• Title/Summary/Keyword: Standard Measuring Technology

Search Result 389, Processing Time 0.034 seconds

A Study on the Measurement System Design for Measuring Properties of AC Magnetic Field Sensor (교류 자기센서 특성 시험장치 설계에 관한 연구)

  • Chung, Hyun-Ju;Yang, Chang-Seob;Jung, Woo-Jin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.18 no.3
    • /
    • pp.244-252
    • /
    • 2015
  • This paper describes design and construction results of the measurement system developed on the purpose of measuring properties of AC magnetic field sensors used in the weapon system. The system for measuring the properties of AC magnetic field sensors consist of 3-axis helmholtz coil, signal generator, signal amplifier, sensor data acquisition unit and AC magnetic field sensor property measurement & analysis equipment including the operating software. By using this system, we can measure various properties of AC magnetic field sensor such as sensitivity, linearity and dynamic response in the frequency from 1 Hz to 10 kHz. Finally we also verified its performance by measuring the property of a MAG 639, standard magnetic field sensor of bartington instruments, with the developed measurement system.

Development of a Delivery Workload Management System for Measuring and Balancing Standard Workload of Mailmen (집배부하량 산정 및 평준화를 위한 집배부하 관리시스템 개발)

  • Cha, Chun-Nam;Sun, Ji-Ung;Park, Moon-Sung
    • IE interfaces
    • /
    • v.24 no.4
    • /
    • pp.435-446
    • /
    • 2011
  • Performance measures play a critical role in formulating mail delivery strategies and evaluating actual results. Nevertheless, the existing method and corresponding system to determine the standard workloads of mailmen is developed without careful consideration of real delivery environments and various requirements of mailmen. Hence, the current system is insufficient for optimal management of workloads and shows substantial gaps when compared to the results of actual work-site. This study considers how to improve the current workload management system of mailmen. We first performed the as-is analysis of the mail delivery service and then developed a prototype of advanced delivery workload management system. The to-be system consists of five subsystems which can be grouped into three categories; master data management, workloads management, performance analysis. Our results can be a valuable guide for the development of real system for measuring and balancing the workloads of mailmen.

An Angle-Binder Drawbead Simulator for Measuring Drawbead Forces on Inclined Binder Surface (경사진 바인더면의 드로우비드력을 측정하기 위한 모의실험장치)

  • Yang, W.H.;Choi, K.Y.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.05a
    • /
    • pp.180-184
    • /
    • 2009
  • A novel set of experimental test tooling for measuring pulling and holding forces for drawbeads on binders inclined at a wide range of angles is introduced. A mechanical design featuring a single load cell, a male-female draw bead set, translation and rotation degrees of freedom, and a screw-driven clamping system has been incorporated into a standard tensile test machine. On a real time basis, restraining and holding force data with respect to draw-in displacement may be directly downloaded into a PC for data processing. The proposed experimental system represents a significant breakthrough in drawbead simulation technology due to its relatively low cost, clever design, and versatility. The system is shown to yield excellent experimental data suitable for verifying theory and numerical model predictions.

  • PDF

Method for Rapid and Accurate Measurement of Chitosan Viscosity

  • No, Hong -Kyoon;Samuel P. Meyers
    • Preventive Nutrition and Food Science
    • /
    • v.4 no.2
    • /
    • pp.85-87
    • /
    • 1999
  • A simple and rapid method to estimate the viscosity of chitosan using laboratory pipettes was developed. The voscosities of nine different chitosan samples, prepared ini 1 % acetic acid at a 1% concentration , were measured with a standard viscometer. Prior to measurement of flow time of 1% chitosan solution with a pipette, twelve pipettes were assorted into three groups with flow times of 4, 5 and 6 sec after measuring passage of 9 ml of 1% acetic acid througth a 10 ml pipette. With each group of pipettes. flow time of 1% chitosan solution was determined by measuring the delivery time of 5 ml of the 10ml solution through a 10 ml pipette. Results of regression analyses revealed high linear relationship(R2=0.9812, 0.9663, and 0.9754) between viscosities calculated with a viscometer and flow times measured with 4, 5 or 6 sec group pipettes. The viscosity of chitosan could be readily and accurately estimated from these linear regression equation by measuring flow times based on pipette delivery.

  • PDF

Estimating blood pressure using the pulse transit time of the two measuring from pressure pulse and PPG

  • Kim, Gi-Ryon;Ye, Soo-Young;Kim, Jae-Hyung;Jeon, Gye-Rok
    • Journal of Sensor Science and Technology
    • /
    • v.17 no.2
    • /
    • pp.87-94
    • /
    • 2008
  • Blood pressure (BP), one of the most important vital signs, is used to identify an emergency state and reflects the blood flow characteristics of the cardiovascular system. The conventional noninvasive method of measuring BP is inconvenient because patients must wear a cuff on their arm and the measurement process takes time. This paper proposes an algorithm for estimating the BP using the pulse transit time (PTT) of the photoplethysmography (PPG) and pressure pulse from finger at the same time as a more convenient way to measure the BP. After recording the electrocardiogram (ECG), measuring the pressure pulse, and performing PPG, we calculated the PTT from the acquired signals. Then, we used a multiple regression analysis to measure the systolic and diastolic BP indirectly. Comparing the BP measured indirectly using the proposed algorithm and the real BP measured with a sphygmomanometer, the systolic pressure had a mean error of ${\pm}3.240$ mmHg and a standard deviation of 2.530 mmHg, while the diastolic pressure had a satisfactory result, i.e., a mean error of ${\pm}1.807$ mmHg and a standard deviation of 1.396 mmHg. These results are more superior than existing method estimating blood pressure using the one PTT and satisfy the ANSI/AAMI regulations for certifying a sphygmomanometer i.e., the measurement error should be within a mean error of ${\pm}5$ mmHg and a standard deviation of 8 mmHg. These results suggest the possibility of applying our method to a portable, long-term BP monitoring system.

