• Title/Summary/Keyword: Stand-alone type

Search Result 117, Processing Time 0.023 seconds

Real Weather Condition Based Simulation of Stand-Alone Wind Power Generation Systems Using RTDS

  • Park, Min-Won;Han, Sang-Geun;Yu, In-Keun
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • v.4B no.3
    • /
    • pp.146-152
    • /
    • 2004
  • Cost effective simulation schemes for Wind Power Generation Systems (WPGS) considering wind turbine types, generators and load capacities have been strongly investigated by researchers. As an alternative, a true weather condition based simulation method using a real-time digital simulator (RTDS) is experimented in this paper for the online real-time simulation of the WPGS. A stand-alone WPGS is, especially, simulated using the Simulation method for WPGS using Real Weather conditions (SWRW) in this work. The characteristic equation of a wind turbine is implemented in the RTDS and a RTDS model component that can be used to represent any type of wind turbine in the simulations is also established. The actual data related to weather conditions are interfaced directly to the RTDS for the purpose of online real-time simulation of the stand-alone WPGS. The outcomes of the simulation demonstrate the effectiveness of the proposed simulation scheme. The results also signify that the cost effective verification of efficiency and stability for the WPGS is possible by the proposed real-time simulation method.

Maximum Output Power Control for Stand-Alone Wind Power Generation System Using Cage-Type Induction Generators (농형 유도발전기를 이용한 독립형 풍력발전시스템의 최대출력제어)

  • 김형균;이동춘;석줄기
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.73-80
    • /
    • 2004
  • In this paper, a maximum output power control of stand-alone cage-type induction generator systems for wind power generation is proposed. The induction generator is operated in a vector-controlled mode, which is excited with d-axis current and of which torque is controlled with q-axis current. The generator speed is controlled by this torque, along which speed the generator produces the maximum output power. The generated power charges the battery bank for energy storage through an ac/dc PWM converter. The proposed scheme has been verified for the wind turbine simulator system which consists of M-G set.

Generation Characteristic of WEC for Buoy (브이용 파력발전시스템의 발전특성)

  • Oh, Jin-Seok;Kwak, Jun-Ho;Bae, Soo-Young;Jung, Sung-Young;Lee, Ji-Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1123-1128
    • /
    • 2008
  • Marine facilities like buoy, lighthouse are operated with stand alone power supply system. This power system can consist of a stand-alone type power system such as PV(Photovoltaic) system, wave system or hybrid system which is not cooperated with a commercial power system. Generally, PV power system for marine facilities can not supply a sufficient power to buoy, because it is so influenced from weather condition. For solving this problem the hybrid power system with PV and wave is studied on a various area, that is why a hybrid power system is requires to overcome these problems. This paper will describe a generation characteristic of WEC(Wave Energy Converter) for buoy, and an AFS(Anti-Fouling System) influence on WEC.

Adjustable Speed Control of Stand-Alone Wind Power Generation System using Squirrel-Cage Induction Generators (농형유도발전기를 이용한 독립형 풍력발전시스템의 가변속 제어)

  • Kim, Hyeung-Kyun;Lee, Kang-Ju;Lee, Dong-Choon;Seok, Jul-Ki
    • Proceedings of the KIEE Conference
    • /
    • 2003.04a
    • /
    • pp.338-340
    • /
    • 2003
  • This paper proposes a stand-alone adjustable speed wind Power generation system using a cage-type induction generator. Indirect vector control is used, where the q-axis current controls the generator speed and the d-axis current controls the excitation level. The generator speed is adjusted according to the wind speed so as to produce the maximum output power. The generated power is charged in the battery bank through ac/dc PWM converter. The proposed scheme has been verified by the experimental results.

  • PDF

Gateway Design for Network based Multi-Motor Control with CAN and Profibus (ICCAS 2005)

  • Kim, Gwan-Su;Jung, Eui-Heon;Lee, Hong-Hee
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.2221-2225
    • /
    • 2005
  • Various types of fieldbus are used in factories in order to achieve the communication between the parts of process. But the protocol of the fieldbus doesn't have the standardized unique protocol. Thus, it is hard to exchange information each other with real time base when the different type protocols are adopted in the same network. In this paper, we implement two types of gateway for CAN and Profibus-DP: PC-based gateway and stand-alone gateway using the 80186 core based Dstni-LX network processor. The performance of proposed PC-based and stand-alone gateway is verified experimentally.

  • PDF

Controller Design of Stand-Alone Photovoltaic System with Charge-Discharge Controller for Remote lsland Power Supply

  • Kang, Ki-Hwan;Yu, Gwon-Jong;Song, Jinsoo;Jeong, Young-Seok;Kang, Ki-Hwan;Lee, Byoung-Ku;Choe, Gyu-Ha
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.972-977
    • /
    • 1998
  • This paper deals with stand-alone Photovoltaic system(SPVS) with charge and discharge controller. Main power source of SPVS are generally solar cell and battery. Therefore SPVS can be classified into variable types in accordance with connection method between battery and solar cell array. Mainly used one of them is direct connection type which has advantages such as simple structure and simple controller. However most big drawback of this system is energy loss by voltage disharmony between solar cell array and battery. Therefore SPVS with charge and discharge controller which can operate solar cell array at maximum power point is designed and experimented with a laboratory prototype.

