• 제목/요약/키워드: Standard Measuring Technology

검색결과 389건 처리시간 0.026초

원격탐사 기술의 산림탄소 축적량 추정적용에 있어서의 도전 (Challenges in Application of Remote Sensing Techniques for Estimating Forest Carbon Stock)

  • 박주원
    • Current Research on Agriculture and Life Sciences
    • /
    • 제31권2호
    • /
    • pp.113-123
    • /
    • 2013
  • The carbon-offset mechanism based on forest management has been recognized as a meaningful tool to sequestrate carbons already existing in the atmosphere. Thus, with an emphasis on the forest-originated carbon-offset mechanism, the accurate measurement of the carbon stock in forests has become important, as carbon credits should be issued proportionally with forest carbon stocks. Various remote sensing techniques have already been developed for measuring forest carbon stocks. Yet, despite the efficiency of remote sensing techniques, the final accuracy of their carbon stock estimations is disputable. Therefore, minimizing the uncertainty embedded in the application of remote sensing techniques is important to prevent questions over the carbon stock evaluation for issuing carbon credits. Accordingly, this study reviews the overall procedures of carbon stock evaluation-related remote sensing techniques and identifies the problematic technical issues when measuring the carbon stock. The procedures are sub-divided into four stages: the characteristics of the remote sensing sensor, data preparation, data analysis, and evaluation. Depending on the choice of technique, there are many disputable issues in each stage, resulting in quite different results for the final carbon stock evaluation. Thus, the establishment of detailed standards for each stageis urgently needed. From a policy-making perspective, the top priority should be given to establishinga standard sampling technique and enhancing the statistical analysis tools.

  • PDF

커프 압력 조절에 따른 혈류량 변화 평가를 위한 임피던스법의 구현 (Implementation of Impedance Method to Estimate Blood Flow Variation with Cuff Pressure Change)

  • 정도운;배진우;손정만;예수영;최병철;남기곤;김철한;전계록
    • 센서학회지
    • /
    • 제13권6호
    • /
    • pp.462-472
    • /
    • 2004
  • In this study, we measured the blood flow on arm by non-invasive method and implemented a system to measure variation of the blood flow by estimating bio-electrical impedance and arterial pressure according to cuff pressure. The implemented system measured impedance variation according to pressure variation applied by artificial cuff pressure on the measuring position. The system consisted of pressure measuring part and impedance measuring part using 4-electrode method. Pressure measuring part was composed of semiconductor pressure sensor and electronic circuit for signal processing of sensor output signal. In addition, impedance measuring part was composed of constant current source circuit and lock-in amplifier for detecting impedance signal. We conducted experiments of impedance measuring part using standard resistance for performance evaluation of the implemented system. In addition we experimented to estimate variation of the blood flow by measuring impedances of the experimental group. We estimated ratio of the blood flow resistance using mean arterial pressure and variation of the blood flow. As a result the ratio of the blood flow resistance and variation of blood flow were in an inverse relationship with each other and the correlation coefficient was -0.96776.

변조전달함수 방법에서 엣지 장치 설정에 대한 각도 최적화 평가 (Evaluation of Angle Optimization on Edge Test Device Setting in Modulation Transfer Function)

  • 민정환;정회원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제43권1호
    • /
    • pp.15-21
    • /
    • 2020
  • This study was purpose to evaluation of Modulation Transfer Function in Measurements by using the International electrotechnical commission standard(IEC 62220-1) which were edge device each angle by using edge method. In this study was Aero(Konica, Japan) image receptor which is a indirect Flat panel detector(FPD) was used. The size of matrix 1994 × 2430 (14"× 17" inch) which performed 12 bit processing and pixel pitch is 175 ㎛. The results of shown as MTF measurements at IEC standard. The amount of data seemed reasonable and at an MTF value of 0.1 the spatial frequencies were 2.56 cycles/mm at an angle of 2.4°. MTF value of 0.5 the spatial frequencies were 1.32 cycles/mm at an angle of 2.4°. This study were to evaluate MTF by setting each angle 2.0°~2.8° degrees the most effective optimal edge angle and to suggest the quantitative methods of measuring by using IEC.

