• Title/Summary/Keyword: Standard Measuring Technology

Search Result 390, Processing Time 0.029 seconds

Innovation in Telecom Services -Framework and Analysis Based on the Case of International Pre-paid Calling Cards in Japan

  • Kumiko, Miyazaki;Wiggers, Edmar
    • Journal of Technology Innovation
    • /
    • v.13 no.2
    • /
    • pp.45-70
    • /
    • 2005
  • Much work on innovation has focused on the manufacturing sector. In this paper, we propose a framework for analyzing innovation in services centred on capability and technology integration. We illustrate the theoretical points made by conducting a case study on an international telephone communications provider Brastel, which introduced significant innovations in international calling services, in the form of rechargeable pre-paid calling card, through effective application of standard IT. Brastel is situated against its main competitors, considering two dimensions of price and service breadth and convenience. A novel technique for measuring competitiveness based on price and service index is introduced. The following competitors were selected: NTT, KDDI, Japan Telecom, Fusion Communications, J-Call / World Link, G-Call, ASP Check, Primus, QuickPhone, and MCI. To create the service index, factors such as ease of use, convenience, number of languages in which the services are available, and additional features were taken into account. The company itself and the rechargeable card innovation were analyzed through in-depth interviews and data collection. It was shown that a competitive advantage was maintained through internal and external capabilities.

  • PDF

Development of Displacement Measuring Sensor Module to Monitoring About Variation and Distortion for Bridge Infrastructure at Wireless Communication Environmental (교량구조물의 구조적 변형을 측정하는 무선통신기반 변위센서모듈 개발)

  • Ryu, Seung-Ki;Moon, Hak-Yong
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.5
    • /
    • pp.87-95
    • /
    • 2010
  • Lots of bridge structure generated the change of outward formation according to durability capability and decrepitude by long use. Especially, in case of the typhoon, snowing and earthquake is going to make rapidly more worse formation about the old structural facilitys. Also, outward formation by irregular and micro-distortion in bridge structure could not easily checked by normal diagnostics method. As a result, performance-capability of structure facility is getting to make a decline in standard of structure performance. Recently, real-time monitoring technology by wireless environment go into the study of irregular movement for structure facility. This paper presents the development of sensor to displacement checking about bridge structure. Sensing method of developed sensor put bring into the gyroscope technology using the acceleration speed and angular acceleration speed. This paper also will simulated to verified the monitoring capability of developed sensor against random vibration, frequency and distortion in simulated equipment.

Constructing Topographies of EMF Risks from Underground Power Lines (전자파 위험 지형도의 상이한 구성: 지중 송전선로 위험 논쟁을 중심으로)

  • Kim, JooHui
    • Journal of Science and Technology Studies
    • /
    • v.19 no.3
    • /
    • pp.119-166
    • /
    • 2019
  • The risk of electromagnetic field(EMF) from power lines has been heavily disputed whenever high-voltage power line towers were built in South Korea. Local communities and civic groups had regarded burying the lines in the ground as an alternative to building power line towers. In 2014, however, when an elementary school science teacher reported the results of EMF measurements over the underground power lines to the Asian Citizens' Center for Environment and Health (ACCEH), the risk controversy over underground power lines took a whole new turn. The level of EMF from underground power lines turned out to be higher, and therefore more harmful than that from power line towers. In the debates that took place from then on over the EMF risk, ACCEH and NIER(National Institute of Environmental Research) presented conflicting topographies of EMF risk. This paper examines measuring practices of ACCEH and NIER by analyzing the measuring sites, measuring devices, and measuring heights chosen by each organization. This paper further examines how ACCEH and NIER mobilized various standards(EMF exposure limit, measurement guideline, categorization of carcinogens) differently. This controversy on the EMF from underground power lines of Seoul has raised concerns on the non-thermal effects of EMF in the long-term exposure and has led people to question whether burying the power lines is the safe alternative to building power line towers. Furthermore, this suggests conflicting answers on whether Seoul, where 90 % of transmission lines were already buried, is a safely managed place or not.

The reliability of dual rehabilitative ultrasound imaging measurements for muscle co-activation

