• Title/Summary/Keyword: Standard Image

검색결과 2,196건 처리시간 0.03초

Character Segmentation in a Grayscale Image using the Standard Deviation (그레이스케일 영상에서 표준 편차를 이용한 문자 분할)

  • Jung, Min Chul
    • Journal of the Semiconductor & Display Technology
    • /
    • 제11권2호
    • /
    • pp.27-31
    • /
    • 2012
  • This paper proposes a new method of character segmentation in a grayscale image using the standard deviation. Firstly, the proposed method scans vertically the region of interest in an image in order to calculate a standard deviation for each scan line. Characters' standard deviations are much bigger than the background's. Therefore, it is possible to segment characters vertically using the differentiation of those two types of standard deviations. Secondly, the method scans each vertically segmented image horizontally at this time, and then segments each image similarly. The proposed method is implemented using C language in an embedded Linux system for a high-speed real-time image processing. Experiments were conducted by using credit card images. The results show that the proposed algorithm is quite successful for most credit cards. However, the method fails in some credit cards with strong background patterns.

Extended JPEG Progressive Coding for Medical Image Archiving and Communication (확장 JPEG 표준을 이용한 점진식 의료 영상 압축)

  • Ahn, Chang-Beom;Han, Sang-Woo;Kim, Il-Yeon
    • Journal of Biomedical Engineering Research
    • /
    • 제15권2호
    • /
    • pp.175-182
    • /
    • 1994
  • The international standard for digital compression and coding of continuous-tone still image known as JPEG (Joint Photographic Experts Group) standard is investigated for medical image archiving and communication. The JPEG standard has widely been accepted in the areas of electronic image communication, computer graphics, and multimedia applications, however, due to the lossy character of the JPEG compression its application to the field of medical imaging has been limited. In this paper, the JPEG standard is investigated for medical image compression with a series of head sections of magnetic resonance (MR) images (256 and 4096 graylevels, $256 {\times}256$size). Two types of Huffman codes are employed, i. e., one is optimized to the image statistics to be encoded and the other is a predetermined code, and their coding efficiencies are examined. From experiments, compression ratios of higher than 15 were obtained for the MR images without noticeable distortion. Error signal in the reconstructed images by the JPEG standard appears close to random noise. Compared to existing full-frame bit-allocation technique used for radiological image compression, the JPEG standard achieves higher compression with less Gibb's artifact. Feature of the progressive image build-up of the JPEG progressive coding may be useful in remote diognosis when data is transmitted through slow public communication channel.

  • PDF

A study on the effect of JPEG recompression with the color image quality (JPEG 재압축이 컬러 이미지 품질에 미치는 영향에 관한 연구)

  • 이성형;조가람;구철희
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • 제18권2호
    • /
    • pp.55-68
    • /
    • 2000
  • Joint photographic experts group (JPEG) is a standard still-image compression technique, established by the international organization for standardization (ISO) and international telecommunication standardization sector (ITUT). The standard is intended to be utilized in the various kinds of color still imaging systems as a standard color image coding format. Because JPEG is a lossy compression, the decompressed image pixel values are not the same as the value before compression. Various distortions of JPEG compression and JPEG recompression has been reported in various papers. The Image compressed by JPEG is often recompressed by same type compression method in JPEG. In general, JPEG is a lossy compression and the quality of compressed image is predicted that is varied in according to recompression Q-factor. In this paper, four difference color samples(photo image, gradient image, gradient image, vector drawing image, text image) were compressed in according to various Q-factor, and then the compressed images were recompressed according to various Q-factor once again. As the result, this paper evaluate the variation of image quality and file size in JPEG recompression and recommed the optimum recompression factor.

  • PDF

THE IMAGE OF THE MAXILLARY SINUSES IN THE PANORAMIC RADIOGRAPH (파노라마 X선사진에서의 상악동상)

  • Choi Soon-Chul
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • 제21권2호
    • /
    • pp.157-163
    • /
    • 1991
  • The author has evaluated the panoramic image of the maxillary sinus according to the skull position. The lead foils were attached to the five walls of the maxillary sinus and the inferior turbinate individually. The skull was located in three positions; standard position, 20㎜ forward position and chin-down position. The obtained results were as follows: 1. In standard position, the medial wall was superimposed upon most of the panoramic antral image. The anterior wall and the posterolateral wall were superimposed upon the medial half and the lateral third respectively. 2. In forward position, the width of the panoramic antral image was diminished generally. The anterior wall was superimposed upon most of the panoramic antral image and the posterolateral wall appeared narrowly at the most lateral portion of the panoramic antral image. 3. In chin-down position, there was no significant difference in comparison to the standard position. 4. Inferior turbinate was not superimposed upon the panoramic antral image.

