• Title/Summary/Keyword: Stall

Search Result 471, Processing Time 0.021 seconds

A Study of the Stall Keeper Behavior Characterictics in Urban Area ( I ) (도시생활에 있어서 노점상의 행태특성에 관한 연구( I ))

  • 김한수
    • Journal of the Korean housing association
    • /
    • v.8 no.2
    • /
    • pp.113-122
    • /
    • 1997
  • This study analyzes behavior characteristics of illegal urban stall keepers scattered in the metropolitan area and their effects to urban life. The main findings of this study are follows. First, the stall keepers are different in terms of 1) items 2) opening hour and 3) user characteristics depending on locational environment of market boundaries. Second, the stall keepers exit in any time and any place if demand exists. Third, the effects of stall keepers to urban life are twofold ; they facilitate urban life by providing cheap and various commodities/services and they bring about negative effects such as obstacle to traffic flows, waste generation, and so on.

  • PDF

An Air Cleaning Efficiencies of Wet Air Cleaner in the Swine Finishing Winch Curtain Stall (윈치커튼식 비육돈사에서 습식공기정화기의 공기정화 효율 분석)

  • Oh, I.H.;Kim, W.G.;Lee, H.S.
    • Journal of Animal Environmental Science
    • /
    • v.14 no.2
    • /
    • pp.75-80
    • /
    • 2008
  • High concentration of $NH_3$, $CO_2$, and lots of dust are found in modern densely raising stall system, as results, they provide a negative influence on animal and lamer health, and production ability. Therefore, it is necessary to keep clean the inside of stall air to increase the productivity. A wet type air cleaner has been developed to clean the stall air. The work principle is that the inside air are sucked through the fan, and the rotating discs make a water into a fineness spray and blows into the stall. The spray can take the dust, $NH_3$, and odor from the stall inside air and give back to the circulating water, which can be refreshed in 2 hours interval. In the Present study, we measured the $NH_3$, dust, odor, temperature and humidity in a swine stall that were installed two wet air cleaners with 700 fattening swine with on-mode and off-mode of wet air cleaners. In fall, the concentrations of $NH_3$ in off-mode stall were maximum 24 ppm and minimum 16 prm, and the average was 18.2 ppm. However in on-mode stall the $NH_3$ concentrations were maximum 7ppm and minimum 1ppm, and the average was 2.7ppm. The concentration of $NH_3$ in on-mode was 74% lower than off-mode stall. Odor was measured by olfactometer. In the off-mode stall, the odor unit was 3,800 OU/$m^3$, but in the on-mode stall the odor unit was 2,100 OU/$m^3$ Odor removal efficiency was about 45% in on-mode stall. The dust measure was divided into 3 categories, $PM_{10}$, $PM_{2.5}$ and $PM_{1.0}$. Whereas the $PM_{10}$ showed no significant differences between the tests, $PM_{2.5}$ and $PM_{1.0}$ in the fine particle range reduced remarkably in the on-mode.

  • PDF

Behavior of Rotating Stall Cell in a High Specific-Speed Diagonal Flow Fan

  • Shiomi, Norimasa;Cai, W.X.;Muraoka, A.;Kaneko, K.;Setoguchi, T.
    • Journal of Mechanical Science and Technology
    • /
    • v.15 no.12
    • /
    • pp.1860-1868
    • /
    • 2001
  • An experimental investigation was carried out to clarify unsteady flow fields with rotating stall cell, especially behavior of stall cell, in a high specific-speed diagonal flow fan. As its specific-speed is vary high for a diagonal flow fan, its pressure-flow rate curve tends to indicate unstable characteristics caused by rotating stall similar to axial flow fan. Although for an axial flow fan many researchers have investigated such the flow field, for a diagonal flow fan tittle study has been done. In this study, velocity fields at rotor Inlet in a high specific-speed diagonal flow fan were measured by use of a single slant hot-wire probe. These data were processed by using the "Double Phase-Locked Averaging"(DPLA) technique, i. e. phases of both the rotor blade and the stall cell were taken into account. The behaviors of stall cell at rotor inlet were visualized for the meridional, tangential and radial velocity.

  • PDF

A Suggested Mechanism of Significant Stall Suppression Effects by Air Separator Devices in Axial Flow Fans

  • Yamaguchi, Nobuyuki
    • International Journal of Fluid Machinery and Systems
    • /
    • v.4 no.1
    • /
    • pp.57-66
    • /
    • 2011
  • Radial-vaned air separators show a strong stall suppression effect in an axial flow fans. From a survey of existing literature on the effects and the author's data, a possible mechanism for the significant effects has been proposed here. The stall suppression is suggested to have been achieved by a combination of the following several effects; (1) suction of blade and casing boundary layers and elimination of embryos of stall, (2) separation and straightening of reversed swirling flow from the main flow, (3) induction of the fan main flow toward the casing wall and enhancement of the outward inclination of meridional streamlines across the rotor blade row, thus keeping the Euler head increase in the decrease in fan flow rate, and (4) reinforcement of axi-symmetric structure of the main flow. These phenomena have been induced and enhanced by a stable vortex-ring encasing the blade tips and the air separator. These integrated effects appear to have caused the great stall suppression effect that would have been impossible by other types of stall prevention devices. Thus the author would like to name the device "tip-vortex-ring assisted stall suppression device".