Development of the testing method for vinyl chloride monomer (VCM) in polyvinyl chloride(PVC) samples (PVC 제품에서의 염화비닐 단량체 정량분석 방법에 관한 연구)

  • Kweon, Deok-Jun;Choi, Ki-In;Eom, Hui-Jeong;Lee, Jae-In;Choi, Zel-Ho
    • Analytical Science and Technology
    • /
    • v.25 no.6
    • /
    • pp.395-401
    • /
    • 2012
  • This study presents a method for the quantitative analysis of residual vinyl chloride monomer (VCM) in PVC products. In elution solvent, the extraction efficiency was similar by ethanol, THF, and acetone, but using n-hexane, it indicated relatively low extraction efficiency. Measuring VCM in the pulverized PVC samples, it showed reasonable results in both the direct injection method and headspace method with GC/MS. Regarding analysis of VCM in the intermediate sponge samples, five laboratories showed good results, and from the results, it was considered that VCM quantitative method in this study was reliable.

Improvement Study on Measuring Method of X-Ray Grid Characteristics (산란선 제거용 X선격자의 실험방법의 새로운 시도)

  • Huh, Joon;Kim, Chung-Min
    • Journal of radiological science and technology
    • /
    • v.10 no.1
    • /
    • pp.69-74
    • /
    • 1987
  • Authors attempted grid performance test by film methods than can be used easily on the hospital. And we investigated the utility of it comparing with the values measured by fluorescence meter recommended to be used ordinarily. The result was that, the characteristic values obtained by film methods was almost the same as those obtained by fluorescence meter methods. And besides plain film methods that can be applied simply showed small standard deviation. Therefore, we considered that it can be adopted easily on the labor that was not ready for special measuring apparatus like fluorescence meter.

  • PDF

Design of Channel Impedance Measurement Equipment for Indoor Power Line Communications (옥내 전력선 통신 채널 임피던스 측정 장치 설계)

  • Heo, Yun-Seok
    • The Journal of Information Technology
    • /
    • v.8 no.3
    • /
    • pp.25-33
    • /
    • 2005
  • This paper describe a method for measuring line impedance as a function of frequency for an energized powerline in normal operation. A small sinusoidal signal of a powerline communication utility frequency 30khz$\sim$1Mhz band is continuously injected into the line, and a implemented impedance analyzer calculates the indoor powerline channel impedance from the measured magnitude and phase of resulting voltage and current. The impedance measurement is executed over a range of frequencies to produce a wideband impedance versus frequency characteristic. Implemented impedance analyzer can analysis powerline communication environments measuring line impedance due to load caused in indoor. And measured analysis information through the database can use to evaluate performance of modem and to decide test environment standard.

  • PDF

Setup of standard PD calibrator and its uncertainties

  • Kim, Kwang-Hwa;Yi, Sang-Hwa;Lee, Heun-Jin;Kang, Dong-Sik
    • Journal of Electrical Engineering and Technology
    • /
    • v.6 no.5
    • /
    • pp.677-683
    • /
    • 2011
  • The present paper describes the setup of standard partial discharge calibrator for measuring partial discharge and estimating uncertainties. The standard PD calibrator was designed and set up, consisting of a digital pulse generator, capacitor modules, and a digital oscilloscope controlled by software developed in the laboratory. Using this software, averages of charges and rising times and their standard deviations in the measured pulses can also be calculated. The standard PD calibrator generates five types of pulses: single, double, random, oscillating, and long-rising. The coefficient sensitivities to estimate the uncertainties of pulses were extracted in the model circuit of the standard PD calibrator. The uncertainties of charges and rising times in pulses of the standard PD calibrator were estimated with single pulses. These values were 0.3%-1.4% in charges and 1.9%-7.0% in rising time; however, these values are lower than the limit values in IEC 60270.

Effects of the Sheath on Determination of the Plasma Density of Microwave Probe

  • Kim, Dae-Woong;You, Shin-Jae;Na, Byung-Keun;You, Kwang-Ho;Kim, Jung-Hyung;Chang, Hong-Young
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2012.02a
    • /
    • pp.181-181
    • /
    • 2012
  • The microwave probe for measuring plasma density is widely used for its advantages: First, it is not affected by the reactive gas. Second, it can measure local plasma parameters such as plasma density, plasma potential and plasma temperature. Third, it is simple and robust. A cut-off probe is the one of the most promising microwave probe. Recently, Kim et al. reveals the physics of the cut-off probe but the effect of the sheath on the determination of the plasma density is not explained. In this presentation, for taking account of sheath effects on determination of plasma density from the cut-off peak, a simplified circuit modeling and an E/M simulation are conducted. The results show that occupation ratio of sheath volume between two tips of the cut-off probe and subsequence pressure condition mainly change position of the cut-off peak with respect to plasma frequency. Magnitude of relative voltage taken on the impedance of sheath and the impedance of bulk plasma can explain this effect. Furthermore, effects of gap size, tip radius, and tip length ware revealed based on above analysis.

  • PDF