  • PDF

Evaluation of Various Tone Mapping Operators for Backward Compatible JPEG Image Coding

  • Choi, Seungcheol;Kwon, Oh-Jin;Jang, Dukhyun;Choi, Seokrim
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • 제9권9호
    • /
    • pp.3672-3684
    • /
    • 2015
  • Recently, the standardization of backward compatible JPEG image coding for high dynamic range (HDR) image has been undertaken to establish an international standard called "JPEG XT." The JPEG XT consists of two layers: the base layer and the residual layer. The base layer contains tone mapped low dynamic range (LDR) image data and the residual layer contains the error signal used to reconstruct the HDR image. This paper gives the result of a study to evaluate the overall performance of tone mapping operators (TMOs) for this standard. The evaluation is performed using five HDR image datasets and six TMOs for profiles A, B, and C of the proposed JPEG XT standard. The Tone Mapped image Quality Index (TMQI) and no reference image quality assessment (NR IQA) are used for measuring the LDR image quality. The peak signal to noise ratio (PSNR) is used to evaluate the overall compression performance of JPEG XT profiles A, B, and C. In TMQI and NR IQA measurements, TMOs using display adaptive tone mapping and adaptive logarithmic mapping each gave good results. A TMO using adaptive logarithmic mapping gave good PSNRs.

Wavelet Transform Based Image Template Matching for Automatic Component Inspection (자동부품검사를 위한 웨이블렛 변환 기반 영상정합)

  • Cho, Han-Jin;Park, Tae-Hyoung
    • Journal of Institute of Control, Robotics and Systems
    • /
    • 제15권2호
    • /
    • pp.225-230
    • /
    • 2009
  • We propose a template matching method for component inspection of SMD assembly system. To discriminate wrong assembled components, the input image of component is matched with its standard image by template matching algorithm. For a fast inspection system, the calculation time of matching algorithm should be reduced. Since the standard images of all components located in a PCB are stored in computer, it is desirable to reduce the memory size of standard image. We apply the discrete wavelet transformation to reduce the image size as well as the calculation time. Only 7% memory of the BMP image is used to discriminate goodness or badness of components assembly. Comparative results are presented to verify the usefulness of the proposed method.

Metadata Mapping for Image Retrieval in Distributed Web Environments (분산 웹 환경에서 이미지 검색을 위한 메타데이타 매핑)

  • Kwon, Eun-Young;Na, Yun-Mook;Ahn, Chul-Bum
    • Journal of Korea Multimedia Society
    • /
    • 제9권7호
    • /
    • pp.782-800
    • /
    • 2006
  • Image metadata is used to describe the contents, structures, and features of a given image data. There exist lots of image metadata-related standards. Such image metadata need to be shared to efficiently search the correct images in Web Service-enabled distributed environments. In this thesis, we propose an interoperable system architecture for utilizing image metadata and query extension methods using metadata mapping for correct and efficient image searching. In the proposed methods, the provider schema using non-standard image metadata are mapped into the schema based on the VRA standard, which is used as a basic and intermediary standard in MDR(MetaData Registry). We support mapping operations between the VRA standard and other standards, to reduce the number of unnecessary mapping operations and to enable easier addition of schema based on new standards. Using the proposed query processing methods, which utilize image metadata and overcome their heterogeneity by metadata mapping, it is possible to severely improve the correctness of image retrieval. To show the usefulness of our schemes, we implemented a prototype system and performed retrieval performance evaluation on extended query processing.

  • PDF

A Study on the Image of the Girls' High School Uniform Design (여고생의 교복 디자인에 따른 이미지 연구)

  • Yang, Eunjin;Jeong, Sujin
    • Journal of the Korea Fashion and Costume Design Association
    • /
    • 제18권2호
    • /
    • pp.237-251
    • /
    • 2016
  • The purpose of this study is to provide the improvement idea for an school uniform styling that better satisfies female high school students' changing demands, through evaluating images differences according to design variation in school uniforms. This study was carried out with a between-subject design by using the stimulant materials of school uniform design and image assessment scale. The stimulant materials used for this study were 27 designs with blazer/skirt ensemble and 21 designs with vest/skirt ensemble. The survey materials were collected through a questionnaire from a total of 192 female high school students living in Gyeongsangnam-do. As a result of analyses on a image of blazer/skirt ensembles, 4 factors were extracted such as neatness, uniqueness, activeness, and attractiveness. Blazer was the only variables that exerted significant effects on neatness, uniqueness, and attractiveness. As a result of analyses on a image of vest/skirt ensembles, 4 factors were extracted such as attractiveness, neatness, uniqueness, and activeness. Skirt was the only variables that exerted significant effects on attractiveness, neatness, and uniqueness. Neat image was perceived to be high in ensembles of standard blazer/standard collar/horizontal-seam skirt, standard vest/skirt with horizontal color combination, and buttons-down vest/horizontal-seam skirt. Unique image was perceived to be high in ensembles of blazer with bindings/standard collar/solid skirt, and vest with pockets/skirt with vertical bindings. Also, active image was perceived to be high in ensembles of vest with pockets/skirt with vertical bindings, and buttons-down vest/skirt with vertical bindings. Attractive image was perceived to be high in ensembles of blazer with bindings/peaked lapel/skirt with vertical bindings, and standard vest/horizontal-seam skirt. In conclusion, this study reveals that different items and pieces of school uniforms can be combined in many different ways to create quite diverse looks. Thus, this study provides important basic data for research on teenagers' fashion and clothing.

