• Title/Summary/Keyword: Stand-by Power

Search Result 332, Processing Time 0.033 seconds

Simulator Development for Stand Alone PV System Design (태양광발전 시스템 설계를 위한 시뮬레이터 개발)

  • Kang, S.Y.;Kim, K.H.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.383-388
    • /
    • 2003
  • The stand alone PV system's stability and cost is influenced by a design method, as its application products are various. In order to systematize the the stand alone PV system's design method based on experience, this research settled the capacity computation method of PV module and battery and developed a simulator. And Its characteristic is confirmed by applying to PV street lamp design.

  • PDF

A Study on the Economic of Electrical Storage Device of Stand Alone PV/Wind Hybrid System Based upon Sunless Days (부조일에 따른 독립형 태양광 풍력 복합발전 시스템에서 전기저장장치의 경제성에 관한 연구)

  • Choi, Byoung-Soo;Kim, Jae-Chul
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.3
    • /
    • pp.16-23
    • /
    • 2012
  • This paper relates to a study on the economic of electrical storage device for supplying power in sunless days, in the stand alone PV/Wind hybrid system, which it is applied to separate houses. In a photovoltaic/wind hybrid power system used in a separate house, when only the battery is used in sunless days, the capacity of the battery is become larger. For example, as in recent days, if cloudy days are frequent due to anomaly climate, it is difficult to supply power stably by only the battery based upon pre-estimated sunless days. Accordingly, in order to supply stably power of new renewable energy such as solar to any separate houses, it is preferable to reduce the capacity of battery by decreasing the number of sunless days when estimating the capacity of battery and to drive the small generator for compensation of the power shortage.

Optimization of Stand-Alone Hybrid Power Systems Using HOMER Program (HOMER 프로그램을 이용한 독립형 하이브리드 발전시스템 최적화)

  • Yang, Su-Hyung;Boo, Chang-Jin;Kim, Ho-Chan
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.2
    • /
    • pp.11-18
    • /
    • 2012
  • Diesel fuel is expensive because transportation to remote areas adds extra cost, and it causes air pollution by engine exhaust. Providing a feasible economical and environmental solution to diesel generators is important. A hybrid system of renewable plants and diesel generators can benefit islands or other isolated communities and increase fuel savings. Renewable energy is, however, a natural source that produces a fluctuating power output. In this paper, hybrid power system of the marado lighthouse is proposed to supply stable power in the stand-alone hybrid power system. The proposed hybrid power system consists of the diesel generator, wind turbine, photovoltaic, fuel cell, and battery bank. To decrease the carbon emissions and find the optimization, the cost analysis of hybrid system is simulated using HOMER program and the optimized hybrid power system is designed.

Development of a 10kw stand-alone power processing unit for SOFC (고체산화물형 연료전지를 위한 10㎾급 독립전력변환장치의 개발)

  • 이진희;조진상;장민수;최세완;한수빈
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.8 no.6
    • /
    • pp.551-560
    • /
    • 2003
  • This paper summarizes development of a 10KW stand-alone power processing unit for 5KW SOFC-low voltage battery hybrid fuel cell power generation system. The power processing unit Includes three parts a high frequency DC-DC converter boosts low fuel cell voltage, a DC-AC inverter converts a dc voltage into a regulated ac voltage and a bidirectional DC-DC converter charges or discharges the battery. The converter topology, design, control method, and experimental result arc presented to meet the specifications such as efficiency of 90% and cost of $40/KW laid down for the "2003 Future Energy Challenge Competition" organized by the U.S. Department of Energy and IEEE. and IEEE.

MPPT Control Method comparison of the Stand-alone PV system (독립형 태양광 발전시스템의 MPPT 제어기법 비교)

  • Lee, Yong-Sik;Kim, Nam-In;Jeong, Sung-Won;Gim, Jae-Hyeon
    • Proceedings of the KIEE Conference
    • /
    • 2011.07a
    • /
    • pp.1386-1387
    • /
    • 2011
  • Maximum power point tracking(MPPT) techniques are used in photovoltaic systems to maximize the PV array output power by tracking continuously the maximum power point which depends on panels temperature and on irradiance conditions. In this paper, the controller of the stand-alone PV system applicable to various fields are designed. The improved P&O MPPT and traditional P&O MPPT method was applied. This improved algorithm consists of a constant perturbation with an step control which will make easier the controller PV power data acquisition process. This strategy of control has, in first time, been validated by PSIM simulations. After, been field test. The experimental results show that the improved P&O method increased the PV output power compare to traditional P&O method.