Stall and Counter-measure for Large Size Axial-Flow Fan (대형축류팬의 실속과 대책)

  • Shim, Eui-Bo
    • 유체기계공업학회:학술대회논문집
    • /
    • 1998.12a
    • /
    • pp.70-77
    • /
    • 1998
  • The rise in pressure across the impeller blade of an axial flow fan depends on the angle of attack. At a low back pressure, the air volume will be large and the angle of attack is small. The gradual increase of the back pressure approached stall zone which is not stationary but travels blade to blade passage. In consequence, a region occurs around these blades with large vibration in the flow. To avoid these stall operation, the stall detector in the axial flow fans has been designed to detect stalling condition with a manometer or differential pressure switch by electric mechanism.

  • PDF

Development of Fan Stall Warning guard System using DCS (분산제어설비를 이용한 공기맥동 감시 시스템 개발)

  • 조현섭
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.16 no.2
    • /
    • pp.65-70
    • /
    • 2002
  • The fan stall guard system of boiler airing system of the class of 500MW capacity to protect fan. But because confidence is loosed and operation is influenced by frequent fault of fan stall guard system, confidence is improved by substituting DCS Logic for it.

Development of Fan Stall Warning Equipm4ent (송풍기 맥동 감시 장치 개발)

  • Cho, Hyun-Seob
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.9 no.4
    • /
    • pp.924-928
    • /
    • 2008
  • In this paper, The fan stall guard system of boiler airing system of the class of 500MW capacity to protect fan. But because confidence is loosed and operation is influenced by frequent fault of fan stall guard system, confidence is improved by substituting DCS Logic for it.

Characteristics of Rotating Stall in a Centrifugal Compressor with Vaned Diffuser (원심압축기 베인 디퓨저에서의 선회실속 특성)

  • Lee, Du-Yeol;Kang, Chang-Sik;Shin, You-Hwan;Kim, Kwang-Ho
    • 유체기계공업학회:학술대회논문집
    • /
    • 2001.11a
    • /
    • pp.99-105
    • /
    • 2001
  • In this study, the instability of a centrifugal compressor with vaned diffuser was investigated. During unstable operation of the test compressor, pressure fluctuations at different diffuser radius ratios were measured by using high frequency pressure transducers. Two different types of stall, mild and deep stall, were observed alternately and irregularly at some flow rate where the compressor performance was steeply deteriorated. In this transient zone, the size of rotating stall cell was estimated through the Wavelet transform analysis. It was about 45 percents of rotor circumferential space at 3000 rpm and not dependent on flow rate.

  • PDF

Stall Critical Flow Angle in a Vaneless Diffuser of a Centrifugal Compressor (베인없는 디퓨저에서의 스톨 임계 유동각에 관한 연구)

  • Kang Jeong-Seek;Kang Shin-Hyoung
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.611-614
    • /
    • 2002
  • Rotating stall in vaneless diffusers of centrifugal compressor occurs in the diffuser wall due to flow separation at large inlet flow angle. For this reason, the critical inlet flow angles are suggested by several researchers. Beyond this critical angle, flow separates in the diffuser, and develops into rotating stall. This paper studied this critical flow angle. Rotating stall is measured through eight fast-response pressure transducers which are equally spaced around the circumference at the inlet and exit of a vaneless diffuser. Experiments are done from 20000rpm to 60000rpm for the diffuser stall. Two-cell structure which rotates at $6{\~}l0{\%}$ of impeller speed is fully developed at $20000{\~}40000rpm$, and three-cell structure which rotates at $7{\~}9{\%}$ of impeller speed is fully developed at $50000{\~}60000rpm$. This paper shows that the critical inlet flow angle is not constant but related with tip speed of impeller. As tip speed increases, so does the critical inlet flow angle.

  • PDF

Effect of Diffuser Width on Rotating Stall in Centrifugal with Vaneless Diffuser (원심형 송풍기에서 베인리스 디퓨저의 폭변화가 선회실속에 미치는 영향)

  • Kim, Jin-Hyeong;Jo, Gang-Rae
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.10
    • /
    • pp.1293-1302
    • /
    • 2001
  • It is generally known that radial vane blowers with vaneless diffuser may generate mostly only a rotating stall but backward curved vane blowers may do both an impeller and a diffuser rotating stalls. In this study, it was found from the numerical and experimental results that the diffuser rotating stall does not appear in a radial vane because of the suppression for the diffuser stall appearance by occurring of impeller rotating stall in a large flow rate coefficient. The diffuser rotating stalls occurring when the width of diffuser is broaden fur a backward curved vane blower are classified definitely by the diffuser flow rate coefficient defined by adopting the varying diffuser width.