• Title/Summary/Keyword: Standard Measuring Technology

Search Result 390, Processing Time 0.023 seconds

Estimation of Joint Roughness Coefficient(JRC) using Modified Divider Method (수정 분할자법을 이용한 절리 거칠기 계수(JRC)의 정량화)

  • Jang Hyun-Shic;Jang Bo-An;Kim Yul
    • The Journal of Engineering Geology
    • /
    • v.15 no.3
    • /
    • pp.269-280
    • /
    • 2005
  • We assigned points on surface of standard roughness profile by 0.1mm along the length and measured coordinates of points. Then, the lengths of profile were measured with different scales using modified divider method. The fractal dimensions and intercepts of slopes were determined by plotting the length vs scale in log-log scale. The fractal dimensions as well as intercepts of slopes show well correlation with joint roughness coefficients(JRC). However, multiplication of the kactal dimension by intercept show better correlation with IRC and we derived a new equation to estimate JRC from fractal dimension and intercept. The crossover length in which we can determine the correct fractal dimension was between 0.3-3.2mm. We measured joint roughness of 26 natural joints and calculated JRC using the equation suggested by Tse and Cruden(1979) and new equation derived by us. IRC values calculated by both equations are almost the same, indicating new equation is effective in measuring IRC.

Application of Fourier Transform Near-Infrared Spectroscopy for Prediction Model Development of Total Dietary Fiber Content in Milled Rice (백미의 총 식이섬유함량 예측 모델 개발을 위한 퓨리에변환 근적외선분광계의 적용)

  • Lee Jin-Cheol;Yoon Yeon-Hee;Eun Jong-Bang
    • Food Science and Preservation
    • /
    • v.12 no.6
    • /
    • pp.608-612
    • /
    • 2005
  • Fourier transform-near infrared (FT-NIR) spectroscopy is a simple, rapid, non-destructive technique which can be used to make quantitative analysis of chemical composition in grain. An interest in total dietary fiber (TDF) of grain such as rice has been increased due to its beneficial effects for health. Since measuring methods for TDF content were highly depending on experimental technique and time consumptions, the application of FT-NIR spectroscopy to determine TDF content in milled rice. Results of enzymatic-gravimetric method were $1.17-1.92\%$ Partial least square (PLS) regression on raw NIR spectra to predict TDF content was developed Accuracy of prediction model for TDF content was certified for regression coefficient (r), standard error of estimation (SEE) and standard error of prediction (SEP). The r, SEE and SEP were 0.9705, 0.0464, and 0.0604, respectively. The results indicated that FT-NIR techniques could be very useful in the food industry and rice processing complex for determination of TDF in milled rice on real time analysis.

Correlation between Crack Width and Water Flow of Cracked Mortar Specimens Measured by Constant Water Head Permeability Test (정수위 투수시험에 의해 측정된 균열 모르타르 시편의 유출수량과 균열폭의 상관관계)

  • Choi, Seul-Woo;Bae, Won-Ho;Lee, Kwang-Myong;Shin, Kyung-Joon
    • Journal of the Korea Concrete Institute
    • /
    • v.29 no.3
    • /
    • pp.267-273
    • /
    • 2017
  • Recently, the researches of self-healing concrete technology are being carried out actively due to the advent of importance for the maintenance of concrete structures. A water permeability test has been widely used for the evaluation of self-healing performance. However, it is difficult to compare tests results since there is no standard test method related to the self-healing. A standard method for measuring the crack width does not exist neither though the self-healing performance is significantly influenced by the initial crack width. In this study, the effect of water head and crack width on water flow was investigated using a constant water head permeability test equipment. The correlation equation between the initial crack width and water flow was suggested through the regression analysis of test data, and the predicted crack widths agree well with the real crack widths measured using microscopy.