  • PDF

Development of the Low Power Stand-Alone Smoke and Heat Detector for the Reliability Improvement (신뢰성 개선을 위한 저전력 열연 복합식 단독경보형 감지기 개발)

  • Jee, Seung-Wook;Kim, Si-Kuk;Lee, Jae-Jin;Kim, Pil-Young;Lee, Chun-Ha
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.74-79
    • /
    • 2012
  • This study is described for development of the stand-alone smoke and heat detector (SASHD) according to the revised in 2011 type approval and performance inspection code for detector. The main improvement of the revised regulation is source. CMOS microcontroller with nano watt technology is use for development of the workable SASHD over 10 years. The low-power SASHD is developed by using the power-saving sleep mode of microcontroller, by making the low-power source voltage checker, heat detector and smoke detector. The stand-alone detector is developed by smoke and heat detector type for reduce false fire alarm. User can choose type of work between the heat detection mode and smoke & heat detection mode. The SASHD can communicate with each them using RS-485 communication supported from microcontroller. So, this study can develop the SASHD that is able to alarm more wide area when fire occurs and reduce a flash fire alarm.

Controller Design of Stand-Alone or Grid-Connected Inverter to Compensate Harmonics Caused by Nonlinear Load (비선형부하에 의해 발생하는 고조파 보상을 위한 독립형 또는 계통연계형 인버터 제어기 설계)

  • Sin, Chanho;Lim, Kyungbae;Petrus, Simatupang Desmon;Choi, Jaeho
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.5
    • /
    • pp.440-448
    • /
    • 2017
  • This paper proposes a controller design of a distributed source inverter in stand-alone mode or grid-connected mode to compensate the current or voltage harmonics caused by local nonlinear load. The PR-based multi loop controller has been used to improve the dynamic performance of the system and to compensate the output voltage or grid current harmonics. The multi-loop controller consists of an outer current controller and an inner voltage controller for the output voltage control in stand-alone mode. In grid-connected mode, an outer current controller is added to the output voltage controller for the grid current control. The design performance of each controller is described through the Root locus and Bode plot of the transfer functions. The validity of the proposed control algorithm and design parameters has been verified through the PSiM simulation and experimental results.

A Standby Mode Transition Scheme for Set-top Box Power Saving by the Use Information of External Device (외부 입력기기 사용 정보 기반 셋톱박스 대기모드 전환 기술)

  • Kim, Yong-Ho;Choi, Yun-Bum;Oh, Nam-Cul;Kim, Hoon
    • Journal of The Institute of Information and Telecommunication Facilities Engineering
    • /
    • v.9 no.4
    • /
    • pp.124-130
    • /
    • 2010
  • This paper considers a power saving technique of set-top box (STB) that turns the signal into content which is then displayed on the television (TV) screen. A traditional power saving scheme, Auto Power Down (APD), was devised to reduce the power consumption of STB. APD checks whether the user is watching TV over a period of time and enforces STB into stand-by mode when the check result reveals the user is not watching TV. This paper proposes an enhanced power saving scheme that transits STB operation mode to 'stand-by' immediately when STB recognizes the change of TV's external input signal. The proposed scheme does not require the monitoring time to check the users' watching TV, and transits to standby mode faster than the conventional APD, which results in better performance in power saving. The simulation result shows that the proposed scheme achieves 2 to 11% improvement in power consumption compared with the conventional APD.

  • PDF

A Study on Sizing of Battery for Effective Operation of Stand-alone Renewable Generation System (독립형 신재생발전 시스템의 효율적인 운영을 위한 배터리 용량산정에 관한 연구)

  • Shin, Hee-Sang;Hue, Jae-Sun;Yun, Sang-Yun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.67 no.1
    • /
    • pp.15-20
    • /
    • 2018
  • This paper presents the method of ESS energy capacity calculation for stand-alone renewable energy generation system consisting of photovoltaic energy. There is almost no power from photovoltaic system during sunless days. So this source is very weak in terms of the power supply reliability. To improve problem of power supply, battery is mainly used Energy Storage System(ESS). The number of sunless days and Depth of Discharge(DOD) is important factor to determine energy capacity of battery. However, a many study for economical design is required due to the high cost of ESS. In this paper, we propose the new method of ESS energy capacity calculation by applying different DOD for operation with and without sun. We determine the Battery capacity using higher DOD of operation during sunless day than the DOD of the normal operation. And we carried out an economic analysis of the calculation results.

Vibration Monitoring and Analysis of a Small Stand Alone Wind Turbine Generator (소형 독립형 풍력발전기의 진동 모니터링 및 분석)

  • Kim S. H.;Yoo N. S.;Nam Y. S.;Lee J. W.
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.64-67
    • /
    • 2005
  • A vibration monitoring system for a small size wind turbine (WIT) is established and operated. The monitoring system consists of monolithic integrated chip accelerometer for vibration monitoring, anemometers for wind data acquisition and auxiliary sensors for atmospheric data. Using the monitoring system, vibration response of a 6kW stand alone WIT generator is investigated. Acceleration data of the WIT tower under various operation condition is acquired in real time using LabVIEW and the data are remotely transferred from the test site to the laboratory in school by internet. Vibration response characteristics of the tower structure are diagnosed in the aspect of stability of W/T. Wind data and electrical power performance are also investigated with the stability problem.

  • PDF