Data Envelopment Analysis on Measuring the Performance of Vietnamese Joint-Stock Commercial Banks

  • NGO, Duc Tien;PHUNG, Thu Ha;DINH, Tuan Minh;NGUYEN, Thuy Lien
    • The Journal of Asian Finance, Economics and Business
    • /
    • 제9권7호
    • /
    • pp.53-62
    • /
    • 2022
  • Commercial banks have a significant impact on the economy of Vietnam because they provide the majority of transactional capital. Therefore, the operational efficiency of commercial banks is a viral topic for the study of the Vietnamese banking system. The research aims to examine the efficiency and inefficiency of joint-stock commercial banks in Vietnam from 2016 to 2020 and then classify them into the efficient group and inefficient group. The study employs the time series data of 29 joint-stock commercial banks during the period 2016-2020. Based on the data collected from the annual audited financial statements of 29 Vietnamese joint-stock commercial banks, the authors select input and output variables for the standard DEA models and anti-efficient DEA models. This research uses two stages, first, by applying the standard DEA model, we investigate the efficient banks; second, by employing the anti-efficient DEA model, we find out the inefficient banks. The results reveal that the average efficiency score of 29 joint-stock commercial banks tends to increase in the period 2016-2018 and decrease gradually in the period 2019-2020. The findings of this study suggest that several small and medium-sized banks in the Vietnamese banking sector have both promising and risky performances and the efficiency of state-owned commercial banks has also improved significantly during the study period.

Functional Integration of Serial Dilution and Capillary Electrophoresis on a PDMS Microchip

  • Chang, Jun-Keun;Heo, Yun-Seok;Hyunwoo Bang;Keunchang Cho;Seok Chung;Chanil Chung;Han, Dong-Chul
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제8권4호
    • /
    • pp.233-239
    • /
    • 2003
  • For the quantitative analysis of an unknown sample a calibration curve should be obtained, as analytical instruments give relative, rather than absolute measurements. Therefore, researchers should make standard samples with various known concentrations, measure each standard and the unknown sample, and then determine the concentration of the unknown by comparing the measured value to those of the standards. These procedures are tedious and time-consuming. Therefore, we developed a polymer based microfluidic device from polydimethylsiloxane, which integrates serial dilution and capillary electrophoresis functions in a single device. The integrated microchip can provide a one-step analytical tool, and thus replace the complex experimental procedures. Two plastic syringes, one containing a buffer solution and the other a standard solution, were connected to two inlet holes on a microchip, and pushed by a hydrodynamic force. The standard sample is serially diluted to various concentrations through the microfluidic networks. The diluted samples are sequentially introduced through microchannels by electro-osmotic force, and their laser-induced fluorescence signals measured by capillary electrophoresis. We demonstrate the integrated microchip performance by measuring the fluorescence signals of fluorescein at various concentrations. The calibration curve obtained from the electropherograms showed the expected linearity.

대학원생 표준 학술능력 진단평가 도입 제안: 호즈 시드니 대학교 MASUS 사례를 중심으로 (Suggestion for Measuring the Academic Skills of Graduate Students A Standard Diagnostic Assessment: Focusing on the MASUS Procedure of University of Sydney)

  • 손소라;안미리;차현진
    • 한국컴퓨터교육학회 학술대회
    • /
    • 한국컴퓨터교육학회 2018년도 동계학술대회
    • /
    • pp.115-118
    • /
    • 2018
  • 본 연구는 대학원생의 연구 수행을 위한 학술적 역량 진단 및 평가를 기반으로 하여 성취 과정을 지원하는 대학원생의 표준 학술능력 진단평가 도입을 제안하고자함을 목적으로 하였다. 이를 위하여 호주 시드니 대학교의 대학생 학업능력 진단평가 모델인 MASUS(Measuring the Academic Skills of University Students A Diagnostic Assessment)를 연구대상으로 선정하고 질적연구 방법 중 도구적(instrumental) 사례연구를 선택하였다. 이에 따라, 자료 수집 단계에서 시드니대학교 학습지원센터 관계자와의 반구조화된 면대면 인터뷰 및 문헌자료를 정보원으로 하여 자료를 분석함으로써 MASUS의 특징과 시사점을 도출하였다. 이를 기반으로 학문적 소양으로서의 글쓰기 능력의 의미와 중요성을 고찰하고, 이를 통해 대학원생 학술 역량 진단평가 도입의 당위성을 부여하였다. 본 연구를 통해 향후 모든 대학원에서 범용적으로 적용할 수 있는 객관적이고 신뢰도 높은 표준 진단평가 모델을 개발하여 긍정적인 진단문화를 형성할 수 있기를 바라는 바이다.