A Study on the Quality Control of the Radioimmunoassay Serum $T_3$(triiodothyronine) (혈청(血淸)$T_3$의 방사면역측정시(放射免疫測定時) 정도관리(精度管理)에 관(關)한 검토(檢討))

  • Kyong, Kwang-Hyon;Choi, Young-Sook
    • Journal of radiological science and technology
    • /
    • v.5 no.1
    • /
    • pp.55-62
    • /
    • 1982
  • Measurement of triiodothyronine($T_3$) concentration is useful for the diagnosic and treatment of thyroid gland diseases. Fundermental studies of measurement of $T_3$ concentration by radioimmunoassay were performed and values determined by commercially available kit, Coat-A-Count, Diagnostic Products Corporation. The optimal utilization of the radioimmunoassay in measuring $T_3$ concentrations is dependant not only on high quality performance of the assay, but also on their appropriate application to the clinical situation. These are several aspects that must be considered in every individual case. These include factors such as accurate pippeting in reagent preparation in the assay and through decanting to remove all visible moisture after incubation steps and so forth. In attempt to assess quality control of the radioimmunoassay of serum $T_3$, serum pools with high, medium, low $T_3$ concentrations were assayed for each of 5 samples. The results obtained with this study were as follow: 1. The coefficient of variation(C. V.) for the standard curve ranged between $0.2{\sim}3.5%$. 2. It was necessary that both incubation time and temperature should correctly be maintained all the in the assay performance. 3. The precison with the $T_3$ RIA procedure was good. 4. The measured values of serially diluted serum $T_3$ concentration with Ong/dl standard solution was proportional to the predicted values. However dilution curve of distilled water was not strait. 5. Calculated $T_3$ values of patient serum in normal group was $107.8{\pm}25.90ng/dl$ in male patient and $127.29{\pm}24.08ng/dl$ in female patient.

  • PDF

Study on Measurements in Thyroid Uptake Rate Test (갑상선섭취율검사시(甲狀腺攝取率檢査時) 측정조건(測定條件)에 관(關)한 조사연구(調査硏究))

  • Kyong, Kwang-Hyon;Kim, Hwa-Gon
    • Journal of radiological science and technology
    • /
    • v.4 no.1
    • /
    • pp.55-62
    • /
    • 1981
  • This study was conducted, during the period of 20-30th, July in 1981, to survey measurement methods in thyroid uptake rate test in Seoul city. The results were summarized as follows: 1. For the great part of nuclear medcine department, a mount of radioiodine($^{131}I$) administrated to the patients was $50-100{\mu}Ci$ in thyroid uptake rate test. 2. Distribution of scintillation, counter with crystal size of $1\frac{1}{2}inch$ was 43%, 3inch(22%), 2.5inch(14%) and $2\frac{1}{2}inch$ was 7% in RAI uptake rate test. 3. When RAI uptake rate test was performed, distribution of collimator in use was flat field type collimator(78%) in general and cylindrical type collimator was 22%. 4. High voltage applied to the P-M tube was $900{\sim}1000V$(50%) and most units provided $3{\sim}15%$ of the window range for the $^{131}I$ peak $\gamma-ray$ energy. 5. Distribution on the use of neck phantom for measurements standard solution was 57% and distribution of b filter in use for room background counts and extrathyroidal tissue was 43% and 50%. 6. The distance between the counter and the source was 25cm(58%) in measuring radioactivity of standard solution, thyroid tissue and background radioactivity count. 7. The early uptake measurements(2, 4, 6 hours) are done after administration of the radioiodine dose and also 24-hour and 48-hour uptake measurements are done in routine test.