  • Hahn, Joohee;Ha, Hyun-Geun;Lee, Hwang-Jae;Lim, Seungyeop;Lee, Wan-hee
    • Physical Therapy Rehabilitation Science
    • /
    • v.6 no.3
    • /
    • pp.152-157
    • /
    • 2017
  • Objective: The aim of this study was to determine the intra-rater and inter-rater reliability of the dual rehabilitative ultrasound imaging (D-RUSI) when simultaneously measuring muscle thickness changes at rest and during co-contraction of the biceps brachii (BB) and triceps brachii (TB). Design: Cross-sectional study. Methods: This study included 36 healthy participants (23 men, 13 women). The participants sat on a chair in a comfortable position with a cushion placed under their elbow to maintain a 90-degree elbow flexion angle. The muscle thickness of the biceps brachii and triceps brachii was measured twice using the D-RUSI by two examiners during resting and co-contraction states. One week later, the same procedure was performed once again. Results: The intra-class correlation coefficients (ICCs) for intra-rater reliability ranged from 0.887 to 0.989 and the confidence interval was within an acceptable range of 0.778 to 0.994. The standard error of measurement (SEM) values ranged from 0.303 to 0.866 and the minimal detectable change (MDC) values ranged from 0.84 to 2.40. The ICCs for inter-rater reliability ranged from 0.758 to 0.925. The SEM values ranged from 0.702 to 1.486 and the MDC values ranged from 1.95 to 4.12. Conclusions: The use of the D-RUSI of the BB muscle had a very good intra-rater reliability and very good inter-rater reliability at the resting state, and a, good inter-rater reliability at the co-activation state. ICC values showed very good intra-reliability and inter-reliability for the TB muscle. the D-RUSI is a useful tool for simultaneously measuring the thickness of two muscles when the BB is an agonist and the TB is an antagonist during co-activation of the upper arm.

Non-restraint Master Interface of Minimally Invasive Surgical Robot Using Hand Motion Capture (손동작 영상획득을 이용한 최소침습수술로봇 무구속 마스터 인터페이스)

  • Jang, Ik-Gyu
    • Journal of Biomedical Engineering Research
    • /
    • v.37 no.3
    • /
    • pp.105-111
    • /
    • 2016
  • Introduction: Surgical robot is the alternative instrument that substitutes the difficult and precise surgical operation; should have intuitiveness operationally to transfer natural motions. There are limitations of hand motion derived from contacting mechanical handle in the surgical robot master interface such as mechanical singularity, isotropy, coupling problems. In this paper, we will confirm and verify the feasibility of intuitive Non-restraint master interface which tracking the hand motion using infra-red camera and only 3 reflective markers without the hardware handle for the surgical robot master interface. Materials & methods: We configured S/W and H/W system; arranged 6 infra-red cameras and attached 3 reflective markers on hands for measuring 3 dimensional coordinate then we find the 7 motions of grasp, yaw, pitch, roll, px, py, pz. And we connected Virtual-Master to the slave surgical robot(Laparobot) and observed the feasibility. To verify the result of motion, we compare the result of Non-restraint master and that of clinometer (and protractor) through measuring 0~180 degree, 10degree interval, 1000 samples and recorded standard deviation stands for error rate of the value. Results: We confirmed that the average angle values of Non-restraint master interface is accurately corresponds to the result of clinometer (and protractor) and have low error rates during motion. Investigation & Conclusion: In this paper, we confirmed the feasibility and accuracy of 3D Non-restraint master interface that can offer the intuitive motion of non-contact hardware handle. As a result, we can expect the high intuitiveness, dexterousness of surgical robot.

Measurement of the Time Taken for Initial Water Discharge According to the Number of Kinks in the Fire Hose of the Indoor Hydrant System

  • Hong, Suk-Hwan;Kong, Ha-Sung
    • International Journal of Advanced Culture Technology
    • /
    • v.9 no.3
    • /
    • pp.360-366
    • /
    • 2021
  • In this study, we tried to examine how the kinking of the fire hose affects the time taken for initial water discharge by measuring and analyzing the time taken for initial water discharge with different number of kinks at different locations of the hose. The average time taken for initial water discharge was obtained by measuring the time in the unkinked state of the fire hose. Based on this standard, we conducted the experiment by selecting the kinking locations in the hose near the water outlet and nozzle, and setting the number of kinks to 3, 6, 9, and 12. The results of this study are as follows: First, if the fire hose has 5 kinks or more near the nozzle, no water was released. Second, when comparing the case of no kinks and 4 kinks near the nozzle, there was no significant difference in the time taken for initial water discharge. Third, when the fire hose was kinked 10 times near the outlet, the time required for initial water discharge increased by 1.62 seconds on average compared to the case with no kinking, but there was no problem with water discharge. Lastly, regarding the kinking locations of the fire hose, it was found that the greater the number of kinks near the nozzle than near the outlet, the greater the effect on the discharge. As a result, it is concluded that it would be preferable to install non-kinking devices near the nozzle of the fire hose.