  • PDF

A Study on the effect of JPEG recompression with the color image quality (JPEG 재 압축이 컬러 이미지 품질에 미치는 영향에 관한 연구)

  • 이성형;구철회
    • Proceedings of the Korean Printing Society Conference
    • /
    • 한국인쇄학회 2000년도 춘계 학술발표회 논문집
    • /
    • pp.17-24
    • /
    • 2000
  • The Joint Photographic Experts Group (JPEG) is a standara still-image compression technique, established by the International for Standardization (ISO) and International Telecommunication Standardization Sector (ITUT). The standard is intended to be utilized in the various kinds of color still imaging systems as a standard color image coding format. Because JPEG is a lossy compression, the decompressed image pixel values are nto the same as values before compression. Image of JPEG compression is often made to JPEG recompression at saving to apply JPEG compression of color image. In general, JPEG is a lossy compression and compression image is predicted to be varied image quality according to recompressed Q-factor. Various distortions of JPEG compression and JPEG recompression has been reported in previous paper. In this paper, we compress four difference color samples (photo image, gradient image, vector drawing image, text image) according to various Q-factor, and then compressed images are recompressed according to various Q-factor once again. As the results, we inspect variation of quality and file size of recompressed color image, and ensure the optimum recompression factor.

The Accuracy of the Radiographic Method in Root Canal Length Measurement (근광장 측정에서 방사선 사진술의 정확도)

  • Jo Eun-Young;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • 제28권2호
    • /
    • pp.471-489
    • /
    • 1998
  • For the successful endodontic treatment, root canal should be cleaned thoroughly by accurate mechanical and chemical canal preparation and sealed completely with canal filling material without damaging the periapical tissues. The accuracy of the root canal length measurement is a prerequisite for the success of the endodontic treatment, and the root canal length is often determined by the standard periapical radiographs and digital tactile sense. In this study, the accuracy and the clinical usefulness of Digora/sup (R)/, an intraoral digital imaging processor and the conventional standard radiographs were compared by measuring the length from the top of the file to the root apex. 30 single rooted premolars were invested in a uniformly sized blocks and No.25 K-file was inserted into and fixed in each canal. Each block was placed in equal distance and position to satisfy the principle of the bisecting angle and paralleling techniques and Digora/sup (R)/ system's image and standard periapical radiographs were taken. Each radiograph was examined by 3 different observers by measuring the length from top of the file to the root apex and each data was compared and analyzed. The results were as follows; 1. In the bisecting angle technique, the average difference between the Digora/sup (R)/ system and standard periapical radiograph was 0.002 mm and the standard deviation was 0.341 mm which showed no statistically significant difference between the two systems(p>0.05). Also, in the paralleling technique, the average difference between these two system was 0.007 mm and the standard deviation was 0.323 mm which showed no statistically significant difference between the two systems(p>0.05). 2. In Digora/sup (R)/ system, the average difference between the bisecting angle and paralleling technique was -0.336 mm and the standard deviation was 0.472 mm which showed a statistically significant difference between the two techniques(p<0.05). Also, in the standard periapical radiographs, the average difference between the bisecting angle and paralleling technique was 0.328 mm and the standard deviation was 0.517 mm which showed a statistically significant difference between these two techniques(p<0.05). 3. In Digora/sup (R)/ system and the standard periapical radiographs. there was a statistically significant difference between the measurement using the bisecting angle technique and the actual length(p<0.05), But there was no statistically significant difference between the measurement using the paralleling technique and the actuallength(p>0.05). In conclusion. the determination of the root canal length by using the Digora/sup (R)/ system can give us as good an image as the standard periapical radiograph and using the paralleling technique instead of the bisecting angle technique can give a measurement closer to the actual canal length. thereby contributing to a successful result. Also. considering the advantages of the digital imaging processor such as decreasing the amount of exposure to the patient. immediate use of the image. magnification of image size. control of the contrast and brightness and the ability of storing the image can give us good reason to replace the standard periapical radiographs.

  • PDF