  • PDF

Liquid chromatography-tandem mass spectrometric analysis of oleracone D and its application to pharmacokinetic study in mice

  • Lim, Dong Yu;Lee, Tae Yeon;Lee, Jaehyeok;Song, Im-Sook;Han, Young Taek;Choi, Min-Koo
    • Analytical Science and Technology
    • /
    • v.34 no.5
    • /
    • pp.193-201
    • /
    • 2021
  • We have demonstrated a sensitive analytical method of measuring oleracone D in mouse plasma using a liquid chromatography-tandem mass spectrometry (LC-MS/MS). Oleracone D and oleracone F (internal standard) in mouse plasma samples were processed using a liquid-liquid extraction method with methyl tertbutyl ether, resulting in high and reproducible extraction recovery (80.19-82.49 %). No interfering peaks around the peak elution time of oleracone D and oleracone F were observed. The standard calibration curves for oleracone D ranged from 0.5 to 100 ng/mL and were linear with r2 of 0.992. The inter- and intra-day accuracy and precision and the stability fell within the acceptance criteria. The pharmacokinetics of oleracone D following intravenous and oral administration of oleracone D at doses of 5 mg/kg and 30 mg/kg, respectively, were investigated. When oleracone D was intravenously injected, it had first-order elimination kinetics with high clearance and volume of distribution values. The absolute oral bioavailability of this compound was calculated as 0.95 %, with multi-exponential kinetics. The low aqueous solubility and a high oral dose of oleracone D may explain the different elimination kinetics of oleracone D between intravenous and oral administration. Collectively, this newly developed sensitive LC-MS/MS method of oleracone D could be successfully utilized for investigating the pharmacokinetic properties of this compound and could be used in future studies for the lead optimization and biopharmaceutic investigation of oleracone D.

A Study of Ethical Sense of Value and Discord of the Clinical Nurse (임상간호사(臨床看護師)의 윤리적(倫理的) 가치관(價値觀)과 윤리적(倫理的) 갈등(葛藤)에 관한 연구(硏究))

  • Jong, Heui-Ja;Moon, Heui-Ja
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.1 no.2
    • /
    • pp.349-371
    • /
    • 1995
  • Professional nurse shall possess the firm nursing idea and ethical nursing philosophy based on the professional knowledge and technology but due to the rapid social situations has changed the value to man thus the nurse's sense of value in the nursing secenes has been confused and changed bringing the new ethical problems and discord due to the ethically difficult problems. This study is aimed to know about the discord between the ruling ethical sense of value and the ethical discord exeriencing in the clinical scenes of the nurse and to help them establish affirmative ethical sense of value and provide them with the materials which can effectively meet the ethical discord. The study research has been conducted by selecting 515 clinical nurses in 8 general hospitals as the subject from Mar. 13, 1995 to Apr. 3. The tool measuring the ethical sense of value disigned by Lee, Young Sook has been used and supplemented and the tool measuring the ethical discord was the question papers about the ethical dillemma of Han, Sung Sook. The collected materials have been analyzed by the statistical methods of arithmetical everage, t-test, ANOVA, Pearson's Correlation Coefficient and etc. The result of the study is as the below ; 1) The average point of the ethical sense of value of the nurse was 3.62(maximum point : 5) which showed that the ethical level was so high and the highest question item in the ethical level of the whole items of the ethical sense of value was "They conduct as directed by the doctor in case the disposition of the doctor looks mistaken"(4.56 point), "They keep the secret of the patients while serving them."(4.56) and the lowest item was "using placobo for the patients is not allowed" : (1.85 point). 2) Statistical variation which showed the significant difference in the relation with the ethical sense of value according to the general characters of the nurse has shown as scholarly years(F=3.47, p=.016), religion(F=1.66, p=.004), interest degree of ethical education(F=4.18, p=.006),attitude to the job of nursing(F=6.76, p=.006), ethical standard(F=3.28, p=.021), and recognition degree on ethical principles(F=4.53, p=.001). 3) The average point of the ethical discord of the nurse was 0.54(The maximum-1 point) point and the ethical discord in the clinical scenes : "the problems arising from the lack of manpower of the nurse"(0.86), "the discord from the uncooperative relation between them and the medical staff and"(0.75) and indifference of the doctor about the report of the nurse(0.73). 4) The variation which showed the significant difference statistically in the ethical discord according to the general characters of the nurse was that Age(F=19.88, p=.000), schooling(F=5.32, p=.001), Experience(F=15.77, p=.000), position(F=13.58, p=.000) and ethical standard(F=2.63, p=.049). 5) The results of the analysis of correlation between ethical sense of value and discord(r=0.519, p=.239) showed no significant correlation statistically.