Uncertainty evaluation of the analysis of 11-nor-9-carboxy-Δ9-tetrahydrocannabinol in hair by GC-NCI-MS/MS (GC-NCI-MS/MS를 이용한 모발 중 대마 대사체 분석의 측정불확도 평가)

  • Kim, Jin-Young;Lee, Jae-Il;Cheong, Jae-Chul;Suh, Yong-Jun;In, Moon-Kyo
    • Analytical Science and Technology
    • /
    • v.24 no.1
    • /
    • pp.1-9
    • /
    • 2011
  • We described an estimation of measurement uncertainty in quantitative analysis of 11-nor-9-carboxy-${\Delta}^9$-tetrahydrocannabinol (THC-COOH), the metabolite of ${\Delta}^9$-tetrahydrocannabinol, in hair samples by using the bead-assisted liquid-liquid extraction and gas chromatography-tandem mass spectrometric (GC-NCI-MS/MS) detection. Traceability of measurement was established through the use of reference materials, calibrated volumetric tubes, volume measuring devices, and measuring instruments. The analytical results were compared and the different contributions to the uncertainty were evaluated. Inter-day variation was performed by using statistical analysis of several indicative factors. Measurement uncertainty associated with the analyte in real forensic hair samples were estimated using QC data. The major factor of contribution to combined standard uncertainty was inter-day repeatability, while those associated with preparation of analytical standard and also sample of weight were insignificant considering the degree of contribution. Relative uncertainty of relative extended standard uncertainty divided into the measured concentration of the analyte was 17% in a hair sample. The uncertainty of result evaluation will be invaluable to improve quality of the analysis.

Scalable Inductor Modeling for $0.13{\mu}m$ RF CMOS Technology ($0.13{\mu}m$ RF CMOS 공정용 스케일러블 인덕터 모델링)

  • Kim, Seong-Kyun;Ahn, Sung-Joon;Kim, Byung-Sung
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.46 no.1
    • /
    • pp.94-101
    • /
    • 2009
  • This paper presents scalable modeling of spiral inductors for RFIC design based on $0.13{\mu}m$ RF CMOS process. For scalable modeling, several inductor patterns are designed and fabricated with variations of width, number of turns and inner radius. Feeding structures are optimized for accurate de-embedding of pad effects. After measuring the S parameters of the fabricated patterns, double-$\pi$ equivalent circuit parameters are extracted for each device and their geometrical dependences are modeled as scalable functions. The inductor library provides two types of models including standard and symmetric inductors. Standard and symmetric inductors have the range of $0.12{\sim}10.7nH$ and $0.08{\sim}13.6nH$ respectively. The models are valid up to 30GHz or self-resonance frequency. Through this research, a scalable inductor library with an error rate below 10% is developed for $0.13{\mu}m$ RF CMOS process.

Analysis of Process Capability Index for Multiple Measurements (다측정 공정능력지수의 특성분석)

  • Lee, Do-Kyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.39 no.1
    • /
    • pp.91-97
    • /
    • 2016
  • This study is concerned about the process capability index in single process. Previous process capability indices have been developed for the consistency with the nonconforming rate due to the process target value and skewness. These indices calculate the process capability by measuring one spot in an item. But the only one datum in an item reduces the representativeness of the item. In addition to the lack of representativeness, there are many cases that the uniformity of the item such as flatness of panel is absolutely important. In these cases, we have to measure several spots in an item. Also the nonconforming judgment to an item is mainly due to the range not due to the standard variation or the shift from the specifications. To imply the uniformity concept to the process capability index, we should consider only the variation in an item. It is the within subgroup variation. When the universe is composed of several subgroups, the sample standard deviation is the sum of the within subgroup variation and the between subgroup variation. So the range R which represents only the within subgroup variation is the much better measure than that of the sample standard deviation. In general, a subgroup contains a couple of individual items. But in our cases, a subgroup is an item and R is the difference between the maximum and the minimum among the measured data in an item. Even though our object is a single process index, causing by the subgroups, its analytic structure looks like a system process capability index. In this paper we propose a new process capability index considering the representativeness and uniformity.

Identification of Armeniacae Semen and Persicae Semen (행인과 도인의 감별기준감별기준)

  • Lee, Seungho;Kim, Youngsik;Kim, Junghoon;Lee, Guemsan;Choi, Goya;Ju, Youngsung
    • The Korea Journal of Herbology
    • /
    • v.29 no.4
    • /
    • pp.61-67
    • /
    • 2014
  • Objectives : To present a differential standard of Armeniacae Semen and Persicae Semen that are easily confused. Methods : It was planed a differential standard form through outer appearance of the original plant, outer appearance in the form of each medicines and the appearance of the interior form through a microscope for each samples. Using an standard compound amygdalin, each samples have been analyzed by HPLC and TLC. Results : It was possible to distinguish the orignal plant between Armeniacae Semen and Persicae Semen through its leaf shape and calyx type. In Outer appearance in the form of each medicines, there was no difference pre-existing method(measuring length and width). In vascular pattern of the surface, however, there was a clear difference that Armeniacae Semen was developed more reticulated branches than Persicae Semen. In appearance through a microscope, it has not been possible to find a clear difference in the per original plant. However, there was a clear difference between Armeniacae Semen(1 layer) and Persicae Semen(3 layer) in inner albubemen cell. In TLC analysis, there was no difference in the pattern between samples. But in HPLC analysis, Armeniacae Semen showed amygdalin content higher on average. Conclusions : It will be possible to find various differences in the outer appearance of the original plant, the outer appearance in the form of each medicines, the appearance of the interior form through a microscope and physical and chemical research component.