  • PDF

Anterior Lumbar Interbody Fusion with Stand-Alone Interbody Cage in Treatment of Lumbar Intervertebral Foraminal Stenosis : Comparative Study of Two Different Types of Cages

  • Cho, Chul-Bum;Ryu, Kyeong-Sik;Park, Chun-Kun
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.5
    • /
    • pp.352-357
    • /
    • 2010
  • Objective : This retrospective study was performed to evaluate the clinical and radiological results of anterior lumbar interbody fusion (ALIF) using two different stand-alone cages in the treatment of lumbar intervertebral foraminal stenosis (IFS). Methods : A total of 28 patients who underwent ALIF at L5-S1 using stand-alone cage were studied [Stabilis$^{(R)}$ (Stryker, Kalamazoo, MI, USA); 13, SynFix-LR$^{(R)}$ (Synthes Bettlach, Switzerland); 15]. Mean follow-up period was 27.3 ${\pm}$ 4.9 months. Visual analogue pain scale (VAS) and Oswestry disability index (ODI) were assessed. Radiologically, the change of disc height, intervertebral foraminal (IVF) height and width at the operated segment were measured, and fusion status was defined. Results : Final mean VAS (back and leg) and ODI scores were significantly decreased from preoperative values (5.6 ${\pm}$ 2.3 ${\rightarrow}$ 2.3 ${\pm}$ 2.2, 6.3 ${\pm}$ 3.2 ${\rightarrow}$1.6 ${\pm}$ 1.6, and 53.7 ${\pm}$ 18.6 ${\rightarrow}$ 28.3 ${\pm}$ 13.1, respectively), which were not different between the two devices groups. In Stabilis$^{(R)}$ group, postoperative immediately increased disc and IVF heights (10.09 ${\pm}$ 4.15 mm ${\rightarrow}$ 14.99 ${\pm}$ 1.73 mm, 13.00 ${\pm}$ 2.44 mm ${\rightarrow}$ 16.28 ${\pm}$ 2.23 mm, respectively) were gradually decreased, and finally returned to preoperative value (11.29 ${\pm}$ 1.67 mm, 13.59 ${\pm}$ 2.01 mm, respectively). In SynFix-LR$^{(R)}$ group, immediately increased disc and IVF heights (9.60 ${\pm}$ 2.82 mm ${\rightarrow}$ 15.61 ${\pm}$ 0.62 mm, 14.01 ${\pm}$ 2.53 mm ${\rightarrow}$ 21.27 ${\pm}$ 1.93 mm, respectively) were maintained until the last follow up (13.72 ${\pm}$ 1.21 mm, 17.87 ${\pm}$ 2.02 mm, respectively). The changes of IVF width of each group was minimal pre- and postoperatively. Solid arthrodesis was observed in 11 patients in Stabilis group (11/13, 84.6%) and 13 in SynFix-LR$^{(R)}$ group (13/15, 86.7%). Conclusion : ALIF using stand-alone cage could assure good clinical results in the treatment of symptomatic lumbar IFS in the mid-term follow up. A degree of subsidence at the operated segment was different depending on the device type, which was higher in Stabilis$^{(R)}$ group.

Smart Power Management System for Leisure-ship

  • Park, Do-Young;Oh, Jin-Seok
    • Journal of Navigation and Port Research
    • /
    • v.35 no.9
    • /
    • pp.749-753
    • /
    • 2011
  • A leisure ship has a stand-alone type power system, and a generator is in use on this condition. But the generator cannot be operated in condition of leisure activity, ocean measurement and etc, because of environment and noise. Recently, renewable energy system is connected with power system of the leisure-ship for saving energy. The renewable energy system can not supply the stable power to leisure-ship because power generation changes according to weather condition. And most of the leisure ship is operated without methodical power management system. This study's purpose is to develop SPMS(Smart Power Management System) algorithm using the renewable energy (photovoltaic, wind power and etc.). The proposed algorithm is able to supply stable the power according to operation mode. Furthermore, the SPMS manages electric load (sailing and communication equipment, TV, fan, etc.) and reduces operating times of the generator. In this paper, the proposed algorithm is realized and executed by using LabVIEW. As a result, the hour for operating the generator is minimized.

Operating Chracteristic of Power Converter for Photovoltatic System using Instantaneous Controller (순시치 제어기를 이용한 태양광발전용 전력변환장치 동작특성)

  • 유권종;김홍성;송진수;정영석;강기환;이병구;최규하
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.4 no.1
    • /
    • pp.57-65
    • /
    • 1999
  • This paper deals with stand-alone photovoltaic system(SPVS) with charge and discharge controller. Main power source of SPVS are generally solar cell and battery. Therefore SPVS can be classified into variable types in accordance with connection type between battery and solar cell. Mainly used one of them is direct connection type which has advantages such as simple structure and simple controller. However most big drawback of this system is energy loss by voltage disharmony between solar cell and battery. Therefore SPVS with charge and discharge controller which can operate solar cell at maximum power point is suggested and designed with instantaneous controller. And system operating characteristics are verifieded by experiment with a laboratory prototype in this paper.

  • PDF

The Study of Control Algorithm for Stand alone PV System (독립헝 태양광 발전 시스템의 제어 알고리즘에 관한 연구)

  • Kim, Tae-Yeop;Jung, Maeng-Hwa;Goh, Gweon-Seong
    • Proceedings of the KIEE Conference
    • /
    • 2002.07b
    • /
    • pp.1382-1384
    • /
    • 2002
  • The flooded type battery is used for solar lighting system. Because the characteristic of flooded type battery is the short life time, the maintenance cost is high. So the using flooded type battery in this system is inappropriate. The valve regulated lead acid batter.(VRLA) is the maintenance free and cycle service purpose. This paper presents the development of control system and monitoring system to applied VRLA battery for maintenance free and long life time in system.

  • PDF