  • PDF

Fiber optic shape sensor system for a morphing wing trailing edge

  • Ciminello, Monica;Ameduri, Salvatore;Concilio, Antonio;Dimino, Ignazio;Bettini, Paolo
    • Smart Structures and Systems
    • /
    • v.20 no.4
    • /
    • pp.441-450
    • /
    • 2017
  • The objective of this work is to present a conceptual design and the modelling of a distributed sensor system based on fiber optic devices (Fiber Bragg Grating, FBG), aimed at measuring span-wise and chord-wise variations of an adaptive (morphing) trailing edge. The network is made of two different integrated solutions for revealing deformations of the reference morphing structure. Strains are confined to typical values along the span (length) but they are expected to overcome standard ranges along the chord (width), up to almost 10%. In this case, suitable architectures may introduce proper modulations to keep the measured deformation low while preserving the information content. In the current paper, the designed monitoring system combines the use of a span-wise fiber reinforced patch with a chord-wise sliding beam. The two elements make up a closed grid, allowing the reconstruction of the complete deformed shape under the acceptable assumption that the transformation refers to regular geometry variations. Herein, the design logic and some integration issues are reported. Preliminary experimental test results are finally presented.

Heat Transfer Measurement Using a Transient Liquid Crystal Technique and Numerical Anlysis (과도액정기법을 이용한 열전달 측정 및 수치해석)

  • Hong Cheol-Hyun;Lee Ki-Baik;Yang Jang-Sik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.29 no.1
    • /
    • pp.68-77
    • /
    • 2005
  • A transient liquid crystal technique has become one of the most effective ways in measuring the local heat transfer coefficients on the entire surface. The key Point of this technique is to convert the inlet flow temperature into an exponential temperature profile using a mesh heater. In order to verify the validity of this technique. the heat transfer characteristics on the wall surface by a pair of longitudinal vortices is investigated experimently and numerically. A standard ${\kappa}-{\varepsilon}$ is used for the numerical analysis of turbulent flow field. It is found from experiment and numerical analysis that two peak values exist over the whole domain. as the longitudinal vortices move to the farther downstream. these peak values decrease and the dimensionless averaged Nusselt number with the lapse of time is maintained nearly at constant values. The experiment results obtained from the present experiment in terms of the transient liquid crystal technique are in good agreement with the numerical results. Therefore, the transient liquid crystal technique developed for the measurement of heat transfer coefficient is proved to be a valid method.

Imputation of Missing Data Based on Hot Deck Method Using K-nn (K-nn을 이용한 Hot Deck 기반의 결측치 대체)

  • Kwon, Soonchang
    • Journal of Information Technology Services
    • /
    • v.13 no.4
    • /
    • pp.359-375
    • /
    • 2014
  • Researchers cannot avoid missing data in collecting data, because some respondents arbitrarily or non-arbitrarily do not answer questions in studies and experiments. Missing data not only increase and distort standard deviations, but also impair the convenience of estimating parameters and the reliability of research results. Despite widespread use of hot deck, researchers have not been interested in it, since it handles missing data in ambiguous ways. Hot deck can be complemented using K-nn, a method of machine learning, which can organize donor groups closest to properties of missing data. Interested in the role of k-nn, this study was conducted to impute missing data based on the hot deck method using k-nn. After setting up imputation of missing data based on hot deck using k-nn as a study objective, deletion of listwise, mean, mode, linear regression, and svm imputation were compared and verified regarding nominal and ratio data types and then, data closest to original values were obtained reasonably. Simulations using different neighboring numbers and the distance measuring method were carried out and better performance of k-nn was accomplished. In this study, imputation of hot deck was re-discovered which has failed to attract the attention of researchers. As a result, this study shall be able to help select non-parametric methods which are less likely to be affected by the structure of missing data and its causes.