, performance reference. By result of this study, the test methods and performance reference will be used the basic data for inventory of zero energy building.

A study on Measurement and Improvement of Indoor Air Quality in Dental Clinic

  • Choi, Mi-Suk;Ji, Dong-Ha
    • 한국컴퓨터정보학회논문지
    • /
    • 제23권11호
    • /
    • pp.143-149
    • /
    • 2018
  • The purpose of this study is to propose a management method to maintain the pleasant indoor air quality of the dental clinic by measuring and analyzing the indoor air quality of the dental clinic. The measurement was conducted in two rooms, a lobby where many residents stay in the reception room for waiting for medical treatment, and a VIP room where treatment activities are mainly performed. Measurement items are Temperature, Humidity, $CO_2$, CO, $NO_2$, $CH_2O$, VOC, $PM_{10}$ and measurement were taken on April 27, 2018. As a result of analyzing the temperature and humidity of the dental clinic, it was analyzed that the average indoor temperature was maintained at $25^{\circ}C$ and the humidity was kept at around 50%, maintaining proper indoor temperature and humidity environment. $CO_2$ was 855ppm in the VIP Room, which satisfied the maintenance standard. In the case of the lobby, it was analyzed to be 1,160ppm, which exceeded the maintenance standard and it is judged that the carbon dioxide generated by the respiration of the people staying in the lobby is the main reason. The mean concentration of formaldehyde in the VIP room was analyzed as $436{\mu}g/m^3$, exceeding the maintenance standard, and $2,100{\mu}g/m^3$ for the VOC exceeded the recommended standard. It was analyzed that the concentration was relatively higher due to the use of disinfectant and other drugs. The mean concentration of PM-10 in the lobby was analyzed as $65{\mu}g/m^3$ and it was analyzed that it satisfied the maintenance standard. To maintain a pleasant indoor air quality in a dental clinic it is necessary to minimize the effects of formaldehyde, VOC, $CO_2$ in the VIP rooms and lobby. For this purpose, the entire ventilation system and air purification system of the dental clinic should be installed. In case of the VIP room, local exhaust ventilation should be installed and workers should wear personal protective equipment.

GPS 측위기술의 포 방열 적용 연구 (Study on Applying GPS Positioning Technique to Cannon Laying)

  • 조정호;박종욱;박필호;임형철;최만수;권영철
    • 한국군사과학기술학회지
    • /
    • 제4권2호
    • /
    • pp.52-59
    • /
    • 2001
  • In this paper, we have proposed a capability of applying Global Positioning System(GPS) to cannon laying. High precision GPS positioning can be used for measuring precise positions and angles. Therefore, we have tested on applying GPS positioning technique to measurement of positions and angles, which related to cannon laying. First of all, we have determined a GPS reference position using various positioning methods. Then we have carried out several tests that are process of taking corner angles between neighboring two vectors. Each vector can be calculated by post/real time positioning of two GPS antennas placed on the both ends of the howitzer. The Comer Angles from Post processing(CAP) are compared with the other Corner Angles from Real time positioning(CAR). As the results, we have an agreement between CAP and CAR within 0.25 mil average, 0.29 mil standard deviation. Finally, we have discussed about the capabilities and problems in artillery arrangement using GPS.

  • PDF

Improvement of reliability of an ISFET pH-meter by employing multiple sensors

  • 장기석;조병욱;김창수;최상복;손병기
    • 센서학회지
    • /
    • 제6권2호
    • /
    • pp.131-136
    • /
    • 1997
  • The ISFET(ion sensitive field effect transistor), a semiconductor ion sensor, has many advantages over conventional ion sensors. Various single-sensor type ISFET pH-meters have been developed. However, they could not be applied in fields because their performances are directly affected by the sensor condition. With only one sensor, the system could be easily damaged from environmental factors, and reliability of it is decreased. Therefore, a 4-channel PH-meter system is proposed to improve the reliability of ISFET pH-meter. It has 4 ISFETS as ion sensor, and a software which contains a new calibration and measurement algorithm appropriate to the system. The reliability of the system was proved by measuring hydrogen ion concentration in the pH standard solutions and buffer solutions.

  • PDF

후판 압연의 온라인 온도예측 모델 개발 (Development of On-line Temperature Prediction Model for Plate Rolling)

  • 서인식;이창선;조세돈;주웅용
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1999년도 제3회 압연심포지엄 논문집 압연기술의 미래개척 (Exploitation of Future Rolling Technologies)
    • /
    • pp.283-292
    • /
    • 1999
  • Temperature prediction model was developed for on-line application to plate rolling mills of POSCO. The adequate boundary conditions of heat transfer coefficients were obtained by comparing the predicted temperature with the measured temperatures taken by measuring system in plate rolling mill of POSCO. In obtaining the boundary condition which minimize the mean and standard deviation of the difference between prediction and measurement, orthogonal array for experimental design was used to reduce the calculation time of large data set. To predict the temperature drop at four edge of plate in one dimensional model, the energy change by heat transfer though directions perpendicular to thickness direction was treated like that by deformation. And the heat transfer through four edge directions was inferred from that through thickness direction with two coefficients of depth and severity of temperature drop at the edge. The boundary condition for the depth and severity of temperature drop were also determined using the measured temperature.

  • PDF