  • PDF

Measurements of Blood Viscosity Using a Pressure-Scanning Slit Viscometer

  • Sehyun Shin;Lee, Sung-Woo;Ku, Yun-Hee
    • Journal of Mechanical Science and Technology
    • /
    • 제18권6호
    • /
    • pp.1036-1041
    • /
    • 2004
  • A newly designed pressure-scanning slit viscometer is developed to combine an optical device without refraction while measuring blood viscosity over a range of shear rates. The capillary tube in a previously designed capillary viscometer was replaced with a transparent slit, which is affordable to mount optical measurement of flowing blood cells. Using a pressure transducer, we measured the change of pressure in a collecting chamber with respect to the time, p(t), from which the viscosity and shear rate were mathematically calculated. For water, standard oil and whole blood, excellent agreement was found between the results from the pressure-scanning slit viscometer and those from a commercially available rotating viscometer. This new viscometer overcomes the drawbacks of the previously designed capillary viscometer in the measuring whole blood viscosity. First, the pressure-scanning slit viscometer can combine an optical instrument such as a microscope. Second, this design is low cost and simple (i.e., ease of operation, no moving parts, and disposable).

CCD/LSB 방식의 형상측정시스템의 정밀도 향상 방법 (Precision enhancement for a CCD/LSB type shape measuring system)

  • 유주상;정규원
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 춘계학술대회 논문집(한국공작기계학회)
    • /
    • pp.137-142
    • /
    • 2001
  • Since recent production system becomes that of the small quantity, large volume with high quality production, accurate and high speed inspection system is required. In such situation, noncontact 3D measurement system which utilized CCD cameras is useful technique in terms of system cost, speed of data acquisition, measuring accuracy and application. However, it has low accuracy compared with contact 3D measurement system because of the camera distortion, non uniformity of laser distribution and so on. For those reasons, in this paper precision enhancement method is studied considering radial camera distortion, and laser distribution. A distortion correction method is applied even to the standard lens. The laser slit beam trajectory is determined by 3 method: based of the Gaussian function signal approximation, the median method, the center of gravity method and the peak point of the Gaussian function method.

  • PDF

관측성을 이용한 3축 SCARA Robot의 오차분석을 위한 Monte-Carlo simulation 및 측정 (Monte-Carlo Simulation and measuring for Error Analysis of 3-axis SCARA Robot using Observability)

  • 주지훈;정원지;김정현
    • 한국공작기계학회논문집
    • /
    • 제17권4호
    • /
    • pp.8-14
    • /
    • 2008
  • This paper aims at finding out dominant robot configurations with maximal position errors, which can be attributed to the parameter errors, by using Monte-Carlo simulation for error analysis of a 3-axis SCARA(Selective Compliance Assembly Robot Arm) type robot. In particular, the Monte-Carlo simulation is used for virtually measuring on the position errors, instead of physical measurement. In order to measure the observability of the model parameters with respect to a set of robot configurations, we propose the observability index which is defined as the product of singular values for error propagation matrices. Thus the index can be used for discriminating dominant robot configurations from a set of simulated ones in conjunction with standard deviation of positional errors, This paper analyzed error by robot positional error.

문서입력 작업 시 컴퓨터 키보드 유형이 손목관절의 운동학적 특성에 미치는 영향 (The Effect of Standard Keyboard and Fixed-Split Keyboard on Wrist Posture During Word Processing)

  • 권혁철;정동훈;공진용
    • 한국전문물리치료학회지
    • /
    • 제11권1호
    • /
    • pp.35-43
    • /
    • 2004
  • There were two purposes of this study. The first was to research the effects of standard and fixed-split keyboards on wrist posture and movements during word processing. The second was to select optimal computer input devices in order to prevent cummulative trauma disorder in the wrist region. The group of subjects consisted of thirteen healthy men and women who all agreed to participate in this study. Kinematic data was measured from both wrist flexion and extension, and wrist radial and ulnar deviation during a 20 minute period of word processing work. The measuring tool was an electrical goniometer, and was produced by Biometrics Cooperation. The results were as follows: 1. The wrist flexion and extension at resting starting position were not significantly different (p>.05), however the angle of radial and ulnar deviation were significantly different in standard and split keyboard use during word processing (p<.05). 2. In the initial 10 minutes, the dynamic angle of wrist flexion and extension were not significantly different (p>.05), however the dynamic angle of radial and ulnar deviation was significantly different in standard and split keyboard use during word processing (p<.05). These results suggest that the split keyboard is more optimal than the standard keyboard, because it prevented excessive ulnar deviation during word processing.

  • PDF